• Title/Summary/Keyword: Conventinal smear

Search Result 2, Processing Time 0.016 seconds

Comparison of Liquid-based Cytology and Conventional Smear in the Evaluation of Sputum Cytology

  • Back, Oun-Cheol
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.45 no.1
    • /
    • pp.26-31
    • /
    • 2013
  • The cytology of sputum specimens, at a medical facility in Korea, is using the liquid-based cytology and conventional smear method. It confirms the diagnosis using conventional smear methods and the liquid-based cytology. In addition, the diagnosis uses two kinds of each method, compares the suitability, sensitivity and specificity for each test and tries to understand the efficient method needed. It divided sputum specimens in half and liquid-based cytology. A conventional smear method was conducted and the Papanicolaou's staining was conducted using Autostainer. Diagnosed each slide of staining produced smear slides specimens by using an optical microscope. The result of the liquid-based cytology and conventional smear method was that the liquid-based cytology was of a higher-grade than the conventional smear method. It was 36.8%, and 62.8% in the same condition. But only one case was of a lower grade. Liquid-based cytology showed 86.2% of adequacy, 31.0% of sensitivity and 97.5% of specificity. The conventional smear method showed 54.4% of adequacy, 19.6% of sensitivity and 100% of specificity. If it was conducted with two methods at the same time, the results would be similar to the liquid-based cytology. In conclusion, liquid-based cytology has a more superior adequacy and sensitivity than the conventional smear method. The combination of the two methods is similar to the result of only conducting a liquid-based cytology. Conducting a liquid-based cytology rather than the combination of the two ways of sputum cytoscopy, is to be considered as an efficient method to achieve diagnostic accuracy, reduce labor of clinical technologist and pathologist, and to reduce the expense of patients.

  • PDF

CUTTING EFFICACY OF Er:YAG LASER AND CONVENTIONAL BUR IN DECIDUOUS AND PERMANENT TEETH (Er:YAG laser와 Conventional bur의 유치와 영구치 치아삭제효과 비교)

  • Park, In-Cheon;Lee, Chang-Seop;Lee, Nan-Young;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.2
    • /
    • pp.272-285
    • /
    • 2003
  • This study was conducted to observe the microscopic structures of cavities formed after ablation of primary teeth, permanent teeth, enamel and dentin in using a bur and cavities formed after ablation using laser and the following results were obtained after comparing the effects of ablation. Using a #330 bur and Er:YAG laser irradiated at 150 mJ, 200 mJ, 250 mJ and 300 mJ all at the frequency of 5 Hz, 1 mm enamel and dentin samples were ablated and the ablation time was measured. In order to measure the surfaces ablated, 5 each of primary teeth and permanent teeth were ablated using a #330 bur and Er:YAG laser at 150 mJ, 200 mJ, 250 mJ and 300 mJ for 1 sec and the cross section and vertical section were observed. The following results were obtained : 1. Cutting time of Er:YAG laser was longer than that of conventinal high-speed bur regardless of teeth type. 2. Cutting on enamel, Cutting time of conventional high-speed bur in deciduous teeth was longer than in permanent teeth(P<0.05). But Er:YAG laser was not showed any difference between the deciduous and permanent teeth(P>0.05). 3. Cutting on dentin, Cutting time of conventional high-speed bur in permanent teeth was longer than deciduous teeth. Er:YAG laser of 150 mJ, 5 Hz in permanent teeth was longer than in deciduous teeth(p<0.05). But laser of other power did not showed mean difference. 4. The cavity surface treated with the convetional high-speed bur revealed a relatively flat appearance, almost covered with a debris-like smear layer. Cavity wall showed striped appearance because of blade of bur. 5. The cavity surface treated by the Er:YAG laser system was irregular or rough surface with the absence charring, carbonization, or cracking of the dentin. In addition, there was an absence of a smear layer. Cavity floor was round and relatively smooth. According to these results, cutting time of Er:YAG laser was almostly same in permanent and deciduous teeth, but more effective in dentin than enamel. Cutting the sample, Er:YAG laser was needed more time than conventional bur. But SEM findings suggested that laser device produced favorable surface characteristic(i.e, no smear layer, irregular surface, cracking).

  • PDF