• Title/Summary/Keyword: Cool-Heating

Search Result 101, Processing Time 0.032 seconds

The R&D of hot water production by the combination of solar thermal and a large sized flower cooling system(I) (꽃 저장용 냉장시스템과 태양열 복합형 급탕기 개발연구(I))

  • Jung, Hyun-Chai;Kim, Ki-Sun;Sun, Kyung-Ho
    • Solar Energy
    • /
    • v.12 no.3
    • /
    • pp.84-93
    • /
    • 1992
  • Solar assisted heat pump with freon circulating system has been developed. Revising the cool chamber(flower storage) with the solar thermal hot water producing system, the more amount of hot water can be produced, which can be even used for room panel heating. The compressor was cooled by water jaket instead of air cooled so that the system energy efficiency was improved quite well.

  • PDF

A Study on the Optimum Thermal Environmental Conditions in floor Heating (바닥난방의 쾌적한 온열환경조건에 관한 연구)

  • BongAeKim
    • Journal of the Korean housing association
    • /
    • v.4 no.2
    • /
    • pp.55-62
    • /
    • 1993
  • 지금까지 연구해 온 바닥난방이 인체에 미치는 생리적, 심리적 영향에 관한 실험결과를 종합하여(건강한 여자를 피험자로 한 경우) 바닥난방의 Optimum Thermal Environmental Conditions 를 검토할 때는 다음의 조건을 만족시켜야 한다. (1) 저온 화상의 위험성을 고려하여 접촉부위의 피부온도가 $40^{\circ}C$를 넘지 않을 것. (2) 생리적 영향으로써 평균 피부온도가 $33{\;}-{\;}34^{\circ}C$의 범위일 것. (3) 심리적 영향으로써 온냉감 평가가 열적중성(slightly cool - slightly warm)으로 평가하고, 쾌적감 평가가 쾌적한 것으로 평가할 것. (4) 바닥온도에 대한 만족감 평가가 높을 것. (5) 흑구온도는 직접바닥에 앉는 자세에서는 $17^{\circ}C$ 이상, 의자에 앉는 자세에서는 $19^{\circ}C$ 이상일 것. 이상의 조건을 만족시키는 범위가 바닥난방의 Optimum Thermal Environmental Zone (Fig.7) 이라고 생각된다.

  • PDF

Improvement of Flow Characteristics for Thin-Wall Injection Molding by Rapid Beating (급속 가열에 의한 박육 사출성형의 유동특성 개선)

  • Kim, Byung;Park, Keun
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2005.09a
    • /
    • pp.9-12
    • /
    • 2005
  • The rapid thermal response (RTR) molding is a novel process developed to raise the temperature of mold surface rapidly to the polymer melt temperature prior to the injection stage and then cool rapidly to the ejection temperature. The resulting filling process is achieved inside a hot mold cavity by prohibiting formation of frozen layer so as to enable thin wall injection molding without filing difficulty. The present work covers flow simulation of thin wall injection molding using the RTR molding process. In order to take into account the effects of thermal boundary conditions of the RTR mold, coupled analysis with transient heat transfer simulation is suggested and compared with conventional isothermal analysis. The proposed coupled simulation approach based on solid elements provides reliable thin wall flow estimation fur both the conventional molding and the RTR molding processes

  • PDF

A Hydrodynamical Simulation of the Off-Axis Cluster Merger Abell 115

  • Lee, Wonki;Kim, Mincheol;Jee, Myungkook James
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.43 no.2
    • /
    • pp.38.1-38.1
    • /
    • 2018
  • A merging galaxy cluster is a useful laboratory to study many interesting astrophysical processes such as intracluster medium heating, particle acceleration, and possibly dark matter self-interaction. However, without understanding the merger scenario of the system, interpretation of the observational data is severely limited. In this work, we focus on the off-axis binary cluster merger Abell 115, which possesses many remarkable features. The cluster has two cool cores in X-ray with disturbed morphologies and a single giant radio relic just north of the northern X-ray peak. In addition, there is a large discrepancy (almost a factor of 10) in mass estimate between weak lensing and dynamical analyses. To constrain the merger scenario, we perform a hydrodynamical simulation with the adaptive mesh refinement code RAMSES. We use the multi-wavelength observational data including X-ray, weak-lensing, radio, and optical spectroscopy to constrain the merger scenario. We present detailed comparisons between the simulation results and these multi-wavelength observations.

  • PDF

Application of District Cooling System for Deep Ocean Water by Case Study (사례 분석을 통한 해양심층수의 지역냉방시스템 적용 방안)

  • Jin, Su-Hwuy;Park, Jin-Young;Kim, Sam-Uel;Kim, Hyeon-Ju
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.04a
    • /
    • pp.179-184
    • /
    • 2011
  • The development of new energy has attracted consideration attention due to the high oil price and environmental problems. In advanced country, they have tried to carry out a long range plan for energy. We need to develop new energy for Low Carbon Green Growth in Korea. The building is 30% among ratio of energy consumption in Korea. And in the past, heating energy was high ratio for energy using at home. But recently, the demand for cooling energy keeps growing due to rising average temperature on the earth and improvement of life quality. In this situation, the energy of lake water and ocean water has studied to utilize in advanced country because of low temperature at underwater. But the study for deep water is still a lot left to do. In this study, we analyzed district cooling system and the present condition. Analyzing the deep lake water cooling system in Toronto, we found an application of district cooling system using deep ocean water. Deep lake water uses heat source for district cooling and water source for city in Toronto. So reducing the initial cost, this city had economic effect. When DLWC was applied at existing building, the heat exchanger was installed instead of cooling tower and refrigerator. And the heat exchanger used to connect main pipe with cool water on city. System using deep ocean water can be applied as a similar way to supply cool water from lake to building.

  • PDF

The Effect of Shade Net on Summer Stress of Cool-season Turfgrass (차광이 반지형 잔디의 여름철 하고현상 감소에 미치는 영향)

  • 이재필;김석정;서한용;이상재;김태준;김두환
    • Asian Journal of Turfgrass Science
    • /
    • v.15 no.2
    • /
    • pp.51-64
    • /
    • 2001
  • Summer stress is one of the serious problems on cool-season grass at the soccer fields in Korea during heavy rainy season. This study was conducted to intestigate the effect of shade net with regard to its percent (0, 50, 75), color (black, green), height (0 cm, 30 cm) and time (7 hr, 24 hr) on turf canopy temperature, light intensity, leaf color, turf performance, clipping yield and root dry weight of cool-season turfgrass. Turf canopy temperature was 6~13$^{\circ}C$ under black and green shade net when temperature was over 4$0^{\circ}C$. Light intensity was also decreased from 40 to 94% under black and green shade net compared to control. Black shade net was more effective than green net in reduction of temperature and light intensity. Green shade net was found to be better for photosynthesis of cool-season grass. Leaf color, turf performance, clipping yield, and root dry weight were better and increased under 50% and 75% shade net. 50% black shade net with 30cm height and 7 hr treatment showed the best turf performance. It can be concluded that 50% and 75% green shade net can be used fur reducing summer stress on cool-season grass after soccer marches during heavy rain season. The shade net decreased the turf canopy temperature and reduced heating damage of cool-season turfgrass.

  • PDF

A study of geothermal heat dump for solar collectors overheat protection (태양열 집열관 과열방지를 위한 지중열교환기 연구)

  • Hwang, Hyun-Chang;Chi, Ri-Guang;Lee, Kye-Bock;Rhi, Seok-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.7
    • /
    • pp.616-622
    • /
    • 2016
  • The heating load using solar hot water is lower in summer than in the other seasons. This decreased heating load leads to the overheating solar collectors and related components. To prevent overheating of the solar collectors, air cooling and shading shields were used. On the other hand, it requires additional mechanical components, and reduces the system reliability. The geothermal heat dump system to release the high temperature heat (over $150^{\circ}C$) transferred from the heat pipe solar collectors was investigated in the present study. Research on the heat dump to cool the solar collector is rare. Therefore, the present study was carried out to collect possible data of a geothermal heat dump to cool the solar collector. A helical type geothermal heat exchanger was buried at a 1.2m depth. Experimentally and numerically, the geothermal heat dump was investigated in terms of the effects of parameters, such as the quantity of solar radiation, aperture area of the collector and the mass flow rate. A pipe length of 50m on the geothermal heat exchanger was suitable with a 0.33 kg/s flow rate. The water reservoir was a possible co-operation solution linked to the geothermal heat exchanger.

Effect of Undersoil Heating on Growth and Mineral Contents of Turfgrasses in Simulated Athletic Field During Winter Season (겨울철 지하부의 가온처리가 경기장 잔디의 생육 및 무기성분 함량에 미치는 영향)

  • 구자형;이혜정
    • Asian Journal of Turfgrass Science
    • /
    • v.16 no.2
    • /
    • pp.65-73
    • /
    • 2002
  • Studies were conducted to determine the effect of undersoil heating on growth and quality of turfgrasses including Kentucky bluegrass (Poa pratensis L.‘Nuglade’), perennial ryegrass (Lolium perenne L.‘Accent’), tall fescue (Festuca arundinacea Schreb.‘Pixie’), and Korean lawngrass (Zoysia japonica Steud.) in simulated athletic field during winter season in Korea. Mineral contents in clippings of turfgrasses grown at different soil mixtures and temperatures were also analyzed. Undersoil heating (approximately 20$\pm$2$^{\circ}C$) was effective in protecting turfgrasses except Korean lawngrass from freezing injury and discoloration of shoots due to extremely cold temperatures during midwinter. Among turfgrasses grown at undersoil heating zone, tall fescue and perennial ryegrass showed the highest clipping weights and chlorophyll contents, respectively. However, anthocyanin contents of shoots were higher in Kentucky bluegrass. There was little or no difference in clipping weights, chlorophyll contents, anthocyanin contents and greenness of shoots between turfgrasses grown at two soil mixtures composed of 80% sand+10% peat moss+10% soil (v/v/v) and 80% sand+20% pea moss (v/v). Contents of mineral K, Ca and Mg in clippings of cool-season turfgrasses were comparatively higher in a soil mixture composed of 80% sand+10% peat moss+10% soil, but little difference in contents of N and P was observed between two soil treatments. Results indicated that undersoil heating can improve quality of turf surface by thawing soil, melting snow, and maintaining shoot growth and greenness of turfgrasses in sports field during winter season.

Optically Managing Thermal Energy in High-power Yb-doped Fiber Lasers and Amplifiers: A Brief Review

  • Yu, Nanjie;Ballato, John;Digonnet, Michel J.F.;Dragic, Peter D.
    • Current Optics and Photonics
    • /
    • v.6 no.6
    • /
    • pp.521-549
    • /
    • 2022
  • Fiber lasers have made remarkable progress over the past three decades, and they now serve far-reaching applications and have even become indispensable in many technology sectors. As there is an insatiable appetite for improved performance, whether relating to enhanced spatio-temporal stability, spectral and noise characteristics, or ever-higher power and brightness, thermal management in these systems becomes increasingly critical. Active convective cooling, such as through flowing water, while highly effective, has its own set of drawbacks and limitations. To overcome them, other synergistic approaches are being adopted that mitigate the sources of heating at their roots, including the quantum defect, concentration quenching, and impurity absorption. Here, these optical methods for thermal management are briefly reviewed and discussed. Their main philosophy is to carefully select both the lasing and pumping wavelengths to moderate, and sometimes reverse, the amount of heat that is generated inside the laser gain medium. First, the sources of heating in fiber lasers are discussed and placed in the context of modern fiber fabrication methods. Next, common methods to measure the temperature of active fibers during laser operation are outlined. Approaches to reduce the quantum defect, including tandem-pumped and short-wavelength lasers, are then reviewed. Finally, newer approaches that annihilate phonons and actually cool the fiber laser below ambient, including radiation-balanced and excitation-balanced fiber lasers, are examined. These solutions, and others yet undetermined, especially the latter, may prove to be a driving force behind a next generation of ultra-high-power and/or ultra-stable laser systems.

A Study on the Economic Benefit of Urban Parking Lot Tree Shading -In the Case of University of California Davis Parking Lot- (도시 주차장내 수목그늘의 경제적 이익 연구 -미국 캘리포니아 데이비스 대학 주차장을 사례로-)

  • Jang Dong-Su;McPherson E. G.
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.33 no.6 s.113
    • /
    • pp.98-108
    • /
    • 2006
  • The climate of urban area is an unstable type with considerable seasonal variation in precipitation wind speed, and temperature and it grows worse. Besides, ozone is a serious air pollutant in most of large cities. So worldwide, some of large cities are investing in forestry options to offset their climate problems, but lack of information has hindered comparisons of urban un cost effectiveness to other options. This research intends to study the economic benefits of tree shading of 19 parking lots in UCD campus. The economic benefits of tree shading are air conditioning savings, air quality, stormwater run-off, and other benefits. Especially, this study focuses how much the economic benefit of parking lot shading has been increased from 1995 to 2003 year by aerophoto. Some data on dimensions of parking lots and the number, size, tree species, and location of trees around each parking lot was inventoried. Two aerophotos(1995,2003) were used in order to analyze the increasement of tree canopy in 19 parking lots for 8 years. However, increasing coverage of trees and managing them for healthy growth would not be sufficient for avoiding adverse impacts by future climate change. Additional measures should be followed such as an increase of energy use efficiency and development of substitute energy. For example, coverage of trees help to save cooling energy by blocking solar radiation reaching parking cars and building structures through shading, and creating cool micro-climates through evapotranspiration. They also reduce heating demand by decreasing air infiltration and heat conduction out of the interior of buildings. Proper arrangement of vegetation over the parking lots can reduce cooling and heating costs. So proper planting design around hard space paving including species selection and location can significantly save cooling and heating energy. And a reduction in car and building's heating and cooling costs results in the reduction in energy demand which causes to emissions of air pollutants. Total increased tree canopy from 1995 to 2003 is $8,470.45m^2$ and the economic benefits is US$ 5,282.10. The economic benefit of one tree has been US$ 7.21 for 8 years. And an annually increased benefit is US$ 0.9 per a tree. If this kind of study is applied to studying the economic benefits of tree canopy in parking lots of Korea, it could result in guidelines of tree planting of parking lots. Because the trees selected for planting in parking lots were not suitable for an environment, the guidelines should contain a recommended list of trees. The guidelines should propose the shading percentage of parking lot when we plan a parking lot and contain the maintenance of trees in order to maximize the economic benefits of tree canopy.