• Title/Summary/Keyword: Convergence Protection Performance

Search Result 104, Processing Time 0.024 seconds

Convergence Performance Evaluation Model for Intrusion Protection System based on CC and ISO Standard (CC와 ISO 표준에 따른 침입방지시스템의 융합 성능평가 모델)

  • Lee, Ha-Yong;Yang, Hyo-Sik
    • Journal of Digital Convergence
    • /
    • v.13 no.5
    • /
    • pp.251-257
    • /
    • 2015
  • Intrusion protection system is a security system that stop abnormal traffics through automatic activity by finding out attack signatures in network. Unlike firewall or intrusion detection system that defends passively, it is a solution that stop the intrusion before intrusion warning. The security performance of intrusion protection system is influenced by security auditability, user data protection, security athentication, etc., and performance is influenced by detection time, throughput, attack prevention performance, etc. In this paper, we constructed a convergence performance evaluation model about software product evaluation to construct the model for security performance evaluation of intrusion protection system based on CC(Common Criteria : ISO/IEC 15408) and ISO international standard about software product evaluation.

Channel Protection Layer Effect on the Performance of Oxide TFTs

  • KoPark, Sang-Hee;Cho, Doo-Hee;Hwang, Chi-Sun;Yang, Shin-Hyuk;Ryu, Min-Ki;Byun, Chun-Won;Yoon, Sung-Min;Cheong, Woo-Seok;Cho, Kyoung-Ik;Jeon, Jae-Hong
    • ETRI Journal
    • /
    • v.31 no.6
    • /
    • pp.653-659
    • /
    • 2009
  • We have investigated the channel protection layer (PL) effect on the performance of an oxide thin film transistor (TFT) with a staggered top gate ZnO TFT and Al-doped zinc tin oxide (AZTO) TFT. Deposition of an ultra-thin PL on oxide semiconductor films enables TFTs to behave well by protecting the channel from a photo-resist (PR) stripper which removes the depleted surface of the active layer and increases the carrier amount in the channel. In addition, adopting a PL prevents channel contamination from the organic PR and results in high mobility and small subthreshold swings. The PL process plays a critical role in the performance of oxide TFTs. When a plasma process is introduced on the surface of an active layer during the PL process, and as the plasma power is increased, the TFT characteristics degrade, resulting in lower mobility and higher threshold voltage. Therefore, it is very important to form an interface using a minimized plasma process.

Convergence Study on Perception and Performance of Patient Private Information Protection in Nursing Students with Clinical Practice (임상실습 경험 간호학생의 환자 개인정보보호 인식과 실천에 대한 융합적 연구)

  • Lee, Hyun-Jung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.4 no.2
    • /
    • pp.53-60
    • /
    • 2018
  • The purpose of this study was to research the perception and performance of patient private information protection(PPIP) of 76 nursing students with clinical practice of 18 weeks. The mean score of perception on PPIP (4.62 points/5 points) was significantly higher than the performance(3.84 points/5 points). There was a statistically significant positive correlation between perception and performance. In the future, it is necessary to study the interdisciplinary convergence study to understand the factors affecting the perception and performance of PPIP of nursing students and to Develope and apply of PPIP education program for nursing students. Also it is necessary to seek joint plans between medical institutions and universities to improve the perception and performance of PPIP.

Convergence Performance Evaluation of Radiation Protection for Apron using the PSNR (최대 신호 대 잡음비를 이용한 방사선 방어용 앞치마의 융복합 성능평가)

  • Kim, Dae-Ho;Kim, Sang-Hyun
    • Journal of Digital Convergence
    • /
    • v.13 no.10
    • /
    • pp.377-383
    • /
    • 2015
  • This study evaluates the convergence radiation protection performance by measuring the PSNR(peak signal-to-noise ratio) values of the image J in the image evaluation program based on increased relative to this exposure of radiation workers.The aim of this study was to evaluate radiation protection performance of apron for design of it's basic information. Method was used to PSNR of Image J program and good condition apron was more than 27dB, the PSNR value of poor condition apron appeared to be less than 24dB. The result is the normality were satisfied distribution and T-test values were statistically significant with p<0.001. Results of evaluation of the performance protective apron through the more easily accessible experimental conditions and methods in the clinical was confirmed distinctly different. in order to reduce the radiation exposure we need to evaluate convergence protection performance and to be having a good performance apron.

Optimization of Yonsei Single-Photon Emission Computed Tomography (YSECT) Detector for Fast Inspection of Spent Nuclear Fuel in Water Storage

  • Hyung-Joo Choi;Hyojun Park;Bo-Wi Cheon;Kyunghoon Cho;Hakjae Lee;Yong Hyun Chung;Yeon Soo Yeom;Sei Hwan You;Hyun Joon Choi;Chul Hee Min
    • Journal of Radiation Protection and Research
    • /
    • v.49 no.1
    • /
    • pp.29-39
    • /
    • 2024
  • Background: The gamma emission tomography (GET) device has been reported a reliable technique to inspect partial defects within spent nuclear fuel (SNF) of pin-by-pin level. However, the existing GET devices have low accuracy owing to the high attenuation and scatter probability for SNF inspection condition. The purpose of this study is to design and optimize a Yonsei single-photon emission computed tomography version 2 (YSECT.v.2) for fast inspection of SNF in water storage by acquisition of high-quality tomographic images. Materials and Methods: Using Geant4 (Geant4 Collaboration) and DETECT-2000 (Glenn F. Knoll et al.) Monte Carlo simulation, the geometrical structure of the proposed device was determined and its performance was evaluated for the 137Cs source in water. In a Geant4-based assessment, proposed device was compared with the International Atomic Energy Agency (IAEA)-authenticated device for the quality of tomographic images obtained for 12 fuel sources in a 14 × 14 Westinghouse-type fuel assembly. Results and Discussion: According to the results, the length, slit width, and septal width of the collimator were determined to be 65, 2.1, and 1.5 mm, respectively, and the material and length of the trapezoidal-shaped scintillator were determined to be gadolinium aluminum gallium garnet and 45 mm, respectively. Based on the results of performance comparison between the YSECT.v.2 and IAEA's device, the proposed device showed 200 times higher performance in gamma-detection sensitivity and similar source discrimination probability. Conclusion: In this study, we optimally designed the GET device for improving the SNF inspection accuracy and evaluated its performance. Our results show that the YSECT.v.2 device could be employed for SNF inspection.

Improvement Plans for Protection Specialist Guard Certification Performance test System (신변보호사 자격검정 실기시험제도의 개선방안)

  • Kang, Dong Beom;Kim, Woo Jun
    • Convergence Security Journal
    • /
    • v.16 no.1
    • /
    • pp.13-21
    • /
    • 2016
  • At the present moment when around 60 years have passed after the introduction of private security, there are security instructor and protection specialist guard as government official recognition qualification. This study discussed problems of secondary performance test system among qualification certification items which have been implement ed as government official recognition qualification since 2013. Current qualification certification for protection specialist guard is composed of primary academic test and secondary performance test. Since it is estimated that it is high time to increase clients' satisfaction and public reliability through strict qualification certification for protection specialist guard. Following improvement plans are intended to suggest. First, it is a plan to divide and diversify difficulties of performance test evaluation events. Second, it is a plan to diversify evaluation criteria of performance test. Third, it is a plan to make criteria for selecting specialized performance test evaluation committee. Fourth, it is a new plan of exclusion system to avoid any relation between performance test evaluation committee and applicants. In this respect, institutional improvement should be followed in order to improve specialty of qualification certification of performance test system for protection specialist guard.

A Study on Establishment of Basic Safety and Essential Performance Criteria of Mobile Computed Tomography (이동형 전산화단층촬영장치의 기본 안전 및 필수 성능 기준을 마련하기 위한 연구)

  • Kim, Eun Hye;Park, Hye Min;Kim, Jung Min
    • Journal of radiological science and technology
    • /
    • v.44 no.3
    • /
    • pp.261-267
    • /
    • 2021
  • As the number of Coronavirus Disease-19 (COVID-19) patients increases in a global pandemic situation, the usefulness of mobile computed tomography (CT) is gaining attention. Currently, mobile CT follows the basic safety and essential performance evaluation criteria of whole-body or limited-view X-ray CT in order to obtain device approval and evaluation in the Republic of Korea. Unlike stationary CT, mobile CT is not operated in shielded areas but rather areas such as intensive care units, operating rooms, or isolation rooms. Therefore, it requires a different basic safety and essential performance evaluation standard than stationary CT. In this study, four derived basic safety evaluation criteria related to electrical, mechanical, and radiation safety were included (dose indication test, protection against stray radiation, safety measures against excessive X-rays, half-value layer measurement); and seven essential performance evaluation criteria were included (tube voltage accuracy, mAs accuracy, radiation dose reproducibility, CT number of water, noise, uniformity, and spatial resolution); total eleven basic safety and essential performance evaluation criteria were selected. This study aims to establish appropriate basic safety and essential performance evaluation criteria for simultaneously obtaining images with diagnostic value and reducing the exposure of nearby patients, medical staff, and radiologic technologists during the use of mobile CT.

Malicious Traffic Protection through MSPI Designing (MSPI설계를 통한 유해 트래픽 차단)

  • Noh, Si-Choon
    • Convergence Security Journal
    • /
    • v.6 no.2
    • /
    • pp.31-42
    • /
    • 2006
  • In this paper, we proposed an integrated infrastructure for optimal information security to resolve these kinds of problems and to implement more powerful protection. The proposed infrastructure presents a security framework, provides a functional mechanism, and implements a scheme for information security based on the design concept of integrated structures. In order to ensure effective malicious traffic blocking, this paper emphasizes that a comprehensive approach through infrastructure improvement and combination of scanning tool is the only measure for preparing against today's environment of virus infiltration. The proposed model is a measure developed at a time when a permanent technological solution to virus is yet to be developed. A performance analysis model is developed and the performance is evaluated through the case studies for the proposed methodology. The effectiveness of the infrastructure for optimal information security needs the continuous diagnostic evaluation and tuning through the users or the organizations.

  • PDF

A Study on Establishment of Essential Performance Evaluation Criteria for C-arm Computed Tomography (C-arm CT의 필수 성능평가 기준 마련을 위한 연구)

  • Kim, Eun-Hye;Park, Hye-Min;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.45 no.2
    • /
    • pp.127-134
    • /
    • 2022
  • In order to overcome the image quality limitations of the conventional C-arm, a flat panel detector (FPD) is used to enhance spatial resolution, detective quantum efficiency, frame rate, and dynamic range. Three-dimensional (3D) visualized information can be obtained from C-arm computed tomography (CT) equipped with an FPD, which can reduce patient discomfort and provide various medical information to health care providers by conducting procedures in the interventional procedure room without moving the patient to the CT scan room. Unlike a conventional C-arm device, a C-arm CT requires different basic safety and essential performance evaluation criteria; therefore, in this study, basic safety and essential performance evaluation criteria to protect patients, medical staff, and radiologists were derived based on International Electrotechnical Commission (IEC) standards, the Ministry of Food and Drug Safety (MFDS) standards in Korea, and the rules on the installation and operation of special medical equipment in Korea. As a result of the study, six basic safety evaluation criteria related to electrical and mechanical radiation safety (leakage current, collision protection, emergency stopping device, overheating, recovery management, and ingress of water or particulate matter into medical electrical (ME) equipment and ME systems: footswitches) and 14 essential performance evaluation criteria (accuracy of tube voltage, accuracy of tube current, accuracy of loading time, accuracy of current time product, reproducibility of radiation output, linearity and consistency in radiography, half layer value in X-ray equipment, focal size and collimator, relationship between X-ray field and image reception area, consistency of light irradiation versus X-ray irradiation, performance of the mechanical device, focal spot to skin distance accuracy, image quality evaluation, and technical characteristic of cone-beam computed tomography) were selected for a total of 20 criteria.

A Study of Student Nurses' Knowledge, Awareness and Performance of Patients' Personal Information Protection (간호대학생의 환자 개인정보보호에 대한 지식, 인식 및 실천정도)

  • Ahn, Sung Mi
    • Journal of Digital Convergence
    • /
    • v.18 no.11
    • /
    • pp.337-345
    • /
    • 2020
  • The Study was conducted to understand the degree of knowledge, awareness and performance of nursing students' patients' personal information protection and to grasp the relationship between them. A convenience sample 262 nursing students was selected from C do, between 1 November and 8 November 2019. Using SPSS Program t-test, one-way ANOVA, Pearson's correlation analysis were performed. Factors that influenced knowledge, awareness and performance included grade, education of information. It is necessary to develop and test programs to ensure an improvement in knowledge and awareness among nursing students to increase their performance.