• 제목/요약/키워드: Cool-down characteristics

검색결과 60건 처리시간 0.024초

초기충전압력이 쥴톰슨냉동기의 강온에 미치는 영향 (Effects of the initial charging pressure of gas on the cool-down characteristics of the Joule-Thomson cryocooler)

  • 홍용주;박성제;최영돈
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2160-2164
    • /
    • 2008
  • Miniature Joule-Thomson cryocoolers have been widely used for rapid cooling of infrared detectors, probes of cryosurgery, thermal cameras, missile homing head and guidance system, due to their special features of simple configuration, compact structure and rapid cool-down characteristics. The cool-down time, the temperature at the cold end, the running time and the gas consumption are the important indicators of the performance of the J-T cryocooler. In this study, the initial cool-down stages of the J-T cryocooler were investigated by numerical simulations. The results show the effects of the initial charging pressures of gas on the cool-down time and the temperature at the cold end and the gas consumptions.

  • PDF

한국형발사체 7톤급 액체로켓엔진 냉각 특성 (Cool Down Characteristics of 7 Tonf-class Liquid Rocket Engine for KSLV-II)

  • 임지혁;유병일;이광진;한영민
    • 한국추진공학회지
    • /
    • 제25권1호
    • /
    • pp.50-57
    • /
    • 2021
  • 한국형발사체에 사용되는 액체로켓엔진과 같이 극저온 추진제를 사용하는 엔진은 시험 전 시험설비 배관 및 엔진 냉각이 필수적으로 선행되어 엔진 입구 온도를 만족시켜야 한다. 본 논문에서는 한국형발사체 7톤급 액체로켓엔진의 시험 전 냉각 단계에서 소모되는 액체산소의 양을 확인하였고, 시험설비 배관 및 엔진 냉각특성을 평가하였다.

수소액화용 직접냉각장치의 설계 및 성능시험 (Design and Performance Test of a Direct Cooling Equipment for Hydrogen Liquefaction)

  • 백종훈;강병하;장호명
    • 한국수소및신에너지학회논문집
    • /
    • 제7권2호
    • /
    • pp.121-128
    • /
    • 1996
  • 수소액화를 위한 직접냉각장치를 개발하고, 이의 성능특성을 시험하였다. 직접냉각장치는 액화용기, 복사쉴드, 저온조와 GM냉동기 등으로 구성하였다. 개발된 액화장치의 cool-down 및 warm-up특성이 상세하게 규명되었다. 본 냉각장치에서 냉각이 시작된지 약 45분 후, 액화용기내의 수소가 액화되기 시작함을 확인하였다. 또한 동일한 실험을 기체헬륨에 대하여 수행하였으며, 기체헬륨은 주어진 작동조건에서 액화되지 않으므로 수소의 경우와는 다른 cool-down 및 warm-up 특성을 보였다. 충전된 기체의 자연대류현상의 영향을 고찰하기 위하여 액화용기내에 진공상태를 유지하면서 시험하였다. 이때 진공상태에서의 액화용기의 냉각시간은 현저히 증가함을 보였다.

  • PDF

직접냉각에 의한 수소액화장치의 성능실험 (Performance experiment of a hydrogen liquefaction equipment by direct cooling)

  • 백종훈;강병하;장호명
    • 설비공학논문집
    • /
    • 제9권3호
    • /
    • pp.284-291
    • /
    • 1997
  • A hydrogen liquefaction equipment by direct cooling has been designed and built at KIST. Cool-down characteristics and liquefaction performance of the equipment have been investigated. The hydrogen liquefaction equipment consists of a GM refrigerator, a liquefaction velssel, a radiation shield and a cryostat. It is found that the hydrogen starts to be liquefied in the liquefaction vessel after 40~50 minutes of cool-down from the gas state of 270K. The effect of natural convection phenomena of charged gas in liquefaction vessel on the cool-down characteristics is evaluated by comparing with those in vacuum of liquefaction vessel. It is seen that the cool-down time of a liquefaction vessel is substantially increased in vacuum environment of liquefaction vessel. The experiments have been performed for 1~5 atm of hydrogen pressure to investigate the influence of hydrogen pressure on the liquefaction rate and figure of merit(FOM). It is found that both liquefaction rate and FOM are increased as the charged hydrogen pressure is increased.

  • PDF

차량 내부 탑승자의 쾌적성 평가를 위한 초기 냉방운전 성능에 대한 수치해석적 연구 (Numerical Analysis on the Initial Cool-down Performance Inside an Automobile for the Evaluation of Passenger's Thermal Comfort)

  • 김윤기;양장식;백제현;김경천;지호성
    • 한국자동차공학회논문집
    • /
    • 제18권5호
    • /
    • pp.115-123
    • /
    • 2010
  • Cool-down performance after soaking is important because it affects passenger's thermal comfort. The cooling capacity of HVAC system determines initial cool down performance in most cases, the performance is also affected by location, and shape of panel vent, indoor seat arrangement. Therefore, optimal indoor designs are required in developing a new car. In this paper, initial cool down performance is predicted by CFD(computational fluid dynamics) analysis. Experimental time-averaging temperature data are used as inlet boundary condition. For more reliable analysis, real vehicle model and human FE model are used in grid generation procedure. Thermal and aerodynamic characteristics on re-circulation cool vent mode are investigated using CFX 12.0. Thermal comfort represented by PMV(predicted mean vote) is evaluated using acquired numerical data. Temperature and velocity fields show that flow in passenger's compartment after soaking is considerably unstable at the view point of thermodynamics. Volume-averaged temperature is decreased exponentially during overall cool down process. However, temperature monitored at different 16 spots in CFX-Solver shows local variation in head, chest, knee, foot. The cooling speed at the head and chest nearby panel vent are relatively faster than at the knee and foot. Horizontal temperature contour shows asymmetric distribution because of the location of exhaust vent. By evaluating the passenger's thermal comfort, slowest cooling region is found at the driver's seat.

LNG 저장탱크 종합 열유동 해석프로그램 개발 (Program Development on the Thermofluidodynamic Analysis of LNG Storage Tanks)

  • 김호연;최성희;이정환;박영;하종만;주상우
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.683-688
    • /
    • 2001
  • Cryogenic LNG(Liquefied Natural Gas) which is stored in the cylindrical storage tanks of $100,000m^{3}$ has very complex flow phenomena and the changes of thermal properties with exterior conditions and operation mdoes. These complex thermofluid behaviors are affected by the storage, exterior conditions of LNG, design specifications and heat transfer characteristics of tanks, Also, those have influence on the stable storage and supply of LNG in the storage tanks. Thus this study performed the analysis on the 2-D heat transfer of the tank with exterior conditions, on the Cool Down Process in order to cool down the LNG Storage Tank at the initial normal state, and on the Filling Process considered for incoming and rising of LNG. The analysis on the Mixing LNG Storage was studied too. At last, the visualized program on the complex thermofluidodynamic analysis was developed on the basis of the above analyses. The development of this program becomes to be used to the basic design of the commercial tanks as well as to assure technical skill of the analysis on the thermal stability of the stored LNG in the LNG Storage Tank.

  • PDF

액체질소에서의 극저온 절연매질의 Warm-up/Cool-down 특성 (Warm-up and Cool-down Characteristics of Cryogenic Insulation Materials in Liquid Nitrogen)

  • 이상화;신우주;;오석호;성재규;이방욱
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.119-119
    • /
    • 2010
  • Among the various factors influencing the service life of the electric equipment, the performance of dielectric insulation materials has an important role to determine their whole service life. In order to determine the degradation of insulating materials immersed in extremely low temperature media such as liquid nitrogen, the abrupt temperature change from cryogenic to normal room temperature should be considered. But the assessments of low-temperature aging test method for the dielectric materials immersed in liquid nitrogen considering these conditions were not fully reported. Therefore, for the fundamental step to establish the suitable degradation test methods for cryogenic dielectric materials, we focused on the evaluation of ageing test methods for dielectric materials exposed to low temperature environments considering thermal shock by cool-down and warm up test.

  • PDF

일방향 주기적 진동하는 원통 내의 유동 및 열전달 연구 (A Study on Flow and Heat Transfer in One Directional Periodic-Oscillating Cylinder)

  • 박준상
    • 한국유체기계학회 논문집
    • /
    • 제13권5호
    • /
    • pp.22-28
    • /
    • 2010
  • A study has been made of cool-down process on an incompressible fluid contained in a periodically oscillating cylinder when an abrupt cooling of wall temperature is imposed. Characteristics of flow and heat transfer are investigated along the variations of oscillating frequency and amplitude. One found the flow regimes are divided into 4-modes : 1 thermal island mode, 2 thermal island mode, 4 thermal island mode and asymmetry mode. Comprehensive analysis for each mode are given with a physical mechanism on cool-down process.

적외선 센서용 극저온 용기의 냉각특성에 관한 실험적 연구 (An Experimental Study on the Cooling Characteristics of an Infrared Detector Cryochamber)

  • 강병하;이정훈;김호영
    • 설비공학논문집
    • /
    • 제16권10호
    • /
    • pp.889-894
    • /
    • 2004
  • Infrared (IR) detectors are widely used for many applications, such as temperature measurement, intruder and fire detection, robotics and industrial equipment, thermoelstic stress analysis, medical diagnostics, and chemical analysis. Quantum detectors commonly need to be refrigerated below 80 K, and thus a cooling system should be equipped together with the detector system. The cooling load, which should be removed by the cooling system to maintain the nominal operating temperature of the detector, critically depends on the insulation efficiency of the cryochamber housing the detector. Thermal analysis of cryochamber includes the conduction heat transfer through a cold well, the gases conduction and gas outgassing, as well as radiation heat transfer, The transient cooling characteristics of an infrared detector cryochamber are investigated experimentally in the present study. The transient cooling load increases as the gas pressure is increased. Gas pressure becomes significant as the cooling process proceeds. Cool down time is also increased as the gas pressure is increased. It is also found that natural convection effects on cool down time become significant when the gas pressure is increased.