• 제목/요약/키워드: Cooling mode

검색결과 321건 처리시간 0.027초

빙축열 냉방 시스템의 동적 시뮬레이션 (Dynamic simulation of the ice storage cooling system)

  • 한도영;이준호
    • 설비공학논문집
    • /
    • 제11권6호
    • /
    • pp.815-823
    • /
    • 1999
  • A dynamic simulation program may be used for the development of effective control algorithms for the ice storage cooling system. Simplified effective dynamic models for an ice-on-coil type storage tank, a screw chiller, a water-to-air heat exchanger, three way valves, pipes, pumps, temperature sensors, and controllers were developed. And a dynamic simulation program for the ice storage cooling system was developed by using these dynamic models. Control algorithms for the full storage system were also selected and analyzed in order to show the effectiveness of these models. From the simulation results, it may be concluded that the simulation program developed in this study can be effectively used for the development of improved control algorithms for the ice storage cooling system.

  • PDF

Investigating risk of overheating for school buildings under extreme hot weather conditions

  • Lykartsis, Athanasios;B-Jahromi, Ali;Mylona, Anastasia
    • Advances in Energy Research
    • /
    • 제5권4호
    • /
    • pp.277-287
    • /
    • 2017
  • This study examines the risk of overheating of a school building, under extreme hot weather conditions, in 14 locations in the United Kingdom using the overheating criteria defined in Building Bulletin 101 (BB101). The building was modelled as naturally ventilated, mechanically ventilated and in mixed mode and was simulated both for the current and the projected weather conditions of the 2050s. Under the current weather conditions, results of the simulations show that when naturally ventilated, the school building fulfils the BB101 criteria only in the areas of Edinburgh and Glasgow. In the simulations of the building as mechanically ventilated and in mixed mode, mechanical cooling was provided in order for the building to comply with the overheating criteria. A comparison of the required cooling loads between the two scenarios shows that application of mixed mode ventilation results in less cooling loads.

냉각탑을 이용한 축열식 히트펌프시스템의 성능측정에 관한 연구 (A study on performance test of water heat storage type heat-pump system using cooling tower heat source)

  • 이상훈;박효식;한우용;김욱중
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.1099-1104
    • /
    • 2008
  • Recent year, mean energy consumptions of a people are higher than other country. And international oil price became over 120 dollar. This energy environment as well as energy war. Maybe, the Meteorological Administration is going to enforce scorching heatwave special report system from that come summer. Besides, 2008 summer, maximum demand power is expected by 64,240,000kW. The electric power equipment reserve rate appeared in to keep 12.5% level. Chilled water storage system witch is one of electric load administration system. Heat pump system used cooling tower heat recovery is advantage that use is possible to summer in small a public bath building. In this paper, we suggest that heat pump system by heat recovery using cooling tower when it is heating operation of ambient air temperature. To apply cooling tower heat recovery heat pump to chilled water heat storage type and achieved performance evaluation about operation. As a result, performance of heat pump system that about 121% in cooling mode, 138% in heating mode higher than KEPCO standard. And heating operation possible to ambient air temperature about $23^{\circ}C$, which of appear cooling tower outlet temperature about $13^{\circ}C$.

  • PDF

밀폐식 냉각탑용 열교환기의 성능에 관한 연구 (A Study on the Performance of Heat Exchanger for Closed Cooling Tower)

  • 이상식;유성연;김진혁;안영환;박형준;유해성
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.334-339
    • /
    • 2008
  • An closed cooling tower is a device similar to a general cooling tower, but with cooling tower replaced by a heat exchanger. The purpose of this study is to evaluate thermal performance of heat exchanger at various conditions and to provide design datebase. The experimental study regarding heat exchanger for closed cooling tower was conducted. Experimental apparatus consists of constant temperature bath, water pump, spray nozzle, heat exchanger, fan, and date acquisition system. Heat transfer rates at various air velocitys, water flow rates, two different spray modes were measured and heat transfer coefficient were calculated to compare the thermal performances. This study provides that the heat transfer coefficient increases with increasing spray water flow rate and with increasing air velocity. The wet mode was more effective than dry mode for closed cooling tower to this study.

  • PDF

수소연료전지 자동차의 열관리시스템 성능특성에 관한 연구 (Performance Characteristics of the Thermal Management System for Passenger Hydrogen Fuel Cell Vehicle)

  • 이호성;원종필;조중원;이무연
    • 한국산학기술학회논문지
    • /
    • 제13권3호
    • /
    • pp.986-993
    • /
    • 2012
  • 본 연구의 목적은 수소연료전지 자동차의 열관리시스템 성능특성을 알아보기 위하여 다양한 운전조건 변화에 따른 열전달 성능특성을 고찰하는 것이다. 수소연료전지 자동차의 열관리시스템으로 스택 냉각시스템, 전자장비 냉각시스템, 그리고 냉방시스템의 성능특성 및 상호영향도를 파악하기 위하여 자동차 실 도로 운전조건 변화에 따른 냉방성능 및 전자장비 냉각시스템에 미치는 영향을 파악하였다. 결과적으로, 고속도로 조건에서 냉방시스템 작동 시 수소연료전지 자동차의 스택 냉각시스템의 방열성능은 냉방시스템이 꺼진 경우보다 평균 28.8% 감소하였고, 시내주행 조건에서 수소연료전지 자동차의 전자장비 냉각시스템의 냉각부하는 고속주행 조건보다 약 65.6% 상승하였다.

고주파 모터 내장형 주축의 냉각에 따른 열특성 해석 (Analysis oil the Thermal Characteristics of the Spindle with High Frequency Motor according to the Cooling Methods)

  • 김수태;최대봉;조환석
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 추계학술대회 논문집
    • /
    • pp.969-974
    • /
    • 2002
  • Thermal characteristics according to the cooling methods are studied for the three type spindles with high frequency motor. For the analysis, three dimensional mode]s are built considering heat transfer characteristics such as natural and force convection coefficients. Unsteady-state temperature distributions and thermal deformations according to the cooling conditions are analyzed by using the finite element method.

  • PDF

CPU 냉각용 저소음 Micro-Cooling Fan 의 개발 (Development of Micro-Cooling Fans for Cooling of CPU)

  • 김기황;박용민;김진화;이승배
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 춘계학술대회논문집
    • /
    • pp.961-966
    • /
    • 2001
  • Micro fans of randomly swept-blades were designed to provide C.P.U. in a personal computer with effective cooling in a very quiet mode. The proto--type axial micro-fans machined by a laser sintering machine were tested against manufactured products by comparing the performance and overall sound pressure level with spectral measurements in an environment suggested by ASHRAE and ANSI standards. The predicted OSPLs and directivity patterns of fans by iDesignFan software were in good agreements with measured data. The newly introduced fans of randomly swept-blades were proved to provide a very promising mode of low noise at small loading conditions.

  • PDF

수평형 지열히트펌프 시스템의 시설원예 냉난방 실증 효과 (Heating and Cooling Effect of Portected Horticulture by Geothermal Heat Pump System with Horizontal Heat Exchanger)

  • 유영선;강연구;김영중;강금춘
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 춘계학술대회 논문집
    • /
    • pp.630-633
    • /
    • 2008
  • Geothermal heat pump systems use the earth as a heat source in heating mode and a heat sink in cooling mode. These systems can be used for heating or cooling systems in farm facilities such as greenhouses for protected horticulture, cattle sheds, mushroom house and etc. A horizontal type means that a geothermal heat exchanger is laid in the trench buried in 1.2 to 1.8 m depth. Because a horizontal type has advantages of low installation, operation and maintenance costs compared to a vertical type, it is easy to be adopted to agriculture. In this study, to heat and cool farm facilities and obtain basic data for practical application of horizontal geothermal heat pump system in agriculture, a horizontal geothermal heat pump system of 10 RT was installed in greenhouse. Heating and cooling performance of this system was estimated. The horizontal geothermal heat pump used in this study had heating COP of 4.57 at soil temperature of $14^{\circ}C$ with depth of 1.75m and heating COP of 3.75 at soil temperature of $7^{\circ}C$ with the same depth. The cooling COP was 2.7 at ground temperature at 1.75m depth of $25.5^{\circ}C$ and 2.0 at the temperature of $33.5^{\circ}C$.

  • PDF

태양열을 이용한 흡수식 냉방기의 동특성 시뮬레이션 (Dynamic simulation of a solar absorption cooling system)

  • 정시영;조광운
    • 설비공학논문집
    • /
    • 제10권6호
    • /
    • pp.784-794
    • /
    • 1998
  • The present study has been directed at developing thermal models to investigate the dynamic behavior of a solar cooling system including an absorption chiller, solar collectors, a hot water storage tank, a fan coil unit, and the air-conditioned space. The operation of the system was simulated for 8 hours in two different operation modes. In the mode 1, the system operated without any capacity control.0 the mode 2, an auxiliary boiler supplied heat to the generator if hot water temperature became lower than a certain value. Moreover, the mass flow rate of hot water to the generator was controlled by comparing the instantaneous room air temperature with the design value. The variation of temperature and concentration in the system components and that of heat transfer rates in the system were obtained for both modes of operation. It was found that the room temperature was maintained near the desired value in the mode 2 by supplying auxiliary heat or controlling the mass flow rate of hot water, while the deviation of room temperature was quite great in the mode 2.

  • PDF

공기 및 지열 이용 Dual-Source 히트펌프 시스템의 성능실험 및 경제성 분석 (The Performance Test and the Feasibility Study for a Dual-Source Heat Pump System Using the Air and Ground Heat Source)

  • 남유진;채호병
    • 설비공학논문집
    • /
    • 제26권5호
    • /
    • pp.212-217
    • /
    • 2014
  • Recently, the use of renewable energy has been increased due to growing concern on the energy-saving at buildings and the reduction of $CO_2$ emission. In the field of architecture, to reduce the energy consumption of heating, cooling and hot water supply, heat pump systems with renewable energy has been developed and used in various applications. However, there have been many of researches on the large-scale commercial heat pump systems, but the research and the field application of a compact heat pump system is rare. Therefore, in order to develop the compact heat pump for the small-scale residential building, this study conducted the performance test and feasibility study for a hybrid heat pump using the heat source of air, solar and ground. In the results of experiments through a trial product, the average COP of cooling mode with ground heat source was 4.75, and it of heating mode was 4.03. Furthermore, the average COP of cooling mode with air heat source was 2.60, and it of heating mode was 2.92. Finally, payback period of the system was calculated as 9.2 years.