• 제목/요약/키워드: Cool storage system

검색결과 38건 처리시간 0.035초

전도 냉각형 10kJ 고온 초전도 에너지 저장장치의 열 부하 특성 해석 (Heat load characteristic analysis of conduction cooled 10kJ HTS SMES)

  • 김광민;김아롱;김진근;박해용;박민원;유인근;김석호;심기덕
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.2219_2220
    • /
    • 2009
  • The characteristics of the Superconducting Magnetic Energy Storage (SMES) system are faster response, longer life time, more economical, and environment friendly than other Uninterruptible Power Supply (UPS) using battery. Fast charge and discharge time of SMES system can provide powerful performance of improving power quality in the grid. In order to demonstrate the effectiveness of SMES, the authors make a 10kJ SMES system for connection with RTDS (Real Time Digital Simulator). Because the characteristics of superconducting magnet are very important in SMES system, the necessary items such as thermal characteristic, mechanical stress and protection circuit should be considered. In this paper, the authors experimented thermal characteristics of the 10kJ SMES system. The experiment was accomplished using a simulation coils made of aluminium. It has same dimension of the 10kJ class HTS SMES coil. The coil was cooled with GM (Gifford -McMahon) cryocooler through the OFHC (Oxgen Free High thermal Conductivity) conduction bar. The test results of cool down and heat loads characteristics of the simulation coils are described in detail.

  • PDF

I-123 핵종생산장치 시스템 설계 (Design of I-123 Nuclide production system)

  • 정현우;유재준;김병일;전권수;이지섭;박현;최준용;오세영;방상권;이동훈
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2014년도 춘계학술대회
    • /
    • pp.496-499
    • /
    • 2014
  • 30MeV Cyclotron의 양성자가 Xe-124 기체 표적 시스템에 조사될 때 가능한 핵반응을 적용하여 Xe Gas를 GPM으로부터 Target으로 까지 전송하는 시스템을 설계하고 제작하였다. 시스템 설계는 크게 4파트로 나누어 설계하였다. 각각의 하드웨어 부분은 솔리드웍스를 이용하여 설계하였다. Target은 헬륨으로 Havor Foil을 쿨링시키게 설계했고 물은 타겟에 들어간 Xe Gas를 조사 시 높아지는 온도를 식혀주는 역할을 하게 제작하였고 온도센서와 압력센서를 장착하여 눈으로 확인할 수 있게 제작하였다. GPM(Gas Process Manifold)은 Xe Gas를 운반하도록 준비하는 부분이며 Xe Gas를 담고있는 부분과 불순물을 제거하는 부분이 있다. HCS(Helium Circulation System)은 헬륨을 이용하여 각파트를 클리닝 하고 냉각시켜 준다. 이러한 각 부분들을 PLC로 제어하게 하여 유지보수시의 편리성을 추구하였고 PC Vue를 사용하여 SIEMENS PLC를 더욱더 안전하게 인터페이스하게 하였다.

  • PDF

전열교환형 환기시스템을 이용한 학교건물의 나이트 퍼지 적용 효과 분석 (Energy Saving Effect of the Night Purge Control using ERV in a School Building)

  • 김수연;원정관;김재형;송두삼
    • 설비공학논문집
    • /
    • 제28권11호
    • /
    • pp.421-427
    • /
    • 2016
  • The indoor temperature of a building increases during the day due to solar radiation. This behavior is significant in school buildings that are finished with high thermal capacity materials. Moreover, in school buildings, windows cannot be opened until the class has finished owing to the security policy of schools. Consequently, classrooms maintain a high temperature throughout the morning. It is thus important to remove the indoor heat before the commencement of classes in order to reduce the cooling energy needed. The Energy Recovery Ventilator (ERV) system is currently being installed in school buildings for ventilating the classrooms. Night-purge control using ERV can be a good strategy to cool the classroom in advance of the operation of the cooling system. However, the optimal operation method of the ERV for night-purge control has not yet been reported. In this study, the effect of night-purge control with ERV in school buildings is analyzed by simulation method. The results of this study showed that the energy saving effect of night-purge control with ERV is most effective in the case of 2 hours operation prior to the commencement of the first lass and when enthalpy based outdoor air cooling is used.

수소저장합금을 이용한 열수송시스템 구성 (Composition of the heat transportation system using metal hydride)

  • 심규성;명광식;김종원;한상도
    • 한국수소및신에너지학회논문집
    • /
    • 제10권1호
    • /
    • pp.41-48
    • /
    • 1999
  • 산업단지에서 손실되는 막대한 폐열을 효율적으로 회수하고 이를 인근의 배후 도시에서 활용하기 위해서는 이에 적합한 열수송기술이 필요하다. 현재 온수나 증기에 의한 열수송은 배관을 통하여 열손실 및 마찰손실 등이 발생하므로 수송거리는 3 내지 5km가 한계이다. 그러나 대부분의 공단이 도시지역에서 10km 이상 떨어져 있으므로 이들 지역에서 발생되는 폐열을 적절히 활용하기 위해서는 새로운 열수송시스템이 개발되어야 한다. 본 연구에서는 수소저장합금이 수소를 흡수 또는 방출하면서 발열반응과 흡열반응을 일으키는 특성을 이용하여 산업공단지역의 폐열로부터 수소저장합금의 수소를 방출시키고, 이 수소를 인근 도시지역에 파이프라인으로 수송한 후 필요시 또 다른 수소저장합금과 반응시켜 열을 얻을 수 있는 열수송시스템에 대하여 고찰하였다. 이 시스템에서는 난방의 목적 외에도 수소의 흡수 방출온도가 낮은 합금을 이용하여 냉열을 얻을 수도 있으며, 폐열의 저장수단으로, 또한 수소를 수송함으로서 열수송의 수단으로 활용할 수 있다. 이에 따라 수소저장합금을 이용한 열수송기술의 문제점과 열수송시스템의 구성기술에 대하여도 검토하였다.

  • PDF

태양에너지 연구 시험센타 설계 및 효율에 관한 연구 (Design & Performance of the Solar Energy Research & Test Center)

  • 오정무;이종호;최병완;조일식
    • 태양에너지
    • /
    • 제2권2호
    • /
    • pp.29-36
    • /
    • 1982
  • The Solar Energy R&D Department of KIER under the auspice of the Korean government is pushing hard on the development of the passive solar technology with high priority for the expeditious widespread use of solar energy in Korea, since the past few years of experiences told us that the active solar technology is not yet ready for massive commercialization in Korea. KIER has completed the construction of the Solar Energy Research & Test Center in Seoul, which houses the major facilities for its all solar test programs. The Center was designed as a passive solar building with great emphasis on the energy conserving ideas. The Center is not only the largest passive building in Korea, but also the exhibit center for the effective demonstration of the passive heating and cooling technology to the Korean public. The Center was designed to satisfy the requirements based on the technical and economical criteria set by the KIER. Careful considerations, therefore, were given in depth in the following areas to meet the requirements. 1) Passive Heating Concepts The Center employed the combination of direct and indirect gain system. The shape of the Center is Balcomb House style, and it included a large built-in sunspace in front. A partition, consists of transparent and translucent glazings, separates the sunspace and the living space. Since most activities in the Center occur during the day time, direct utilization of the solar energy by the living spaces was emphasized with the limited energy storage capacity. 2) Passive Cooling Concepts(for Summer) Natural ventilation concept was utilized throughout the building. In the direct gain portion of the system, the front glazing can be openable during the cooling season. Natural convection scheme was also applied to the front sunspace for the Summer cooling. Reflective surfaces and curtains were utilized wherever needed. 3) Auxiliary Heat ing and Cooling System As an auxiliary cooling system, mechanical means(forced convection system) were adopted. Therefore forced air heating system was also used to match the duct work requirements of the auxiliary cool ing system. 4) Effect ive Insulation & Others These included the double glazed windows, the double entry doors, the night glazing insulation, the front glazing-frame insulation as well as the building skin insulation. All locally available construction materials were used, and natural lightings were provided as much as possible. The expected annual energy savings (compared to the non-insulated conventional building)of the Center was estimated to be about 80%, which accounts for both the energy conservation and the solar energy source. The Center is being instumented for the actual performance tests. The experimental results of the simplified tests are discussed in this paper.

  • PDF

즉석 이유식 제조시 HACCP의 적용 (HACCP Application of Instant Ablactation Baby Food Processing)

  • 이정규;노완섭
    • 한국식품영양학회지
    • /
    • 제14권5호
    • /
    • pp.457-466
    • /
    • 2001
  • 본 연구에서는 체인점에서 판매되는 즉석 선식 중 위생상 가장 문제가 되는 즉석 이유식의 품질개선을 위하여 HACCP 체계를 적용하였다. 이를 위하여 생산단계를 규명하고, 각 단계의 소요시간과 온도를 측정하였으며, 종업원의 위생관념 기구 및 환경의 위생상태를 관찰하고, 즉석 이유식의 미생물 분석결과를 토대로 중점관리점을 규명하였으며, 이에 대한 통제관리 방법을 연구하였는바 그 결과를 요약하면 다음과 같다. 1. 생산소요시간은 총 9분 30초였으며 그 중 2차 분쇄단계가 4분으로 가장 많은 시간이 소요되었고 원재료의 온도상태는 30.9~31.8$^{\circ}C$였으며 1차 분쇄단계 후 38.6$^{\circ}C$로 가장 높은 온도를 나타내었다. 2. 원재료 및 각 생산단계에 있어서의 제품은 pH 3.9~7.7, 평균 pH 6.2였고, 수분활성 도는 0.23~0.63였으며 평균 0.47이였다. 3. 원재료에 대한 일반세균은 평균 1.4$\times$$10^4$CFU/g, 대장균군은 평균 5.5$\times$10CFU/g이 검출되었으며 생산단계 중의 일반세균 및 대장균군의 증가가 미미하였으나 1차 분쇄단계 이후 일반세균은 8.7$\times$$10^2$CFU/g. 대장균군은 평균 6.9$\times$10 CFU/g으로 급격히 증가하였다. 4. 기구 및 용기의 일반세균 분포는 평균 3.8$\times$$10^4$CFU/$\textrm{cm}^2$, 대장균군은 평균 8.0 $\times$10CFU/$\textrm{cm}^2$이 검출되었으며, 일반세균이 평균 3.7$\times$$10^{5}$ CFU/cm2, 대장균군은 평균 7.7$\times$$10^2$ CFU/$\textrm{cm}^2$가 검출되어 가장 높은 오염도를 나타내었다. 5. 저장온도에 따른 일반세균 및 대장균군의 변화는 4$^{\circ}C$이하에서는 미미하였으나 2$0^{\circ}C$와 3$0^{\circ}C$에서는 증가하는 경향을 나타내었다. 6. 본 연구 결과를 토대로 다음과 같은 사항을 제언하는 바이다. 첫째, 원재료의 보관시간을 최소화하고 저온 보관하여야 하겠으며 둘째, 1차, 2차 분쇄기의 위생적인 관리가 철저히 이루어져야 하겠으며 셋째, 즉석 이유식 생산단계 중 가열공정을 신설하여야 하겠으며 넷째, 생산된 즉석 이유식은 냉장, 냉동 보관하여야 하겠다.다.

  • PDF

수소저장합금을 이용한 열수송시스템 제어기술 연구 (Study on the control technique for the heat transportation system using metal hydride)

  • 심규성;김종원;김정덕;명광식
    • 한국수소및신에너지학회논문집
    • /
    • 제11권1호
    • /
    • pp.43-49
    • /
    • 2000
  • 현재 증기나 온수에 의한 열수송은 배관을 통하여 열손실 및 마찰손실 등이 발생하므로 수송거리는 3 내지 5km가 한계이다. 그러나 대부분의 공단이 도시지역에서 10km 이상 떨어져 있으므로 이들 지역에서 발생되는 폐열을 적절히 활용하기 위해서는 새로운 열수송 시스템이 개발되어야 한다. 수소저장합금은 수소를 흡수 또는 방출하면서 발열반응과 흡열반응을 일으키는 특성을 가지고 있으므로 산업공단지역의 폐열로부터 수소저장합금의 수소를 방출시키고, 이 수소를 인근 도시지역에 파이프라인으로 수송한 후 필요시 또 다른 수소저장합금과 반응시켜 열을 얻을 수 있다. 이 시스템에서는 난방의 목적 외에도 수소의 흡수 방출온도가 낮은 합금을 이용하여 냉열을 얻을 수도 있다. 따라서 수소저장합금은 폐열의 저장이나 열수송의 수단으로 활용할 수 있다. $MmNi_{4.5}Al_{0.5}Zr_{0.003}$, $LaNi_5$, $Zr_{0.9}Ti_{0.1}Cr_{0.6}Fe_{1.4}$, $MmNi_{4.7}Al_{0.1}Fe_{0.1}V_{0.1}$ 합금들이 열수송에 적합한 합금으로 선정되어 그 특성을 검토하였으며, 열수송시스템의 설계 및 제어기술에 대하여 검토하였다.

  • PDF

시설원예를 위한 수평형 지열 히트펌프의 냉방성능 해석 (Cooling Performance of Horizontal Type Geothermal Heat Pump System for Protected Horticulture)

  • 유영선;강연구;강금춘;김영중;백이
    • 생물환경조절학회지
    • /
    • 제17권2호
    • /
    • pp.90-95
    • /
    • 2008
  • 수직형에 비해 비교적 가격이 저렴하고 냉난방을 동시에 할 수 있는 농업시설에 적합한 10RT 규모의 수평형 지열히트펌프 시스템을 $240m^2$ 면적의 온실에 설치하고, 이 시스템의 냉방성능을 분석하였다. 응축기 출구온도가 $40^{\circ}C$에서 $58^{\circ}C$로 상승함에 따라 소비전력은 11.5kW에서 15kw로 상승하였으며, 고압이 1,617kpa에서 2,450kPa로 변화하였다. 냉방성능계수는 지중온도 $25.5^{\circ}C$에서 2.7 수준이었으며 지온이 상승함에 따라 하강하여 $33.5^{\circ}C$에서 2.0 수준이었다. 또한 온실 내부로부터 흡수하는 열량(냉방열량)은 같은 지중온도 수준에서 각각 28.8kW, 26.5kW이었다. 가동 8시간 후 지열교환기가 설치된 60cm깊이의 지온은 $14.3^{\circ}C$가 상승하였으며 150cm는 $15.3^{\circ}C$가 상승하였다. 반면 지열교환기가 매설되지 않은 60cm 깊이는 2.4, 150cm 깊이는 $4.3^{\circ}C$의 지온상승을 보였다. 열매 체유가 지열교환기를 통과한 후 평균 $7.5^{\circ}C$의 온포가 하강하였으며, 토양온도가 평균 $27.5^{\circ}C$ 수준에서 토양으로 방출하는 열량은 평균 46kw로 지중열교환기의 단위 길이 당 약 36.8W의 열량을 방출하는 것으로 분석되었다. 팬코일 유닛이 온실로부터 흡수하는 냉방 열량은 평균 28.2kW이었으며, 열매체유의 온도는 $4.2^{\circ}C$ 상승하였다. 축열조내 열전달매체유의 온도가 $26.0^{\circ}C$에서 $2.0^{\circ}C$까지 하강하는데 3시간이 소요되었으며, 평균 축열율은 29.7kW, 총 축열량은 321MJ이었다. 또한 $2.0^{\circ}C$까지 냉열을 축열한 후 $25.4^{\circ}C$까지 방열되는 시간은 외기온이 평균 $28.5^{\circ}C$일 때 4시간이었고, 총 313.0MJ의 에너지가 방열되었으며, 이때 평균 방열율은 21.7kW인 것으로 분석되었다.