• 제목/요약/키워드: Coolant Deficiency

검색결과 3건 처리시간 0.018초

연료전지 차량 스택 냉각수 부족 감지 방법에 관한 연구 (A Study on Sensing Method of the Stack Coolant Deficiency for FCEV)

  • 김형국;한수동;남기영;김치명;박용선
    • 한국수소및신에너지학회논문집
    • /
    • 제25권5호
    • /
    • pp.525-532
    • /
    • 2014
  • The sensing of a stack coolant deficiency is very important in that cooling performance of a fuel cell, overheating prevention of a stack or coolant heater. This paper explains the performance comparison between the coolant contact/noncontact level sensors and coolant deficiency sensing logic using the pressure sensor in a stagnant or circulating flow. Throughout the comparison, the pressure sensor is more suitable than the other sensors in terms of the precision, fast response, sensing frequency. After the experiment, the pressure sensor is equipped to an FCEV(Fuel Cell Electric Vehicle) to verify sensing definitely. There was no miss-sensing using pressure sensor while FCEV runs in the conditions of the paved road and cross country road.

Pancake coil형 고온초전도 기기의 응용을 위한 극저온 냉매의 절연파괴 특성 (Breakdown Properties of Cryogenic Coolant for Pancake Coil Type High $T_{c}$ Superconducting Equipment)

  • 백승명;정종만;이진호;김상현
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2002년도 학술대회 논문집
    • /
    • pp.185-188
    • /
    • 2002
  • In the design of superconducting power equipments such as transformer, cable and fault current limit, knowledge of the dielectric behavior of both liquid and gaseous at very low temperatures is very importance. Especially, Electrical properties of liquid nitrogen($LN_{2}$) and gaseous nitrogen($GN_{2}$) have become of great interest again since the discovery of high temperature superconductors. However, many sources of $LN_{2}$and $GN_{2}$ problems in the test of pancake coil model arising form the deficiency of insulation data. Therefore, this paper describes the results of an experimental study on the ac breakdown voltage($V_{B}$) properties of $LN_2$ and Air under the electrode of simulated HTS pancake coil. The ac breakdown voltage of $GN_{2}$ have been measured by pancake coil-pancake coil gaps over the temperature range of 293 K to 77 K.

  • PDF

가압경수로의 저수위 운전시 잔열제거계통 상실사고에 대한 분석 (An Analysis of the Loss of Residual Heat Removal System Event for Pressurized Water Reactor at Reduced Inventory Operation)

  • Han, Kee-Soo;Song, Jin-Ho
    • Nuclear Engineering and Technology
    • /
    • 제27권5호
    • /
    • pp.645-660
    • /
    • 1995
  • 표준원전을 대상으로하여 저수위 운전시의 잔열제거제통상실사고를 RELAP5/MOD3 및 RELAP5/MOD3.1 전산프로그램을 이용하여 분석하였다. 증기발생기가 이용가능할 때 원자로냉각재계통에 배기 경로가 없는 경우와 배기경로가 있는 경우에 대하여 분석을 수행하였다. 배기경로가 없는 경우에 대해 RELAP5 /MOD3 전산프로그램과 RELAP5 /MOD3.1 전산프로그램으로 비교 분석을 수행하였다. 분석 결과 두 전산프로그램의 계산결과는 정성적인 면 뿐 아니라 정량적 인면도 비교적 잘 일치하였다. 그러나 계산결과로부터 RELAP5 /MOD3의 경우에는 벽 열전달모델의 결함이 발견되어 배기경로가 있는 경우에 대해서는 RELAP5 /MOD3.1 전산프로그램을 이용하여 분석을 수행하였다. 분석결과 원자로정지후 하루가 지났을때 배기경로가 없는 경우에는 두개의 증기발생기로도 잔열이 충분히 제거되지 않아 원자로계통의 압력이 지속적으로 증가하여 사고개시 후4,000초 정도에 원자로계통의 임시밀봉재의 설계압력인 0.24MPa에 도달하였다. 가압기 안전밸브 용량의 세배정도 크기의 배기경로가 있는 경우에는 10,000 초가 지나도 원자로냉자재계통의 압력이 0.24 MPa에 도달하지 않았으며 노심노출이 초래되지 않았다. 분석결과의 상세한 검토를 통해서 저수위 운전시 잔열제거능력 상실사고가 발생하였을 경우 REL-AP5/MOD3.1을 이용한 사고해석 방법론의 타당성을 제안하였으며 또한 적절한 배기용량을 산정하기 위한 자료를 제공하였다.

  • PDF