• 제목/요약/키워드: Conventional impression

검색결과 107건 처리시간 0.024초

Comparison of the fit of cast gold crowns fabricated from the digital and the conventional impression techniques

  • Yun, Mi-Jung;Jeon, Young-Chan;Jeong, Chang-Mo;Huh, Jung-Bo
    • The Journal of Advanced Prosthodontics
    • /
    • 제9권1호
    • /
    • pp.1-13
    • /
    • 2017
  • PURPOSE. The purpose of this study was to compare the fit of cast gold crowns fabricated from the conventional and the digital impression technique. MATERIALS AND METHODS. Artificial tooth in a master model and abutment teeth in ten patients were restored with cast gold crowns fabricated from the digital and the conventional impression technique. The forty silicone replicas were cut in three sections; each section was evaluated in nine points. The measurement was carried out by using a measuring microscope and I-Soultion. Data from the silicone replica were analyzed and all tests were performed with ${\alpha}$-level of 0.05. RESULTS. 1. The average gaps of cast gold crowns fabricated from the digital impression technique were larger than those of the conventional impression technique significantly. 2. In marginal and internal axial gap of cast gold crowns, no statistical differences were found between the two impression techniques. 3. The internal occlusal gaps of cast gold crowns fabricated from the digital impression technique were larger than those of the conventional impression technique significantly. CONCLUSION. Both prostheses presented clinically acceptable results with comparing the fit. The prostheses fabricated from the digital impression technique showed more gaps, in respect of occlusal surface.

ACCURACY OF THE IMPRESSION TECHNIQUE USING THERMOFORMING POLYMETHYL METHACRYLATE TRAY

  • Miyashita, Yuko;Suzuki, Hiroki;Kishi, Masataka;Ko, Sok-Min
    • 대한치과보철학회지
    • /
    • 제45권3호
    • /
    • pp.389-400
    • /
    • 2007
  • Statement of problem. Use of the conventional dental impression procedure is problematic in patients who have difficulty opening their mouth, difficulty breathing through their nose or tendency to gag. Purpose. It is necessary to make individual trays more comfortable for patients during impression taking procedure. It was reported at the KAP Annual Meeting 2001 Seoul that an improved impression technique was suitable for this purpose. In this study, the accuracy of the improved dental impression method for implant was compared with the conventional dental impression method. Material and methods. An oral simulator was made from clear acrylic resin block which had similar form of edentulous ridge. For setting up the standard, five fixtures were installed on it. Study casts were made using two kinds of impression techniques. One was the conventional method that was taken using silicone impression material and an individual resin tray under connection of inter-fixture relation. The other was the improved method in which was the connection of the impression coping and the thermoformed polymethyl methacrylate tray. In addition, two different study casts were made from the improved impression body. The coordinates of the fixture on the study model were measured by three-dimensional coordinate measuring equipment. Then the distances between each fixture were calculated and compared with that of oral simulator. Accuracy of the each impression method was also assessed. Results. The differences of inter-fixture dimension between study casts and simulator in the improved impression technique showed $0.014{\pm}0.016mm$ and $0.017{\pm}0.022mm$, respectively and that of the conventional method was $0.017{\pm}0.014mm$. There was no significant difference between the improved impression technique and conventional method. Conclusion. The improved impression technique is useful for multiple support implants.

보철 치료 시 디지털 및 전통적 인상채득에 대한 환자 만족도 비교 연구 (Comparison of patient satisfaction with digital and conventional impression for prosthodontic treatment)

  • 윤형인;이수민;박은진
    • 대한치과보철학회지
    • /
    • 제54권4호
    • /
    • pp.379-386
    • /
    • 2016
  • 목적: 본 연구에서는 전통적 인상채득과 디지털 인상채득을 모두 경험한 환자들의 만족도를 조사하여 다양한 항목에 대하여 비교 분석하고자 하였다. 재료 및 방법: 구강 내 디지털 인상채득의 방법을 사용하는 5개의 치과병원에서, 보철 치료를 위해 기존의 인상재를 이용한 방법과 디지털 인상채득을 모두 경험한 만 20세 이상의 성인 환자 170명을 대상으로, 2015년 10월부터 2016년 4월까지 설문조사를 실시하였다. 총128부의 설문지를 분석 자료로 이용하였으며, 빈도분석, 다중응답 빈도분석, 기술통계, 비모수 검정, 교차 분석을 시행하였고, 유의수준은 0.05로 설정하였다. 결과: 디지털 인상채득의 이유는 '임플란트치료'(43.8%), '크라운치료'(30.5%), '인레이치료'(15.6%) 순서로 나타났다. 전통적 인상채득의 평균 만족도보다 디지털 인상채득의 평균 만족도가 유의하게 더 높았다 (P<.05). 재선택하고 싶은 인상채득 방법으로는 전통적 인상채득(11.7%) 보다 디지털 인상채득(60.2%)이 더 높게 나타났다. 디지털 인상채득을 재선택한 이유로는 '구토반사가 없어서'(35.1%), '3D디지털 스캔이라 신뢰가 가서'(33.8%), '시간이짧아서'(33.8%) 순으로 나타났다. 결론: 환자 만족도 및 다시 선택하고 싶은 인상채득의 방법으로 전통적 인상채득 보다 디지털 인상채득의 선택이 더 높게 나타났다.

Evaluation of marginal adaptation in three-unit frameworks fabricated with conventional and powder-free digital impression techniques

  • Kocaagaoglu, Hasan;Albayrak, Haydar;Sahin, Sezgi Cinel;Gurbulak, Aysegul Guleryuz
    • The Journal of Advanced Prosthodontics
    • /
    • 제11권5호
    • /
    • pp.262-270
    • /
    • 2019
  • PURPOSE. The purpose of this in vitro study was to evaluate the marginal misfits of three-unit frameworks fabricated with conventional and digital impressions techniques. MATERIALS AND METHODS. Thirty brass canine and second premolar abutment preparations were fabricated by using a computer numerical control machine and were randomly divided into 3 groups (n=10) as follows: conventional impression group (Group Ci), Cerec Omnicam (Group Cdi), and 3shape TRIOS-3 (Group Tdi) digital impression groups. The laser-sintered metal frameworks were designed and fabricated with conventional and digital impressions. The marginal adaptation was assessed with a stereomicroscope at ${\times}30$ magnification. The data were analyzed with 1-way analysis of variances (ANOVAs) and the independent simple t tests. RESULTS. A statistically significant difference was found between the frameworks fabricated by conventional methods and those fabricated by digital impression methods. Multiple comparison results revealed that the frameworks in Group Ci (average, $98.8{\pm}16.43{\mu}m$; canine, $93.59{\pm}16.82{\mu}m$; premolar, $104.10{\pm}15.02{\mu}m$) had larger marginal misfit values than those in Group Cdi (average, $63.78{\pm}14.05{\mu}m$; canine, $62.73{\pm}13.71{\mu}m$; premolar, $64.84{\pm}15.06{\mu}m$) and Group Tdi (average, $65.14{\pm}18.05{\mu}m$; canine, $70.64{\pm}19.02{\mu}m$; premolar, $59.64{\pm}16.10{\mu}m$) (P=.000 for average; P=.001 for canine; P<.001 for premolar). No statistical difference was found between the marginal misfits of canine and premolar abutment teeth within the same groups (P>.05). CONCLUSION. The three-unit frameworks fabricated with digital impression techniques showed better marginal fit compared to conventional impression techniques. All marginal misfit values were clinically acceptable.

Adaptation of zirconia crowns created by conventional versus optical impression: in vitro study

  • Cetik, Sibel;Bahrami, Babak;Fossoyeux, Ines;Atash, Ramin
    • The Journal of Advanced Prosthodontics
    • /
    • 제9권3호
    • /
    • pp.208-216
    • /
    • 2017
  • PURPOSE. The aim of this study was to compare the precision of optical impression (Trios, 3Shape) versus that of conventional impression (Imprint IV, 3M-ESPE) with three different margins (shoulder, chamfer, and knife-edge) on Frasaco teeth. MATERIALS AND METHODS. The sample comprised of 60 zirconia half-crowns, divided into six groups according to the type of impression and margin. Scanning electron microscopy enabled us to analyze the gap between the zirconia crowns and the Frasaco teeth, using ImageJ software, based on eight reproducible and standardized measuring points. RESULTS. No statistically significant difference was found between conventional impressions and optical impressions, except for two of the eight points. A statistically significant difference was observed between the three margin types; the chamfer and knife-edge finishing lines appeared to offer better adaptation results than the shoulder margin. CONCLUSION. Zirconia crowns created from optical impression and those created from conventional impression present similar adaptation. While offering identical results, the former have many advantages. In view of our findings, we believe the chamfer margin should be favored.

Comparison of accuracy between digital and conventional implant impressions: two and three dimensional evaluations

  • Bi, Chuang;Wang, Xingyu;Tian, Fangfang;Qu, Zhe;Zhao, Jiaming
    • The Journal of Advanced Prosthodontics
    • /
    • 제14권4호
    • /
    • pp.236-249
    • /
    • 2022
  • PURPOSE. The present study compared the accuracy between digital and conventional implant impressions. MATERIALS AND METHODS. The experimental models were divided into six groups depending on the implant location and the scanning span. Digital impressions were captured using the intraoral optical scanner TRIOS (3Shape, Copenhagen, Denmark). Conventional impressions were taken with the monophase impression material based on addition-cured silicones, Honigum-Mono (DMG, Hamburg, Germany). A high-precision laboratory scanner D900 (3Shape, Copenhagen, Denmark) was used to obtain digital data of resin models and stone casts. Surface tessellation language (STL) datasets from scanner were imported into the analysis software Geomagic Qualify 14 (3D Systems, Rock Hill, SC, USA), and scan body deviations were determined through two-dimensional and three-dimensional analyses. Each scan body was measured five times. The Sidak t test was used to analyze the experimental data. RESULTS. Implant position and scanning distance affected the impression accuracy. For a unilateral arch implant and the mandible models with two implants, no significant difference was observed in the accuracy between the digital and conventional implant impressions on scan bodies; however, the corresponding differences for trans-arch implants and mandible with six implants were extremely significant (P<.001). CONCLUSION. For short-span scanning, the accuracy of digital and conventional implant impressions did not differ significantly. For long-span scanning, the precision of digital impressions was significantly inferior to that of the traditional impressions.

Comparison of intraoral scanning and conventional impression techniques using 3-dimensional superimposition

  • Rhee, Ye-Kyu;Huh, Yoon-Hyuk;Cho, Lee-Ra;Park, Chan-Jin
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권6호
    • /
    • pp.460-467
    • /
    • 2015
  • PURPOSE. The aim of this study is to evaluate the appropriate impression technique by analyzing the superimposition of 3D digital model for evaluating accuracy of conventional impression technique and digital impression. MATERIALS AND METHODS. Twenty-four patients who had no periodontitis or temporomandibular joint disease were selected for analysis. As a reference model, digital impressions with a digital impression system were performed. As a test models, for conventional impression dual-arch and full-arch, impression techniques utilizing addition type polyvinylsiloxane for fabrication of cast were applied. 3D laser scanner is used for scanning the cast. Each 3 pairs for 25 STL datasets were imported into the inspection software. The three-dimensional differences were illustrated in a color-coded map. For three-dimensional quantitative analysis, 4 specified contact locations(buccal and lingual cusps of second premolar and molar) were established. For two-dimensional quantitative analysis, the sectioning from buccal cusp to lingual cusp of second premolar and molar were acquired depending on the tooth axis. RESULTS. In color-coded map, the biggest difference between intraoral scanning and dual-arch impression was seen (P<.05). In three-dimensional analysis, the biggest difference was seen between intraoral scanning and dual-arch impression and the smallest difference was seen between dual-arch and full-arch impression. CONCLUSION. The two- and three-dimensional deviations between intraoral scanner and dual-arch impression was bigger than full-arch and dual-arch impression (P<.05). The second premolar showed significantly bigger three-dimensional deviations than the second molar in the three-dimensional deviations (P>.05).

디지털 방식을 이용하여 제작한 전부 지르코니아 수복물의 변연 적합도 평가 (Evaluation of marginal fit of monolithic zirconia restoration by digital impression)

  • 윤미정;김소연;강은숙
    • 대한치과의사협회지
    • /
    • 제56권7호
    • /
    • pp.366-374
    • /
    • 2018
  • Purpose : The purpose of this study was to compare the marginal fit of monolithic zirconia restorations fabricated form the conventional and the digital impression technique. Materials and methods : Ten patients were restored with monolithic zirconia restorations fabricated from the digital and the conventional impression technique. Before definitive insertion, silicone replicas were produced from all twenty crowns. The silicone replicas were cut in three sections; each section was evaluated at two points. The measurement was carried out by using a measuring microscope (Olympus BX 51) and I-Solution. Data from the silicone replica scores were analyzed by Shapiro-Wilk test for normal distribution and the t-test for equality of two population's mean. All tests were performed with ${\alpha}-level$ of 0.05. Results : The average marginal gaps of monolithic zirconia restorations were $133.81{\pm}36.46{\mu}m$ for the conventional impression technique, $90.07{\pm}9.47{\mu}m$ for the digital impression technique. No statistical differences were found between the two impression techniques Conclusion : Both prostheses presented clinically acceptable results with comparing the marginal fit.

  • PDF

새로운 인상용 코핑을 이용한 임플란트 인상법의 정확성에 대한 3차원적 비교 연구 (Three Dimensional Comparative Study On The Accuracy Of Impression Technique Using New Impression Coping)

  • 김세라;김인수;박성재;이병옥;고석민
    • 구강회복응용과학지
    • /
    • 제26권3호
    • /
    • pp.323-337
    • /
    • 2010
  • 본 연구는 임플란트 상부 구조물 제작을 위한 pick-up 인상 채득시 flag type의 새로운 인상용 코핑을 이용하여 제작된 모형과 기존에 사용되고 있는 인상용 코핑에 의해 제작된 모형의 정확성을 3차원적으로 비교하여 새로운 형태의 인상용 코핑을 사용한 인상법의 유용성을 알아보고자 하였다. 아크릴릭 레진 블록으로 좌측은 전부 무치악, 우측은 제 2 소구치가 상실된 상악 기준 모형을 제작하였다. 상악 우측 제 2소구치, 좌측 중절치, 좌측 견치, 좌측 제 2 소구치, 좌측 제 2 대구치 부위에 외부 육각 연결 방식의 임플란트 고정체를 식립하였다. 기준 모형에 사용된 인상용 코핑 및 코핑 간에 연결 여부에 따라 세 가지 실험군으로 분류하였다; 임플란트 고정체에 flag type 의 인상용 코핑을 체결한 경우 (실험군 I), 기존 형태인 원통형의 인상용 코핑을 체결한 후 인상용 코핑을 자가 중합 아크릴릭 레진으로 연결한 경우 (실험군 Ii), 원통형 인상용 코핑을 체결한 후 자가 중합 레진으로 연결하지 않은 경우 (실험군 III). 총 15개의 모형을 제작하여 인상 채득하여 작업 모형을 제작한 후 기준 모형 및 작업 모형을 5번씩 측정하여 통계 처리하였다. flag type의 인상용 코핑을 이용하여 인상 채득한 군, 기존의 인상용 코핑을 자가 중합 레진으로 splinting하여 인상 채득한 군, 기존의 인상용 코핑을 splinting 하지 않고 인상 채득한 군의 작업 모형에서 각 임플란트 유사체 간 거리 차이는 통계적으로 유의하지 않았다(P >.05). 또한 동일 수평면에 대한 수직적 거리를 비교한 결과 flag type의 인상용 코핑을 사용하여 제작한 작업 모형이 Point 2에서는 기준 모형에 가장 근접한 수치를 보였고 Point 3에서는 오차가 가장 컸으며 이는 통계적으로 유의하였다(P <.05). 그 외 Point에서는 세 가지 방법 간에 통계적으로 유의한 차이는 없었다(P >.05). 새로운 인상용 코핑을 사용한 인상법은 기존의 인상용 코핑을 사용한 인상법과 비교적 유사한 정확성을 보여주었다.

디지털 인상법과 종래인상법을 동시에 경험한 임상시험자를 대상으로 한 설문지분석 (Questionnaire survey for the clinical trial participants who experienced both digital and conventional impression)

  • 양은비;김봉주;이준재;이승표;임영준
    • 구강회복응용과학지
    • /
    • 제34권4호
    • /
    • pp.270-279
    • /
    • 2018
  • 목적: 이 연구의 목적은 종래형 인상채득 방법과 디지털 인상채득 방법에 대한 환자들의 느낌, 만족도와 선호도를 설문조사를 통해 비교분석하는 것이다. 연구 재료 및 방법: 이 연구에 참여한 13명의 임상시험자(남자 6명, 여자 7명)는 종래형 인상채득 방법과 디지털 인상채득 방법을 동일에 경험하였다. 종래형 인상채득방법은 폴리비닐실록산(PVS) 인상재를 사용하였고, 디지털 인상채득은 새로 개발된 구강스캐너를 사용하였다. 두 종류의 인상채득을 시행한 직후 바로 설문조사를 진행하였고, 설문조사지는 다음의 세 개의 범주로 구성되었다; 1) 일반적인 치과 진료에 관해 2) 종래형 인상채득방법에 대한 만족도 3) 디지털 인상채득 방법에 대한 만족도. 만족도에 대한 측정은 Likert 척도를 사용하여 평가되었다. 설문조사 응답 중 분포에 관한 것은 백분율을 사용하였고, 비교 만족도에 유의성에 대한 통계분석은 paired t-test 검정을 사용하였으며 통계적 유의수준은 P < 0.05 로 하였다. 결과: 두 가지 인상채득 방법에 대한 전반적인 만족도에서 유의미한 차이가 있었다(P < 0.05). 디지털 인상채득방식이 숨쉬기, 냄새에 대한 항목에서 종래의 인상채득방법에 비해 높은 만족도를 보였다. 다만 구강 스캐너를 사용했을 때 스캐너의 팁 사이즈가 크고 입을 오래 벌리고 있어야 하는 문제로 인해 TMJ에 불편감을 야기했다. 결론: 구강스캐너를 사용하는 디지털 인상채득 방법이 종래의 인상채득방법에 비하여 더 선호되는 것을 확인하였다. 대부분의 조사에서 참가자들이 디지털 인상채득방법을 타인에게 추천할 의향이 있으며, 다음 보철 치료 시에도 디지털 인상채득 방법을 선택할 것이라고 했다.