• 제목/요약/키워드: Conventional coil

검색결과 290건 처리시간 0.031초

전기자동차용 고효율 무선 온보드 충전기의 설계 (Design of the High Efficiency Wireless On-Board Charger for Electric Vehicles)

  • 트란덕홍;부반빈;최우진
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2015년도 추계학술대회 논문집
    • /
    • pp.27-28
    • /
    • 2015
  • In this paper a high efficiency wireless on-board charger for Electric Vehicle (EV) is proposed and the theoretical analysis based on the two-port network model to come up with suitable design for the battery charge application is presented. The proposed Wireless Power Transfer (WPT) method has adopted four-coil system with air core and its superior performance is proved by comparing it to the conventional two-coil system by the mathematical analysis. In addition, since the proposed WPT converter is able to operate at an almost constant frequency regardless of the load, CC/CV charge of the battery can be simply implemented. A 6.6kW prototype is implemented with 20cm air gap to prove the validity of the proposed method. The experimental results show that the dc to dc conversion efficiency of the proposed system achieves 97.08% at 3.7 kW.

  • PDF

온라인 재학습 가능한 RBF 네트워크를 이용한 열연 권취 온도 제어 모델 개발 (Development of a Temperature Control Model for a Hot Coil Strip using on-line Retrainable RBF Network)

  • 정소영;이민호;이수영
    • 전자공학회논문지S
    • /
    • 제36S권8호
    • /
    • pp.39-47
    • /
    • 1999
  • 본 논문에서는 포항제철의 열연 권취 온도 공정을 제어하기 위한 방법으로 온라인 재학습 가능한 RBF 네트워크(Radial Basis Function network)를 제안한다. 새로 제안된 신경회로망 모델을 이용해 권취 온도 제어 시스템의 열전달 계수를 생성해주는 기조의 규칙 기반 계수표를 대체할 수 있다. 열연 공정 작업의 시간에 따른 변화를 고려하도록 지존의 RBF 네트워크에 부가적인 온라인 재학습용 시냅스 가중치를 도입한다. 부가적인 가중치들로 인해 이미 학습된 전체 데이터들의 특성 정보를 유지하면서 새로 들어오는 데이터들에 대해 온라인 재학습이 이루어진다. 따라서, 제안된 RBF 네트워크는 파국적 간섭(catastrophic interference)효과를 상당히 감소시킬 수 있다. 그리고 거부 네트워크을 도입하여 제어기의 신뢰도을 높일 수 있었고, 실제 현장에 적용한 실험 결과는 기존의 방법보다 평균 2.2퍼센트이상 향상된 성능을 보였다.

  • PDF

자장 구조 변화에 따른 High Power Impulse Magnetron Sputtering (HIPIMS)에서 Al-doped ZnO 박막 증착 특성 (Magnetic Field Dependent Characteristics of Al-doped ZnO by High Power Impulse Magnetron Sputtering (HIPIMS))

  • 박동희;양정도;최지원;손영진;최원국
    • 한국재료학회지
    • /
    • 제20권12호
    • /
    • pp.629-635
    • /
    • 2010
  • Abstract In this study characteristics of Al-doped ZnO thin film by HIPIMS (High power impulse sputtering) are discussed. Deposition speed of HIPIMS with conventional balanced magnetic field is measured at about 3 nm/min, which is 30% of that of conventional RF sputtering process with the same working pressure. To generate additional magnetic flux and increase sputtering speed, electromagnetic coil is mounted at the back side of target. Under unbalanced magnetic flux from electromagnet with 1.5A coil current, deposition speed of AZO thin film is increased from 3 nm/min to 4.4 nm/min. This new value originates from the decline of particles near target surface due to the local magnetic flux going toward substrate from electromagnet. AZO film sputtered by HIPIMS process shows very smooth and dense film surface for which surface roughness is measured from 0.4 nm to 1 nm. There are no voids or defects in morphology of AZO films with varying of magnetic field. When coil current is increased from 0A to 1A, transmittance of AZO thin film decreases from 80% to 77%. Specific resistance is measured at about $2.9{\times}10-2\Omega{\cdot}cm$. AZO film shows C-axis oriented structure and its grain size is calculated at about 5.3 nm, which is lower than grain size in conventional sputtering.

Assessment of Diffusion-Weighted Imaging-FLAIR Mismatch: Comparison between Conventional FLAIR versus Shorter-Repetition-Time FLAIR at 3T

  • Goh, Byeong Ho;Kim, Eung Yeop
    • Investigative Magnetic Resonance Imaging
    • /
    • 제20권2호
    • /
    • pp.88-94
    • /
    • 2016
  • Purpose: Fluid-attenuated inversion recovery (FLAIR) imaging can be obtained faster with shorter repletion time (TR), but it gets noisier. We hypothesized that shorter-TR FLAIR obtained at 3 tesla (3T) with a 32-channel coil may be comparable to conventional FLAIR. The aim of this study was to compare the diagnostic value between conventional FLAIR (TR = 9000 ms, FLAIR9000) and shorter-TR FLAIR (TR = 6000 ms, FLAIR6000) at 3T in terms of diffusion-weighted imaging-FLAIR mismatch. Materials and Methods: We recruited 184 patients with acute ischemic stroke (28 patients < 4.5 hours) who had undergone 5-mm diffusion-weighted imaging (DWI) and two successive 5-mm FLAIR images (no gap; in-plane resolution, $0.9{\times}0.9mm$) at 3T with a 32-channel coil. The acquisition times for FLAIR9000 and FLAIR6000 were 108 seconds (generalized autocalibrating partially parallel acquisitions [GRAPPA] = 2) and 60 seconds (GRAPPA = 3), respectively. Two radiologists independently assessed the paired imaging sets (DWI-FLAIR9000 and DWI-FLAIR6000) for the presence of matched hyperintense lesions on each FLAIR imaging. The signal intensity ratios (area of DWI lesion to contralateral normal-appearing region) on both FLAIR imaging sets were compared. Results: DWI-FLAIR9000 mismatch was present in 39 of 184 (21.2%) patients, which was perfectly the same on FLAIR6000. Three of 145 patients (2%) with DWI-matched lesions on FLAIR9000 had discrepancy on FLAIR6000, showing no significant difference (P > 0.05). Interobserver agreement was excellent for both DWI-FLAIR9000 and DWI-FLAIR6000 (k = 0.904 and 0.883, respectively). Between the two FLAIR imaging sets, there was no significant difference of signal intensity ratio (mean, standard deviation; $1.25{\pm}0.20$; $1.24{\pm}0.20$, respectively) (P > 0.05). Conclusion: For the determination of mismatch or match between DWI and FLAIR imaging, there is no significant difference between FLAIR9000 and FLAIR6000 at 3T with a 32-channel coil.

고자장 3T MRI 장비에서 동물영상을 위한 솔레노이드 RF코일 개발 (Development of Solenoid RF Coil for Animal Imaging in 3T High Magnetic Field MRI)

  • 이홍석;우동철;민광홍;김용권;이흥규;최보영
    • Investigative Magnetic Resonance Imaging
    • /
    • 제11권1호
    • /
    • pp.20-26
    • /
    • 2007
  • 목적 : 본 연구는 3 T MRI 장비에 적합한 동물영상용 솔레노이드 (solenoid) 코일을 개발하고 최적화한 후, 실제 동물모델에 대한 영상을 획득하는 것을 목표로 수행되었다. 대상 및 방법 : 솔레노이드 코일은 반경 4 cm, 길이 10 cm의 아크릴 구조물에 너비 2 cm, 두께 0.05 cm, 길이 10 cm의 구리테잎으로 3번 감긴 형태로 제작하였고, 구리테잎을 감을 때는 실린더 축과 수직이 되도록 감았으며 테잎간의 간격은 2 cm로 하였다. 축전지(capacitor)는 2-100 pF사이의 용량을 이용하였고, 코일은 수신 전용으로서 디자인되었다. 결과 : 개발된 솔레노이드 코일의 신호대 잡음비 (Signal to Noise Ratio; SNR)는 CuSO4수용액 팬텀(CuSO4; 0.7 g/L)에서 985, 쥐 (rat)를 이용한 동물실험에서 995이었고, Qfactor는 unload된 경우 203-206, load된 경우 84-89정도로 측정되었다. 솔레노이드 코일을 이용하여 획득한 영상은 상대적으로 해상도 (resolution)가 높았으며, 코일 시뮬레이션(simulation)을 통해서 얻은 RF field의 균질성 (homogeneity) 또한 매우 우수하였다. 결론 : 본 연구를 통하여 고자장 3T MRI 장비에서 쥐와 같은 작은 동물의 영상을 획득할 때 솔레노이드 코일을 사용하면 보다 향상된 영상의 대조도, 해상도, 선명도를 얻을 수 있는 가능성을 확인 할 수 있었다.

  • PDF

Cell Balancing Method in Flyback Converter without Cell Selection Switch of Multi-Winding Transformer

  • Kim, Jin-Woong;Ha, Jung-Ik
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권2호
    • /
    • pp.367-376
    • /
    • 2016
  • This paper presents a cell balancing method for a single switch flyback converter with a multi-winding transformer. The conventional method using a flyback converter with a multi-winding transformer is simple and easy to control, but the voltage of each secondary winding coil might be non-uniform because of the unequal effective turn-ratio. In particular, it is difficult to control the non-uniform effect using turn-ratios because secondary coil has a limited number of turns. The non-uniform secondary voltages disturb the cell balancing procedure and induce an unbalance in cell voltages. Individual cell control by adding a switch for each cell can reduce the undesirable effect. However, the circuit becomes bulky, resulting in additional loss. The proposed method here uses the conventional flyback converter with an adjustment made to the output filters of the cells, instead of the additional switch. The magnitude of voltage applied to a particular cell can be reduced or increased according to the adjusted filter and the selected switching frequency. An analysis of the conventional converter configuration and the filter design method reveals the possibility of adequate cell balancing control without any additional switch on the secondary side.

2극 초전도 동기기 설계법 고찰 (Design Considerations of 2-pole Synchronous Superconducting Rotating Machine)

  • 백승규;손명환;이언용;권영길;류강식;조영식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 B
    • /
    • pp.865-867
    • /
    • 2001
  • Generally large synchronous rotating machines with 2 poles have more merits than the others with more than 2 poles Superconducting synchronous rotating machines also have the same tendency, but they have different structure from conventional ones because of no magnetic core inside of the rotor. As the result, design approaches of the superconducting field coils are also different, which would be classified into 2 types according to their coil shapes. The first one is race-track type and the other is saddle type Race-track type machines have almost the same structure with conventional salient pole generators which are being used as largely small scale machines with more than 2 poles. On the other hand saddle type machines correspond to conventional cylindrical generators with 2 poles used for large turbine system in power plants. In this paper several types of superconducting field coils are introduced for 2 pole superconducting machine design and then the feasibility of each type is considered. Moreover, based on the consideration. 1MVA superconducting generator(S.G.) with saddle type field coil is designed electromagnetically.

  • PDF

엔코더리스 마그넷 모션을 이용한 위치제어에 대한 리니어모터 실험적 연구 (Experimental Study on Position Control System Using Encoderless Magnetic Motion)

  • 김홍윤;윤영민;심호근;권영목;허훈
    • 대한기계학회논문집A
    • /
    • 제40권1호
    • /
    • pp.9-16
    • /
    • 2016
  • 영구자석 선형 동기전동기(PMLSM : Permanent Magnet Linear Synchronous Motor)의 구조에서, 영구자석이 레일에 고정되고 코일이 움직이는 기존 영구자석 선형 동기전동기와 달리(영구자석 = 고정자, 코일 = 이동자), 코일이 고정되고, 영구자석을 움직이는(영구자석 = 이동자, 코일 = 고정자) 구조의 위치제어시스템을 제안하고자 한다. 위치 측정은 2개의 홀센서를 사용한다. 이 방식은 엔코더 출력 펄스 신호 대신에 2개의 홀센서에서 발생되는 구형파 신호를 4체배하여 이동자의 속도와 위치를 추정한다. 구형파를 발생시키는 2개의 홀센서로 PMLSM의 벡터제어를 구현하였을 때 정격속도 범위 내에서 안정적이고 효율적으로 제어되는 것을 시뮬레이션을 통하여 입증하였다. 또 하드웨어 실험으로 시스템의 위치제어성능은 $30{\sim}50{\mu}m$의 측정범위 내에서 $10{\sim}20{\mu}m$의 정밀도로 기존시스템보다 2배나 개선되며, 경제적 효율성과 제안된 위치제어 개념의 실용적인 유용성도 확인하였다. 2개의 홀센서를 이용한 벡터제어는 협소한 공간에도 취부 할 수 있으므로 엔코더나 레졸버의 장착이 어려운 시스템에 적용될 수 있다.

수치해석을 통한 유도가열 코일의 설계 및 설계인자의 민감도 해석 (Design and Sensitivity Analysis of Design Factors for Induction Heating System)

  • 오동욱;김태훈;도규형;박장민;이정호
    • 열처리공학회지
    • /
    • 제26권5호
    • /
    • pp.233-240
    • /
    • 2013
  • Rapid and homogeneous heating in heat treatment has been a challenging engineering issue throughout a heating temperature over $1,000^{\circ}C$. Induction heating has been widely used in field of heat treatment compared with conventional heating system. Advantages in homogeneous heating, simple fabrication, and repeatable use can be efficiently made with the induction heater. In this paper, numerical analysis of an induction coil system for heat flux gauge heating is performed. The effect of configuration on the heating performance was considered in various cases of the coil radius, distance between the winding, relative height difference between the heat flux gauge and the coil, and the applied current frequency. Temperature distribution within the heat flux gauge at frequency-steady state was calculated with a finite element method. Sensitivity analysis was also performed and the relative importance of 2 key parameters; coil radius, distance between the winding, were taken as main contributors for induction heating.

Parallel-loop 검출코일을 가지는 단일층 YBCO dc-SQUID 자력계의 제작 및 특성 연구 (Fabrications and measurements of single layer YBCO dc-SQUID magnetometers designed with parallel-loop pickup coil)

  • 유권규;김인선;박용기
    • Progress in Superconductivity
    • /
    • 제5권1호
    • /
    • pp.45-49
    • /
    • 2003
  • We have designed and fabricated the single-layer high $T_{c}$ SQUID magnetometer consisting of a directly coupled grain boundary junction SQUID with an inductance of 100 pH and 16 nested parallel pickup coils with the outermost dimension of 8.8 mm ${\times}$ 8.8 mm. The magnetometer was formed from a YBCO thin film deposited on an STO(100) bicrystal substrate with a misorientation angle of $30^{\circ}$. The SQUID magnetometer was further improved by optimizing the multi-loop pickup coil design for use in unshielded environments. Typical characteristics of the dc SQUID magnetometer had a modulation voltage of 40 $\mu\textrm{V}$ and a white noise of $30fT/Hz^{1}$2/. The SQUID magnetometer exhibited a 1/f noise level at 10 Hz reduced by a factor of about 3 compared with that of the conventional solid type pickup coil magnetometers and a very stable flux locked loop operation in magnetically disturbed environments.s.

  • PDF