• 제목/요약/키워드: Cooling & Heating Capacity

검색결과 182건 처리시간 0.024초

가정용 지열원 열펌프 시스템의 냉난방 성능 특성 연구 (An Experimental Study on the Cooling and Heating Performance of a Residential Ground Source Heat Pump System)

  • 공형진;강성재;윤경식;임효재
    • 설비공학논문집
    • /
    • 제25권3호
    • /
    • pp.156-163
    • /
    • 2013
  • Ground Source Heat Pump (GSHP) systems utilize geothermal energy as a thermal source or sink, for heating, cooling and domestic hot water. It is well known that GSHP is environmentally friendly, and saves energy dramatically. For this reason, many investigative researches have been conducted on commercial and governmental buildings. However, studies on residential GSHP are few, because of the small capacity and cost. In this study, we experimented with the characteristic performance of heating, cooling and seasonal performance factor for a residential GSHP system, which consisted of two 180 m deep u-tube ground heat exchangers, a heat pump and measurement instruments. The installed capacity of the heat pump was 5RT, and the conditioning area was $62.23m^2$. From the experimental results, the cooling COP of the heat pump was 4.13, and the system COP was 3.51, while the CSPF was 3.32. On the other hand, the heating COP of the heat pump was 3.87, and the system COP was 3.39, while the HSPF was 3.39. Also, in-situ cooling COP and capacity were 93.7% and 96.4% compared with the EWT certification data, respectively, and that of heating were 98.3% and 95.7%, respectively.

공공도서관에 지열시스템 적용시 경제성에 관한 연구 (A Study on the Economic Analysis of Cooling-Heating System Using Ground Source Heat in a public library)

  • 최창호
    • 한국태양에너지학회 논문집
    • /
    • 제32권1호
    • /
    • pp.56-66
    • /
    • 2012
  • This study evaluated the economic benefits by comparing Cooling-Heating System with the existing system in the public library. The building's annual energy consumption was measured by adding the figures of the absorber chillers, the air conditioners and heaters in the building. The total amount of annual energy consumption was 143.51RT in air-conditioning and 83.66RT in heating. So, We made the capacity of geothermal heat pumps three 50RTs in order to check up this system. In order to estimate each construction and equipment cost and to evaluate economical efficiency, LCC(Life Cycle Cost) method was used and the service life of the building was sixty years. The result of analysis was that the geothermal cooling-heating system was more efficient than the existing system in public library.

가변속 열펌프의 냉매 유량제어에 의한 난방성능 변화에 관한 실험적 연구 (An Experimental Investigation on the Variation of Heating Performance Due to the Refrigerant Flow Control in a Variable-Speed Heat Pump)

  • 김봉훈
    • 설비공학논문집
    • /
    • 제13권8호
    • /
    • pp.746-756
    • /
    • 2001
  • An experimental study was conducted to investigated the effect of refrigerant flow control on the performance of a variable-speed heat pump operating in both cooling and heating mode. For this purpose, cooling and heating capacity, EER and refrigerant mass flow rate corresponding to an electronic valve as well as a capillary tube were measured as functions of compressor speed, length of capillary tube (or valve opening of the electronic valve), refrigerant charge, and outdoor temperature. From the comparison of experimental results, it was found that the performance variation due to the electronic valve opening became significant as the operating conditions(outdoor temperature and compressor speed) deviated from the standard condition at which heating capacity and EER were rated for the indicated capillary tube.

  • PDF

인버터형 멀티 히트펌프의 냉난방 운전특성에 대한 실험연구 (Experimental Study on Cooling and Heating Operation Characteristics of Inverter type Multi-Heat Pump)

  • 박병권;서동남;엄유식;권영철;고국원
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.618-622
    • /
    • 2007
  • In the present study, the cooling and heating operation characteristics of a multi-heat pump have been experimentally investigated for the number of the indoor units(A, B, C) and the operating conditions. The heat pump was controlled by an inverter scroll compressor. The performance of the heat pump was measured by the multi-calorimeter of an air enthalpy method. Cooling and heating capacities and COPs were obtained at the cooling and heating temperature conditions and the setting temperatures of an indoor unit. With increasing the operation frequency of the compressor, the cooling and heating capacities of the heat pump increased linearly. The operation frequency region of the compressor was different as the combination of the indoor unit and the cooling/ heating condition.

  • PDF

증기분사를 적용한 고온수용 지열 히트펌프의 성능특성 (Performance of the Geothermal Heat Pump using Vapor Injection for Hot Water)

  • 박용정;박병덕
    • 한국수소및신에너지학회논문집
    • /
    • 제25권3호
    • /
    • pp.297-304
    • /
    • 2014
  • The purpose of this study is to evaluate the experimental performance characteristics of a water-to-water geothermal heat pump featuring a vapor refrigerant injection for the production of hot water. The performance of geothermal heat pump with a vapor injection was evaluated by comparing with that of a conventional geothermal heat pump without a vapor injection. For heating operation, the geothermal heat pump with a vapor injection is superior in COP and heating capacity. The vapor injection was more effective for supplying hot water while overloading. The vapor injection was effective for the improvement of the cooling capacity. However, the vapor injection was not effective for the increasing of COP according to the increased input of a compressor. The advantage of vapor injection in water-to-water geothermal heat pump become disappeared while cooling operation with lower part loading.

액체 제습식 냉방 사이클의 최적화 (Optimization of Liquid Desiccant Cooling Cycle)

  • 김선창;김영률;이상재;전동순;최장현;권혁민;이창준
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.673-678
    • /
    • 2009
  • This paper presents the optimization process of liquid desiccant cooling cycle using LiCl aqueous solution as a working fluid. Operating conditions and design factors for heat exchangers were optimized by response surface method. As a result, we obtained the 7.297 kW of cooling capacity and 0.788 of COP at optimized condition. Effect of $dT_{hw}$ on system performances was also examined. As $dT_{hw}$ increases, the cooling capacity increases and COP decreases.

  • PDF

액체 제습식 냉방 시스템의 최적 설계 (Optimization Design of Liquid Desiccant Cooling System)

  • 전동순;이상재;김선창;김영률;이창준
    • 설비공학논문집
    • /
    • 제22권7호
    • /
    • pp.419-428
    • /
    • 2010
  • This paper presents the optimization process of liquid desiccant cooling system using LiCl aqueous solution as a working fluid. Operating conditions(mass flow rate, conditioner outlet concentration, difference concentration) and design factors for heat exchangers(difference temperature of the district heating water, leaving temperature difference of the conditioner, leaving temperature difference of the regenerator, air temperature difference of the conditioner, air temperature difference of the regenerator) were optimized by response surface method. As a result, we obtained the 7.297 kW of cooling capacity and 0.788 of COP at optimized condition. Effect of difference temperature of hot water on system performances was also examined. As difference temperature of the district heating water increases, the cooling capacity increases and COP decreases.

냉.온열 동시 제조시스템의 성능분석(I)-Simulation (Performance Analysis of Simultaneous Heating & Cooling Water Making System(I)-Simulation)

  • 박성룡;박준택;안영훈
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.266-271
    • /
    • 2001
  • In this study, the performance of the simultaneous heating & cooling water making system using R134a was investigated by simulation. The most important effect upon heating COP was intermediate pressure depending on input water temperature. With the input water temperature of $10^{\circ}C\;and\;20^{\circ}C$, optimum intermediate pressure were 923 and 1040kPa, respectively. At that optimum intermediate pressure, the maximum heating COP of the system operated between $0^{\circ}C$ evaporating temperature and $70^{\circ}C$ condensing temperature were 4.15 and 3.83. With installation of the subcoolers in high or low pressure section, the system COP was increased by reducing the refrigerant mass flow rate. Under the optimum pressure and $10^{\circ}C$ input water temperature, it was found that heating COP was maximized when the low-subcooler and high-subcooler capacity rate were taken by 14% and 13%, respectively.

  • PDF

건물 에너지 시뮬레이션을 이용한 반밀폐형 온실의 동적 에너지 부하 예측 및 수소연료전지 3중 열병합 시스템 적정 용량 산정 (Optimal Capacity Determination of Hydrogen Fuel Cell Technology Based Trigeneration System And Prediction of Semi-closed Greenhouse Dynamic Energy Loads Using Building Energy Simulation)

  • 이승헌;김락우;김찬민;석희웅;윤성욱
    • 생물환경조절학회지
    • /
    • 제32권3호
    • /
    • pp.181-189
    • /
    • 2023
  • 수소는 다양한 신재생에너지 중 환경친화적인 에너지로 각광받고 있지만 농업에 적용된 사례는 드물다. 본 연구는 수소연료전지 삼중 열병합 시스템을 온실에 적용하여 에너지를 절약하고 온실가스를 줄이고자 한다. 이 시스템은 배출된 열을 회수하면서 수소로부터 난방, 냉각 및 전기를 생산할 수 있다. 수소 연료 전지 삼중 열 병합 시스템을 온실에 적용하기 위해서는 온실의 냉난방 부하 분석이 필요하다. 이를 위해서는 온실의 형태, 냉난방 시스템, 작물 등을 고려해야 한다. 따라서 본 연구에서는 건물 에너지 시뮬레이션(BES)을 활용하여 냉난방 부하를 추정하고자 한다. 전주지역의 토마토를 재배하는 반밀폐형 온실을 대상으로 2012년부터 2021년까지의 기상데이터를 수집하여 분석했다. 온실 설계도를 참고하여 피복재와 골조를 모델화하여 작물 에너지와 토양 에너지 교환을 실시했다. 건물 에너지 시뮬레이션의 유효성을 검증하기 위해 작물의 유무에 의한 분석, 정적 에너지 및 동적 에너지 분석을 실시했다. 또한 월별 최대 냉난방 부하 분석에 의해 평균 최대 난방 용량 449,578kJ·h-1, 냉방 용량 431,187kJ·h-1이 산정되었다.

히트 펌프용 비대칭 스크롤 압축기의 가스 인젝션 포트 설계 (Design of Gas-Injection Port of an Asymmetric Scroll Compressor for Heat Pump Systems)

  • 김용희;김현진
    • 설비공학논문집
    • /
    • 제27권6호
    • /
    • pp.300-306
    • /
    • 2015
  • For an asymmetric scroll compressor for heat pump application, a numerical simulation was carried out to investigate the effects of injection port design on the compressor's performance under gas injection. To validate the simulation, the numerical results were compared with experimental results obtained from a scroll compressor with a base injection port design. There was good agreement between simulation and experimental results, with around a 1% difference in the injection mass flow rate when the injection pressure was below $12kgf/cm^2A$ for the heating mode. Various injection port angular positions were numerically tested to yield better injection performance. The largest improvement in heating capacity was obtained at angles of $240^{\circ}$ and $200^{\circ}$ inward from the scroll wrap end angle for low-temperature and standard heating conditions, respectively, while the maximum COP improvement was at $365^{\circ}$ and $280^{\circ}$, respectively. A considerable improvement in cooling capacity was also found at the injection port angle of $240^{\circ}$.