• Title/Summary/Keyword: Conventional FR-4

Search Result 60, Processing Time 0.02 seconds

CLINICAL APPLICATION OF MODIFIED FR-4 (Modified FR-4의 임상적용례)

  • Song, Jae-Hyuk;Lee, Keung-Ho;Choi, Yeong-Chul
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.2
    • /
    • pp.323-328
    • /
    • 2001
  • Anterior open bite is one in which the teeth in the anterior portion of the maxilla and mandible are vertically apart and lack the overlapping necessary for the incisive function when the mandible is in closed position. Anterior open bite is a result of the interaction of many different etiologic factors including thumb and finger sucking, lip and tongue habits, airway obstruction, skeletal growth abnormalities and its tendency may appear with any type of skeletal patterns, such as Class I, II or III malocclusion types. Though the treatment methods for anterior open bite are various, the conventional FR-4, designed by Rolf Fr$\"{a}$nkel, is known to be effective in treating open bite cases with Class I or II skeletal patterns. It is due to that an incidence of skeletal Class II is high in the Occidentals, and open bite is accompanied by these malocclusion type in many cases. However, an incidence of skeletal Class III is high in the Orientals, and open bite is sometimes accompanied by skeletal Class III in many cases. Although the use of the conventional FR-4 was effective in the treatment of open bite, skeletal Class III would be worsened. So, a modified FR-4(placing the labial bow in the lower, the labial pads in the upper) was designed for the treatment of patients showing skeletal Class III and open bite.

  • PDF

Fresh and hardened properties of rubberized concrete using fine rubber and silpozz

  • Padhi, S.;Panda, K.C.
    • Advances in concrete construction
    • /
    • v.4 no.1
    • /
    • pp.49-69
    • /
    • 2016
  • This work investigates the mechanical properties of conventional concrete (CC) and self compacting concrete (SCC) using fine rubber and silpozz were accompanied by a comparative study between conventional rubberized concrete (CRC) and self compacting rubberized concrete (SCRC). Fine rubber (FR) from scrap tires has replaced the fine aggregate (FA) and Silpozz has been used as a replacement of cement at the proportions of 5, 10 and 15%. Silpozz as a partial replacement of cement in addition of superplasticiser (SP) increases the strength of concrete. Fresh concrete properties such as slump test, compaction factor test for CRC, whereas for SCRC slump flow, $T_{500}$, V-funnel, L-box, U-box, J-ring tests were conducted along with the hardened properties tests like compressive, split tensile and flexural strength test at 7, 28 and 90 days of curing. The durability and microstructural behavior for both CRC and SCRC were investigated. FR used in the present study is 4.75 mm passing with fineness modulus 4.74.M30 grade concrete is used with a mix proportion of 1:1.44:2.91 and w/c ratio as 0.43. The results indicate that as FR quantity increases, workability of both CRC and SCRC decreases. The results also show that the replacement of natural fine aggregate (NFA) with FR particles decreases the compressive strength with the increase of flexural strength observed upto 5% replacement of FR. Also replacement of cement with silpozz resulted enhancement of strength in SCRC.

Clinical Efficacy of 7-French Catheter for Initial Treatment of Primary Spontaneous Pneumothorax (원발성 자연기흉에 대한 초 치료로서 7-French 흉관의 적용)

  • Ryu Kyoung-Min;Jung Eui-Seok;Cho Suk-Ki;Sung Sook-Whan;Jheon Sang-Hoon
    • Journal of Chest Surgery
    • /
    • v.39 no.5 s.262
    • /
    • pp.394-398
    • /
    • 2006
  • Background: Goal of the initial treatment of primary spontaneous pneumothorax is re-expansion of the lung by evacuation of air from pleural space. Authors thought small caliber catheter could reach to this goal instead of conventional large bore chest tube. This retrospective study was undertaken to assess the effectiveness of 7-French (Fr) catheter for the initial treatment of primary spontaneous pneumothorax. Material and Method: Between May 2003 and April 2005, 111 patients with primary spontaneous pneumothorax were managed with tube drainage; 7 Fr catheter for 86 patients and 24-French chest tube for 25 patients. We analyzed catheter indwelling time, use of analgesics, re-expansion of the lung, and catheter related problems by medical records. Result: Mean catheter indwelling time was $2.4{\pm}1.1$ days in 7 Fr group and $2.3{\pm}1.3$ days in chest tube group (p>0.05). All patients with 24 Fr catheter needed analgesics injection but never in 7Fr group. Complete re-expansion of the lung based on plane chest radiograph was obtained in 77% of 7 Fr group. The problem related with 7 Fr catheter was kinking, which showed in 5.6%. Conclusion: Application of the 7 Fr catheter for initial management of primary spontaneous pneumothorax was as effective as 24 Fr catheter.

An Efficient Method to Compute Partial Atomic Charges of Large Molecules Using Reassociation of Fragments

  • Lee, Jung-Goo;Jeong, Ho-Young;Lee, Ho-Sull
    • Bulletin of the Korean Chemical Society
    • /
    • v.24 no.3
    • /
    • pp.369-376
    • /
    • 2003
  • Coulson (ZINDO), Mulliken $(MP2/6-31G^*)$ and Natural $(MP2/6-31G^*)$ population analyses of several large molecules were performed by the Fragment Reassociation (FR) method. The agreement between the conventional ZINDO (or conventional MP2) and FR-ZINDO (or FR-MP2) charges of these molecules was excellent. The standard deviations of the FR-ZINDO net atomic charges from the conventional ZINDO net atomic charges were 0.0008 for $C_{10}H_{22}$ (32 atoms), 0.0012 for $NH_2-C_{16}O_2H_{28}-COOH$ (53 atoms), 0.0014 for $NH_3^+-C_{16}O_2H_{28}-COOH$ (54 atoms), 0.0017 for $NH_2-C_{16}O_2H_{28}-COO^-$ (52 atoms), 0.0019 for $NH_3^+-C_{16}O_2H_{28}-COO^-$ (53 atoms), 0.0024 for a conjugated model $(O=CH-(CH=CH)_{15}-C=O-(CH=CH)_{12}-CH=CH_2)$, 118 atoms), 0.0038 for aglycoristocetin $(C_{60}N_7O_{19}H_{52}^+$, 138 atoms), 0.0023 for a polypropylene model complexed with a zirconocene catalyst $(C_{68}H-{121}Zr^+$, 190 atoms) and 0.0013 for magainin $(C_{112}N_{29}O_{28}SH_{177}$, 347 atoms), respectively. The standard deviations of the FR-MP2 Mulliken (or Natural) partial atomic charges from the conventional ones were 0.0016 (or 0.0016) for $C_{10}H_{22}$, 0.0019 (or 0.0018) for $NH_2-C_{16}O_2H_{28}-COOH$ and 0.0033 (or 0.0023) for $NH_3^+-C_{16}O_2H_{28}-COO^-$, respectively. These errors were attributed to the shape of molecules, the choice of fragments and the degree of ionic characters of molecules as well as the choice of methods. The CPU time of aglycoristocetin, conjugated model, polypropylene model complexed with zirconocene and magainin computed by the FR-ZINDO method was respectively 2, 4, 6 and 21 times faster than that by the normal ZINDO method. The CPU time of $NH_2-C_{16}O_2H_{28}-COOH\;and\;NH_3^+-C_{16}O_2H_{28}-COO^-$ computed by the FR-MP2 method was, respectively, 6 and 20 times faster than that by the normal MP2 method. The largest molecule calculated by the FR-ZINDO method was B-DNA (766 atoms). These results will enable us to compute atomic charges of huge molecules near future.

CLINICAL STUDY ON THE PAIN RESPONSE TO FR AFTER VITAL PULPOTOMY (FR을 이용(使用)한 생활치수절술후(生活齒髓切齒術後)의 치유결과(治癒結果)에 대(對)한 임상적(臨床的) 연구(硏究))

  • Yoon, Soo-Han
    • Restorative Dentistry and Endodontics
    • /
    • v.10 no.1
    • /
    • pp.187-191
    • /
    • 1984
  • Vital pulpotomies by conventional method were done in 120 male and female cases between the ages of 20 and 60 who visited to SNUDH. The pulpotomized surfaces were covered by FR paste and clinical symptoms were carefully examined 1 week and 4 weeks later. The results were as follows; 1. There was no distinct difference between male and female as a whole, and pain to cold and hot or percussion was increased by aging. 2. Incidence of pain to cold and hot or percussion in group examined 4 weeks later was slightly increased than in group examined 1 week later. 3. There was no case of pain to cold and hot or percussion over all ages after 1 week, but were 5 cases (male 2, female 3) in 40 age, and were 3 cases (male 1, female 2) in 50 age after 4 weeks. 4. In 20 and 30 age, there was no case of pain to cold and hot or percussion after 4 weeks, also.

  • PDF

A Study on Heat Transfer Characteristics of PCBs with a Carbon CCL (카본 CCL에 의한 PCB의 열전달 특성 연구)

  • Cho, Seunghyun;Jang, Junyoung;Kim, Jeong-Cheol;Kang, Suk Won;Seong, Il;Bae, Kyung Yun
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.22 no.4
    • /
    • pp.37-46
    • /
    • 2015
  • In this paper, the heat transfer characteristics of PCB (Printed Circuit Board) with cabon CCL (Copper Claded Layer) were studied through experiments and numerical analysis to compare of PCBs with conventional the FR-4 core and heavy copper cores. For study, samples are producted with HDI (High Density Interconnection) PCB of mobile phone with variations of thickness of core materials and grades of carbon material to evaluate heat transfer characteristics respectively. From this research results, heat transfer characteristics of the carbon core was rather low than heavy copper, but better than FR-4 core. In addition, even though the carbon and heavy copper core contributed on the heat transfer characteristics as their thickness increases, FR-4 cores disturbed heat transfer characteristics as it's thickness increases. Therefore, carbon core is recommendable to improve the heat transfer characteristics of the PCB because heavy copper core has much disadvantages such as increasing of wear of drill, the weight of PCB, and manufacturing cost by additional insulation materials for electrical insulation.

A Study on Thermal Behavior and Reliability Characteristics of PCBs with a Carbon CCL (카본 CCL이 적용된 PCB의 열거동 및 신뢰성 특성 연구)

  • Cho, Seunghyun;Kim, Jeong-Cheol;Kang, Suk Won;Seong, Il;Bae, Kyung Yun
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.22 no.4
    • /
    • pp.47-56
    • /
    • 2015
  • In this paper, the Thermal behavior and reliability characteristics of carbon CCL (Copper Claded Layer), which can be used as the core of HDI (High Density Interconnection) PCB (Printed Circuit Board) are evaluated through experiments and numerical analysis using CAE (Computer Aided Engineering) software. For the characterization of the carbon CCL, it is compared with the conventional FR-4 core and Heavy Cu core. From research results, the deformation amount of the flexure strength of PCB is the highest with pitch grade carbon and thermal behavior of PCB is lowest as temperature increases. In addition, TC (Thermal Cycling), LLTS (Liquid-to-Liquid Thermal Shock) and Humidity tests have been applied in the PCB with carbon core and the reliability of PCB with carbon core is confirmed through reliability tests. Also, possibility of uneven surface of the via hole and wear of the drill bit due to the carbon fibers are analyzed. surface of the via hole is uniform, the surface of the drill bit is smooth. Therefore, it is proved that the carbon CCL has the drilling workability of the same level as conventional core material.

MASS ESTIMATION OF IMPACTING OBJECTS AGAINST A STRUCTURE USING AN ARTIFICIAL NEURAL NETWORK WITHOUT CONSIDERATION OF BACKGROUND NOISE

  • Shin, Sung-Hwan;Park, Jin-Ho;Yoon, Doo-Byung;Choi, Young-Chul
    • Nuclear Engineering and Technology
    • /
    • v.43 no.4
    • /
    • pp.343-354
    • /
    • 2011
  • It is critically important to identify unexpected loose parts in a nuclear reactor pressure vessel, since they may collide with and cause damage to internal structures. Mass estimation can provide key information regarding the kind as well as the location of loose parts. This study proposes a mass estimation method based on an artificial neural network (ANN), which can overcome several unresolved issues involved in other conventional methods. In the ANN model, input parameters are the discrete cosine transform (DCT) coefficients of the auto-power spectrum density (APSD) of the measured impact acceleration signal. The performance of the proposed method is then evaluated through application to a large-sized plate and a 1/8-scaled mockup of a reactor pressure vessel. The results are compared with those obtained using a conventional method, the frequency ratio (FR) method. It is shown that the proposed method is capable of estimating the impact mass with 30% lower relative error than the FR method, thus improving the estimation performance.

Miniaturization of Circularly Polarized Microstrip Antenna for RFID Portable Reader at 900 MHz Band (900 MHz대 RFID 휴대 리더용 원편파 안테나 소형화)

  • Kang, Min-Sik;Choi, Ik-Guen
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.4
    • /
    • pp.411-417
    • /
    • 2008
  • This paper presents the miniaturization of circularly polarized microstrip patch antenna for UHF-band RFID portable reader. The proposed antenna has a group of four I-slots on a conventional corner-truncated square microstrip patch and it is shown that the antenna size is reduced compared to the antenna without I-slots. A 76 mm by 76 mm small antenna with four I-slots is fabricated with 6.4 mm thick FR4 substrate and its 10 dB return loss bandwidth, the gain and the axial ratio are measured to be $938{\sim}975\;MHz$, $-0.88{\sim}-2\;dBi$, and $3.27{\sim}13.21\;dB$ within the 10 dB return loss bandwidth, respectively.

Miniaturization of Branch Line Coupler with Connected Coupled Lines (연결된 결합 선로를 갖는 소형 브랜치 선로 결합기)

  • Rhee, Seung-Yeop
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.6
    • /
    • pp.598-604
    • /
    • 2011
  • A method of miniaturizing branch line coupler with connected coupled lines is presented. The quarter-wavelength transmission lines in the typical microstrip branch line coupler are replaced with the connected coupled lines with same characteristics of ones for compact size. The connected coupled line is analyzed by T-equivalent circuit and Z parameters based on the even-odd mode analysis. The proposed branch line couplers with connected coupled line are designed and fabricated on FR4 substrate at 2.4 GHz. The measured results show good agreement with theoretical prediction. And the experimental results show that the size of coupler is 37 precent smaller than conventional coupler. This minimized coupler is suitable for Butler Matrix as feeder for mobile communication beam forming antenna.