빙축열 시스템의 지능형 냉방부하예측에 관한 연구 (The Study on Intelligent Cooling Load Forecast of Ice-storage System)

  • 고택범
    • 전기학회논문지
    • /
    • 제57권11호
    • /
    • pp.2061-2065
    • /
    • 2008
  • In the conventional operation of ice-storage system based on operator's experience and judgement, the failure in forecast of cooling load occurs frequently due to operator's misjudgement and unskilled operation. This study presents the method of constructing self-organizing fuzzy models which forecast tomorrow temperature, humidity and cooling load periodically for economic and efficient operation of ice-storage system. To check the effectiveness and feasibility of the suggested algorithm, the actual example for forecasting temperature, humidity and cooling load of ice- storage system in KEPCO training institute, Sokcho, is examined. The computer simulation results show that the accuracy of temperature, humidity, cooling load forecast of the suggested algorithm is higher than that of the conventional methods.

동적 계획법을 이용한 냉방시스템 최적운전에 관한 연구 (A Study on Optimal Operation of Cooling System Using Dynamic Programing)

  • 유성연;한규현;이제묘;이일수
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1061-1064
    • /
    • 2009
  • The objective of this study is to find the optimal operational planning of the hybrid cooling system, which is combined by ice storage system and the absorption chiller. The optimization technique used in this study is dynamic programming. The objective function is summed cost during a day including charge and discharge periods of ice storage system and operation time of absorption chiller. Assuming that initially ice storage tank is stored fully and the cooling load is perfectly predicted for the operational planning. This method provides the most efficient and economic combination of equipment operational planning for cooling with respect to energy consumption cost.

  • PDF

인버터형 멀티 히트펌프의 냉난방 운전특성에 대한 실험연구 (Experimental Study on Cooling and Heating Operation Characteristics of Inverter type Multi-Heat Pump)

  • 박병권;서동남;엄유식;권영철;고국원
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.618-622
    • /
    • 2007
  • In the present study, the cooling and heating operation characteristics of a multi-heat pump have been experimentally investigated for the number of the indoor units(A, B, C) and the operating conditions. The heat pump was controlled by an inverter scroll compressor. The performance of the heat pump was measured by the multi-calorimeter of an air enthalpy method. Cooling and heating capacities and COPs were obtained at the cooling and heating temperature conditions and the setting temperatures of an indoor unit. With increasing the operation frequency of the compressor, the cooling and heating capacities of the heat pump increased linearly. The operation frequency region of the compressor was different as the combination of the indoor unit and the cooling/ heating condition.

  • PDF

원유펌프시스템의 열전달해석 및 냉각설계 (Heat Transfer Analysis and Cooling Design for Crude Oil Pump System)

  • 김완기;이준엽;권중록;김해천
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2017-2022
    • /
    • 2008
  • The crude oil pump system is the equipment for transporting crude oil and it consists of 3 major components, a motor and an impeller which discharge underground crude oil, a pipestack that transmits the cooling oil and power, and a cooling oil unit & junction box that provides cooling oil and electric power. When considering the system characteristics that it has to be installed at a depth of deeper than 100 m, a design technology for the efficient control of the heat occurring at a conductor and motor is necessary and it is the essential factor for ensuring system durability. In this paper, therefore, cooling oil flow has been calculated to satisfy the limit value of the system temperature by analyzing heat flow considering the related losses such as loss of conductor, contact resistor loss at the conductor connection, and operation loss of motor. And the operation temperature has been set up based on the temperature of crude oil and the heat of motor and conductor. Also, a design for cooling of crude oil pump system has been proposed by calculating the operation pressure loss and selecting the capacity of a cooling oil pump and a heat exchanger.

  • PDF

가변용량 압축기를 적용한 에어컨의 냉방운전 시 응축 및 증발온도 특성 (Temperature characteristics of condenser and evaporator of Air-conditioner applying variable capacity compressor under cooling condition)

  • 권영철;전종균
    • 한국산학기술학회논문지
    • /
    • 제8권6호
    • /
    • pp.1325-1331
    • /
    • 2007
  • 본 연구에서는 냉방운전 시 가변용량방식의 압축기를 적용한 시스템 에어컨의 냉방능력과 증발기 및 응축기의 온도특성을 조사하기 위해 압축기 운전율(10가지)과 실내외 온도(16가지)의 변화에 따른 시스템의 운전특성을 실험적으로 조사하였다. 시스템의 운전특성은 칼로리미터를 이용하여 측정되었다. 냉방능력은 실외온도가 낮아질수록 실내온도가 증가할수록 더 큰 값을 그리고 압축기 운전율이 증가할수록 냉방능력은 선형적으로 증가하였다. 응축온도는 실외온도 변화에 증발온도는 실내온도 변화에 더 민감하였다. 또한 압력-엔탈피선도를 이용하여 사이클의 운전특성을 분석하였다.

  • PDF

냉각탑을 이용한 축열식 히트펌프시스템의 성능측정에 관한 연구 (A study on performance test of water heat storage type heat-pump system using cooling tower heat source)

  • 이상훈;박효식;한우용;김욱중
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.1099-1104
    • /
    • 2008
  • Recent year, mean energy consumptions of a people are higher than other country. And international oil price became over 120 dollar. This energy environment as well as energy war. Maybe, the Meteorological Administration is going to enforce scorching heatwave special report system from that come summer. Besides, 2008 summer, maximum demand power is expected by 64,240,000kW. The electric power equipment reserve rate appeared in to keep 12.5% level. Chilled water storage system witch is one of electric load administration system. Heat pump system used cooling tower heat recovery is advantage that use is possible to summer in small a public bath building. In this paper, we suggest that heat pump system by heat recovery using cooling tower when it is heating operation of ambient air temperature. To apply cooling tower heat recovery heat pump to chilled water heat storage type and achieved performance evaluation about operation. As a result, performance of heat pump system that about 121% in cooling mode, 138% in heating mode higher than KEPCO standard. And heating operation possible to ambient air temperature about $23^{\circ}C$, which of appear cooling tower outlet temperature about $13^{\circ}C$.

  • PDF

흡수식 냉온수기의 부분부하에 따른 냉각수 변유량시 성능특성에 관한 연구 (A Study on the Performance Characteristics of an Absorption Chiller for Variable Cooling Water Flow Rate at Partial Load Conditions)

  • 박찬우;조현철;강용태
    • 설비공학논문집
    • /
    • 제16권1호
    • /
    • pp.26-33
    • /
    • 2004
  • In general, an absorption chiller or heat pump is operated under the constant cooling water flow rate condition even though the system works with a partial load. The objective of this paper is to study the effect of the cooling water flow rates and the temperature of cooling water on the system performance to find the energy saving methode for the partial load operation of the double effect $H_2O$/LiBr absorption chiller. It is found that the performance of the system is sensitive to the temperature of cooling water than the cooling water flow rate, so the decrease of the performance due to reducing the cooling water flow rate can be overcome with the reduction of the cooling water temperature by 1$^{\circ}C$. The flow rate of the cooling water flow rate ranges from 50% to 100% of the flow rate at normal conditions with a partial load. It is also found that the operation cost of the cooling water pump and the cooling tower can be reduced by 23%.

냉매 저장방식에 의한 쾌속 냉각장치에 대한 실험적 연구 (Experimental Study on the Rapid Cooling System by Refrigerant Storage Method)

  • 장기태;고준석;정상권
    • 설비공학논문집
    • /
    • 제15권11호
    • /
    • pp.937-942
    • /
    • 2003
  • In the present study, low-temperature low-pressure refrigerant storage method is proposed to achieve higher cooling capacity during a short period of time than that of a compressor in steady operation. Experimental apparatus was designed and set up to analyze the performance of the new-conceptual cooling system. Two reservoirs for sequential storage of refrigerant were used in the cooling system. Several on/off solenoid valves were installed for control of refrigerant flow. From the experimental results, the initial rapid cooling by low temperature low-pressure refrigerant storage method was ascertained for successful operation. This rapid cooling methodology shall be useful for other low-capacity refrigeration system.

냉방주체 운전모드에서 동시냉난방 열펌프 성능향상에 관한 실험적 연구 (Experimental Study on the Performance Improvement of a Simultaneous Heating and Cooling Heat Pump in the Cooling-main Operating Mode)

  • 정현준;주영주;강훈;김용찬;최종민
    • 설비공학논문집
    • /
    • 제20권5호
    • /
    • pp.314-320
    • /
    • 2008
  • The cooling load in winter is significant in buildings and hotels because of the usage of office equipments and the improved wall insulation. Hence, a multi~heat pump is required to cover heating and cooling simultaneously for each indoor unit. In this study, the operating characteristics and performance of a simultaneous heating and cooling heat pump in the cooling-main operating mode were investigated experimentally. The system adopted a variable speed compressor using R410A with four indoor units and one outdoor unit. In the cooling-main mode, the heating capacity decreased due to reduction of flow rate to the indoor unit under heating mode operation. The EEV opening was adjusted to increase flow rate to the indoor unit under heating mode operation. The total capacity and COP in the cooling-main mode increased by 20.5% and 29.2%, respectively, compared with those in the cooling-only mode.

Simulation and transient analyses of a complete passive heat removal system in a downward cooling pool-type material testing reactor against a complete station blackout and long-term natural convection mode using the RELAP5/3.2 code

  • Hedayat, Afshin
    • Nuclear Engineering and Technology
    • /
    • 제49권5호
    • /
    • pp.953-967
    • /
    • 2017
  • In this paper, a complete station blackout (SBO) or complete loss of electrical power supplies is simulated and analyzed in a downward cooling 5-MW pool-type Material Testing Reactor (MTR). The scenario is traced in the absence of active cooling systems and operators. The code nodalization is successfully benchmarked against experimental data of the reactor's operating parameters. The passive heat removal system includes downward water cooling after pump breakdown by the force of gravity (where the coolant streams down to the unfilled portion of the holdup tank), safety flapper opening, flow reversal from a downward to an upward cooling direction, and then the upward free convection heat removal throughout the flapper safety valve, lower plenum, and fuel assemblies. Both short-term and long-term natural core cooling conditions are simulated and investigated using the RELAP5 code. Short-term analyses focus on the safety flapper valve operation and flow reversal mode. Long-term analyses include simulation of both complete SBO and long-term operation of the free convection mode. Results are promising for pool-type MTRs because this allows operators to investigate RELAP code abilities for MTR thermal-hydraulic simulations without any oscillation; moreover, the Tehran Research Reactor is conservatively safe against the complete SBO and long-term free convection operation.