• 제목/요약/키워드: Cooling equipment

Search Result 411, Processing Time 0.025 seconds

Study on the Standardization of a Surveillance Culture Laboratory in Infection Control Fields (감염관리 분야에서 감시배양검사의 표준화 연구)

  • Park, Chang-Eun;Jeong, Na-Yeon;Yang, Min-Ji;Kim, Han-Wool;Joo, Sei-Ick;Kim, Keon-Han;Seong, Hee-Kyung;Hwang, Yu-Yean;Lim, Hyun-Mi;Son, Jae-Cheol;Yoon, Sun-Han;Yoon, Nam-Seob;Jang, In-Ho
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.50 no.3
    • /
    • pp.359-369
    • /
    • 2018
  • An essential measure to prevent healthcare-associated infections (HAI) is to develop a consistent system of surveillance, thereby promoting a reliable situation diagnosis to perform efficient control for the problem. Patient-to-patient transmission of pathogens within the hospital plays a substantial role in the epidemiology of HAIs. Contamination of healthcare environments commonly occurs, including facilities surfaces (e.g., bed rails, bedside tables), drinking water, cooling tower water, endoscopic instruments, food, airborne, endotoxin test, sterile test and medical equipment, with pathogenic organisms. In addition, epidemiological analysis is performed by multi locus sequence tying, pulsed-field gel electrophoresis for active surveillance. Therefore, an environmental surveillance culture test for prevention improves patient safety and blocks infection agents. Effective infection control and increased safety are possible by controlling the national infection control system. In conclusion, this study contributes to an effective infection control system through the standardization of active surveillance culture laboratory and secure expertise as infection control specialist. The primary objective of the standardization is to improve the safety of the nation's healthcare system by reducing the rates of HAIs.

Dynamic Soil Properties of Frozen and Unfrozen Soils from Terra Nova Bay in Eastern Antarctica (동남극 테라노바만 흙 시료의 동결 및 비동결 상태에서의 동적특성 평가)

  • Kim, Jae-Hyun;Kwon, Yeong-Man;Park, Keunbo;Kim, YoungSeok;Kim, Dong-Soo
    • Journal of the Korean Geotechnical Society
    • /
    • v.33 no.3
    • /
    • pp.37-47
    • /
    • 2017
  • The geotechnical characteristics of frozen ground is one of the key design issues for the construction of infrastructure in cold region. In this study, the dynamic properties (shear modulus and damping ratio) of frozen and unfrozen soils sampled from Terra Nova Bay located in eastern Antarctica, where Jang Bogo station was built, were investigated using Stokoe-type resonant column test (RC). In order to freeze the reconstituted soil specimen, the RC testing equipment was modified by adding a cooling system. A series of resonant column tests were performed in frozen and unfrozen soils with various soil densities and temperatures. The shear modulus (G) and damping ratio (D) of soil frozen at $-7^{\circ}C$ were compared with those of unfrozen soil. In addition, the effect of temperature rise on the maximum shear modulus ($G_{max}$) and damping ratio was experimentally investigated. This study has significance in that the difference of dynamic soil properties between frozen and unfrozen soils and the effect of temperature rise on frozen soil were identified.

Design and fabrication of a high power LED searchlight (고출력 LED 탐조등의 설계 및 제작)

  • Kim, Se-Jin;Kim, Sun-Jae;Ha, Hee-Ju;Kil, Gyung-Suk;Kim, Il-Kwon
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.6
    • /
    • pp.737-743
    • /
    • 2014
  • This paper dealt with a retrofit high power LED searchlight to replace conventional 1kW halogen searchlights. The design specification meets KDS 6230-1046-1 and KS V 8469. An optical lens with the beam angle of $6^{\circ}$ was used to meet the luminous intensity of 800,000cd at $0^{\circ}$ in horizontal line. Heat dissipation of the LED searchlight adopted a free air cooling type which does not use a fan or a heat-pipe. From the test results, power consumption of the prototype LED searchlight was 148W which was saved by 85% comparing a halogen searchlight of 1kW. Luminous intensity was 945,000cd at $0^{\circ}$ in horizontal line, satisfying KS V 8469. Luminous efficacy was improved by 4.7 times higher than that of the halogen searchlights. Beam angle, color temperature, and color rendering index(CRI) was $5.4^{\circ}$, 5,500K, and 70, respectively. Surface temperature of the LED searchlight was below $60^{\circ}C$ and surrounding temperature of the SMPS installed inside was below $50^{\circ}C$ which were satisfied with the IEC 60092-306.

Experimental Study on the Explosion and Fire Risks of Mobile Phone Batteries (휴대폰 배터리의 폭발 및 화재 위험성에 관한 실험적 연구)

  • Lee, Ho-Sung;Kim, Si-Kuk
    • Fire Science and Engineering
    • /
    • v.30 no.4
    • /
    • pp.111-120
    • /
    • 2016
  • This is an experimental study to analyze the explosion and fire hazards of mobile phone batteries. Using the lithium-ion batteries currently used on smart phone as the experiment samples, the experiments were conducted by overcharging, internal and external short circuit, and thermal shock with the potential of explosion and fire caused by careless use or abnormal conditions. The experiment results showed that, in the case of overcharging and external short circuit, there was no explosion and fire hazard in the normal operation of the protection circuit module (PCM), but there were big risks when the PCM faulted conditions were assumed. In the case of the experiments by internal short circuit and thermal shock, such risks varied depending on a battery charge state. In other words, it could be verified that there were low risks of explosion and fire in a full discharge state, but there were high risks in a full charge state. These experiment results suggest that to minimize the explosion and fire hazards of mobile phone batteries, an alarm device is necessary when the PCM fault occurs. In addition, a solid battery case should be made and safety equipment, such as a cooling device to avoid high temperature, is needed.

A Study on the Calculation Method of Load standard for ZEB activation (ZEB 활성화를 위한 부하기준 산정 방법 연구)

  • Lee, Hangju;Kim, Insoo
    • Journal of Energy Engineering
    • /
    • v.26 no.4
    • /
    • pp.92-99
    • /
    • 2017
  • In Korea, the zero energy building was designated as the 7 new industries in the Ministry of Land and the 8 new industries in the Ministry of Industry. In order to maximize the insulation performance of the building envelope, improve the efficiency of building equipment, We are aiming. It is necessary to analyze the energy requirements of the buildings (cooling, heating, hot water supply, lighting, ventilation) of buildings with energy efficiency level of 1++ which is equivalent to the zero energy building certification system in Korea, It is aimed to be used as basic data for the advancement of energy building certification system. Zero Energy Building certification is estimated to be 61 buildings by 2017, and the approximate reference value and the first energy requirement for each of the five loads are calculated considering passive and active aspects. It is difficult to say that it is a clear standard because there is a small sample of data for calculating the load standard. However, it is necessary to interpret various methods in order to upgrade the Zero Energy Building certification standard in the future.

A Study on the Thermo-Mechanical Fatigue Loading for Time Reduction in Fabricating an Artificial Cracked Specimen (열-기계적 피로하중을 받는 균열시편 제작시간 단축에 관한 연구)

  • Lee, Gyu-Beom;Choi, Joo-Ho;An, Dae-Hwan;Lee, Bo-Young
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.21 no.1
    • /
    • pp.35-42
    • /
    • 2008
  • In the nuclear power plant, early detection of fatigue crack by non-destructive test (NDT) equipment due to the thermal cyclic load is very important in terms of strict safety regulation. To this end, many efforts are exerted to the fabrication of artificial cracked specimen for practicing engineers in the NDT company. The crack of this kind, however, cannot be made by conventional machining, but should be made under thermal cyclic load that is close to the in-situ condition, which takes tremendous time due to the repetition. In this study, thermal loading condition is investigated to minimize the time for fabricating the cracked specimen using simulation technique which predicts the crack initiation and propagation behavior. Simulation and experiment are conducted under an initial assumed condition for validation purpose. A number of simulations are conducted next under a variety of heating and cooling conditions, from which the best solution to achieve minimum time for crack with wanted size is found. In the simulation, general purpose software ANSYS is used for the stress analysis, MATLAB is used to compute crack initiation life, and ZENCRACK, which is special purpose software for crack growth prediction, is used to compute crack propagation life. As a result of the study, the time for the crack to reach the size of 1mm is predicted from the 418 hours at the initial condition to the 319 hours at the optimum condition, which is about 24% reduction.

A Study on Energy Efficiency Improvement through Building Insulation Diagnosis (건축물 단열 진단을 통한 에너지 효율 개선에 관한 연구)

  • Cho, Kwangmoon
    • Journal of Internet of Things and Convergence
    • /
    • v.7 no.3
    • /
    • pp.9-14
    • /
    • 2021
  • This paper discovers the energy loss factors through the insulation diagnosis of houses or buildings, and proposes directions for energy efficiency improvement. The energy efficiency factor of a building consists of insulation diagnosis, thermal bridge diagnosis, window diagnosis, airtight diagnosis, and equipment diagnosis. Among the residents and facilities in the energy welfare blind spot, an energy efficiency diagnosis was conducted for one senior citizen building located in Naju-si, Jeollanam-do, and energy efficiency diagnosis was conducted after insulation was installed. Energy measurement, diagnosis and analysis were performed using the IoT-based integrated wired/wireless energy diagnosis platform, Energy Finder. As a result of comparison, an overall energy saving rate of 16.38% was achieved. Annual heating energy consumption per unit area decreased from 333.51kWh before construction to 277.35kWh after construction, and annual cooling energy consumption per unit area decreased from 5.51kWh before construction to 5.22kWh after construction. The annual primary energy consumption per unit area decreased from 464.52kWh before construction to 403.69kWh after construction, and the annual energy cost was reduced from 3,063,307.14 won before construction to 2,641,072.49 won after construction. The additional improvement work is needed on the standards affecting energy efficiency other than insulation.

A study on the Increase in Construction Cost for Zero Energy Building (제로에너지건축물의 공사비 증가분 산출에 관한 연구)

  • Shim, Hong-Souk;Lee, Sungjoo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.1
    • /
    • pp.603-613
    • /
    • 2021
  • As a core policy for achieving the goal of reducing greenhouse gas emissions in the building sector, Korea has enforced the mandatory certification of zero energy buildings for new public buildings from 2020. This study suggests energy-saving technologies and economic factors that building officials can refer to for decision-making on the implementation of zero energy buildings. For this study, the construction cost for the energy item of a building was analyzed by collecting the building energy efficiency level certification data and detailed construction cost statement data from public institutions for the last three years. Based on the building energy efficiency certification data, each energy item of the baseline building was derived, and the energy performance of the zero energy building was derived through repetitive simulations by gradually increasing the energy performance value of the baseline building. By applying the analyzed construction cost, the construction cost for each energy item of the baseline and zero energy buildings was derived. As a result, the lighting equipment contributed up to 10.5% energy savings, and the increase in construction cost of the cooling and heating system was at least 9.1%.

Study on the Specific Heat of Rough Rice and Barley (미맥(米麥)의 비열(比熱)에 관한 연구(硏究))

  • Kim, Man Soo;Chang, Kyu Seop
    • Korean Journal of Agricultural Science
    • /
    • v.7 no.2
    • /
    • pp.145-155
    • /
    • 1980
  • An engineering design of the machines and equipment for processing grain as well as an understanding of processing itself need the knowledge of thermal properties of grain. Thermal properties of grain are thermal conductivity, thermal diffusivity and specific heat. Knowledge of any two and the bulk density of grain enables the third to be calculated. Several workers have investigated these properties, with special emphasis on thermal conductivity and diffusivity. However, some information is available on the specific heat of rough rice and barley but it is available only for a foreign variety of grain and for as a function of moisture content only. The objectives of this study were to develop a model for the specific heat of rough rice and barley which were a staple products in Korea as a function of initial temperature, moisture content and porosity of grain with cooling curve method, and to analyze the effect of these factors on the specific heat of rough rice and barley. The results of this study are summarized as follows; 1. The specific heat was $1.8209-2.7041kJ/kg\;^{\circ}K$ for Naked barley, 1.8862-2.5625 k.l/kg K for Covered barley, $1.5167-2.3779kJ/kg\;^{\circ}K$ for Japonica rice and $1.5260-2.3981kJ/kg\;^{\circ}K$ for Indica rice. 2. The model for the specific heat of rough rice and barley as a function of initial temperature, moisture content and porosity of grain was developed. 3. Specific heat of rough rice was decreased with initial temperature, but specific heat of barley was increased with initial temperature. 4. On the whole specific heat of sample grain was increased with moisture content of grain. 5. Specific heat of the grain was found to decrease with porosity except Indica rice.

  • PDF

Development of a complex failure prediction system using Hierarchical Attention Network (Hierarchical Attention Network를 이용한 복합 장애 발생 예측 시스템 개발)

  • Park, Youngchan;An, Sangjun;Kim, Mintae;Kim, Wooju
    • Journal of Intelligence and Information Systems
    • /
    • v.26 no.4
    • /
    • pp.127-148
    • /
    • 2020
  • The data center is a physical environment facility for accommodating computer systems and related components, and is an essential foundation technology for next-generation core industries such as big data, smart factories, wearables, and smart homes. In particular, with the growth of cloud computing, the proportional expansion of the data center infrastructure is inevitable. Monitoring the health of these data center facilities is a way to maintain and manage the system and prevent failure. If a failure occurs in some elements of the facility, it may affect not only the relevant equipment but also other connected equipment, and may cause enormous damage. In particular, IT facilities are irregular due to interdependence and it is difficult to know the cause. In the previous study predicting failure in data center, failure was predicted by looking at a single server as a single state without assuming that the devices were mixed. Therefore, in this study, data center failures were classified into failures occurring inside the server (Outage A) and failures occurring outside the server (Outage B), and focused on analyzing complex failures occurring within the server. Server external failures include power, cooling, user errors, etc. Since such failures can be prevented in the early stages of data center facility construction, various solutions are being developed. On the other hand, the cause of the failure occurring in the server is difficult to determine, and adequate prevention has not yet been achieved. In particular, this is the reason why server failures do not occur singularly, cause other server failures, or receive something that causes failures from other servers. In other words, while the existing studies assumed that it was a single server that did not affect the servers and analyzed the failure, in this study, the failure occurred on the assumption that it had an effect between servers. In order to define the complex failure situation in the data center, failure history data for each equipment existing in the data center was used. There are four major failures considered in this study: Network Node Down, Server Down, Windows Activation Services Down, and Database Management System Service Down. The failures that occur for each device are sorted in chronological order, and when a failure occurs in a specific equipment, if a failure occurs in a specific equipment within 5 minutes from the time of occurrence, it is defined that the failure occurs simultaneously. After configuring the sequence for the devices that have failed at the same time, 5 devices that frequently occur simultaneously within the configured sequence were selected, and the case where the selected devices failed at the same time was confirmed through visualization. Since the server resource information collected for failure analysis is in units of time series and has flow, we used Long Short-term Memory (LSTM), a deep learning algorithm that can predict the next state through the previous state. In addition, unlike a single server, the Hierarchical Attention Network deep learning model structure was used in consideration of the fact that the level of multiple failures for each server is different. This algorithm is a method of increasing the prediction accuracy by giving weight to the server as the impact on the failure increases. The study began with defining the type of failure and selecting the analysis target. In the first experiment, the same collected data was assumed as a single server state and a multiple server state, and compared and analyzed. The second experiment improved the prediction accuracy in the case of a complex server by optimizing each server threshold. In the first experiment, which assumed each of a single server and multiple servers, in the case of a single server, it was predicted that three of the five servers did not have a failure even though the actual failure occurred. However, assuming multiple servers, all five servers were predicted to have failed. As a result of the experiment, the hypothesis that there is an effect between servers is proven. As a result of this study, it was confirmed that the prediction performance was superior when the multiple servers were assumed than when the single server was assumed. In particular, applying the Hierarchical Attention Network algorithm, assuming that the effects of each server will be different, played a role in improving the analysis effect. In addition, by applying a different threshold for each server, the prediction accuracy could be improved. This study showed that failures that are difficult to determine the cause can be predicted through historical data, and a model that can predict failures occurring in servers in data centers is presented. It is expected that the occurrence of disability can be prevented in advance using the results of this study.