• 제목/요약/키워드: Cooling efficiency

검색결과 1,121건 처리시간 0.03초

Analysis on the performance and internal flow of a tubular type hydro turbine for vessel cooling system

  • Chen, Zhenmu;Kim, Joo-Cheong;Im, Myeong-Hwan;Choi, Young-Do
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제38권10호
    • /
    • pp.1244-1250
    • /
    • 2014
  • The temperature of the main engine cabin of commercial vessel is very high. The material SS-316L undergoes creep damage at temperatures exceeding $450^{\circ}C$. It is essential to maintain the highly stressed engine cabin below the creep regime. Hence, seawater is employed in this kind of maritime vehicles as cooling liquid. It obtains the thermal energy at the cooling pipe line after passing through main engine cooling system. To harness the energy in the seawater, a turbine can be installed to absorb the energy in the seawater before being released into the sea. In this study, a cooling pipe line is selected to apply the tubular type hydro turbine for transferring the energy. Numerical analysis for investigating the performance and the internal flow characteristics of the tubular turbine is conducted. The results show that the maximum efficiency of 85.8% is achieved although the efficiency drops rapidly at partial flow rate condition. The efficiency descends slowly at the condition of excess flow rate. There is a relatively wide operating range of flow rate of this turbine to keep high efficiency at the excess flow rate condition. For the internal flow of the turbine, there is uniform streamline on the suction and pressure sides of the blade at the design point. However, the secondary flow appears at the suction and pressure sidesat the excess flow rate.In addition, it appears only at pressure side at the partial flow rate condition.

중앙식 냉방 플랜트의 유량제어를 통한 에너지 절감에 관한 연구 (Flow Control of a Centralized Cooling Plant for Energy Saving)

  • 이정남;김영일;정광섭
    • 에너지공학
    • /
    • 제24권3호
    • /
    • pp.48-54
    • /
    • 2015
  • 중앙집중식 냉방 시스템을 적용하고 있는 대형 빌딩이나 플랜트 설비들의 경우 부하 증설 및 피크부하에 대응하기 위한 여유율을 반영한 설비 설계 및 시공이 이루어지고 있다. 이는 부분부하가 걸리는 기간 동안에는 설비의 저부하 운전으로 인한 장비의 효율 저하와 에너지 과소비의 원인이 된다. 본 연구는 부분부하에 효율적으로 대응할 수 있도록 냉방플랜트 최적 유량제어를 통한 에너지 절감 방안에 대한 연구로서 냉방플랜트 에너지 성능 분석 프로그램을 이용하여 냉방 부하를 분석하고, 최적 유량제어 시스템을 제안하여 그 에너지 성능을 비교 평가하는 것을 목적으로 한다. 성능 분석 결과 냉방플랜트 최적 유량제어 시스템 적용 시 기존 에너지 사용량 대비 약 17%의 전기에너지 절감이 가능하였다.

냉각공기 예냉각을 통한 가스터빈 설계변수 변화에 의한 복합발전시스템 성능향상 분석 (Analysis of Performance Enhancement of a Combined Cycle Power Plant by the Change of Design Parameters of Gas Turbine Using Coolant Pre-cooling)

  • 권현민;김동섭;강도원;손정락
    • 한국유체기계학회 논문집
    • /
    • 제19권5호
    • /
    • pp.61-67
    • /
    • 2016
  • Turbine blade cooling is one of the major technologies to enhance the performance of gas turbine and combined cycle power plants. In this study, two cases of coolant pre-cooling schemes were applied in combined cycle power plant: decrease of coolant mass flow needed to cool turbine blade and increase of turbine inlet temperature (TIT). Both schemes are benefited by the decrease of coolant temperature through coolant pre-cooling. Under the same degree of pre-cooling, increasing TIT exhibits larger plant power boost and higher plant efficiency than reducing coolant flow. As a result, the former produces the same gas turbine power with a much smaller degree of pre-cooling than the latter. Another advantage of increasing TIT is a higher plant efficiency. Even with an assumption of partial achievement of the theoretically predicted TIT, the method of increasing TIT can provide considerably larger power output.

축냉시스템의 산업용 생산설비 적용에 대한 고찰 (Study on TES system application for industrial production facility)

  • 박창현;홍승수;김종률;박승상;황형식
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1288-1293
    • /
    • 2009
  • The TES (Thermal Energy Storage) cooling system utilizing cheaper off-peak electricity has been applied just for building air-conditioning currently and causes limitation of usage rate and inefficiency of national resources utilization. In this regard, more says the necessity to apply TES system in industrial cooling system which is longer using period and wider usage. In this study, we will approve the technical and economical improvement in efficiency of industrial cooling system applied TES system by utilizing cheaper off-peak electricity and it will attribute the promotion of TES system and stabilization of supply and demand of electric power by proving the necessity to develop more efficient industrial cooling system by combining TES system.

  • PDF

열전소자를 이용한 BIPV 모듈의 냉각시스템 개발 (Cooling System Development of BIPV Module Using Thermoelectron)

  • 최정식;고재섭;정동화
    • 전기학회논문지
    • /
    • 제57권9호
    • /
    • pp.1555-1562
    • /
    • 2008
  • This paper presents a cooling system using thermoelectron for improving the output of BIPV module. The temperature characteristic in regard to improving the output of BIPV system has rarely been studied up to now but some researchers only presented the method using a ventilator. The cooling system efficiency of BIPV module applied to a ventilator mainly depends on the weather such as wind, insolation etc. Because the cooling system of BIPV module using a ventilator is so sensitive, that is being set off by wind speed at all time but is unable to operate in the NOCT(Nominal Operating Cell Temperature) which is able to make the maximum output. The paper presents the cooling system using thermoelectron so as to solve such problems. The temperature control of thermoelectron can be controlled independently in the outside environment because that is performed by micro-controller. The temperature control of thermoelectron, also, can be operated around NOCT through algorism of the temperature control. Therefore, outputs of the whole system increase and the efficiency rises. The paper demonstrates the validity of proposed method by comparing the data obtained through a experiment of the cooling method of BIPV using a ventilator and proposed thermoelectron.

HILS 기반의 수중체 냉각 시스템 개선 (Improvement of Submarine Cooling System using HILS Simulation)

  • 정성영;오진석
    • 대한조선학회논문집
    • /
    • 제49권5호
    • /
    • pp.376-383
    • /
    • 2012
  • Owing to rapid development of power device and inverters, most of submarines adopt an eletric propulsion system. Although PMPM(Permanent Magnet Propulsion Motor) propulsion system has relatively higher power, energy conversion efficiency and smaller volume than engine propulsion system, it also produces large amount of heat due to current flowing inside motor coils and change of magnetic field induced by iron core. The produced heat in stator and inverter largely affects motor efficiency and bearing lubrication and causes thermal aging while the system is on operation. So, we analyze the existing cooling system and submarine ESS (Energy Saving System) cooling system whose power consumption is reduced. HILS(Hardware In the Loop System) technique is used for the modelling of the submarine cooling system. To confirm the ESS cooling system characteristic, HILS is simulated using LabVIEW with hardware. As a result, the ESS cooling system has the characteristic of better temperature stability and less power consumption than the existing one.

초음속 주유동 환경에서의 막냉각 특성 시험 연구 (An Experimental Study of Film Cooling Characteristics at Supersonic Free Stream Conditions)

  • 김만식;이동민
    • 한국항공우주학회지
    • /
    • 제45권4호
    • /
    • pp.342-348
    • /
    • 2017
  • 본 연구에서는 초음속 주유동 환경에서의 막냉각 특성에 대해 적외선 열상법을 적용한 시험을 수행하였다. 막냉각 시험은 수축형 막냉각 노즐을 갖는 쐐기형 막냉각 시편을 이용해 마하수 3.0, 단위 길이 당 레이놀즈수 $42.53{\times}10^6$$69.35{\times}10^6$ 인 조건을 구현한 자유-제트 시험 설비에서 수행하였다. 모사 탐색창에 해당하는 PEEK의 표면 온도를 계측하여 막냉각 효율을 산출하였고 받음각 및 분사율이 막냉각 효율에 미치는 영향을 분석하였다. 막냉각을 적용하지 않는 경우와 비교할 때, 막냉각을 적용할 경우 측정된 PEEK의 표면 온도가 크게 감소하였다. 막냉각의 유용성은 시간에 따른 PEEK의 표면 온도로부터 산출한 열유속 특성으로도 확인할 수 있다. 분사율이 증가할수록 보호되는 PEEK의 영역이 주유동과 막냉각 유동의 흐름 방향으로 확장되었다.

태양광 시스템의 냉각장치 개발 (Development of Solar Concentrator Cooling System)

  • 이희준;차귀수
    • 한국산학기술학회논문지
    • /
    • 제15권7호
    • /
    • pp.4463-4468
    • /
    • 2014
  • 태양광 모듈 효율의 증가를 위해 렌즈나 반사판 등을 이용한 집광 시스템 개발이 활발하게 진행되고 있으며, 집광장치는 일반적으로 렌즈를 사용하거나 고집속비의 광학장치를 이용하여 태양광 추적형으로 설계하여 고집속화를 추구하고 있다. 그러나 집속비에 비례하여 열로 소산되는 에너지 밀도가 증가하므로, 고집속에 따른 태양전지 온도상승에 의한 태양전지 효율 저하를 방지하기 위해 집광장치의 냉각에 유의해야 한다. 본 논문에서는 이러한 여러 가지 제약 조건을 피하여, 저가격의 반사형 광학장치를 이용한 경제적인 저집광형 태양광 모듈 시스템을 연구 개발하였다. 일반모듈에 저집광장치를 사용하여 태양광 모듈의 발전효율을 증대 시키면서 집광으로 인해 발생하는 열을 냉각장치를 통해 방출하였다. 제안된 저집광형 냉각장치(MCS, Micro Cooling System)의 특징은 모세관력에 의한 자연 순환 방식으로서 외부 동력원이 불필요하며, 유체 상변환시의 잠열을 이용함으로써 고성능 냉각 구현이 가능하다. 117W 태양광 모듈에 반사판을 설치하고 냉각장치가 있는 모듈과 냉각장치가 없는 모듈을 비교 하였다. 냉각장치를 설치한 모듈에서의 발전량이 28% 증가하였다.

페리미터존의 에어배리어 공조방식에 따른 실내 열환경 평가 (Evaluation of Indoor Thermal Environment According to Air-Barrier Air Conditioning System in Perimeter Zone)

  • 박병윤;함흥돈;손장열
    • 설비공학논문집
    • /
    • 제17권4호
    • /
    • pp.370-376
    • /
    • 2005
  • For the purpose of investigating the effective removal of heating/cooling load from light-weighted building envelope, two air-conditioning systems, conventional parameter air-conditioning system and air-barrier system, are evaluated and compared by both experiment and simulation with six different cases during heating and cooling season. In addition, the characteristics of window-side building thermal load are assessed by varying supply air velocity in order to seek the optimal system operation condition. The results are as follows. 1) Air-barrier system is more effective to remove heating/cooling load at perimeter zone than conventional parameter air-conditioning system. Moreover, the better effectiveness appears during cooling season than during heating season. 2) The experiment during cooling season provides that indoor temperature of air-barrier system shows $1^{\circ}C$ less than that of the conventional system with similar outdoor air temperature profile, and indoor temperature distribution is more uniform throughout the experimented model space. It concludes that air-barrier system can achieve energy saving comparing to the conventional system. 3) The capturing efficiency of air-barrier system is 0.47 on heating season and 0.2 on cooling season with the same supply air volume. It results that the system performs effectively to remove building thermal load, moreover demonstrates high efficiency during cooling season. 4) The simulation results provide that capturing efficiency to evaluate the effective removal of building load from perimeter zone shows high value when supply air velocity is 1 m/s.

응집침전에 의한 제철공장 냉각수질향상 (Improvement of Cooling Water Quality by Coagulation and Sedimentation in Steel Mill)

  • 조관형;우달식;황병기;이선주;박덕원
    • 한국환경보건학회지
    • /
    • 제35권5호
    • /
    • pp.411-416
    • /
    • 2009
  • This study was initiated to improve the cooling water quality by chemical coagulation and sedimentation in steel mills. Due to the inefficient flocculation in the settling tanks of blast furnace cooling water systems, the solid particles in the cooling water overflow accumulate and clog the cooling system. To protect the cooling water system from such fouling, proper flocculants must be continuously used. Laboratory tests were performed for the indirect cooling water system of a plate mill. The batch test in the gas scrubbing cooling water system of a blast furnace showed that the proposed coagulant was more effective for the improvement of coagulation and sedimentation than the existing one. During the tests, cationic flocculants were more effective than use of only an anionic flocculant. The suggested combination of anionic and cationic flocculants can probably improve the turbidity removal efficiency of the cooling water. Proper control of the overflow rate by the designed residence time would help turbidity removal efficiency in the settling tank. In addition, the settling can be enhanced by adopting rapid and slow mixing alternatively. Scale problems in blast furnace cooling water system were reduced to some extent by efficient settling.