• 제목/요약/키워드: Cooling method

검색결과 2,234건 처리시간 0.026초

고온초전도 케이블 냉각길이 장척화를 위한 최적 냉각방안 (An Optimal Cooling Method for Long HTS Power Transmission Cable)

  • 이창호;김도형;김춘동;김균석;김익생
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제6권3호
    • /
    • pp.56-61
    • /
    • 2004
  • An optimal cooling method for a long HTS power transmission cable was scrutinized by using theoretical models. Cooling length of HTS cable is determined by pressure range and temperature range of LN2 in the HTS cable. Results showed limitation from temperature range is stricter than that from pressure range. The well-known one-side cooling was modified to two-side cooling. It was shown that cooling length can be nearly doubled by adopting two-side cooling of the same capacity.

반도체 식각 공정용 냉각 시스템 구축을 위한 AMESim 모델 개발 (A Study on the Development of AMESim Model for Construction of Cooling System for Semiconductor Etching Process)

  • 김대현;김광선
    • 반도체디스플레이기술학회지
    • /
    • 제16권3호
    • /
    • pp.106-110
    • /
    • 2017
  • Due to the plasma applied from the outside, which acts as an etchant during the etching process, considerable heat is transferred to the wafer and a separate cooling process is performed to effectively remove the heat after the process. In this case, a direct cooling method using a refrigerant is suitable for cooling through effective heat exchange. The direct cooling method using the refrigerant using the latent heat exchange is superior to the cooling method using the sensible heat exchange. Therefore, in this paper, AMESim is used to design a direct refrigerant cooling system using latent heat exchange simulator was built.The constructed simulator is reliable compared with the actual experimental results. It is expected that this simulator will help to design and search for optimal process conditions.

  • PDF

Structural analysis and optimization of large cooling tower subjected to wind loads based on the iteration of pressure

  • Li, Gang;Cao, Wen-Bin
    • Structural Engineering and Mechanics
    • /
    • 제46권5호
    • /
    • pp.735-753
    • /
    • 2013
  • The wind load is always the dominant load of cooling tower due to its large size, complex geometry and thin-wall structure. At present, when computing the wind-induced response of the large-scale cooling tower, the wind pressure distribution is obtained based on code regulations, wind tunnel test or computational fluid dynamic (CFD) analysis, and then is imposed on the tower structure. However, such method fails to consider the change of the wind load with the deformation of cooling tower, which may result in error of the wind load. In this paper, the analysis of the large cooling tower based on the iterative method for wind pressure is studied, in which the advantages of CFD and finite element method (FEM) are combined in order to improve the accuracy. The comparative study of the results obtained from the code regulations and iterative method is conducted. The results show that with the increase of the mean wind speed, the difference between the methods becomes bigger. On the other hand, based on the design of experiment (DOE), an approximate model is built for the optimal design of the large-scale cooling tower by a two-level optimization strategy, which makes use of code-based design method and the proposed iterative method. The results of the numerical example demonstrate the feasibility and efficiency of the proposed method.

수용가 냉방부하를 고려한 하절기 주상변압기 최대부하 추정 (Peak Load Estimation of Pole-Transformer in Summer Season Considering the Cooling Load of Customer)

  • 윤상윤;김재철;김기현;임진순
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제50권1호
    • /
    • pp.20-27
    • /
    • 2001
  • In this paper, we propose a method for estimating the peak load of pole-transformer in summer season considering the degree of cooling load possession in customer. The cooling load of customer is selected as the most reliable parameter of peak load in summer season. The proposed estimation method is restricted to the aspect of load management for pole-transformer. The main concept of proposed method is that the error of peak load estimation using load regression equation reduces with considering the degree of cooling load possession in customer. We propose an index for estimation of cooling load possession in each customer. The proposed index is defined as cooling load possession in customer (CLPC) and obtained from the increment of monthly electric energy. The membership function for deciding the uncertainty of cooling load possession in customer is used. The database of pole-transformer in Korea Electric Power Corporation (KEPCO) is used for case studies. Through the case studies, we verify that the proposed method reduces the error of peak load estimation than the conventional method in domestic.

  • PDF

Mist를 이용한 저공해 연삭 가공기술 개발 (Development of Low Pollution Grinding Technology using Mist)

  • 최헌종;이석우;김대중;정해도
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2000년도 추계학술대회 논문집
    • /
    • pp.793-797
    • /
    • 2000
  • The environmental problems by using coolant demanded the new cooling methods. As one of them the studies on the dry grinding with compressed cold air have been done. The cooling method using compressed cold air was effdve thmugh going down the temperature of compressed air supplied below $-25^{\circ}C$ and inneasing the amount of mmpresd cold air, but had not enough cooling effect due to the low performance of lubrication. Therefore, the cooling methods using MQL(Minimum Quantity Lubrication) or mist newly were suggested. These two methods can satisfy both cooling effect and lubrication with only small amount of coolant, also has the benefit in the point of decreasing the envimnmental pollution. This paper focused on analyzing the grindmg characteristics of the cooling method using mid. The generated heat and grinding force of the cooling method using mist were compared with them of coolant and compressed cold air. And them grinding test according to the temperature of compressed cold air, mist spray amount and mist supply direction were done.

  • PDF

열전모듈을 이용한 에어컨의 방열부 냉각특성에 대한 연구 (Cooling Characteristics at Hot Side of the Thermoelectric Module for an Air Conditioner)

  • 김서영;강병하;장혁재;김석현
    • 설비공학논문집
    • /
    • 제14권3호
    • /
    • pp.214-220
    • /
    • 2002
  • A small air conditioner using thermoelectric module has been designed and built. Three types of cooling methods, such as air cooling, closed-loop water cooling, and evaporative cooling, for hot side of thermoelectric module have been investigated. Among three types of cooling method, the evaporative cooling method is seen to be the most effective to achieve the steady state operation of a thermoelectric air conditioner The system performance with evaporative cooling method are also studied in detail for several oprating parameters, such as input power to the thermoelectric module, water or air flow rate at the hot side, and air flow rate at the cold side. The results obtained indicate that the cooling capacity of a system is increased with an increase in the input power to the thermoelectric module while the system COP is decreased. It is also found that the optimal air flow rate as well as water flow rate at the hot side is needed for the best system performance at a liven operating condition. Both the system COP and cooling capacity are increased as the air flow rate at cold side is increased.

공동주택에서 바닥복사냉방의 적정 운영방안에 관한 연구 (A Study on the Operation Strategy of Radiant Floor Cooling in Apartment Buildings)

  • 조영흠;석호태;여명석;김광우
    • 설비공학논문집
    • /
    • 제16권6호
    • /
    • pp.574-583
    • /
    • 2004
  • In this study, the operation strategy of the radiant floor cooling is evaluated in terms of indoor environmental conditions and energy consumption through simulations using the TRNSYS comparing the existing cooling operation. The operation strategy during continuously operated for cooling is proposed that a representative room had additional equipments and other rooms were operated with only a radiant floor cooling system and that system and control method for cooling are varied with period while intermittently operated for cooling. Specifically, when there are no people in the room, rooms were operated by only radiant floor cooling system using cooling storage and when people are occupied, rooms were operated by dehumidification and supplementary cooling device with radiant floor cooling system. The results of this study show that proposed operation strategy can stably maintain the set room air temperature and can reduce the energy consumption compared to the existing cooling method during continuously operated for cooling. While intermittently operated for cooling, the difference of set room air temperature by proposed operation strategy does not happen, satisfying comfort standards and the radiant floor cooling can expect to supply stable electric power because of decreasing demand for peak electric power of energy consumption.

컴퓨터 내장형 냉각시스템 개발 (Development for Inserted Type Coling System in Computer)

  • 이현용;임선종
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2009년도 추계학술대회
    • /
    • pp.399-404
    • /
    • 2009
  • The research for computer cooling system has been researched briskly at home and abroad. Most of computer cooling systems are the air cooling method using cooling fan. The air cooling system are most widely used for low cost and easy installation but have limits in cooling. The water cooling system are good for cooling efficiency but bad for installation. This paper presents the developing for cooling system to be inserted in computer using thermoelectric module.

  • PDF

축류 팬을 이용한 충돌제트 전자냉각 설계개념에 대한 연구 (Study on the Design Concept of Impinging Jet Electronics Cooling by Using Axial Fan)

  • 이찬;길현권
    • 한국유체기계학회 논문집
    • /
    • 제12권2호
    • /
    • pp.24-30
    • /
    • 2009
  • Flow and noise analyses are conducted for examining a new design concept of impinging jet electronics cooling, and the analysis results are compared with conventional electronics cooling techniques. For the application of impinging jet electronics cooling method, the present study considers the air duct where air is supplied by axial fan and air flow from the duct is impinged vertically onto the electronic component heat source. Applying CFD simulation technique and fan noise model to the present cooling scheme, the cooling performance of the impinging jet as well as the operation condition and the noise characteristics of fan are investigated for various impinging jet nozzle conditions and fan models. Furthermore, the impinging jet electronics cooling analysis results are compared with the conventional parallel-flow cooling scheme to give the design concept and criteria of impinging jet cooling method.

압축냉각공기와 오일미스트를 이용한 환경친화 연삭가공기술 (Ecological Grinding Technology Using Compressed Cold Air and Oil Mist)

  • 이석우;최헌종;허남환
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 춘계학술대회 논문집
    • /
    • pp.24-27
    • /
    • 2002
  • The environmental problems by using coolant demanded the new cooling methods. As one of them, the studies on the finding with compressed cold air and oil mist have been done. The cooling method using compressed cold air was effective through going down the temperature of compressed air supplied below $-25^{\circ}$ and increasing the amount of compressed cold air, but had not enough cooling effect due to the low performance of lubrication. Therefore, the cooling methods using oil mist newly were suggested. This method can satisfy both cooling effect and lubrication with only small amount of coolant, also have the benefit in the point of decreasing the environmental pollution. This paper focused on analyzing the grinding characteristics of the cooling method using oil mist. The grinding test according to compressed cold air, oil mist spray pressure and oil mist supply direction were done.

  • PDF