• Title/Summary/Keyword: Cooled Condition

Search Result 280, Processing Time 0.027 seconds

An analytical study on the heat transfer of the laminar filmwise condensation on a vertical surface (수직평판에서 층류막상 응축열전달에 관한 해석적 고찰)

  • 김형섭
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.2 no.1
    • /
    • pp.21-31
    • /
    • 1980
  • Two phase boundary layer equations of laminar filmwise condensation are solved by an approximate integral method under the following condition; saturated vapour flows vertically downward over a cooled surface of uniform temperature, the condensate film is so thin that the inertia and convection terms are neglected. The following conclusions are drawn under the above assumptions. 1. free convection In case of the linear temperature profile in a liquid film, numerical results for the average coefficients of heat transfer may be expressed as N $u_{m}$=4/3,(G $r_{l}$ /4.H)$^{1}$4/ and in case of the quadratic profile, numerical results may be expressed as N $u_{m}$=2/1.682,(G $r_{l}$ /H)$^{1}$4/. 2. Forced convection When the temperature profile is assumed to be linear in a liquid film, numerical results fir the average heat transfer coefficients may be expressed as N $u_{m}$=(A, R $e_{l}$ /H)$^{1}$2/. This expression is compared with the experimental results hitherto reported; For theoretical Nusselt number (N $u_{m}$)$_{th}$<2*10$^{4}$, the experimental Nusselt number (N $u_{m}$)$_{exp}$ is on the average larger than theoretical Nusselt number (N $u_{m}$)$_{th}$ by 30%. For (N $u_{m}$)$_{th}$>2*10$^{4}$, experimental Nusselt number (N $u_{m}$)$_{exp}$ is about 1.6 times as large as theoretical Nusselt number (N $u_{m}$)$_{th}$. These large deviation may be caused by the presence of turbulence in the liquid film. In case of the quadratic temperature profile in a liquid film, numerical results for the average coefficients of heat transfer may be expressed as N $u_{m}$'=(2,A,Re/H)$^{1}$2/. This formular shows that theoretical Nusselt number (N $u_{m}$)$_{th}$ is larger than experimental Nusselt number (N $u_{m}$)$_{exp}$ by 60%. It is speculated that when the temperature difference between cooled surface and saturated vapour is small, temperature profile in a liquid film is quadratic.quadratic.. quadratic.quadratic..atic..

  • PDF

A study on the barrier effect with respect to the condition of solid insulation materials in GN2

  • Lee, Hongseok;Mo, Young Kyu;Lee, Onyou;Kim, Junil;Bang, Seungmin;Kang, Jong O;Nam, Seokho;Kang, Hyoungku
    • Progress in Superconductivity and Cryogenics
    • /
    • v.17 no.1
    • /
    • pp.44-47
    • /
    • 2015
  • High voltage superconducting apparatuses have been developed presently around the world under AC and DC sources. In order to improve electrical reliability of superconducting apparatuses with AC and DC networks, a study on the DC as well as the AC electrical breakdown characteristics of cryogenic insulations should be conducted for developing a high voltage superconducting apparatus. Recently, a sub-cooled liquid nitrogen cooling system is known to be promising method for developing a high voltage superconducting apparatus. A sub-cooled liquid nitrogen cooling system uses gaseous nitrogen to control the pressure and enhance the dielectric characteristics. However, the dielectric characteristics of gaseous nitrogen are not enough to satisfy the grade of insulation for a high voltage superconducting apparatus. In this case, the application of solid insulating barriers is regarded as an effective method to reinforce the dielectric characteristics of a high voltage superconducting apparatus. In this paper, it is dealt with a barrier effect on the DC and AC dielectric characteristics of gaseous nitrogen with respect to the position and number of solid insulating barriers. As results, the DC and AC electrical breakdown characteristics by various barrier effects is verified.

Analysis of stress and distortion that develop during accelerated cooling of plate (가속냉각시 강판에 발생하는 응력 및 변형에 대한 연구)

  • 김호영;김창영;주웅용;장래웅
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.12 no.5
    • /
    • pp.952-958
    • /
    • 1988
  • To analyze the nonflatness and residual stress in accelerated cooled plate, a numerical analysis model has been developed. Two factors, i.e. temperature and phase transformation, are considered in calculating the stress distribution that develops during cooling. The plastic strain and plate-buckling, which are often shown in accelerated cooled plate, were determined from this stress. Mean temperature in through thickness direction and temperature difference in width direction are considered in the model to simplify the calculation. The temperature and stress distribution changes caused by phase transformation are involved in terms of the effective specific heat and the effective thermal expansion coefficient. With the model, accelerated cooling of 10mm(t) $^{*}$3000mm(w) plate was simulated. The condition of accelerated cooling was .deg. C/sec from just after hot rolling to 500.deg. C. The initial temperature-difference ratio, .DELTA.Tr, in width direction is an important factor in evaluating the stress distribution. When .DELTA.Tr is 0.08, buckling occurs during cooling and 7kgf/m $m^{2}$ of residual stress develops at the edge of plate. To secure the flatness, .DELTA.Tr should be less than 0.07. Small scaled cooling test was conducted to verify the exactness of the model and the results proved the usefulness of this numerical analysis model.l.

Thermo-structural Analysis for Radiation-Cooled Nozzle Extension of Thrust Chamber (복사냉각방식 연소기 노즐확장부 열/구조해석)

  • Ryu, Chul-Sung;Lee, Keum-Oh;Choi, Hwan-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.04a
    • /
    • pp.291-295
    • /
    • 2011
  • Thermo-structural analysis was performed for a radiation-cooled nozzle extension of thrust chamber. A Niobium alloy that is known to be a high-performance refractory alloy was used. Since area ratio of the nozzle extension is larger than that of nozzle divergence part, its size also becomes larger. For this reason, it is important to minimize the thickness of nozzle extension to reduce its weight. For the purpose of weight minimization, the thickness of nozzle extension was varied from 1.0 mm to 0.4 mm and structural stability was evaluated for each case. Analysis results showed that nozzle extension with thickness of 0.4 mm is structurally stable for the operation condition. The effect of combustion-included vibration will be additionally considered in the future.

  • PDF

Preliminary design and assessment of a heat pipe residual heat removal system for the reactor driven subcritical facility

  • Zhang, Wenwen;Sun, Kaichao;Wang, Chenglong;Zhang, Dalin;Tian, Wenxi;Qiu, Suizheng;Su, G.H.
    • Nuclear Engineering and Technology
    • /
    • v.53 no.12
    • /
    • pp.3879-3891
    • /
    • 2021
  • A heat pipe residual heat removal system is proposed to be incorporated into the reactor driven subcritical (RDS) facility, which has been proposed by MIT Nuclear Reactor Laboratory for testing and demonstrating the Fluoride-salt-cooled High-temperature Reactor (FHR). It aims to reduce the risk of the system operation after the shutdown of the facility. One of the main components of the system is an air-cooled heat pipe heat exchanger. The alkali-metal high-temperature heat pipe was designed to meet the operation temperature and residual heat removal requirement of the facility. The heat pipe model developed in the previous work was adopted to simulate the designed heat pipe and assess the heat transport capability. 3D numerical simulation of the subcritical facility active zone was performed by the commercial CFD software STAR CCM + to investigate the operation characteristics of this proposed system. The thermal resistance network of the heat pipe was built and incorporated into the CFD model. The nominal condition, partial loss of air flow accident and partial heat pipe failure accident were simulated and analyzed. The results show that the residual heat removal system can provide sufficient cooling of the subcritical facility with a remarkable safety margin. The heat pipe can work under the recommended operation temperature range and the heat flux is below all thermal limits. The facility peak temperature is also lower than the safety limits.

Experimental Study on Dark Current Noise to Reduce Background Voltage Level of Optical Emission Spectroscopy (광분광기의 노이즈 감소를 위한 암전류에 대한 실험적 고찰)

  • Youngjun Yuk;Keonwoo Lee;Eunjong Choi;Hyoyoung Kim;Kihyun Kim
    • Journal of the Semiconductor & Display Technology
    • /
    • v.22 no.4
    • /
    • pp.93-98
    • /
    • 2023
  • As semiconductor devices become highly integrated and process difficulty increases, the need for highly sensitive sensors that can detect micro leaks is increasing. However, the noise contained in the CCD sensor itself acts as an obstacle to detecting fine leaks. In this study, integration time was changed for each condition, the sensor was cooled to 0℃, and the dark voltage level was measured to confirm through experiment the characteristics of the temporal noise included in the CCD sensor, a component of OES (Optical Emission Spectroscopy). When integration time was reduced from 30msec to 10msec, the dark voltage level decreased by about 20.5 % from an average of 151.5mV to 120.5mV. In the case of cooling device, Peltier elements were selected because of their simple structure and small size. During temperature cooling, the target temperature was controlled to within ±0.5℃ through PID control. When cooled from 20℃ to 0℃ using this cooling device, it was confirmed that the dark voltage level decreased by about 7% from an average of 147.0mV to 137.0mV.

  • PDF

The Effect of Microstructure and Mechanical Property with Cooling Rapid in Boron-Treated Low Carbon Low Alloy Steel (저탄소.저합금 보론 첨가강의 냉각속도에 따른 미세조직과 기계적 성질의 영향)

  • Son, J.Y.;Lee, G.D.;Kim, S.G.;Kim, Y.S.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2008.10a
    • /
    • pp.207-210
    • /
    • 2008
  • The effects of boron additions in steels have long been recognized as very important, mainly with respect to hardnability of heat treatable steels. we investigated the effect of the microstructure and mechanical properties with cooling condition after heat treatment of the boron-treated(${\fallingdotseq}8{\sim}18ppm$) low carbon(${\fallingdotseq}0.2%C$) low alloy steel. The specimens were austenitised for 10 min at $910^{\circ}C$, cooled for the various periods of time from 10 sec to 30 sec or with water after forming for 15 sec. After cooling, mechanical properties were measured by tensile test and hardness test. For analysis of microstructure, Optical were carried out.

  • PDF

Effect of Carburetor throttle angle on the characteristics of 2-stroke 26cc small engine (카뷰레터 스로틀 변화가 26cc 급 2 행정 엔진 특성에 미치는 영향)

  • Choy, Y.H.;Cho, H.M.;Cho, S.N.;Kim, B.G.;Yoon, S.J.;Han, J.G.
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.3341-3346
    • /
    • 2007
  • This paper presents effects of carburetor throttle angle on the performance characteristics of a small sparkignited, gasoline engine. The engine used in the test is a single cylinder, two-stroke, air-cooled 26cc SI engine for brush-cutter. We measured the rpm, torque, power, and fuel consumption according to the six different throttle angle conditions of the rotary-type carburetor and to the engine dynamometer loads. We had concluded that maximum power happened at 5000${\sim}$6000rpm and at the same condition was the minimum specific fuel consumption.

  • PDF

Heat Flux Evaluation of KSR-III Sub-scale Chamber (KSR-III 축소형 연소기의 열유속 평가)

  • 조원국;문일윤;김종규
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.8 no.1
    • /
    • pp.81-84
    • /
    • 2004
  • A water-cooled calorimeter chamber with 8 cooling channels based on KSR-III sub-scale chamber has been designed and manufactured. One dimensional empirical correlation has been used at the design stage and full three-dimensional CFD analysis has been conducted to confirm the cooling condition for hot fire test is safe. Predicted heat flux is accurate around the nozzle throat when the thermal resistance of carbon deposit is considered. However relatively large difference is observed in chamber part.

Optimizing the Injection Molding Process for Cooling Filter Using Computer Simulation and Taguchi Methods (컴퓨터 시뮬레이션과 다구치 방법을 이용한 냉각 필터 사출성형 공정의 최적화)

  • Lee, Seung-Hoon;Min, Byeong-Hyeon;Kim, Byeong-Gon
    • IE interfaces
    • /
    • v.15 no.3
    • /
    • pp.263-269
    • /
    • 2002
  • The injection molding process is a one of the most efficient techniques for manufacturing plastic parts of complex shape at low cost. In injection molding, molten plastic material is injected into the mold and cooled. Selection of molding conditions greatly affects the quality of molded parts. In this case study, we attempted to optimize the injection molding condition for a cooling filter using Taguchi experimental design methodology. The injection molding experiments were carried out using the Moldflow simulation software.