• Title/Summary/Keyword: Cooling ducts

Search Result 13, Processing Time 0.032 seconds

Thermal Analysis of Exhaust Diffuser Cooling Channels for High Altitude Test of Rocket Engine (로켓엔진 고공환경 모사용 디퓨져의 냉각 채널 열 해석)

  • Cho, Kie-Joo;Kim, Yong-Wook;Kan, Sun-Il;Oh, Seung-Hyub
    • Aerospace Engineering and Technology
    • /
    • v.9 no.2
    • /
    • pp.193-197
    • /
    • 2010
  • Water cooling ducts are installed in the exhaust diffuser for high altitude tests of rocket engine to protect diffuser from high-temperature combustion gas. The mass flow rate and pressure of cooling water is designed to prevent boiling of cooling water in the ducts. Therefore, the estimation of maximum temperature of duct wall is important parameter in design of cooling system, especially pressure of cooling water. The method for predicting maximum temperatures of duct walls with variation of coolant flow rates was derived theoretically.

A Study on the Performance of Cooling/Reheating System Using Polymer Heat Exchanger (폴리머 열교환기를 사용한 냉각/재가열 시스템의 성능에 관한 연구)

  • Kim, Jin-Hyuck;Yoo, Seong-Yeon;Han, Kyu-Hyun
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2154-2159
    • /
    • 2008
  • In conventional air-conditioning systems, when the circulated air from the air-conditioned space pass through the cooling coil in the air-conditioning system, the air is over-cooled to eliminate the moisture as well as to decrease the temperature. The purpose of this study is to test and evaluate performance of the cooling/reheating system which can save both cooling energy and reheating energy by exchanging heat between the cooled air and reheated air. Experimental apparatus consists of fan, ducts, polymer exchangers, cooling coil, electronic auxiliary heater and data acquisition system. Two types of polymer exchanger, plate type and dimple type, made of polypropylene for cooling/reheating system are designed. Heat transfer and dehumidification characteristics of system are tested. The results show that the energy saving is up to 40% in the range of present experimented conditions, and it decreases with increasing velocity, inlet temperature and specific humidity.

  • PDF

Quantitative Visualization of Outlet Flow of the Centrifugal Blower (원심 블로어 출구 유동의 정량적 가시화 연구)

  • Tu, Xin Cheng;Kim, Sung-Jun;Park, Seung Ha;Kim, Hyoung-Bum
    • Journal of the Korean Society of Visualization
    • /
    • v.12 no.1
    • /
    • pp.25-29
    • /
    • 2014
  • The outlet flow of the centrifugal blower were quantitatively visualized using particle image velocimetry. Because the centrifugal blower is one of the key parts of electric vehicle battery cooling system, the quantitative information of centrifugal blower is necessary to design and optimize the cooling system. The effect of different inlet flow condition to the outlet flow was investigated in this study. Two different inlet ducts were used. One is the straight inlet and the other is a bended one. The results clearly showed the outlet flow asymmetry in both inlet ducts. When the blower has the bended inlet, the flow rate decreases due to the increase of the head loss.

PIV Analysis of the Flow Inside a Home Refrigerator and the Design of a Higher Efficiency Cooling Duct (PIV 계측을 이용한 가정용 냉장고의 냉기 유동특성 파악과 고효율 냉기 유로 설계)

  • Choi, Jay-Ho;Cho, Sung-Ho;Nam, Young-Sok;Lee, In-Seop
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.405-409
    • /
    • 2001
  • An experimental analysis of the flow inside the refrigeration compartment of a home refrigerator was conducted in order to achieve better performances in terms of uniform temperature distribution and cooling speed. 2D PIV and stereoscopic PIV were used for the experiments on an actual-size refrigerator at operating conditions. Two CCD cameras were employed for a wider field of view in the measurement of the shelf, and stereoscopic PIV was used to measure the three velocity components at the various cooling duct outlets and the mean velocity fields were area-integrated to calculate the flow-rates. 50 to 100 instantaneous velocity fields were time averaged for the mean velocity fields. With the result of this analysis, a new cooling duct system was developed, with the refrigerator's cooling performance increasing 11% in terms of cooling speed, and 25% in temperature uniformity.

  • PDF

Experimental analysis of ventilation performance varying with duct shapes inside reefer container hold (냉동 컨테이너 적재부의 배관 형상에 따른 환기성능 실험)

  • Park, Il-Seouk;Park, Sang-Min;Lee, Dong-Jo;Seol, Sin-Su
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1710-1714
    • /
    • 2004
  • The analysis of ventilation performance varying with duct shapes in reefer container of scale-model has studied experimentally. Most container ships have ventilation system of which ducts extended to the bottom for the purpose of efficient exhausting of condensing heat from hold. However, the size of ducts is so over-long that it causes manufacturing troubles. In this study, for various types of duct, flow visualization using smoke and normalized temperature analysis are presented. Finally, the cooling performance are compared respectively.

  • PDF

Development of a New Correlation for the Heat Transfer Coefficient of Turbulent Supercritical Carbon Dioxide Flow (초임계 상태 이산화탄소 난류유동의 새로운 열전달계수 상관식 개발)

  • 임홍영;최영돈;김용찬;김민수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.4
    • /
    • pp.274-286
    • /
    • 2003
  • Numerical simulations are performed to investigate the turbulent convective heat transfer of the supercritical carbon dioxide flows in vertical and horizontal square ducts. The gas cooling process at the supercritical state experiences a sudden change in thermodynamic and transport properties. This results in the extraordinary variations of the heat transfer coefficients in the supercritical state, which are much different from those of single or two phase flows. Algebraic second moment closure which can include the effects of large thermophysical property variations of carbon dioxide and of buoyancy is employed to model the Reynolds stresses and turbulent heat fluxes in the governing equations. The previous correlations for the turbulent heat transfer coefficient for the supercritical carbon dioxide flows couldn't reflect the buoyancy effect. The present results are used to establish a new heat transfer coefficient correlation including the effects of large thermophysical property variation and buoyancy on in-duct cooling process of supercritical carbon dioxide.

Optimization of a straight fin heat sink in 3D LCos projector considering bypass flow and a flow barrier

  • Kim, Jin-Wook;Kim, Sang-Hoon;Lee, Seung-Gyu
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.1265-1268
    • /
    • 2009
  • In this paper, the effect of a flow barrier and bypass on the cooling performance for a straight fin heat sink is presented. Both side directions and upward direction of bypass are controlled using various ducts which have different width and heights. In addition, a flow barrier is used to control flow toward heat sink. Through experiments, the distance from leading edge of a heat sink to a flow barrier is varied for various bypasses under fixed volume flow rate condition. This study shows possibility to improve cooling performance when bypass and a flow barrier exist.

  • PDF

DESIGN, CONSTRUCTION AND ACOUSTIC PERFORMANCE OF A SOUND-POOOF ENCLOSURE FOR DIESEL GENERATOR-SET

  • Bansal, A.S.
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1994.06a
    • /
    • pp.662-667
    • /
    • 1994
  • This paper presents the design and construction details of a soundproof enclosure for housing 20 KVA diesel generator-set. As the generator had to be installed close to the hospital building, it was desirable to reduce the transmission of noise by housing the generator in such an enclosure. The diesel engine being an air cooled one, it was essential to supply fresh air into the enclosure for its cooling. Forced inflow of air is provided through an inlet duct located in such a way that the incoming fresh air is thrown close to the inlet of cooling fan of the engine. The high velocity air stream, which heats up while passing over the engine head, escapes to the atmosphere through a rectangular outlet duct with enlarges inlet that receives hot air from the engine. The air ducts were designed specially and have been provided with acoustic lining for sound absorption. The masonary enclosure has been provided with double glazed fixed windows and double doors. The exhaust pipe of the engine fitted with a muffler has been taken out through the enclosure wall facing away from the hospital. Acoustic performance studies conducted in terms of attenuation provided by the enclosure at different frequencies have also been presented and discussed. The noise control measures adopted for building the sound-proof enclosure have been found to be quite effective as the noise levels inside the hospital building are now within the acceptable limits.

  • PDF

A Characteristics of a Secondary flow in a Corner Section of Square Duct (정사각덕트의 코너부에서 이차유동 특성)

  • Joung, J.M.;Kim, J.H.;Yoo, Y.T.
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.753-758
    • /
    • 2000
  • Heat engine and fluid machinery in the plant have to linked with various ducts network and the corresponding design have to be concerned about effectiveness and stability of system of plant. To optimum control and design system concerning stability, economization, operating effectiveness we have to exact analysis flow properties of a duct applying to fluid machinery, heat exchanger, cooling machine, air conditioning equipment. therefore, it is necessary to research the duct, heat transfer equipment, for increasing overall effectiveness of air conditioning system by suggesting basic data of the duct resulting from organic research. So we can contribute to technical development of the duct. In case of speeding up the flow rate of the duct, lots of wave velocity components are occurred the value of boundary layer resulting from developing the boundary layer at both walls of duct.

  • PDF

Application of Cathodic Protection on Metallic Structure in Extremely Acidic Fluids

  • Chang, H.Y.;Yoo, Y.R.;Jin, T.E.;Kim, Y.S.
    • Corrosion Science and Technology
    • /
    • v.4 no.4
    • /
    • pp.140-146
    • /
    • 2005
  • Fossil fired power plant produces the electric energy by using a thermal energy by the combustion of fossil fuels as like oil, gas and coal. The exhausted flue gas by the combustion of oil etc. contains usually many contaminated species, and especially sulfur-content has been controlled strictly and then FGD (Flue Gas Desulfurization) facility should be installed in every fossil fired power plant. To minimize the content of contaminations in final exhaust gas, high corrosive environment including sulfuric acid (it was formed during the process which $SO_2$ gas combined with $Mg(OH)_2$ solution) can be formed in cooling zone of FGD facility and severe corrosion damage is reported in this zone. These conditions are formed when duct materials are immersed in fluid that flows on the duct floors or when exhausted gas is condensed into thin layered medium and contacts with materials of the duct walls and roofs. These environments make troublesome corrosion and air pollution problems that are occurred from the leakage of those ducts. The frequent shut down and repairing works of the FGD systems also demand costs and low efficiencies of those facilities. In general, high corrosion resistant materials have been used to solve this problem. However, corrosion problems have severely occurred in a cooling zone even though high corrosion resistant materials were used. In this work, a new technology has been proposed to solve the corrosion problem in the cooling zone of FGD facility. This electrochemical protection system contains cathodic protection method and protection by coating film, and remote monitoring-control system.