• 제목/요약/키워드: Cooling Mode

검색결과 323건 처리시간 0.022초

냉방주체 운전모드에서 동시냉난방 열펌프 성능향상에 관한 실험적 연구 (Experimental Study on the Performance Improvement of a Simultaneous Heating and Cooling Heat Pump in the Cooling-main Operating Mode)

  • 정현준;주영주;강훈;김용찬;최종민
    • 설비공학논문집
    • /
    • 제20권5호
    • /
    • pp.314-320
    • /
    • 2008
  • The cooling load in winter is significant in buildings and hotels because of the usage of office equipments and the improved wall insulation. Hence, a multi~heat pump is required to cover heating and cooling simultaneously for each indoor unit. In this study, the operating characteristics and performance of a simultaneous heating and cooling heat pump in the cooling-main operating mode were investigated experimentally. The system adopted a variable speed compressor using R410A with four indoor units and one outdoor unit. In the cooling-main mode, the heating capacity decreased due to reduction of flow rate to the indoor unit under heating mode operation. The EEV opening was adjusted to increase flow rate to the indoor unit under heating mode operation. The total capacity and COP in the cooling-main mode increased by 20.5% and 29.2%, respectively, compared with those in the cooling-only mode.

동시냉난방 열펌프 시스템의 냉방전용 및 냉방주체 운전모드에서의 실내기온 변화에 따른 성능특성에 관한 실험적 연구 (An Experimental Study on the Performance of a Simultaneous Heating and Cooling Heat Pump in the Cooling-only and Cooling-main Operation Mode with the Variation of the Indoor Air Temperature)

  • 안재환;주영주;강훈;정현준;김용찬;최종민
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2165-2170
    • /
    • 2008
  • The cooling load in winter season is significant in many commercial buildings and hotels because of the usage of office equipments and the high efficiency of wall insulation. Therefore, the development of a multi-heat pump which can cover heating and cooling simultaneously for each indoor unit is required. In this study, the characteristics and performance of a simultaneous heating and cooling heat pump in the cooling-only and cooling-main operating mode was investigated experimentally with a variation of indoor air dry bulb temperature which is from $21^{\circ}C$ to $35^{\circ}C$. EEV opening was adjusted from 20% to 24% during the tests. When the indoor air temperature varied, the performance in the cooling-only mode was more sensitive to the temperature than in the cooling-main mode. The total capacity and COP were increased by 53.8% and 48.1%, respectively, in the cooling-main, while those were increased by 19.6% and 19.3% in the cooling-only mode. The performance differences between the two operating modes became larger at lower temperatures, especially for the COP.

  • PDF

동시냉난방 히트펌프의 냉매 충전량과 운전모드 변화에 따른 성능특성에 관한 연구 (The Performance of a Simultaneous Heat and Cooling Heat Pump at Various Charging Conditions)

  • 송인식;최종민;주영주;정현준;강훈;김용찬
    • 설비공학논문집
    • /
    • 제20권7호
    • /
    • pp.492-499
    • /
    • 2008
  • The cooling load in winter is significant in many commercial buildings and hotels because of the usage of office equipments and the high efficiency of wall insulation. The development of a multi-heat pump that can cover heating and cooling simultaneously for each indoor unit is required. In this study, the performance of a multi-heat pump with 3-piping system was investigated as a function of refrigerant charge and its performance was analyzed in cooling mode, heating mode, and heat recovery mode. COP in the heating or cooling mode showed little dependence on refrigerant charge at overcharge conditions, while those were strongly dependent on refrigerant charge at undercharge conditions and outdoor inlet temperature. In the heat recovery mode, the performance of the system was very sensitive to charge amount at all conditions. Optimum charge amount in the heat recovery mode was 14% lower than that in the cooling mode at the standard condition because the refrigerant only passed the indoor units. It is required to store the excessive refrigerant charge in a storage tank to optimize the system performance at operating modes.

전축열방식 빙축열 시스템의 최적제어 알고리즘 (Optimal Control Algorithms for the Full Storage Ice Cooling System)

  • 한도영;이준호
    • 설비공학논문집
    • /
    • 제14권4호
    • /
    • pp.350-357
    • /
    • 2002
  • Optimal control algorithms for the full storage ice cooling system were developed by using a dynamic simulation program. Control algorithms for the storage charging mode were developed for the chiller outlet temperature setpoint control and the chiller capacity control. Control algorithms for the storage discharging mode were developed for the proper mode selection, the storage-only mode control, and the storage-priority chiller-shared mode control. Two different cases of the expected outdoor air temperature profile and the expected cooling load profile were used to analyze the effectiveness of these algorithms. Simulation results show the energy savings and the satisfactory controls of the ice storage system. Therefore, control algorithms developed for this study may effectively be used for the improved control of the ice storage cooling system.

수소연료전지 자동차 열관리 시스템의 상호 영향도 분석을 위한 실험적 연구 (Experimental Study on the Mutual Influence of Thermal Management System for Hydrogen Fuel Cell Vehicle)

  • 이무연;원종필;조중원;이호성
    • 한국수소및신에너지학회논문집
    • /
    • 제22권6호
    • /
    • pp.852-858
    • /
    • 2011
  • This paper is aiming to estimate the mutual influence of the stack cooling performances with the operation modes of the thermal management system for the hydrogen fuel cell vehicles. The heat capacity of the thermal management system was measured by varying the operating modes such as stack cooling heat exchanger only (Mode 1), stack cooling and electric devices cooling heat exchangers (Mode 2), and stack cooling and electric devices cooling heat exchangers with an operation of the condenser (Mode 3).As the results, Performance of the thermal management system (TMS) at Mode 3 decreased up to 34.0%, compared with the result of the Mode 1. In addition, in order to optimize the performance of TMS, the entropy change of stack cooling heat exchanger using irreversibility analysis technique was analyzed with the relationship between entropy generation and entering air velocity of the thermal management system.

난방주체 운전모드에서의 동시냉난방 열펌프 성능향상에 관한 실험적 연구 (Experimental Study on the Performance Improvement of a Simultaneous Heating and Cooling Heat Pump in the Heating-main Operating Mode)

  • 강훈;정현준;주영주;김용찬;최종민
    • 설비공학논문집
    • /
    • 제20권4호
    • /
    • pp.245-251
    • /
    • 2008
  • The cooling load in winter is significant in buildings and hotels because of the usage of office equipments and the high efficiency of wall insulation. Hence, the development of a multi-heat pump that can cover heating and cooling simultaneously for each indoor unit is required. In this study, the operating characteristics and performance of a simultaneous heating and cooling heat pump in the heating-main operating mode were investigated experimentally. The system adopted a variable speed compressor with four indoor units and one outdoor unit with R-410A. In the heating-main mode, the cooling capacity was lower than the design cooling capacity due to the reduction of the flow rate in the indoor unit for the cooling, with the increase of the heating capacity. To solve these problems, the performance characteristics of the simultaneous heating and cooling heat pump in the heating-main mode were investigated by varying the flow rate to the indoor unit for the cooling and the compressor rotating speed. In addition, the adequate control methods were suggested to improve the system efficiency.

동시냉난방 열펌프의 전열회수 성능 특성에 관한 연구 (Experimental Study on the Performance of a Simultaneous Heating and Cooling Heat Pump in the Heat Recovery Mode)

  • 최종민;정현준;주영주;강훈;김용찬
    • 설비공학논문집
    • /
    • 제20권11호
    • /
    • pp.718-726
    • /
    • 2008
  • The cooling load in winter is significant in buildings and hotels because of the usage of office equipments and the high efficiency of wall insulation. Hence, the development of a multi-heat pump that can cover heating and cooling simultaneously for each indoor unit is required. In this study, the performance of a simultaneous heating and cooling heat pump was investigated in the heat recovery mode (HR mode). The system adopted a variable speed compressor using R410A with four indoor units and one outdoor unit. In the HR mode, the capacity and COP were improved as compared with those in the cooling or heating mode because the waste heat in the outdoor unit was utilized as useful heat in the indoor units. However, energy imbalance between heating and cooling capacity of each indoor unit was observed in the 2H-1C HR mode. Therefore, the performance of the system in the 2H-1C HR mode was enhanced by controlling refrigerant flow rate through the outdoor unit.

건식회전형 제습기의 성능향상에 관한 실험적 연구 (An Experimental Study on Improved Performance of Rotary Solid Dehumidifier)

  • 이기영;김효경
    • 대한설비공학회지:설비저널
    • /
    • 제16권3호
    • /
    • pp.285-294
    • /
    • 1987
  • Parametric study on the efficiency of Rotary Solid Dehumidifer are reported. Experi-ments have been performed by varying regeneration temperature, regeneration humidity, flow rate of regeneration air, angular velocity of dehumidifer rotor and regeneration angle. To improve the energy efficiency, MODE 2,3 where coding zone is constructed and MODE 4, 5 where recirculating zone is constructed, were studied through experimental method $\ldots$. These results show that economical operating ranges exist in regeneration temperature, flow rate of regeneration air, angular velocity of dehumidifier rotor and regeneration angle. MODE 2,3 where cooling zone is constructed between regeneration Bone and process zone, is far better than MODE 1 in view of energy effiency, and optimum cooling angle and flow rate of cooling air exist. But MODE 4 and MODE 5, where recirculating zone is constructed, are similar to MODE 1.

  • PDF

자동차용 엔진 냉각시스템의 이론적 해석 (Theoretical Analysis in an Automotive Engine Cooling System)

  • 윤종갑;송승훈;원성필
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.213-219
    • /
    • 2000
  • In this work, it has been predicted the thermal performance of the engine cooling system in cases of stationary mode, constant speed mode, city-drive mode, and hill-climb mode by theoretical modeling of each component and numerical analysis. The modelling components are engine, radiator, heater, thermostat, water-pump, and cooling-fan. And also it has been developed the simulation program that can be used in case of design and system configuration changes. The comparison has not been made to verify the results of this work with experimental data, but the overall tendencies were agreed well with those of actual situation in four modes.

  • PDF

3관식 시스템 히트펌프의 충전량 변화에 따른 성능 특성에 관한 연구 (The performance of a heat pump with 3-piping system at various charging conditions)

  • 송인식;최종민;주영주;정현준;강훈;김용찬
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.288-293
    • /
    • 2008
  • The cooling load in winter is significant in many commercial buildings and hotels because of the usage of office equipments and the high efficiency of wall insulation. The development of a multi-heat pump that can cover heating and cooling simultaneously for each indoor unit is required. In this study, the performance of a multi-heat pump with 3-piping system was investigated as a function of refrigerant charge and its performance was analyzed in cooling mode, heating mode, and heat recovery mode. COP in the heating or cooling mode showed little dependence on refrigerant charge at overcharge conditions, while those were strongly dependent on refrigerant charge at undercharge conditions and outdoor inlet temperature. In the heat recovery mode, the performance of the system was very sensitive to charge amount at all conditions. Optimum charge amount in the heat recovery mode was 14% lower than that in the cooling mode at the standard condition because the refrigerant only passed the indoor units. It is required to store the excessive refrigerant charge in a storage tank to optimize the system performance at operating modes.

  • PDF