• Title/Summary/Keyword: Conversion Factor

Search Result 982, Processing Time 0.03 seconds

Application of inverse reliability method to estimation of flutter safety factors of suspension bridges

  • Cheng, Jin;Dong, Fenghui
    • Wind and Structures
    • /
    • v.24 no.3
    • /
    • pp.249-265
    • /
    • 2017
  • An efficient and accurate algorithm is proposed to estimate flutter safety factor of suspension bridges satisfying prescribed reliability levels. Uncertainties which arise from the basic wind speed at the bridge deck location, critical flutter velocity, the wind conversion factor from a scaled model to the prototype structure and the gust speed factor are incorporated. The proposed algorithm integrates the concepts of the inverse reliability method and the calculation method of the critical flutter velocity of suspension bridges. The unique feature of the proposed method is that it offers a tool for flutter safety assessment of suspension bridges, when the reliability level is specified as a target to be satisfied by the designer. Accuracy and efficiency of this method with reference to three example suspension bridges is studied and numerical results validate its superiority over conventional deterministic method. Finally, the effects of various parameters on the flutter safety factor of suspension bridges are also investigated.

A study on the characteristics of high power factor AC/DC converter with Feedforward control (Feedforward 제어에 의한 고역률 AC/DC 컨버터의 톡성분석)

  • Kim, Cherl-Jin;Jang, Jun-Young;Yoo, Byeong-Ku;Sin, Seung-Soo;Kim, Young-Tae
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.1244-1246
    • /
    • 2003
  • Conventional Switched Mode Power Supplies(SMPS) with diode-capacitor rectifier have distorted input current waveform with high harmonic content. Typically, these SMPS have a power factor lower than 0.65. To improve with this problem. the power factor correction(PFC) circuit of power supplies has to be introduced. Specially, to reduce size and manufacture cost of power conversion device, the single-stage PFC converter is increased to demand as necessary of study. In this case single-stage PFC converter has been used DC-DC converter with boost converter. However in this paper, it is studied flyback converter of high power factor, high efficiency by feedforward control. Also, the validity of designed and manufactured high power factor flyback converter is confirmed by simulation and experimental results.

  • PDF

Optimal Rotor Blade Design for Tidal In-stream Energy (조류발전용 로터 블레이드의 최적 형상 설계)

  • Yang, Chang-Jo
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.17 no.1
    • /
    • pp.75-82
    • /
    • 2011
  • Marine current energy is one of the most interesting renewable and clean energy resources that have been less exploited. Especially, Korea has worldwide outstanding tidal current energy resources and it is highly required to develop tidal in-stream energy conversion system in coastal area. The objective of study is to investigate harnessing techniques of tidal current energy and to design the a 100 kW horizontal axis tidal turbine using blade element momentum theory with Prandtl's tip loss factor for optimal design procedures. In addition, Influence of Prandtl's tip loss factor at local blade positions as a function of tip speed ratio was studied, and the analysed results showed that power coefficient of designed rotor blade using NACA 63812 was 0.49 at rated tip speed ratio.

Notes on the biomass expansion factors of Quercus mongolica and Quercus variabilis forests in Korea

  • Li, Xiaodong;Son, Yeong-Mo;Lee, Kyeong-Hak;Kim, Rae-Hyun;Yi, Myong-Jong;Son, Yo-Whan
    • Journal of Ecology and Environment
    • /
    • v.35 no.3
    • /
    • pp.243-249
    • /
    • 2012
  • Biomass expansion factors, which convert timber volume (or dry weight) to biomass, are used for estimating the forest biomass and accounting for the carbon budget at a regional or national scale. We estimated the biomass conversion and expansion factors (BCEF), biomass expansion factors (BEF), root to shoot ratio (R), and ecosystem biomass expansion factor (EBEF) for Quercus mongolica Fisch. and Quercus variabilis Bl. forests based on publications in Korea. The mean BCEF, BEF, and R for Q. mongolica was 1.0383 Mg/$m^3$ (N = 27; standard deviation [SD], 0.5515), 1.3572 (N = 27; SD, 0.1355), and 0.2017 (N = 32; SD, 0.0447), respectively. The mean BCEF, BEF, and R for Q. variabilis was 0.7164 Mg/$m^3$ (N = 17; SD, 0.3232), 1.2464 (N = 17; SD, 0.0823), and 0.1660 (N = 8; SD, 0.0632), respectively. The mean EBEF, as a simple method for estimating the ground vegetation biomass, was 1.0216 (N = 7; SD, 0.0232) for Q. mongolica forest ecosystems, and 1.0496 (N = 8; SD, 0.0725) for Q. variabilis forest ecosystems. The biomass expansion factor values in this study may be better estimates of forest biomass in Q. mongolica or Q. variabilis forests of Korea compared with the default values given by the Intergovernmental Panel on Climate Change (IPCC).

Reliability Prediction of High Performance Mooring Platform in Development Stage Using Safety Integrity Level and MTTFd (안전무결성 수준 및 MTTFd를 활용한 개발단계의 고성능 지상체 신뢰도 예측 방안)

  • Min-Young Lee;Sang-Boo Kim;In-Hwa Bae;So-Yeon Kang;Woo-Yeong Kwak;Sung-Gun Lee;Keuk-Ki Oh;Dae-Rim Choi
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.27 no.3
    • /
    • pp.609-618
    • /
    • 2024
  • System reliability prediction in the development stage is increasingly crucial to reliability growth management to satisfy its target reliability, since modern system usually takes a form of complex composition and various complicated functions. In most cases of development stage, however, the information available for system reliability prediction is very limited, making it difficult to predict system reliability more precisely as in the production and operating stages. In this study, a system reliability prediction process is considered when the reliability-related information such as SIL (Safety Integrity Level) and MTTFd (Mean Time to Dangerous Failure) is available in the development stage. It is suggested that when the SIL or MTTFd of a system component is known and the field operational data of similar system is given, the reliability prediction could be performed using the scaling factor for the SIL or MTTFd value of the component based on the similar system's field operational data analysis. Predicting a system reliability is then adjusted with the conversion factor reflecting the temperature condition of the environment in which the system actually operates. Finally, the case of applying the proposed system reliability prediction process to a high performance mooring platform is dealt with.

Dependence of the Gain Factor of the Reflective Polarizer on the Configuration of Optical Sheets

  • Lee, Byung-Woo;Yu, Mi-Yeon;Ko, Jae-Hyeon
    • Journal of Information Display
    • /
    • v.10 no.1
    • /
    • pp.28-32
    • /
    • 2009
  • The correlation between the optical performance of the reflective polarizer, which is a key optical component for the brightness enhancement of the liquid crystal display (LCD), and the configuration of optical sheets was investigated in a direct-lit CCFL (cold-cathode fluorescent lamp) backlight. The optical gain of the reflective polarizer, the polarization state of the light emitted from each film, and the loss factor for the polarization conversion process occurring in the lower part of the backlight were determined using a phenomenological approach for the polarization recycling process. The present study suggests that the correlation between the optical performance of the brightness enhancement films and the backlight configuration should be carefully considered in the optimization of the backlight structure.

Comparative Analysis of Single stage Power Factor Correction Circuit (단상 전원에 적용되는 수동 및 능동 역률개선회로의 특성)

  • Kim, Cherl-Jin;Kim, Choong-Sik;Yoo, Byeong-Kyu;Yoon, Shin-Yong;Baek, Soo-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2004.04a
    • /
    • pp.166-168
    • /
    • 2004
  • Conventional Switched Mode Power Supplies(SMPS) with diode-capacitor rectifier have distorted input current waveform with high harmonic order contents. Typically, these SMPS have a power factor lower than 0,7. To improve with this problem the power factor correction(PFC) circuit of power supplies has to be introduced. Specially, to the reduce size and manufacture cost of power conversion device, the single-stage PFC converter is increased to demand as necessary of study. In this paper, comparative analysis of Valley-fill, boost and feedforward type single stage power factor correction circuit based on the flyback converter is given. Also, the validity of designed three type of single stage PFC circuit are confirmed by simulation and experimental results.

  • PDF

A Study on Fill Factor of Amorphous Silicon Solar Cell (비정질 실리콘 태양전지의 Fill Factor에 관한 연구)

  • Lee, June-Ho;Han, Min-Koo;Lee, Chung-Han
    • Solar Energy
    • /
    • v.7 no.1
    • /
    • pp.35-41
    • /
    • 1987
  • This paper presents a comprehensive computer simulation of hydrogenated amorphous p-i-n silicon solar cells. The physical mechanism governing solar cell operation has been modeled and solved numerically by Runge-Kutta-Gill method. Effects of gap state density, dopant impurity, diffusion length and interface recombination velocity on solar cell performance are investigated. Numerical results show that the electric field in i-region is not uniform but depends strongly on voltage and position. A rather poor fill factor may be due to the electric field variation and short diffusion length. It is found out that the life time should be improved in order to increase a fill factor and a conversion efficiency.

  • PDF