• 제목/요약/키워드: Cooling analysis

검색결과 2,901건 처리시간 0.031초

캘리포니아 표준테스트 방법을 사용한 전기냉방기기의 가스냉방기기 대체에 따른 편익비용분석 (Benefit-Cost Analysis in Accordance with Replacement of Electrical Cooling System by Gas Cooling System using the California Standard Test)

  • 박래준;송경빈;원종률
    • 전기학회논문지
    • /
    • 제61권12호
    • /
    • pp.1774-1781
    • /
    • 2012
  • There are some efforts to improve the performance of electrical heat pump(EHP) and replace it with an alternative cooling equipment such as gas engine-driven heat pump(GHP), a gas cooling equipment, in order to solve the problem of summer electricity supply through reducing the summer electricity peak. This paper analyzes cost-benefit in accordance with replacement of electrical cooling system by gas cooling system using california standard test and sensitivity analysis of some scenarios.

외기이용 하이브리드 냉각탑 성능해석 (Numerical Analysis on the Performance of a Outdoor Air Cooled Heat exchanger for Cooling Tower)

  • 김성일;이욱현;이계중;전원표
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2322-2327
    • /
    • 2008
  • This paper is to provide analysis model that can be used to investigate the improvement in energy efficiency for cooling tower by using fresh air. Numerical analysis of Air-cooled heat exchanger for single-phase flow with variations of outdoor air temperature has been performed. A complete set of correlations of the heat transfer in both refrigerant and air sides was employed for predicting the heat transfer rate. The numerical results derived from the correlations were verified with experimental results. The energy consumption for a hybrid cooling tower has been compared for variation of a outdoor air temperature. The results showed that the hybrid cooling tower in low outdoor temperature offers a significant improvement in energy efficiency. The thermal analysis aids significantly in the solution of the design problem of hybrid cooling tower.

  • PDF

굴삭기 냉각팬 성능해석 및 슈라우드 특성에 대한 실험적 연구 (Experimental Study of Cooling Fan Performance Analysis and Shroud Characteristics for an Excavator)

  • 이재석;정경남;김진영;이태경;강정원;심재구;손득균
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2597-2602
    • /
    • 2007
  • In this paper, the performance analysis is experimentally carried out in order to select the best cooling fan and shroud considering both cooling performance and noise reduction. 4 cooling fans have been tested in the fan tester and the real excavator. In order to obtain the performance of the cooling fans, flow capacity has been estimated by measuring flow velocity using a hot wire anemometer, and noise radiation has been also measured to estimate the fan noise. Characteristics of a box-type and a streamlined shroud have been examined by changing the immersion depth of cooling fans. Based upon the results, the best cooling fan is selected. Finally, the criterion to select the best cooling fan has been set up.

  • PDF

600kJ급 SMES용 전도냉각시스템 열해석 (Thermal analysis of the conduction cooling system for HTS SMES system of 600 kJ class)

  • 홍용주;염한길;박성제;김효봉;고득용
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.1959-1963
    • /
    • 2007
  • SMES systems need cryogenic cooling systems. Conduction cooling system has more effective, compact structure than cryogen. In general, 2 stage GM cryocoolers are used for conduction cooling of HTS SMES system. 1st stages of cryocoolers are used for the cooling of current leads and radiation shields, and 2nd stages of cryocoolers for HTS coil. For the effective conduction cooling of the HTS SMES system, the temperature difference between the cryocooler and HTS coil should be minimized. In this paper, a cryogenic conduction cooling system for HTS SMES is analyzed to evaluate the performance of the cooling system. The analysis is carried out for the steady state with the heat generation of the HTS coil and effects of the thermal contact resistance. The results show the effects of the heat generation and thermal contact resistance on the temperature distribution.

  • PDF

선상 가열시 수냉 효과를 고려한 강판의 변형 추정에 관한 연구 (The Estimation of Curvature Deformation of Steel Plates in Water Cooling Process after Line Heating)

  • 황보혁;양박달치
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2006년 창립20주년기념 정기학술대회 및 국제워크샵
    • /
    • pp.209-212
    • /
    • 2006
  • Line heating with water cooling is generally adapted process in the shipyards for the forming hull surface. The purpose of this paper is to develop a model of thermal deformation in water cooling process after the line heating. In order to simulate the cooling process, heat transfer analysis was performed by assuming the effects of water cooling as a negative heat-source. Experiment for the line heating with water cooling was performed for 9 models of plates in order to verify the cooling model. By using the suggested model for the water cooling process, it could be observed that the present method predict the plate deformations in the line heating more accurately.

  • PDF

진공확산접합을 이용한 형상적응형 냉각채널을 가진 화장품 용기용 사출금형의 제작 및 시험사출 (Fabrication and Testing of Injection Mold for Cosmetic Container with Conformal Cooling Channels Using Vacuum Diffusion Bonding)

  • 유만준;박종천
    • 한국기계가공학회지
    • /
    • 제19권3호
    • /
    • pp.92-98
    • /
    • 2020
  • In this study, an injection mold with conformal cooling channels was designed and manufactured for use in the production of a thick plastic cosmetic container that required high gloss surfaces. A cooling analysis verified the design of the conformal cooling channel for the cosmetic container, and also showed that the cooling efficiency was superior to that of the straight cooling channel. Slide cores designed with the conformal cooling channel were manufactured using the Layers Parting method and vacuum diffusion bonding. Subsequent test injection and quality inspection showed no problem in the appearance and dimensional accuracy of the produced product. The cycle time for product production was about 110 seconds, sufficient for mass production.

그린카용 인휠 모터의 냉각 성능에 관한 연구 (A Study on Cooling Performance of In-wheel Motor for Green Car)

  • 정정훈;김성철;홍정표
    • 한국자동차공학회논문집
    • /
    • 제20권1호
    • /
    • pp.61-67
    • /
    • 2012
  • The in-wheel motor used in green car was designed and constructed for an electric direct-drive traction system. It is difficult to connect cooling water piping because the in-wheel motor is located within the wheel structure. In the air cooling structure for the in-wheel motor, a outer surface on the housing is provided with cooling grooves to increase the heat transfer area. In this study, we carried out the analysis on the fluid flow and thermal characteristics of the in-wheel motor under the effects of motor speed and heat generation. In order to check the problem of heat release, the analysis has been performed using conjugate heat transfer (conduction and convection). As a result, flow fields and temperature distribution inside the in-wheel motor were obtained for base speed condition (1250 rpm) and maximum speed condition (5000 rpm). Also, the thermo-flow characteristics analysis of in-wheel motor for vehicles was performed in consideration of ram air effect. Therefore, we checked the feasibility of the air cooling for the housing geometry having cooling grooves and investigated the cooling performance enhancement.

엔진 냉각시스템 성능해석에 관한 연구 (The Study about the Performance-Analysis of a Automotive Engine Cooling System)

  • 신창훈;이승희;박원규;장기룡
    • 한국자동차공학회논문집
    • /
    • 제14권2호
    • /
    • pp.39-48
    • /
    • 2006
  • An engine cooling system affects overall performances of an engine which has been recently requested higher power in more confined engine room. The design of efficient cooling system demands a great effort to effectively correlate with each components, such as water jacket, radiator, coolant pump, cooling fan, etc. Thus, the aim of this study is to provide the design tool of the cooling system in the early design stage by enabling for the designer to accurately predict the engine cooling performances. This user-friendly design tool has various ways to assemble each components and control the running condition with related database. The present design tool was simulated and compared with experimental data. As a result, the inlet and outlet temperature of the radiator agree very well with experiments. It was concluded that the present design tool could be effectively used for the design of the engine cooling system.

액체로켓 연소기 재생냉각 채널 구조설계 (Structural Design of Liquid Rocket Thrust Chamber Regenerative Cooling Channel)

  • 류철성;정용현;최환석
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2005년도 제24회 춘계학술대회논문집
    • /
    • pp.134-138
    • /
    • 2005
  • 재생냉각형 액체로켓 연소기 챔버의 냉각 채널부의 상온상태의 구조설계와 검증시험을 수행하였다. 재생냉각 연소기 냉각 채널부에 사용하는 크롬동 합금의 상온 인장시험을 수행하여 재료의 탄소성 물성치를 확보하였으며 냉각 채널의 탄소성해석은 이 물성치를 이용하여 수행하였다. 해석결과의 검증을 위해서 평판형태의 냉각채널 시편을 제작하여 강도시험을 수행하였다. 탄소성 구조해석과 결과와 시편의 수압시험 데이터를 비교한 결과 구조해석과 시험이 약간의 차이는 있지만 비교적 잘 일치하였으며 채널의 단면 두께가 작기 때문에 제작상의 가공오차가 채널의 구조적인 안정성에 큰 영향을 미치는 것을 확인하였다.

  • PDF

재생냉각 연소실의 냉각성능 해석 (Cooling Performance Analysis of Regeneratively Cooled Combustion Chamber)

  • 조원국;설우석;조광래
    • 한국항공우주학회지
    • /
    • 제32권4호
    • /
    • pp.67-72
    • /
    • 2004
  • 경험식을 이용한 1차원 해석에 의하여 30톤급 재생냉각 연소기의 냉각 유로 설계를 수행하였다. 1차원 해석에 의한 벽온도는 3차원 CFD 해석과 비교하여 약 100 K의 온도차이를 보였다. 동일한 냉각성능을 유지하면서 냉각 채널의 최대 폭이 4mm 와 2mm인 두 가지 설계안을 제시하였다. 냉각유체의 압력강하는 20% 증가할 것으로 예측되었다. 열차 폐 코팅과 탄소 침착물의 열저항을 고려한 경우, 최대 벽온도는 700K로 예측되었다. 본 연구에서 제시한 냉각 방법은 용량이 부족한 것으로 판단되는 바 막냉각이 추가적으로 적용되어야 할 것으로 판단된다.