• 제목/요약/키워드: Cooled Condition

검색결과 277건 처리시간 0.029초

전도냉각형 고온초전도 에너지저장장치의 전기적 특성 (A Study on the Electrical Properties of the Conduction-cooled HTS SMES System)

  • 최재형;곽동순;천현권;김해종;김상현
    • 한국전기전자재료학회논문지
    • /
    • 제20권2호
    • /
    • pp.135-141
    • /
    • 2007
  • The conduction-cooled HTS SMES is operated in cryogenic and high vacuum condition. Thus, Insulation design at cryogenic temperature and high vacuum is a key and an important element that should be established to accomplish miniaturization that is a big advantage of HTS SMES. However, the behaviors of insulators for cryogenic conditions in vacuum are virtually unknown. Therefore, we need active research and development of insulation concerning application of the conduction-cooled HTS SMES. Therefore, in this study, we experimented about insulation characteristic high vacuum and cryogenic similar to driving condition of SMES system. Also, investigated about insulation characteristic of suitable some materials to insulator for conduction-cooled HTS SMES. As this results, we possessed basis data for insulation materials selection and insulation design for development of 600 kJ class conduction-cooled HTS SMES.

전도냉각 HTS SMES 절연설계를 위한 전기적 특성연구 (A Study on the Electrical Properties for the Insulation Design of a Conduction-Cooled HTS SMES)

  • 최재형;곽동순;천현권;백승명;김해종;성기철;김상현
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 하계학술대회 논문집 Vol.7
    • /
    • pp.226-227
    • /
    • 2006
  • The conduction-cooled HTS SMES is operated in cryogenic and high vacuum condition. Thus, Insulation design at cryogenic temperature and high vacuum is a key and an important element that should be established to accomplish miniaturization that is a big advantage of HTS SMES. Therefore, we need active research and development of insulation concerning application of the conduction-cooled HTS SMES. Therefore, in this study, we experimented about insulation characteristic high vacuum and cryogenic similar to driving condition of SMES system. Also, investigated about insulation characteristic of suitable some materials to insulator for conduction-cooled HTS SMES. As this results, we possessed basis data for insulation materials selection and insulation design for development of 600 kJ class conduction-cooled HTS SMES.

  • PDF

전도냉각형 고온초전도 SMES의 냉동기와 마그네트 간의 절연 특성 (Insulating Properties between Cryocooler and Magnet for the Conduction-Cooled HTS SMES System)

  • 최재형;곽동순;천현권;김해종;성기철;김상현
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제8권3호
    • /
    • pp.45-48
    • /
    • 2006
  • The conduction-cooled HTS SMES is operated in cryogenic and high vacuum condition. Thus. Insulation design at cryogenic temperature and high vacuum is a key and an important element that should be established to accomplish compact design is a big advantage of HTS SMES. However, the behaviors of insulators for cryogenic conditions in vacuum are virtually unknown. Therefore, active research and development of insulation concerning application of the conduction cooled HTS SMES was needed. In this study, the insulation characteristics at experimented high vacuum and cryogenic similar to running condition of SMES system. Also, investigated about insulation characteristics of suitable some materials to insulator for conduction-cooled HTS SMES. As these results. the basis data was obtained for insulation materials selection and insulation design for development of 600kJ class conduction-cooled HTS SMES.

고온초전도 응용기기용 과냉질소 냉각시스템의 냉각특성 (Characteristics of Sub-cooled Nitrogen Cryogenic System for Applied High-Tc Superconducting Devices)

  • 강형구;김형진;배덕권;안민철;윤용수;장호명;고태국
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제6권1호
    • /
    • pp.38-42
    • /
    • 2004
  • The cryogenic system for 6.6 kV/200 A inductive superconducting fault current limiter (SFCL) was developed at Yonsei university in 2003. The sub-cooled nitrogen cryogenic system could be applied to not only SFCL but also many other applied high-Tc superconducting (HTS) devices like superconducting motor, superconducting generator and superconducting magnetic energy storage (SMES). Generally, the cooling capacity of GM-cryocooler depends on the load temperature. Therefore it is necessary to perform the cooling capacity test at no load condition to calculate the exact cooling power and heat load of cryogenic system. In this research, the cooling capacity test of GM-cryocooler was executed and the heat load of developed cryogenic system was calculated. The long run operation test results of sub-cooled nitrogen cryogenic system were successful in pressure and temperature condition. Moreover, the design and fabrication method of cryogenic system were introduced and the test results were described.

빙축열 에어컨의 동적 사이클 해석 (Dynamic Analysis of Cool Thermal Storage Air Conditioning System)

  • 고재윤;서태범
    • 한국태양에너지학회 논문집
    • /
    • 제28권1호
    • /
    • pp.65-74
    • /
    • 2008
  • In this study, dynamic characteristics analysis of AC system is investigated using a cool thermal storage system. A analysing program for cool thermal storage AC system is developed. The performances are studied by several variables and dynamic characteristics. Comparing the result at conventional operation condition with that at the condition using ice storage system, this study showed the effects of the sub cooled degree, superheated degree, efficiency of compressor and evaporating temperature. At the condition using thermal storage system, the thermal storage process was operated during midnight being not needed the cooling of the AC unit through the continuous running of the condenser. The refrigerant was sub-cooled using stored energy after being discharged from the air source condenser during the daytime. The COP was increased owing to the sub-cooling of refrigerant during daytime, thus the power consumption was effectively decreased.

말 냉장 정액의 정장 비율과 호기 또는 혐기 조건이 운동성에 미치는 효과 (Effect of the concentrations of seminal plasma and aerobic or anaerobic condition on the motility of cooled equine semen)

  • 박용수;양재혁;조영재;강옥득;조길재
    • 한국수정란이식학회지
    • /
    • 제33권1호
    • /
    • pp.23-30
    • /
    • 2018
  • The purpose of this study was to investigate the effects of the concentration of seminal plasma in aerobic and anaerobic conditions on the total motility(TM) and the progressive motility(PM) of spermatozoa in long term preservation of cooled equine semen. We also examine the pregnancy rates after artificial insemination using fresh, cooled or frozen semen, and different durations of cooled-preserved equine semen. In the aerobic state of cooled-preserved semen, As the increase of preserved duration to 24h, 48h, 72h, and 96h, TM tended to decrease in each of different concentrations of formalin-containing experimental group, TM tended to decrease regardless of the concentrations of SP. In different concentrations of SP, TM of without seminal plasma(SP W/O) group tended to be higher than that of SP 20%, SP 33% and SP 50%, especially TM of SP W/O group was significantly higher than other groups at 96 h (p<0.05). PM was higher in the groups of SP W/O and SP 20% than in the groups of SP 33% and SP 50% from 24 h to 72 h in cooled-preservation, especially PM of SP W/O group was significantly higher than other groups at 96 h (p<0.05). In the anaerobic condition of cooled-preserved semen, the results of TM and PM at different concentrations of SP were similar to the results in the aerobic condition although there was a difference in the ratio. The pregnancy rates of fresh-cooled, cooled-preserved and frozen semen were 66.3%, 60.7% and 34.5%, respectively, and the pregnancy rate of frozen semen was the lowest. We also found that it is possible to pregnancy after artificial insemination using 72 h cooled-preserved equine semen. There was similar of the pregnancy rates in the different month from April to August.

후열처리 과정에서 냉각조건에 따른 Bi계 초전도선재의 임계특성 (Critical Properties of Bi Superconducting Wire with Cooling Condition in the Sintering Process.)

  • 김민기;최효상;정동철;최명호;한병성
    • 대한전기학회논문지
    • /
    • 제43권6호
    • /
    • pp.958-964
    • /
    • 1994
  • To study on the superconducting properties with cooling conditions, silver-sheathed Bi-Pb-Sr-Ca-Cu-O wires fabricated by the powder-in-tube method. The wires cooled down in the furnace, air and liquid NS12T after sintering at 840$^{\circ}C$ Critical current density of sample cooled in the furnace is 5.1${\times}$10S03TA/cmS02T and sample cooled in the air is 40A/cmS02T at 77K, zero magnetic field. The latter is very low critical current density of Bi system. 2223 high-Tc superconducting phase of sample cooled in the air was distroyed. Properties of sample cooled down in the liquid nitrogen is the same as cooled in the furnace.

대기 조건에 따른 공랭식 응축기 성능 저하 개선 연구 (Study on Performance Improvement Air Cooled Condenser Considering Ambient Condition)

  • 차훈;류광년;김정래
    • 대한기계학회논문집 C: 기술과 교육
    • /
    • 제3권3호
    • /
    • pp.201-207
    • /
    • 2015
  • 공랭식 응축기(ACC, Air Cooled Condenser)는 공기를 냉매로 이용하여 저압 스팀을 응축하는 설비로써 사막이나 내륙 등 물이 부족한 지역에서 주로 사용된다. 공랭식 응축기의 성능은 풍속이나 대기온도와 같은 외기 조건에 의해 크게 영향을 받으므로 성능 저하 개선을 위해 여러 장치들이 설치된다. 본 연구에서는 풍속에 의한 ACC 성능 변화를 확인하고 윈드 스크린에 의한 성능 개선 효과를 분석하기 위해 CFD 해석을 수행하였다. CFD 는 질량 보존, 운동량 보존 등 미분방정식을 차분방정식으로 변환하여 검사 체적에 대해 속도, 온도 등을 계산하는 기법이다. 풍속이 3m/s 에서 7m/s 로 상승할 때, ACC 에 설치된 팬 공급 유량은 약 15.76% 감소하며 ACC 유입 공기 온도는 $5.55^{\circ}C$ 증가한다. 윈드 스크린을 적절히 설치한 경우, 풍속이 7m/s 이고 윈드 스크린이 설치되지 않은 경우에 비해 팬 공급 유량이 약 5.18% 증가하며 ACC 유입 공기 온도 상승은 $2.08^{\circ}C$ 감소하는 효과가 있다.

중대형 스크루 압축기의 성능에 관한 연구 (A study of the performance on large capacity screw compressors)

  • 박동성;양승현;이동주;신정관;유성연
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집E
    • /
    • pp.668-671
    • /
    • 2001
  • For the saving of energy consumption, it is necessary that the high efficient energy transfer machine. We found the optimum operating condition of screw water chiller during this performance test. The specifications of compressor for this performance test are as follows. Built-in volume ratio; Vi=2.4, using refrigerant; HCFC-22, nominal motor output; 60kW(80Hp). We found the test results on water cooled chiller standard test condition that the evaporating capacity is increased 8% maximum and 5.6% under same operating condition. and COP is increased 11 % max. and 8% under same operating condition with change of the evaporating inlet/outlet condition. For the results of these test, we can estimate the optimum operating condition of water cooled type screw chiller.

  • PDF

신경회로망을 이용한 극저온 절삭특성의 예측 (The Prediction of the Cutting Characteristics in Cryogenic Cutting Using Neural Network)

  • 김칠수;오석영;오선세
    • 한국정밀공학회지
    • /
    • 제13권10호
    • /
    • pp.62-70
    • /
    • 1996
  • We experimented on cutting characteristics-cutting force, behavior of cutting temperature, surface roughness. chip thickness under low temperature, which generated by liquid nitrogen(77K). The work-pieces were freezed to-195 .deg. C and liquid nitrogen was also sprinkled on cutting area in order to decrease an experimental error of machining in low temperature. The workpiece was became to -195 .deg. C in5 minutes. In cooled condition surface roughness of workpiece was better than normal condition. In addition, we investigated the possibility that surface roughness of workpiece and cutting force can be predicted analyzing cutting conditions by the trained neural network.

  • PDF