• Title/Summary/Keyword: Conventional wall

Search Result 693, Processing Time 0.019 seconds

Characteristic Findings of Exercise ECG Test, Perfusion SPECT and Coronary Angiography in Patients with Exercise Induced Myocardial Stunning (게이트 심근관류 SPECT상 운동 유발성 기절심근을 보이는 환자의 운동부하 심전도, 관류 SPECT 및 심혈관 조영술 소견)

  • Ahn, Byeong-Cheol;Seo, Ji-Hyoung;Bae, Jin-Ho;Jeong, Shin-Young;Park, Hun-Sik;Lee, Jae-Tae;Chae, Shung-Chul;Lee, Kyu-Bo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.3
    • /
    • pp.225-232
    • /
    • 2004
  • Purpose : Transient wall motion abnormality and contractile dysfunction of the left ventricle (LV) can be observed in patients with coronary artery disease due to post-stress myocardial stunning. To understand clinical characteristics of stress induced LV dysfunction, we have compared the findings of exercise stress test, myocardial perfusion SPECT and coronary angiography between subjects with and without post-stress LV dysfunction. Materials and Methods : Among subjects who underwent exercise stress test, myocardial perfusion SPECT and coronary angiography within a month of interval, we enrolled 36 patients with post-stress LV election fraction (LVEF) was $\geq5%$ lower than rest (stunning group) and 16 patients with difference of post-stress and rest LVEF was lesser than 1 %(non-stunning group) for this study. Treadmill exercise stress gated myocardial perfusion SPECT was performed with dual head SPECT camera using 740 MBq Tc-99m MIBI and coronary angiography was also performed by conventional Judkins method. Results : Stunning group had a significantly higher incidence of hypercholesterolemia than non-stunning group(45.5 vs. 7.1%, p=0.01). Stunning group also had higher incidence of diabetes mellitus and lower incidence of hypertension, but these were not statistically significant. Stunning group had larger and more severe perfusion defect in stress perfusion myocardial SPECT than non-stunning group(extent 18.2 vs. 9.2%, p=0.029; severity 13.5 vs. 6.9, p=0.040). Stunning group also had higher degree of reversibility of perfusion defect, higher incidence of positive exercise stress test and higher incidence of having severe stenosis ($80{\sim}99%$) in coronary angiography than non-stunning group, but these were not statistically significant. In stunning group, all of 4 patients without perfusion defect had significant coronary artery stenosis and had received revascularization treatment. Conclusion : Patients with post-stress LV dysfunction had larger and more severe perfusion defect and severe coronary artery stenosis than patients without post-stress LV dysfunction. All of the patients without perfusion defect in stunning group had significant coronary artery stenosis and needed revascularization. Therefore, we suggest that invasive diagnostic procedures and therapeutic interventions might be needed in patients with post-stress LV dysfunction.

Effects Of Cultured Bone Cell On The Regeneration Of Alveolar Bone (배양골세포 이식이 치조골재생에 미치는 영향)

  • Jeong, Soon-Joon;Herr, Yeek;Park, Joon-Bong;Lee, Man-Sup;Kwon, Young-Hyuk
    • Journal of Periodontal and Implant Science
    • /
    • v.26 no.1
    • /
    • pp.1-26
    • /
    • 1996
  • This study was performed to estimate the effects of cultured bone cell inoculated on porous type hydroxyaptite for the regeneration of the artificial alveolar bone defect. In this experiment 3 beagle dogs were used, and each of them were divided into right and left mandible. Every surgical intervention were performed under the general anesthesia by using with intravenous injection of Pentobarbital sodium(30mg/Kg). To reduce the gingival bleeding during surgery, operative site was injected with Lidocaine hydrochloride(l:80,000 Epinephrine) as local anesthesia. After surgery experimental animal were feeded with soft dietl Mighty dog, Frisies Co., U.S.A.) for 1 weeks to avoid irritaion to soft tissue by food. 2 months before surgery both side of mandibular 1st premolar were extracted and bone chips from mandibular body were obtained from all animals. Bone cells were cultured from bone chips obtained from mandible with Dulbecco's Modified Essential Medium contained with 10% Fetal Bovine Serum under the conventional conditions. Porous type hydroxyapatite were immerse into the high concentrated cell suspension solution, and put 4 hours for attachin the cells on the surface of hydroxyapatite. Graft material were inserted on the artificial bone defect after 3 days of culture. Before insertion of cellinoculated graft material, scanning electronic microscopic observation were performed to confirm the attachment and spreading of cell on the hydroxyapatite surface. 3 artificial bone defects were made with bone trephine drill on the both side of mandible of the experimental animal. First defect was designed without insertion of graft material as negative control, second was filled with porous replamineform hydroxyapatite inoculated with cultured bone marrow cells as expermiental site, and third was filled with graft materials only as positive control. The size of every artificial bone defect was 3mm in diameter and 3mm in depth. After the every surgical intervention of animals, oral hygiene program were performed with 1.0% chlorhexidine digluconate. All of the animals were sacrificed at 2, 4, 6 weeks after surgery. For obtaining histological section, tissus were fixed in 10% Buffered formalin and decalcified with Planko - Rycho Solution for 72hr. Tissue embeding was performed in paraffin and cut parallel to the surface of mandibular body. Section in 8um thickness of tissue was done and stained with Hematoxylin - Eosin. All the specimens were observed under the light microscopy. The following results were obtained : 1. In the case of control site which has no graft material, less inflammatory cell infiltration and rapid new bone forming tendency were revealed compared with experimental groups. But bone surface were observed depression pattern on defect area because of soft tissue invasion into the artificial bone defect during the experimental period. 2. In the porous hydroxyapatite only group, inflammatory cell infiltration was prominet and dense connective tissue were encapsulated around grafted materials. osteoblastic activity in the early stage after surgery was low to compared with grafted with bone cells. 3. In the case of porous hydroxyapatite inoculated with bone cell, less inflammatory cell infiltration and rapid new bone formation activity was revealed than hydroxyapatite only group. Active new bone formation were observed in the early stage of control group. 4. The origin of new bone forming was revealed not from the center of defected area but from the surface of preexisting bony wall on every specimen. 5. In this experiment, osteoclastic cell was not found around grafted materials, and fibrovascular invasion into regions with no noticeable foreign body reaction. Conclusively, the cultured bone cell inoculated onto the porous hydroxyapatite may have an important role of regeneration of artificial bone defects of alveolar bone.

  • PDF

Implantable Flexible Sensor for Telemetrical Real-Time Blood Pressure Monitoring using Polymer/Metal Multilayer Processing Technique (폴리머/ 금속 다층 공정 기술을 이용한 실시간 혈압 모니터링을 위한 유연한 생체 삽입형 센서)

  • Lim Chang-Hyun;Kim Yong-Jun;Yoon Young-Ro;Yoon Hyoung-Ro;Shin Tae-Min
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.6
    • /
    • pp.599-604
    • /
    • 2004
  • Implantable flexible sensor using polymer/metal multilayer processing technique for telemetrical real-time blood pressure monitoring is presented. The realized sensor is mechanically flexible, which can be less invasively implanted and attached on the outside of blood vessel to monitor the variation of blood pressure. Therefore, unlike conventional detecting methods which install sensor on the inside of vessel, the suggested monitoring method can monitor the relative blood pressure without injuring blood vessel. The major factor of sudden death of adults is a disease of artery like angina pectoris and myocardial infarction. A disease of circulatory system resulted from vessel occlusion by plaque can be preventable and treatable early through continuous blood pressure monitoring. The procedure of suggested new method for monitoring variation of blood pressure is as follows. First, integrated sensor is attached to the outer wall of blood vessel. Second, it detects mechanical contraction and expansion of blood vessel. And then, reader antenna recognizes it using telemetrical method as the relative variation of blood pressure. There are not any active devices in the sensor system; therefore, the transmission of energy and signal depends on the principle of mutual inductance between internal antenna of LC resonator and external antenna of reader. To confirm the feasibility of the sensing mechanism, in vitro experiment using silicone rubber tubing and blood is practiced. First of all, pressure is applied to the silicone tubing which is filled by blood. Then the shift of resonant frequency with the change of applied pressure is measured. The frequency of 2.4 MHz is varied while the applied pressure is changed from 0 to 213.3 kPa. Therefore, the sensitivity of implantable blood pressure is 11.25 kHz/kPa.