• Title/Summary/Keyword: Cooling characteristic

Search Result 382, Processing Time 0.03 seconds

The Analysis of the Heat Transfer Characteristic in a PDP Ventilation Chamber (PDP용 배기로내 열전달 현상에 관한 해석)

  • Park, Hyung-Gyu;Chung, Jae-Dong;Kim, Charn-Jung;Lee, Joon-Sik;Park, Heui-Jae;Cho, Young-Man;Cho, Hae-Kyun;Park, Deuk-Il
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.385-391
    • /
    • 2000
  • An analysis of the heat transfer in a PDP ventilation chamber has been conducted to investigate the required heat curve and temperature uniformity of the panels. Firstly, experiment in a test chamber has been carried out and compared with the unsteady 3D numerical simulation. Reasonable agreement was found, which suggested that the employed numerical model had its credibility in an actual PDP ventilation process. On this ground, tact-type heating/cooling system was analyzed. The panel temperature was more uniform in the $40^{\circ}C$ tact-type system than in the $80^{\circ}C$ one. Comparison of full simulation of a cart and simplified simulation of one panel shows the panel pitch, which is closely related to a production rate, can be also predicted.

  • PDF

Heat Transfer and Pressure Drop Characteristic of Plate Heat Exchanger with Corrugation Height for District Cooling System (지역냉방 시스템용 판형 열교환기의 주름높이에 따른 열전달 및 압력강하 특성)

  • Kwon, Oh-Kyung;Kim, Hyeon-Joong
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.7 no.2
    • /
    • pp.23-29
    • /
    • 2011
  • The objectives of this paper are to study the characteristics of heat transfer and pressure drop of the plate heat exchanger with corrugation height by numerical analysis. Plate heat exchanger of three types was designed, which was corrugation height 3.1mm, 2.8mm and 2.5mm. The plate heat exchanger was numerically investigated for Reynolds number in a range of 950~3,380. The temperatures of the hot side were performed at $14.5^{\circ}C$ while that of the cold side was conducted at $4.5^{\circ}C$. The results show that the performance of heat transfer coefficient for corrugation height 2.5mm increases about 9.5~17.1% compared to that of corrugation height 3.1mm. On the other hand, the performance of pressure drop for corrugation height 2.5mm is remarkably higher than that of corrugation height 3.1mm, about 65.7~86.0%.

Analysis of Cement Clinker Minerals According to Burning Conditions (광학현미경을 이용한 소성 조건별 시멘트 클링커 광물의 특성 변화)

  • Chu, Yong-Sik;Kim, In-Seob;Lee, Jong-Kyu
    • Journal of the Korean Ceramic Society
    • /
    • v.41 no.11
    • /
    • pp.819-825
    • /
    • 2004
  • The characteristic analysis of cement clinker using light microscope can evaluate not only the quality of cement but also making process. Thus this study analyzed clinkers having different burning conditions by reflective light microscope. As heating and cooling rates is decreased, alite and belite minerals grew and especially cooling rate had an effect on the growth of belite. Futhermore as the retention time in max. temperature got longer by twenty minutes, alite and belite minerals grew more about 5 $\mu\textrm{m}$. In the case of temperature 1400$^{\circ}C$ in max, the size of belite was suitable but alite was not suitable with the size of 10~15 $\mu\textrm{m}$.

The Effects of Additives on the Cooling Characteristic of a Clathrate Compound (포접화합물의 냉각특성에 대한 첨가제의 영향)

  • Kim Jin Heung;Chung Nak Kyu;Kim Suk Hyun;Kim Chang Oh
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.2
    • /
    • pp.125-130
    • /
    • 2005
  • This study was peformed to investigate the phase change temperature, the supercooling, the maintenance time of liquid phase and the change rate of volume of TMA 30 $wt\% clathrate compound with additives. TMA 30 $wt\% clathrate compound with additive was cooled at heat source temperature of $-6^{circ}C$. The additives are ethylene glycol and chloroform. Their concentration are 0.1$wt\% respectively. The experimental results showed that the phase change temperature was not affected by additives and this was average $5.3^{circ}C$. Also the supercooling and the maintenance time of liquid phase were decreased by additives. Especially, the average value of supercooling showed by $8.8^{circ}C$ and the maintenance time of liquid phase was by 19 minutes in the case of chloroform 0.1$wt\%. Additionally, the average change rate of volume showed by $1.26{\~}1.31\%$ according to additives and the volume was decreased by the phase change from liquid to solid.

Detection of Current Signal and Thermal Characteristics of Electric Fan Operated in Various Situations (선풍기의 운전 상황별 발열특성 및 전류신호 검출)

  • Kim, Doo-Hyun;Lee, Heung-Su
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.3
    • /
    • pp.20-27
    • /
    • 2014
  • Cooling equipment is the frequent occurrence of fire despite the absence of the heating element. National fire statistics in 2013 show that a total of 263 fires occurred in the cooling equipment and the number of electric fan has 145 fire cases. This is accounted for 55.1% of the whole. Electric fan is the electrical appliance that the heat is generated on the winding wire and the iron core. If such characteristic is not controled properly, fire would break out at the electric fan. also there is a gap filled with an insulator between connection terminals of the capacitor in the electric fan. But in case that the gap on the capacitor is covered with some conductive material such as dust, there would be a fire as well caused by electrical heating locally. Although many studies related with those have been conducted, electric fan fire is continuously occurred. In this study, thermal characteristics and current signal in various conditions such as the heat generation of windings including iron cores of the motor and the dielectric breakdown of terminals on the capacitor connected to the motor were detected. In order to measure the maximum temperature, "third level" wind velocity button was pushed and the time selection switch to "continuation" was set. Analyzed data would be available for the fire safety of the electric fan.

A Experimental Study on the Boiling Heat Transfer Characteristics of Nanofluids by the Size and Mixing Ratio of Graphene Particle (그래핀 입자의 크기와 혼합비율이 나노유체의 비등열전달에 미치는 영향에 대한 실험적 연구)

  • Park, Sung-Seek;Kim, Young Hun;Kim, Nam-Jin
    • Journal of the Korean Solar Energy Society
    • /
    • v.35 no.2
    • /
    • pp.53-62
    • /
    • 2015
  • Boiling heat transfer characteristic is very important in the various industries such as solar thermal system, power generation, heat exchangers, cooling of high-power electronics components and cooling of nuclear reactors. Therefore, in this study, boiling heat transfer characteristics such as critical heat flux (CHF) and heat transfer coefficient under the pool boiling state were tested using graphene nanofluids. Graphene used in this study, which have the same thermal conductivity but with different sizes. The experimental results showed that the highest the CHF and boiling heat transfer coefficient increase ratio for graphene nanofluids was at the 0.01 vol.%. At the present juncture, the CHF and boiling heat transfer coefficient increase ratio of the small-sized graphene nanofluids was higher than the large-sized graphene nanofluids.

Heat Transfer Characteristics depending on the Length of a Channel with Pin-Fin Array (핀-휜을 삽입한 채널의 길이에 따른 열전달 특성 변화)

  • Son, Young-Seok;Shin, Jee-Young;Lee, Sang-Rog
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.5
    • /
    • pp.418-425
    • /
    • 2007
  • The power consumption and heat generation in a chip increase as the components are miniaturized and the computing speed becomes faster. Therefore, suitable heat dissipation has become one of the primary limiting factors to ensure the guaranteed performance and reliable operation of the electronic devices. A pin-fin array which may be considered as a porous medium could be used as an alterative cooling system of the electronic equipment. The aim of the present study is to investigate the forced-convective heat transfer characteristics of pin-fin heat exchangers. Convective heat transfer through the pin~fin array is analyzed experimentally based on porous medium approach. The influence of the structure of the pin-fin array including the pin-fin spacing, the pin diameter and plate length on heat transfer characteristic is investigated and compared with the Previous analytical results and existing correlation equations. Nowadays, electronic and mechanical devices become smaller and smaller. In this sense, the main purpose of this study is to decide the optimum pin-fin arrangement to get similar heat transfer performance when the length of the existing cooling system is reduced as a half.

Study on the Performance Prediction Simulation of the Heat Pump System using Solar and Geothermal Heat Source (태양열 및 지열 이용 히트펌프 시스템의 성능예측 시뮬레이션에 관한 연구)

  • Nam, Yu-Jin;Gao, Xin-Yan
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.3
    • /
    • pp.75-81
    • /
    • 2014
  • Recently, the use of renewable energy has been attracted due to the interest in energy-saving and the reduction of CO2 emission. In order to reduce the energy consumption of the cooling and the heating in the field of the architectural engineering, heat pump systems using renewable energy have been developed and used in various applications. In many researches, integrated heat pump systems are suggested which use solar and geothermal heat as the heat source for cooling and heating. However, it is still difficult to predict the performance of the systems, because the characteristic of heat exchange in each system is complicated and various. In this system, the performance prediction simulation of the heat pump was developed using a dynamic simulation model. This paper describes the summary of the suggested systems and the result of the simulation. The average temperature of the heat source, heating loads and COP were calculated with the cases of different local conditions, different system composition and different operation time by TRNSYS 17.

Characteristic analysis and condenser design of gas helium circulation system for zero-boil-off storage tank

  • Jangdon Kim;Youngjun Choi;Keuntae Lee;Jiho Park;Dongmin Kim;Seokho Kim
    • Progress in Superconductivity and Cryogenics
    • /
    • v.25 no.4
    • /
    • pp.65-69
    • /
    • 2023
  • Hydrogen is an eco-friendly energy source and is being actively researched in various fields around the world, including mobility and aerospace. In order to effectively utilize hydrogen energy, it should be used in a liquid state with high energy storage density, but when hydrogen is stored in a liquid state, BOG (boil-off gas) is generated due to the temperature difference with the atmosphere. This should be re-condensed when considering storage efficiency and economy. In particular, large-capacity liquid hydrogen storage tank is required a gaseous helium circulation cooling system that cools by circulating cryogenic refrigerant due to the increase in heat intrusion from external air as the heat transfer area increases and the wide distribution of the gas layer inside the tank. In order to effectively apply the system, thermo-hydraulic analysis through process analysis is required. In this study, the condenser design and system characteristics of a gaseous helium circulation cooling system for BOG recondensation of a liquefied hydrogen storage tank were compared.

Heat/Mass Transfer and Friction Characteristic in a Square Duct with Various Discrete Ribs -In-Lined Gap Arrangement Ribs- (덕트내 요철의 단락위치 변화에 따른 열/물질전달 및 압력강하 특성 - 정렬 단락배열 요철 -)

  • Lee, Sei-Young;Choi, Chung;Rhee, Dong-Ho;Cho, Hyung-Hee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.11
    • /
    • pp.1640-1649
    • /
    • 2001
  • The present study investigates the effects of various rib arrangements on heat/mass transfer in the cooling passage of gas turbine blades. A complex flow structure occurs in the cooling passage with rib turbulators which promote heat transfer on the wall. It is important to increase not only the heat transfer rates but also the uniformity of heat transfer in the cooling passage. A numerical computation is performed using a commercial code to calculate the flow structures and experiments are conducted to measure heat/mass transfer coefficients using a naphthalene sublimation technique. A square channel (50 mm $\times$ 50 mm) with rectangular ribs (4 mm $\times$ 5 mm) is used fur the stationary duct test. The experiments focus on the effects of rib arrangements and gap positions in the discrete ribs on the heat/mass transfer on the duct wall. The rib angle of attack is 60°and the rib-to-rib pitch is 32 mm, that is 8 times of the rib height. With the inclined rib angle of attack (60°), the parallel rib arrangements make a pair of counter rotating secondary flows in the cross section, but the cross rib arrangements make a single large secondary flow including a small secondary vortex. These secondary flow patterns affect significantly the heat/mass transfer on the ribbed wall. The heat/mass transfer in the parallel arrangements is 1.5 ∼2 times higher than that in the cross arrangements. However, the shifted rib arrangements change little the heat/mass transfer from the inline rib arrangements. The gap position in the discrete rib affects significantly the heat/mass transfer because a strong flow acceleration occurs locally through the gap.