• Title/Summary/Keyword: Cooling efficiency

Search Result 1,112, Processing Time 0.03 seconds

A Study on an experimental basis a use deodorize stink of food-waste in order to cooling dehumidification (냉각 제습에 의한 음식물 쓰레기 처리장치 악취제거에 관한 실험적 연구)

  • Park, I.S.;Kim, J.D.
    • Journal of Power System Engineering
    • /
    • v.12 no.1
    • /
    • pp.35-40
    • /
    • 2008
  • This paper presents an effective cooling dehumidification method to remove odorous gas from food-wastes. The odorous gases, such as Styrene, Ammonia, Hydrogen sulfide and Acetaldehyde, are produced in environments where temperature is $50\sim80^{\circ}C$ and humidity is $40\sim70%$. Under such conditions, experiments are performed reiteratively using experiment equipments. The effect of the cooling dehumidification is measured via measuring instrument, and this research is focused on improving efficiency. The effect of cooling dehumidification using measuring instrument is validated. At $80^{\circ}C$, four type of gases that was mentioned previously showed generally better cooling efficiency with a good result for a component concentration. Among them, hydrogen sulfide gas demonstrated the highest reduction of 50%.

  • PDF

An Experimental Study on Engine Cooling System Improvement (엔진 냉각 시스템 개선에 관한 실험적 연구)

  • Chon, M.S.;Hwang, Y.H.
    • Journal of ILASS-Korea
    • /
    • v.9 no.4
    • /
    • pp.77-82
    • /
    • 2004
  • This paper describes the improvement of engine cooling system. To improve engine cooling performance, the authors approached in two ways. One is to increase water pump performance, changing of impeller shape and lightening of material were carried out. The second one is cooling efficiency rise, which were investigated with head gasket coolant flow passage optimization with flow visualization technique. The test results show that water pump performance was increased effectively, reduction of pump drive torque, and increase of pump flow-rate and pressure rise. Gasket hole pattern optimization test results represent an optimized head coolant flow which stands cross flow from exhaust to intake port side and small vortex were removed.

  • PDF

A Study on Refrigeration Performance of Vehicle HVAC System for Sub-Cooling Improvement (서브쿨링향상을 위한 차량공조 시스템의 냉방성능에 관한 연구)

  • 박만재
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.12 no.1
    • /
    • pp.1-9
    • /
    • 2004
  • The general method which changes sub-cooling of refrigerant is to control the expansion valve in the state of mixing with liquid and gas phase. In this study, the performance of vehicle air conditioning system is to control either changing the expansion valve or adding the sub condenser. Therefore, this research finally is tested in case of the fourth test procedure, the second test was suitable for a valve opening area due to adjusting valve slope in comparison with the other test. The other test except for the second test happened to do liquid back due to the excessively liquified refrigerant into the system. In conclusion, the second test was appeared not to be influenced upon liquid back, and it is to expect positive performance by controlling an expansion valve. Therefore, it will be also useful to research for an increase of compressor efficiency Performance improvement of an air conditioner is to reinforce the suction performance of the evaporator and increase the sub-cooling, which make use of the sub-cooling system.

A Study on the Stack Temperature Profile of a Standing Wave Thermoacoustic Cooler (정재파 열음향 냉각기의 스택 온도구배에 대한 연구)

  • Paek, In-Su
    • The Journal of the Acoustical Society of Korea
    • /
    • v.28 no.1
    • /
    • pp.19-24
    • /
    • 2009
  • Investigations of the relation between the stack temperature profile of a standing wave thermoacoustic cooler and the cooling efficiency were performed. Based on the mathematical derivations using the Rott Equation, it was found that the temperature profile along the stack becomes nonlinear as the enthalpy flux passing through the stack increases. It was also found that such nonlinear temperature profiles lower the cooling efficiency. Simulations using a thermoacoustic simulation program called DELTAE showed that the nonlinear temperature profile occurs with a long stack and large cooling load.

A Study on the Solid-Liquid Separation of Cooling Water in Ships (선박용 냉각수의 고.액분리에 관한 연구)

  • Choi, M.S.;Kim, J.H.;Jo, D.H.;Han, W.H.;Kim, B.G.
    • Journal of Power System Engineering
    • /
    • v.7 no.4
    • /
    • pp.25-30
    • /
    • 2003
  • Hydrocyclone has been widely used for the solid-Liquid separation in many industrial sites because of its comparatively preferable applications that can be applied to wide-range panicle sizes. If seawater with impurities flows through pumps or heat exchanger, it might cause an decrease in efficiency of cooling system. In this paper, we have suggested solid methods of separating impurities from seawater in the cooling system by using a Hydrocyclone. The effects of design factors as solid concentration, cyclone inlet pressure, flow rate and diameter of underflow on the seperating performance of the Hydrocyclone were investigated. The results from the study are summarized as follows: 1) In proportion to the increase of solid concentration, the efficiency of solid-liquid separation is improved. 2) According as the cyclone inlet pressure increases the efficiency of separation is improved. Conclusively, this research suggested that the Hydrocyclone will be used as a pre-treatment system of cooling water in ships, and eventually prevent unexpected accidents in engine systems.

  • PDF

Turbine Cooling Design for the Development of High Efficiency Cooling Turbine (고온 고효율 냉각터빈 개발을 위한 냉각 설계 기술)

  • Cho, Hyung-Hee;Kim, Kyung-Min;Park, Jun-Su
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.675-676
    • /
    • 2011
  • To improve efficiency and allowable life of gas turbine, the proper cooling techniques are needed. It is required not only the basic research of variable cooling techniques but also analysis of real operating conditions when design the cooling system. From this analytical results, we can predict the thermal stress and allowable life. This design process is thermal design techniques that is the most foundational design techniques to improve the efficiency of gas turbine.

  • PDF

Analysis of Gas Cooling System for IR Window (적외선 윈도우용 가스식 냉각장치 해석 기법)

  • Hyun, Cheol-Bong;Goo, Nam-Seo;Kim, Jae-Young;Lee, Ho-Sung
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.15 no.2
    • /
    • pp.130-137
    • /
    • 2012
  • In this paper, a post-analysis of cooling system for infrared(IR) window was performed based on heating experiment of IR window system. We applied the same experimental conditions to analysis, and then validated the analysis technique by comparing numerical and experimental results. For an analysis software, we used a professional heat/fluid analysis program and the numerical and experimental results were in fairly good agreement. We investigated the effect of thermal transfer between the frame and IR window and also a cooling efficiency between fluid and structure in order to determine the proper parameters for the analysis. In this study, 100 % thermal transfer between the frame and IR window and 30 % cooling efficiency between fluid and structure have been proposed, which can be used in the future conceptual design and analysis of similar IR windows.

Recent Advances in Passive Radiative Cooling: Material Design Approaches

  • Heegyeom Jeon;Youngjae Yoo
    • Elastomers and Composites
    • /
    • v.59 no.1
    • /
    • pp.22-33
    • /
    • 2024
  • Passive radiative cooling is a promising technology for cooling objects without energy input. Passive radiative cooling works by radiating heat from the surface, which then passes through the atmosphere and into space. Achieving efficient passive radiative cooling is mainly accomplished by using materials with high emissivity in the atmospheric window (8-13 ㎛). Research has shown that polymers tend to exhibit high emissivity in this spectral range. In addition to elastomers, other materials with potential for passive radiative cooling include metal oxides, carbon-based materials, and polymers. The structure of a passive radiative cooling device can affect its cooling performance. For example, a device with a large surface area will have a greater amount of surface area exposed to the sky, which increases the amount of thermal radiation emitted. Passive radiative cooling has a wide range of potential applications, including building cooling, electronics cooling, healthcare, and transportation. Current research has focused on improving the efficiency of passive radiative cooling materials and devices. With further development, passive radiative cooling can significantly affect a wide range of sectors.

Study on Cooling Characteristics of the Tunnel Type Pressure Pre-Cooling System

  • Lee W. O.;Yun H. S.;Lee K. W.;Jeong H.;Cho K. H.;Cho Y. K.;Lee J. H.
    • Agricultural and Biosystems Engineering
    • /
    • v.4 no.2
    • /
    • pp.58-65
    • /
    • 2003
  • An understanding of the cooling requirements of horticultural commodities begins with adequate knowledge of their biological responses. All fresh horticultural products are living organisms, carrying on the many biological processes that are essential to the maintenance of life. The pre-cooling is essential technique for the construction of cold chain system, which is necessary to maintain marketing quality of fresh produces during the transportation and distribution. The purpose of this study is to develop the pressure cooling tunnel using conveyer for the reduction of labor and improvement of pre-cooling efficiency. Performance of developed facility was tested for the strawberries, tomatoes and Chinese cabbages. Cooling ratio as a result of pre-cooling efficiency was 1.57, 1.56 and 1.32 for strawberries, tomatoes, and Chinese cabbages respectively. Cooling ratio decreased with increasing the distance of heat conduction from surface to center. The cooling ratio of Chinese cabbages was lower than that of fruit because of its head and leaf. In aspect of cooling uniformity, there was no significant difference of final temperature among inlet, outlet and middle layers of cold air in fresh produces. After pre-cooling treatment, quality changes were measured for the weight loss, Vit. C content, and titratable acidity. The quality of pre-cooling treatment was better than that of non-treatment and was kept on well during long-term storage.

  • PDF

Analysis on the performance and internal flow of a tubular type hydro turbine for vessel cooling system

  • Chen, Zhenmu;Kim, Joo-Cheong;Im, Myeong-Hwan;Choi, Young-Do
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.10
    • /
    • pp.1244-1250
    • /
    • 2014
  • The temperature of the main engine cabin of commercial vessel is very high. The material SS-316L undergoes creep damage at temperatures exceeding $450^{\circ}C$. It is essential to maintain the highly stressed engine cabin below the creep regime. Hence, seawater is employed in this kind of maritime vehicles as cooling liquid. It obtains the thermal energy at the cooling pipe line after passing through main engine cooling system. To harness the energy in the seawater, a turbine can be installed to absorb the energy in the seawater before being released into the sea. In this study, a cooling pipe line is selected to apply the tubular type hydro turbine for transferring the energy. Numerical analysis for investigating the performance and the internal flow characteristics of the tubular turbine is conducted. The results show that the maximum efficiency of 85.8% is achieved although the efficiency drops rapidly at partial flow rate condition. The efficiency descends slowly at the condition of excess flow rate. There is a relatively wide operating range of flow rate of this turbine to keep high efficiency at the excess flow rate condition. For the internal flow of the turbine, there is uniform streamline on the suction and pressure sides of the blade at the design point. However, the secondary flow appears at the suction and pressure sidesat the excess flow rate.In addition, it appears only at pressure side at the partial flow rate condition.