• Title/Summary/Keyword: Cooling heating energy consumption

Search Result 277, Processing Time 0.028 seconds

Basic research on the Building Energy Load Depending on The Climate Change in Korea (대한민국 표준기상데이터의 변화추이와 건물부하량에 관한 기초연구)

  • Yoo, Ho-Chun;Lee, Kwan-Ho;Kang, Hyun-Gu
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.3
    • /
    • pp.66-72
    • /
    • 2009
  • As 'Low Carbon Green Building' is highly required, programs to evaluate building performance are actively and commonly used. For most of these programs, dynamic responses of buildings against external weather changes are very important. In order to simulate the programs, weather data of each region must be properly entered to estimate accurate amount of building energy consumption. To this end, the existing weather data and weather data of KSES were compared and analyzed to find out how weather changes. Energy load of Korea's standard houses was also analyzed based on this data. As a result, data corresponding to June ${\sim}$ September when cooling is supplied shows 23% of average increase with 30% of peak increase(June). On the other hand, data corresponding to November ${\sim}$ February when heating is supplied shows 29% of average decrease with 34% of peak decrease(November). Increase in cooling load and decrease in heating load in the above data comparison/analysis show that KSES 2009 data reflects increase in average temperature caused by global warming unlike the existing data. Increase in dry-bulb temperature depending on weather change of standard houses increases cooling load by 17% and decreases heating load by 36%

Time Dependent Thermal Load Analysis of the Building with an Airflow Window System (공기식 집열창 시스템이 설치된 건물의 동적부하 해석)

  • Cho, S.H.;Park, S.D.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.4 no.2
    • /
    • pp.82-95
    • /
    • 1992
  • It has been known that the application of an airflow window system reduces the energy consumption compared with conventional double pane window in a building. But how to analyze thermal load in a building with an airflow window system has not been well known. so two kinds of method (Mode 1 and Mode 2) to analyze time dependent thermal load of the building with an airflow window system are presented in this study. The results of load analysis about the model building(total area : $4521m^2$, 3 floors) by Mode 2 show that the maximum cooling and heating load in a building with an airflow window system are decreased about 12-17% and about 19.5% than with double pane glass window, and yearly energy consumption with an airflow window system is saved about about 20% than with double pane glass window.

  • PDF

A study on the environmental load of office buildings in Seoul (서울지역 사무소 건물의 환경부하에 관한 연구)

  • 이상형;이윤규;양관섭;안태경;이승언;박효순
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.2
    • /
    • pp.244-249
    • /
    • 1999
  • This study is to examine the emission rate of $CO_2$gas as the environmental load in office buildings. After the investigation of monthly consumption of each energy source(electricity and natural gas), it is analyzed that the $CO_2$emission rate of 34 office buildings surveyed is 22.4kg-$c/m^2$.year, which consists of 17.5kg-$c/m^2$.year by consuming electricity, and 4.9kg-$c/m^2$.year by consuming natural gas. And the $CO_2$emission rate of each load in those buildings consists of 68% emitted by general electricity, 16% by cooling load and 16% by heating load. It is also proposed that the $CO_2$emission rate of cooling and heating load is profoundly pertinent to the variation of outdoor temperature.

  • PDF

Pre-Analysis Study on Ground Source Heat Pump System in Building with RETScreen (RETScreen을 활용한 건물에서의 지열 히트펌프 시스템 적용 사전 분석연구)

  • Kim, Yu Jin;Lee, Kwang-Seob;Lee, Euy-Joon;Kang, Eun-Chul
    • Journal of the Korean Solar Energy Society
    • /
    • v.40 no.2
    • /
    • pp.1-10
    • /
    • 2020
  • Korea government published renewable energy obligation policy that public building must be supplied some part of total consumption energy (2019: 27%, 2020: 30%). RETScreen is freely available global energy tool that developed by Canadian National Energy Laboratory to quantify energy saving to compare conventional system. This program can be performed energy modeling, cost analysis, greenhouse gas emission analysis and financial analysis. In this study, GSHP (Ground source heat pump) heating and cooling system were studied for the energy deliverly and ROI (Return On Investment) in an office building. Three cases were studied according to the number of HP (Heat pump) units for the 1,000㎡ office building located in Daejeon. Results indicated that the energy delivery of the case 1 (1 HP unit) covered 57% of the office building heating and cooling energy consumption. The case 2 (2 HP units) covered 87.8% and the case 3 (3 HP units) covered 96.8% of the office building energy consumption. The ROI of the case 1 indicated 7.9 years. While 8.2 years for the case 2 and 9.7 years for the case 3.

Building Energy Demand Models for Offices in Korea (업무용 건물의 에너지 부하 모델)

  • Park, Hwa-Choon;Chung, Mo
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.5
    • /
    • pp.1-7
    • /
    • 2009
  • Energy demands for offices in Korea are surveyed and analyzed to generate communicational models for simulations. Daily energy loads of 13 office buildings scattered in the 6 largest cities in the country are surveyed and analyzed based on energy consumption log sheets. Detailed hourly loads that are frequently required when a detailed operation simulation is performed are measured using remote data acquisition processes for 3 offices. The complete load demand models of electricity, cooling, heating and hot water are established by combining the daily and hourly patterns based on the statistical behavior of the hourly patterns.

Energy Efficiency Evaluation of Heating and Cooling Systems as Space Program in Renovated Library (도서관의 공간사용 특성에 따른 냉난방설비 리모델링의 경제성 평가)

  • Park, Kang-Hyun;Cha, Jung-Hoon;Kim, Su-Min;Park, Kyung-Won
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.3
    • /
    • pp.205-211
    • /
    • 2012
  • Unlike the previous approaches, we analyzed for economic efficiency of renewed heating and cooling systems as the characteristics of space. The purpose of this study is to analysis the energy consumption and economical efficiency of absorption chillers and EHP systems in renovated library. It is important that equipment selection should be considering energy cost as well as space program. In recently, many EHP systems were installed in the building for reducing the energy cost and for seeking the convenience of individual control. In contrast, though absorption chillers have the disadvantage of a central control, absorption chillers are appropriate for the conditions of the library that needs simultaneous operation. The results by payback period method, show that selection of heating and cooling systems should be consider for space program and the characteristics of space.

The Performance Test and the Feasibility Study for a Dual-Source Heat Pump System Using the Air and Ground Heat Source (공기 및 지열 이용 Dual-Source 히트펌프 시스템의 성능실험 및 경제성 분석)

  • Nam, Yujin;Chae, Ho-Byung
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.5
    • /
    • pp.212-217
    • /
    • 2014
  • Recently, the use of renewable energy has been increased due to growing concern on the energy-saving at buildings and the reduction of $CO_2$ emission. In the field of architecture, to reduce the energy consumption of heating, cooling and hot water supply, heat pump systems with renewable energy has been developed and used in various applications. However, there have been many of researches on the large-scale commercial heat pump systems, but the research and the field application of a compact heat pump system is rare. Therefore, in order to develop the compact heat pump for the small-scale residential building, this study conducted the performance test and feasibility study for a hybrid heat pump using the heat source of air, solar and ground. In the results of experiments through a trial product, the average COP of cooling mode with ground heat source was 4.75, and it of heating mode was 4.03. Furthermore, the average COP of cooling mode with air heat source was 2.60, and it of heating mode was 2.92. Finally, payback period of the system was calculated as 9.2 years.

An overview of Geothermal heat pumps as energy efficient and environmental friendly systems

  • Ahmad, Bilal;Kim, Dong-Hwan;Bahk, Sae-Mahn;Park, Myung-Kyun
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.294-298
    • /
    • 2008
  • The major threats that human being is facing nowadays are the Climate change, depletion of the fossil fuels at a rapid rate and energy costs. A significant portion of world energy consumption is consumed by domestic heating and cooling. And heat pumps, due to their higher utilization efficiencies as compared to conventional heating and cooling systems, offer an attractive solution to this problem. Among the types of heat pumps, the Geothermal heat pump or Ground-source heat pump is a highly efficient, renewable energy technology for space heating and cooling. The Ground-source heat pump uses the Earth as a heat sink in the summer and a heat source in the winter. And the Earth, having a relatively constant temperature, warmer than the air in winter and cooler than the air in summer, offers an excellent heat source in winter and heat sink in summer.. This paper will discuss an overview of the types of heat pumps, its operation, benefits of using geothermal heat pumps, soil characteristics, and overview of some experimental works. Finally it will briefly discuss the opportunity of using these energy efficient systems (EES) in the HVAC market of South Korea.

  • PDF

An Analysis on Effects of Passive Heating of Low Energy House Using Heat in Greenhouse (온실의 열을 이용한 저에너지하우스의 패시브 난방 효과 분석)

  • Yoo, Dong-Wan;Lee, Tae-Goo
    • KIEAE Journal
    • /
    • v.16 no.5
    • /
    • pp.103-109
    • /
    • 2016
  • Purpose: In Korea, to reduce greenhouse gas emissions, energy performance standard of buildings is being reinforced with goals of Passive House until 2017 and Zero Energy House until 2025 in order to reduce emissions from buildings which constitute a quarter of greenhouse gas emissions. In order to achieve the target of Zero Energy House, it is certainly necessary to develop renewable energy that can replace cooling and heating energy occupying a significant amount of building energy consumption after increasing the energy performance firstly. Method: In this study, effects of heat in greenhouse heated by solar heating on indoor heating were analyzed by constructing a greenhouse in front of the Low Energy Building. Result: As a result, indoor temperature was increased by peak average $27.8^{\circ}C$, peak average $6.8^{\circ}C$ was increased from when heat in greenhouse has not been used for heating and indoor surface temperature was increased by average $5.1^{\circ}C$. It shows it can be possible to use heat in greenhouse for heating, if the heating effects can be same as this experimental result because Energy Saving-Type buildings such as Low Energy House or Passive House keep from 18 to $20^{\circ}C$ in winter. Therefore, even if energy supply is cut off by disasters and other reasons, cooling and heating can be possible for some time.

Economic Analysis of a Residential Ground-Source Heat Pump System (단독주택용 지열원 열펌프 시스템 경제성 분석)

  • Sohn, Byong-Hu;Kang, Shin-Hyung;Lim, Hyo-Jae
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.515-518
    • /
    • 2007
  • Because of their low operating and maintaining costs, ground-source heat pump(GSHP) systems are an increasingly popular choice for providing heating, cooling and water heating to public and commercial buildings. Despite these ad- vantages and the growing awareness, GSHP systems to residential sectors have not been adopted in Korea until recently. A feasibility study of a residential GSHP system was therefore conducted using the traditional life cycle cost(LCC) analysis within the current electricity price framework and potential scenarios of that framework. As a result, when the current residential electricity costs for running the GSHP system are applied, the GSHP system has weak competitiveness to conven- tional HVAC systems considered. However, when the operating costs are calculated in the modified price frameworks of electricity, the residential GSHP system has the lower LCC than the existing cooling and heating equipments. The calculation results also show that the residential GSHP system has lower annual prime energy consumption and total pollutant emissions than the alternative HVAC systems considered in this work.

  • PDF