• Title/Summary/Keyword: Conventional Compression Processing

Search Result 130, Processing Time 0.026 seconds

OCCLUSION AND VERTICAL DIMENSION CHANGES ACCORDING TO DENTURE PROCESSING TECHNIQUES (총의치 온성방법에 따른 교합 및 수직 고경의 변화)

  • Kim, Mun-Young;Chung, Kwan-Ho;Yu, Hyoung-Woo;Ahn, Seung-Geun;Song, Kwang-Yeob;Park, Charn-Woon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.34 no.2
    • /
    • pp.277-289
    • /
    • 1996
  • The purpose of this study was to compare the amount of the vertical pin opening of dentures processed by the conventional compression method & the injection-processing method. The articulating ribbon and T-Scan system were used to determine the changes in tooth contacts and the correlation between the changes in tooth contacts and the amount of the vertical pin opening after processing was analyzed statistically. The obtained results were as follows. 1. The amounts of the vertical pin opening were 0.75mm, 0.31mm for conventional compression method and injection-pressing method, respectively. The difference between the two methods was highly significant on the basis of t test statistics(p<0.05). 2. The total number of contact points recorded by articulating ribbon after processing was decreased to 48%, 72%, of that before processing for conventional compression method and injection-pressing method, by T-Scan system, 39%, 53%, respectively. 3. The mean values for the number of contacts points per tooth recorded by articulating ribbon after processing were 1.6 for the second molar, 2.2 for the first moalr, 0.4 for the second premolar, 0.6 for the first premolar in conventional compression method, and 2, 3.2, 1.2, 0.8 in injection-pressing method. 4. The correlation between the reduction of contact points and the amount of the pin opening after processing was not significant. 5. The mean values for the number of contact points per tooth recorded by T-Scan system after processing were 1.25, 1.4, 0.7, and 0.55 at the second molar, the first molar, the second premolar, and the first premolar in conventional compression method, and 1.45, 2.1, 1.0, 0.75 in injection method, respectively. 6. The correlation between the number of contact points by using articulating ribbon and T-Scan system after processing was not significant in both methods.

  • PDF

Improvement of Image Sensor Performance through Implementation of JPEG2000 H/W for Optimal DWT Decomposition Level

  • Lee, Choel;Kim, BeomSu;Jeon, ByungKook
    • International journal of advanced smart convergence
    • /
    • v.6 no.1
    • /
    • pp.68-75
    • /
    • 2017
  • In this paper, a particular application of digital photos, remote sensing, remote shooting air moving, high-resolution and high compression of medical images required by remote shooting of JPEG2000 standard applied in the field of hardware design, production was implemented. JPEG2000 standard for image compression using the software implementation of the processing speed is very slow compared to conventional JPEG disadvantages, and also the standard of JPEG2000 DWT (Discrete wavelet transform) to improve the level of compression for image data if processing speed is a phenomenon that has degraded. In order to solve these JPEG2000 compression / decompression groups were designed and applied. In this paper, the optimal JPEG2000 compression / reservoir hardware by changing the level for still image compression, faster computation speed and quality has shown improvement.

DIMENSIONAL CHANGE AND FLEXURAL STRENGTH IN COMPLETE DENTURES FABRICATED BY INJECTION MOLDING AND CONVENTIONAL COMPRESSION PROCESSING (의치상용 레진의 전입 방법에 따른 중합체적변화와 굴곡강도에 관한 연구)

  • Choi Hoon-Dal;Kwon Kung-Rock;Kim Hyeong-Seob;Choi Dae-Gyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.4
    • /
    • pp.478-486
    • /
    • 2005
  • Statement of problem : Fracture and dimensional change of an acrylic resin denture are a rather common occurrence. Purpose : The purpose of this study was to compare differences in dimensional changes and flexural strength of separate maxillary complete dentures after immediate deflasking by injection molding and conventional compression processing. Material and method: To evaluate dimensional stability, the maxillary dentures were fabricated by using different materials and methods. Lucitone 199(Dentsply Trubyte. york, pennsylvania, USA) and Vertex(Dentimex, zeist, Netherlands) were used as materials. Compression and injection packing methods were used as processing methods. The impression surface of the dentures was measured by 3D Scann-ing System(PERCEPTRON USA) and overlapped original impression surface of the master cast. To evaluate flexural strength, resin specimens were made according to the different materials, powder/liquid ratio and processing methods. Flexural strength of the complete resin specimens (64mm$\times$10mm$\times$3.3mm) were measured by INSTRON 4467. (INSTRON, England) The data was analyzed by ANOVA, t-test and Tukey test. (p<.05 level of significance) Result: The results were as follows 1. There was no significant differences between master model and denture base for each group in overall dimensional changes. 2. Palatal area was more stable than flange or alveolar area in dimensional stability. but. there was no significant differences among each area. 3. Materials and power/liquid ratio had an effect on flexural strength. (P<.05) Especially materials was most effective. (P<.05) 4. Lucitone 199(powder/liquid ratio followed by manufacturer's direction) showed higher flexural strength than Vertex. Conclusion : Dimensional stability or flexural strength are affected by materials rather than packing techniques.

A Consistent Quality Bit Rate Control for the Line-Based Compression

  • Ham, Jung-Sik;Kim, Ho-Young;Lee, Seong-Won
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.5 no.5
    • /
    • pp.310-318
    • /
    • 2016
  • Emerging technologies such as the Internet of Things (IoT) and the Advanced Driver Assistant System (ADAS) often have image transmission functions with tough constraints, like low power and/or low delay, which require that they adopt line-based, low memory compression methods instead of existing frame-based image compression standards. Bit rate control in the conventional frame-based compression systems requires a lot of hardware resources when the scope of handled data falls at the frame level. On the other hand, attempts to reduce the heavy hardware resource requirement by focusing on line-level processing yield uneven image quality through the frame. In this paper, we propose a bit rate control that maintains consistency in image quality through the frame and improves the legibility of text regions. To find the line characteristics, the proposed bit rate control tests each line for ease of compression and the existence of text. Experiments on the proposed bit rate control show peak signal-to-noise ratios (PSNRs) similar to those of conventional bit rate controls, but with the use of significantly fewer hardware resources.

The Effect of Various Molding Methods for Precision Optical Products Using Birefringence Analysis (정밀 광학부품의 복굴절 분석을 통한 각종 성형법의 영향에 관한 연구)

  • Min, I.K.;Cho, S.W.;Yoon, K.H.
    • Transactions of Materials Processing
    • /
    • v.22 no.1
    • /
    • pp.48-53
    • /
    • 2013
  • As the adoption of injection molding technology increases, injected-molded optical products require higher dimensional accuracy and optical stability than ever before. In the present study, four kinds of molding methods, i.e., conventional injection molding (CIM), injection/compression molding (ICM), rapid heat and cooling the mold(RHCM) and rapid injection/compression molding (RICM) were selected in order to investigate the optical anisotropy of a 7 inch Light Guide Plate(LGP) by examining the gap-wise distribution of birefringence and the extinction angle. The results indicate that the compression process can decrease flow-induced birefringence over the whole region and that rapid heating can decrease the birefringence level better than conventional molding. In addition, for the combination of compression and rapid heating a reversal flow was detected from the distribution of the extinction angle near the gate.

Finite Element Analysis of Injection/Compression Molding Process (사출압축성형 공정에 대한 유한요소 해석)

  • 이호상
    • Transactions of Materials Processing
    • /
    • v.13 no.2
    • /
    • pp.180-187
    • /
    • 2004
  • A computer code was developed to simulate the filling stage of the injection/compression molding process by a finite element method. The constitutive equation used here was the compressible Leonov model. The PVT relationship was assumed to follow the Tait equation. The flow-induced birefringence was related to the calculated flow stresses through the linear stress-optical law. Simulations of a disk part under different process conditions including the variation of compression stroke and compression speed were carried out to understand their effects on birefringence variation. The simulated results were also compared with those by conventional injection molding.

TRIANGLE MESH COMPRESSION USING GEOMETRIC CONSTRAINTS

  • Sim, Jae-Young;Kim, Chang-Su;Lee, Sang-Uk
    • Proceedings of the IEEK Conference
    • /
    • 2000.07a
    • /
    • pp.462-465
    • /
    • 2000
  • It is important to compress three dimensional (3D) data efficiently, since 3D data are too large to store or transmit in general. In this paper, we propose a lossless compression algorithm of the 3D mesh connectivity, based on the vertex degree. Most techniques for the 3D mesh compression treat the connectivity and the geometric separately, but our approach attempts to exploit the geometric information for compressing the connectivity information. We use the geometric angle constraint of the vertex fanout pattern to predict the vertex degree, so the proposed algorithm yields higher compression efficiency than the conventional algorithms.

  • PDF

A Study on the Molding Characteristics of Injection Compression Molding Through Computer Simulation (컴퓨터 해석을 통한 사출압축성형의 성형특성에 관한 연구)

  • Chun, Y.H.;An, H.G.;Lyu, M.Y.
    • Elastomers and Composites
    • /
    • v.47 no.4
    • /
    • pp.341-346
    • /
    • 2012
  • Injection molding is one of the widely used polymer processing operations. It is being used for not only conventional injection molding but gas injection molding, water injection molding, and injection compression molding. Injection compression molding involves injection and compression operation, and it gives uniform physical property and high dimensional quality of product. In this study, injection compression characteristics for various product shapes have been investigated by computer simulation. Product containing side wall showed not much effective in injection compression molding since wall thickness direction was perpendicular to the compression direction. Uniform and low shrinkage was observed in injection compression molding comparing conventional injection molding. Subsequently injection compression molding can be used for molding precise product. Optimal injection compression molding condition was obtained using design of experiment for plastic lens and the results were compared with conventional injection molding.

Performance Evaluation of ECG Compression Algorithms using Classification of Signals based PQSRT Wave Features (PQRST파 특징 기반 신호의 분류를 이용한 심전도 압축 알고리즘 성능 평가)

  • Koo, Jung-Joo;Choi, Goang-Seog
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37 no.4C
    • /
    • pp.313-320
    • /
    • 2012
  • An ECG(Electrocardiogram) compression can increase the processing speed of system as well as reduce amount of signal transmission and data storage of long-term records. Whereas conventional performance evaluations of loss or lossless compression algorithms measure PRD(Percent RMS Difference) and CR(Compression Ratio) in the viewpoint of engineers, this paper focused on the performance evaluations of compression algorithms in the viewpoint of diagnostician who diagnosis ECG. Generally, for not effecting the diagnosis in the ECG compression, the position, length, amplitude and waveform of the restored signal of PQRST wave should not be damaged. AZTEC, a typical ECG compression algorithm, is validated its effectiveness in conventional performance evaluation. In this paper, we propose novel performance evaluation of AZTEC in the viewpoint of diagnostician.

Intra-picture Block-matching Method for Codebook-based Texture Compression

  • Cui, Li;Jang, Euee S.
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.10 no.10
    • /
    • pp.5063-5073
    • /
    • 2016
  • In this paper, an efficient texture compression method is proposed for fast rendering, which exploits the spatial correlation among blocks through intra-picture block matching. Texture mapping is widely used to enhance the visual quality of results in real-time rendering applications. For fast texture mapping, it is necessary to identify an effective trade-off between compression efficiency and computational complexity. The conventional compression methods utilized for image processing (e.g., JPEG) provide high compression efficiency while resulting in high complexity. Thus, low complexity methods, such as ETC1, are often used in real-time rendering applications. Although these methods can achieve low complexity, the compression efficiency is still lower than that of JPEG. To solve this problem, we propose a texture compression method by reducing the spatial redundancy between blocks in order to achieve the better compression performance than ETC1 while maintaining complexity that is lower than that of JPEG. Experimental results show that the proposed method achieves better compression efficiency than ETC1, and the decoding time is significantly reduced compared to JPEG while similar to ETC1.