• Title/Summary/Keyword: Cooling rate to 77 K

Search Result 20, Processing Time 0.025 seconds

Effects of artificial holes on the cooling efficiency of single grain Y1.5Ba2Cu3O7-y bulk superconductors (단결정 Y1.5Ba2Cu3O7-y 벌크 초전도체의 냉각효율에 대한 인공 구멍의 효과)

  • Kim, Kwang-Mo;Park, Soon-Dong;Jun, Byung-Hyuk;Ko, Tae-Kuk;Kim, Chan-Joong
    • Progress in Superconductivity and Cryogenics
    • /
    • v.14 no.3
    • /
    • pp.1-4
    • /
    • 2012
  • Effects of artificial holes on the cooling efficiency of single grain YBCO bulk superconductors were studied. Single grain YBCO bulk superconductors without artificial holes, with six 2.4 mm holes and six holes filled with Bi-Pb-Cd-Sn metal solder were fabricated by a top-seeded melt growth process for powder compacts with/without holes. Simulation for the cooling rate to a liquid nitrogen temperature (77 K) of YBCO samples was carried out using a finite element method (FEM) and the results are compared with the actual cooling rates of samples in liquid nitrogen. The simulated cooling times for the YBCO sample without holes, with six holes and with six holes filled with the metal solder were 80, 47 and 75 sec. respectively, which are similar to the actual cooling times of 84, 52 and 78 sec. estimated for the same samples cooled in liquid nitrogen. The shorter cooling time of the sample with artificial holes are attributed to the increased surface areas associated with the presence of artificial holes. The metal filling into the holes did not give any remarkable effect on the cooling efficiency.

Pressure Drop Characteristics on HTS Power Cables with LN2 Flow (초전도 케이블 냉각유로에서의 압력강하 특성)

  • Koh Deuk-Yong;Yeom Han-Kil;Lee Kwan-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.1
    • /
    • pp.81-86
    • /
    • 2006
  • High temperature superconducting (HTS) power cable requires forced sub-cooled LN2 flow cooling. Liquid nitrogen is circulated by a pump and cooled back by cooling system. Typical operating temperature range is expected to be between 65 K and 77 K. The HTS power cable needs sufficient cooling to overcome its low temperature heat load. For successful cooling, the hydraulic characteristics of the HTS power cable must be well investigated to design the cables. Especially, the pressure drop in the cable is an important design parameter, because the pressure drop decides the length of the cable, size of the coolant circulation pump and circulation pressure, etc. This paper describes measurement and investigation of the pressure drop of the cooling system. In order to reduce the total pressure drop of the cooling system, the flow rate of liquid nitrogen must be controlled by rotational speed of the circulation pump.

Melt Properties of Plasma Display Panel Substrate Glasses Based on Float Process (Float 공법을 고려한 Plasma Display Panel용 기판유리 용융체의 특성)

  • Kim, Ki-Dong;Jung, Woo-Man;Jung, Hyun-Su;Kwon, Sung-Ku;Choi, Se-Young
    • Journal of the Korean Ceramic Society
    • /
    • v.43 no.7 s.290
    • /
    • pp.433-438
    • /
    • 2006
  • In order to examine the working condition of melts in tin bath of float process it was investigated Sn diffusion behavior and solidification rate of melts for alkali-alkaline earth-silica PDP substrate glasses such as commercial CaO rich CS-77 glass, commercial $Al_2O_3$ rich PD-200 glass and self developed $SiO_2$ rich T-series (T-2, T-4, T-6) glasses. In the case of Sn depth and concentration created in glass surface by ion exchange between Sn and alkali, T-series showed lower value than CS-77, especially T-2 is more excellent than PD-200. The solidification rate of melts expressed by cooling time between $log{\eta}=4\;and\;7.6dPa{\cdot}s$ was low for T-series comparing with CS-77 and PD-200. Therefore, it was concluded that T-series is desirable considering forming condition in the tin bath of the float process.

Real operation of 2 kW class reverse-Brayton refrigeration system with using scroll compressor package

  • Kim, Hyobong;Yeom, Hankil;Choo, Sangyoon;Kim, Jongwoo;Park, Jiho;In, Sehwan;Hong, Yong-Ju;Park, Seong-Je;Ko, Junseok
    • Progress in Superconductivity and Cryogenics
    • /
    • v.22 no.4
    • /
    • pp.40-44
    • /
    • 2020
  • This paper describes the real operation of 2 kW class reverse-Brayton refrigeration system with neon as a working fluid. The refrigeration cycle is designed with operating pressure of 0.5 and 1.0 MPa at low and high pressure side, respectively. Compressor package consists of several helium scroll compressors witch are originally used for driving GM cryocooler. Three segments of plate heat exchanger are adopted to cover the wide temperature range and the refrigeration power is produced by turbo expander. The developed refrigeration system is successfully operated at its target temperature of 77 K. In experiments, all parameters such as pressure, temperature, mass flow rate and valve opening are measured to investigate characteristics during cool-down process and normal state. The difference between design and real operation is discussed with measured experimental data. At normal state of 77 K operation, the developed reverse-Brayton refrigeration system shows 1.83 kW at 68.2 K of cold-end temperature.

Fire Suppression Effect of PPV with Water Mist System (미세물분무를 이용한 PPV의 화재진압효과)

  • Kim, Sung-Won;Shin, Chang-Sub
    • Journal of the Korean Society of Safety
    • /
    • v.18 no.4
    • /
    • pp.71-77
    • /
    • 2003
  • To inject fresh air into a fire room, Positive Pressure Ventilation (PPV) can be used and the blower of PPV increases inside pressure of the room. It makes high flow rate of products of combustion, smoke and heat from the structure, and it is very helpful to fireman on the fire extinguishing work. The flame moves to the direction of airflow and the temperature of flame can be decreased rapidly. In this experiment, a water mist system is applied to PPV to increase the effectiveness, and various effective factors are studied. n-Heptane and pine wood stick were used as fuel. Temperatures at the above and behind the combustion pan were strongly reduced by the water mist system and by the convective cooling with airflow. The smoke density was also decreased by PPV with water mist system and it can be explained by the absorption of smoke particles on the water mist droplet and by the strong exhausting effects of mobile fan.

Cryogenic Systems for HTS Power Cables

  • Yeom, Han-Kil;Koh, Deuk-Yong;Lee, Bong-Kyu;Kim, Ig-Seang
    • Progress in Superconductivity and Cryogenics
    • /
    • v.5 no.1
    • /
    • pp.133-135
    • /
    • 2003
  • Cryogenic systems are requirement for the operation of HTS power cables. In general, HTS power cables require temperature below 77K, a temperature that can be achieved from the liquid nitrogen at latm or sub-cooled LN2 above latm. HTS power cable needs sufficient refrigeration to overcome its low temperature heat loading. This loading typically cones in two forms : (1) heat leaks from the surroundings and (2) internal heat generation. This paper explains the cooling test system of 10m HTS power cable. This system is composed of storage dewar, auto fill system, core cryostat and cold-box. Storage dewar is a LN2 storage tank and auto fill system is a LN2 supply device to the sub-cooler, Core cryostat is a LN2 flow line. Cold box is a control unit of temperature and flow rate. It is composed of control valve, flow meter, sub-cooler and circulation pump, etc..

Development of Effective Cryopreservation Method for Mammalian Embryo (포유류 초기 배아의 효율적인 동결 보존 방법에 관한 연구)

  • Kim, Hyun;Cho, Young Moo;Ko, Yeoung-Gyu;Kim, Sung Woo;Seong, Hwan-Hoo;Yamanouchi, Keitaro
    • Journal of Embryo Transfer
    • /
    • v.29 no.3
    • /
    • pp.241-248
    • /
    • 2014
  • This study was carried out to evaluate the effects of embryonic stage, cryoprotectant, and freezing-thawing method on the rates of survival and development of the cryopreserved mouse early embryo and finally to establish the cryopreservation method of surplus embryos obtained during assisted reproductive technology (ART). Two to eight cell embryos were obtained from oviducts of mated $F_1$ hybrid female mice superovulated by PMSG and hCG. Two-step EG, DMSO and 4-step EG, DMSO were used as cryoprotectant and dehydration and rehydration method of embryos, and slow-cooling or rapid-cooling method was used as frozen program. The survival rates of embryos were measured after thawing and rehydration, and the developmental rates of embryos were compared and observed during culturing embryos for 24, 48, 72, 96 hrs. As for the survival and development rates of embryos according to embryonic stage, the survival rate of 2 cell stage in EG and DMSO was significantly higher than 4~8 cell (65.4% versus 61.2%, 81.1% versus 72.5%) (p<0.01, p<0.01), but the development rates of 4~8 cell embryos in EG and DMSO were significantly higher than 2 cell embryos for whole culture period (p<0.01) and the development rates of 4~8 cell embryos in EG were significantly higher than 2 cell embryos in DMSO (p<0.01). As for the survival and development rates of embryos according to cryoprotectant, the survival rate of 2 cell embryo in DMSO was significantly higher than that in EG(77.0% versus 64.4%) (p<0.01), whereas the development rate of embryos was not differ till 24 hrs. The development rate from morular to hatching blastocyst, however, was sinificantly higher in EG than in DMSO during 48 hr (p<0.01). The survival rate of 4~8 cell embryo was 62.5% in EG and 73.3% in DMSO. The development rates of embryo in EG were significantly higher for whole culture periods (p<0.01, 0.05). In respect to the effect of freezing and thawing program on the survival and development rates of embryos, method of slow cooling and rapid thawing was more effective than that of rapid cooling and rapid thawing. The survival rate of embryo in 2 cell stage was higher than in 4~8 cell stage, and EG appears more effective cryoprotectant than DMSO because EG showed better development rates of embryos in 2 and 4~8 cell stage. Moreover, slow cooling and rapid thawing method was considered as the best cryopreservation program.

A Study on Effectiveness and Preference of Tangible Fitness Game (체감형 운동게임의 효과와 선호도에 대한 연구)

  • Kim, Eui-Young;Park, Chang-Hoon;Kim, Dae-Geun
    • Journal of Korea Game Society
    • /
    • v.12 no.1
    • /
    • pp.67-77
    • /
    • 2012
  • With the development of tangible interface in recent years, the interest in interactive exercise games to improve health-related physical fitness has been increased. We believe that this kind of serious game should provide not only motion sensing of the action required to play sports but also a specific effectiveness of exercise. This paper will show how a serious exercise game affects theirs heart rate and preference. For the experiments, we used an exercise game named GalaxyBike for aerobics exercise which is developed by the Interaction Media Research Center of Hoseo University. In the experiments, players' heart rate was measured during the warming-up, exercise and cooling-down periods by a wireless heart-rate measuring instrument. After they played the exercise game, a survey was conducted to see how they like this serious exercise game. The findings of the study suggest that the serious exercise game providing both video game and exercise would make a contribution to the improvement of health-related physical fitness since it serves to increase the heart rate and motivation.

A Study on the Condensation Heat Transfer of Low Integral Fin Tubes (낮은 핀 관의 응축 열전달 성능에 관한 연구)

  • Han, Gyu-Il;Park, Seong-Guk
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.32 no.1
    • /
    • pp.67-77
    • /
    • 1996
  • The heat transfer performance of R - 11 vapor condensing on integral fin tubes has been studied using fin tubes having the fin density from 748 to 1654 fins per meter. Electric heater supplied heat energy to the boiler to generate R - 11 vapor over the range of 25-60W. Condensation rates of each tubes were tested under the condition of cooling water flow rate from 400l/h to 2500l/h. For the seven fin tubes tested, the best performance has been obtained with a tube having a fin density of 1417fpm and a fin height of 1.3mm. This tube has yielded a maximum value of the heat transfer coefficient of 16500W/$m_2$K, at a vapor to wall temperature difference of 3K. Experimental results of integral fin tubes have been compared with available predictive models such as Beatty - Katz's analysis, Webb's analysis, Sukhatme's analysis and Rudy's empirical relation. The experimental results were shown to be in good agreement with that of the Sukhatme's analysis.

  • PDF

Interlaboratory Comparison of Critical Current Measurements on Ag-sheathed Bi-2223 tapes (Bi-2223선재의 임계전류 측정기술 비교)

  • Lee, Kyu-Won;Han, Gi-Youl
    • Progress in Superconductivity
    • /
    • v.3 no.1
    • /
    • pp.99-103
    • /
    • 2001
  • We have conducted two runs of interlaboratory comparison on Ag-sheathed Bi-2223 tapes to evaluate the level of measurement techniques for the critical current measurement. Two classes of specimens were prepared for parallel and serial routings and sent to four participating laboratories. The critical currents of specimens were measured at 77 K in zero magnetic field. In the first comparison, we used twenty different Bi-2223 tapes as specimens for comparison and participating laboratories measured the specimens using their own instruments and procedures. As a result, the scattering of data on the first comparison showed -3.0% to +l2.2% for the parallel routing and -0.7% to +l5.1% for the serial routing. Major sources of these variations were attributed to different measurement techniques. Thus, the second comparison of measurement was done on the same specimens under specified measurement conditions, particularly in terms of cooling procedure and sweep rate of the test current. The variations for the second comparison were decreased -3.1% to +3.2% far the parallel routing and -1.8% to +7.7% fur the serial routing.

  • PDF