A Study on the Improvement of the Water Source Energy Distribution Regulation for High Efficient Data Center Cooling System in Korea (데이터센터 냉방시스템 고효율화를 위한 국내 수열에너지 보급 제도 개선에 관한 연구)

  • Cho, Yong;Choi, Jong Min
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.17 no.3
    • /
    • pp.21-29
    • /
    • 2021
  • In this study, the current regulation of the water source energy, one of the renewable energy, was analyzed, and the improvement plan for the high efficient data center cooling system was suggested. In the improvement plan, the design and construction guidelines of the water source energy system permit to adopt the cooling and heating system with or without heat pump. In addition, it should also include the system operated in the cooling mode only all year-round. The domestic test standards to consider the water source operating conditions should be developed. Especially, it is highly recommended that the test standards to include the system with forced cooling and free cooling modes related with the enhanced data center cooling system adopting the water source energy.

A Study on Air-distribution method for the Thermal Environmental Control in the Data Center (데이터센터의 합리적인 환경제어를 위한 공기분배 시스템에 대한 연구)

  • Cho, Jin-Kyun;Cha, Ji-Hyoung;Hong, Min-Ho;Yeon, Chang-Kun
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.487-492
    • /
    • 2008
  • The cooling of data centers has emerged as a significant challenge as the density of IT server increases. Server installations, along with the shrinking physical size of servers and storage systems, has resulted in high power density and high heat density. The introduction of high density enclosures into a data center creates the potential for "hot spots" within the room that the cooling system may not be able to address, since traditional designs assume relatively uniform cooling patterns within a data center. The cooling system for data center consists of a CRAC or CRAH unit and the associated air distribution system. It is the configuration of the distribution system that primarily distinguishes the different types of data center cooling systems, this is the main subject of this paper.

  • PDF

Evaluation of Diecasting Mold Cooling Ability by Decompression Cooling System (감압냉각장치를 이용한 다이캐스팅 금형의 냉각성능평가)

  • Kim, Eok-Soo;Park, Joo-Yul;Kim, Yong-Hyun;Son, Gi-Man;Lee, Kwang-Hak
    • Journal of Korea Foundry Society
    • /
    • v.29 no.5
    • /
    • pp.238-243
    • /
    • 2009
  • This study has been carried out to investigate the cooling ability improvement of diecasting mold by decompression cooling system. The decompression cooling system was applied to the new/used oil pump cover molds. The temperature of the surface mold applied the decompression cooling system fell to 15 degrees, especially in case of the used mold. The defect ratio of the oil pump cover manufactured by decompression cooling system has decreased from 2.8 percent to 0.2 percent. According to the results of the cooling ability improvement of diecasting mold by decompression cooling system, the decompression degree and supply pressure were set up the control item to apply the decompression cooling system to the diecasting mold in the industry field.

Analysis and Improvement of Cooling System for Energy Saving in Data Center Building (데이터센터의 냉방에너지 절감을 위한 냉각시스템 분석 및 개선 방안)

  • Jung, Yong-Ho
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.314-319
    • /
    • 2011
  • Energy Cost has been rapidly increased with the internal heat gain of data center to keep the temperature condition. But the cooling units for server systems are fully operated to satisfy the indoor temperature condition, it results in the excessive energy consumption. In this study, various cooling systems were studied for data center and cold aisle containment system was proved to be the best solution for server cooling system. Because it protects the cooling zone from the hot aisle space. Effective cooling and prohibition of recirculation air from hot aisle was possible by the cold aisle containment system.

  • PDF

A Study on Evalution of Corrosion Properties in cooling tube of water cooling transformers (수냉식변압기 냉각튜브의 부식특성 평가에 관한 연구)

  • Jeong, Nyeon-Ho;Min, Byung-Yeon;Park, Hyun-Joo
    • Corrosion Science and Technology
    • /
    • v.9 no.5
    • /
    • pp.216-222
    • /
    • 2010
  • Most of the thirteen substations in operation in the metropolitan area were installed around the year 2000, and since water cooling methods are used to directly withdraw heat from transformer oils, a stable supply of electric power is required through optimal maintenance of facilities. The water cooling tower installed outdoors, which uses the water supply as sprinkler water, experiences the most problems. Since more than 90% of the cooling water is reused, the dissolved composition in the water becomes concentrated due to long operating hours, and impurities dissolve in the water due to air flowing in from the outside, forming hard scales on the outer surface of the cooling tube, and in extreme cases, reacting with the tube material composition, leading to corrosion. As a result, not only is cooling efficiency lowered, but in extreme cases the cooling tube must be replaced. In this study, the characteristics and composition of the scales formed on the cooling tube were analyzed and corrosion characteristics of material types were identified in order to find an efficient maintenance method for cooling tubes. In addition, the degree of dissolution of various chemicals were investigated during the removal of scales that have been formed.

Analysis on the Energy Saving Effect of Free Cooling System in Data Center (데이터 센터의 외기냉수냉방 시스템에 대한 에너지 절감효과 분석)

  • Yoon, Jung-In;Son, Chang-Hyo;Heo, Jeong-Ho;Kim, Young-Min
    • Journal of Power System Engineering
    • /
    • v.18 no.3
    • /
    • pp.73-78
    • /
    • 2014
  • Recently, Free cooling system usage has increased at many buildings in intermediate and winter season. Free cooling system is used to reduce the energy consumption of refrigeration in that season. Free cooling system is refrigeration system using cooled water. In general, this system is applied with the building having refrigeration load at all time such as a data center. In this study, energy consumption of a data center taking free cooling system in Ulsan was evaluated by the software HYSYS. the main result is as in the following : free cooling system is effective from January to April and from November to December. In case of Ulsna in 2013, using free coolng system is able to spend refrigeration energy of about 15% less than existing system. According to this result, it is appropriated that free cooling system is used in building having refrigeration load at all time such as data center.

Effect of Carbon Equivalent and Cooling Rate on Microstructure in A516 Steels for Pressure Vessel (압력용기용 A516 강의 미세조직에 미치는 탄소 당량과 냉각 속도의 영향)

  • Lee, Hyun Wook;Kang, Ui Gu;Kim, Min Soo;Shin, Sang Yong
    • Korean Journal of Materials Research
    • /
    • v.29 no.8
    • /
    • pp.511-518
    • /
    • 2019
  • In this study, the effect of carbon equivalent and cooling rate on microstructure and hardness of A516 steels for pressure vessel is investigated. Six kinds of specimens are fabricated by varying carbon equivalent and cooling rate, and their microstructures and hardness levels are analyzed. Specimens with low carbon equivalent consist of ferrite and pearlite. As the cooling rate increases, the size of pearlite decreases slightly. The specimens with high carbon equivalent and rapid cooling rates of 10 and $20^{\circ}C/s$ consist of not only ferrite and pearlite but also bainite structure, such as granular bainite, acicular ferrite, and bainite ferrite. As the cooling rate increases, the volume fractions of bainite structure increase and the effective grain size decreases. The effective grain sizes of granular bainite, acicular ferrite, and bainitic ferrite are ~20, ~5, and ${\sim}10{{\mu}m$, respectively. In the specimens with bainite structure, the volume fractions of acicular ferrite and bainitic ferrite, with small effective grains, increase as cooling rate increases, and so the hardness increases significantly.

Flow and Heat Transfer Analysis of Cooling Water in a Rotating Magnetron Cathode (회전형 마그네트론 음극의 냉각수 유동 및 열전달 해석)

  • Joo, Junghoon
    • Journal of the Korean institute of surface engineering
    • /
    • v.52 no.3
    • /
    • pp.171-179
    • /
    • 2019
  • We have developed a numerical model to analyze flow dynamics and heat transfer characteristics of the cooling water in a circular rotating magnetron cathode by a moving boundary grid method realized in a commercial multiphysics package, CFD-ACE+. The numerical model is composed of a target, dual mass rotating cathode and cooling water connections. When the inlet and outlet of the cooling water are offset by the same distance from the rotation axis, the temperature at the center is higher by $50^{\circ}C$ at maximum. At 5 mm away from the target surface, the temperature profile showed typical center high characteristic. At heat input of 30 kW, the maximum temperature change of the cooling water hits $6^{\circ}C$ within 0.5 sec under 60 rpm. With a cooling water configuration of center in/edge out, the temperature of the center region of the target gets lowered. Within 100 seconds of plasma operation time, the cooling water temperature keeps getting higher.

Energy Performance of Air-side Economizer System for Data Center Considering Supply Temperature and Design Airflow Rate of CRAH(Computer Room Air Handler) (외기냉방시스템이 적용된 데이터센터 CRAH의 급기온도와 설계 풍량에 따른 에너지성능 분석)

  • Kim, Ji-Hye;Aum, Tae-Yun;Jeong, Cha-Su
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.35 no.11
    • /
    • pp.181-188
    • /
    • 2019
  • The purpose of this study is to evaluate the cooling energy saving effects of CRAH supply air temperature(SAT) and design flow rate changes when applying air-side economizer in the data center. MLC(Mechanical Load Component), which is cooling performance indicator of data center, was used to assess the effectiveness of cooling energy savings. It was computed with energy simulation (DesignBuilder) to evaluate the cooling energy performance of 8 different alternatives in a data center. The MLC was 0.31~0.32 regardless of CRAH supply temperature without air-side economizer, and 0.15 to 0.19 value with air-side economizer. That is, cooling energy can be reduced by approximately 40~55% when applying economizer. As the CRAH SAT and design flow rate changed, the MLC values were 0.16 to 0.18 and 0.15 to 0.19, respectively.

Desktop PC CPU Cooling System Design and Analysis

  • Choi, Jee-Hoon;Yoo, Jung-Hyun;Seo, Min-Whan;Kang, Shin-Jae;Kim, Chul-Ju
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.601-604
    • /
    • 2008
  • Desktop PC CPUs have been significantly required to be the necessity of thermal management while they have satisfied the extensive data and graphic processing requirements. So the cooling systems assembled with heat pipes embedded in a metal cooling plate, and fins are widely used in the desktop PC markets. Due to a number of demands such as the confined space of desktop PCs, higher heat density of CPUs, and acoustic noise, however, there is the main drive to improve continuously cooling systems. This paper presents the flow and thermal behavior of the cooling system by using the computational fluid dynamics(CFD) code.