• 제목/요약/키워드: Convective heat transfer coefficients

검색결과 124건 처리시간 0.025초

순수 및 혼합냉매의 원관내 증발열전달 실험 (Experimental study on convective boiling heat transfer for pure refrigerants and refrigerant mixtures in a horizontal tube)

  • 신지영;김민수
    • 대한기계학회논문집B
    • /
    • 제20권2호
    • /
    • pp.730-740
    • /
    • 1996
  • Boiling heat transfer coefficients of pure refrigerants (R22, R32, R134a, R125, R290, and R600a) and refrigerant mixtures (R32/Rl34a, R290/ R600a, and R32/R125) are measured experimentally and compared with Chen's correlation. The test section is a seamless stainless steel tube with inner diameter of 7.7mm and uniformly heated by applying electric current directly to the tube. Heat fluxes range from 10 to 30kW$^2$. Mass fluxes are set to 424 ~ 742kg/m$^{2}$s for R22, R32, R134a, R32/R134a, and R32/Rl25 ; 265 ~ 583kg/m$^{2}$s for R290, R600a, and R290/R600a. Heat transfer coefficients depend strongly on heat flux at a low quality region and become independent as quality increases. Convective boiling term in the Chen's correlation predicts experimental data of the pure refrigerants fairly well (relative error of 12.1% for the data of quality over 0.2). The correlation for pure substances overpredicts the heat transfer coefficients for nonazeotropic refrigerant mixtures.

비대칭 엇갈림 배열로 구성된 납작관-평판휜 형상의 밀집형 열교환기에 대한 대류열전달 특성 해석 (Analysis of Convective Heat Transfer Characteristics for the Compact Heat Exchanger with Flat Tubes and Plate Fins Having a Non-symmetric Staggered Arrangements)

  • 모정하;이상호
    • 대한기계학회논문집B
    • /
    • 제33권5호
    • /
    • pp.318-325
    • /
    • 2009
  • Numerical analysis has been carried out to investigate air-side convective heat transfer characteristics in compact heat exchanger with flat tubes and continuous plate fins having a symmetric and non-symm etric staggered arrangements. Simulation results such as air velocity and temperature distributions are presented, and heat transfer coefficients are compared with previous experimental results. In order to investigate the flow and heat transfer features by periodic boundary conditions, the three blocks were used. Predicted heat transfer coefficients between the three blocks are similar while there are relatively differences, compared with the experimental data. From the calculated results a correlation for Colburn j factor in the compact heat exchanger system is suggested. The predicted results in this study can be applied to the optimal design of air conditioning system.

마이크로관 내 증발열전달에 관한 연구 (A Study on the Evaporative Heat Transfer in Microtubes)

  • 황윤욱;김주혁;김민수
    • 설비공학논문집
    • /
    • 제17권12호
    • /
    • pp.1113-1122
    • /
    • 2005
  • The experimental heat transfer coefficients have been measured for two-phase convective boiling in two circular microtubes with inner diameters of $430{\mu}m\;and\;792{\mu}m$. While the heat transfer was greatly affected by the heat flux in the low quality region, the mass flux played a role in the high quality region. The smaller microtube had greater heat transfer coefficients. When the heat flux is varied from $20kW/m^2\;to\;30kW/m^2\;at\;G=240kg/m^2s$, the difference between the average heat transfer coefficients of the test tube $A(D_i=430{\mu}m)$ and the test tube $B(D_i=792{\mu}m)$ changes from $32.5\%\;to\;52.1\%$. At $G=370kg/m2^s$, the difference between the average heat transfer coefficients changes from $47.0\%\;to\;53.8\%$. A new correlation for the evaporative heat transfer coefficients in microtubes was developed by considering the following factors; the laminar flow heat transfer coefficient of liquid-phase flow, the enhancement factor of the convective heat transfer, and the nucleate boiling correction factor. The correlation developed in this study predicts the experimental heat transfer coefficients within an absolute average deviation of $8.4\%$.

종횡비에 따른 납작관-평판휜 형상의 밀집형 열교환기 내공기 측 대류열전달특성에 대한 수치해석 (Numerical Analysis for the Air-Side Convective Heat Transfer Characteristics in a Compact Heat Exchanger with Flat Tubes and Plate Fins According to the Aspect Ratio)

  • 모정하
    • 대한기계학회논문집B
    • /
    • 제32권9호
    • /
    • pp.695-703
    • /
    • 2008
  • Numerical analysis has been carried out to investigate air-side convective heat transfer characteristics in a compact heat exchanger with flat tubes and continuous plate fins according to the aspect ratio. RNG k-$\varepsilon$ model is applied for turbulence analysis. Simulation results such as air velocity and temperature distributions are presented, and heat transfer coefficients are compared with previous correlations for circular tubes. The numerical conditions are considered for the aspect ratios ranging from 3.06 to 5.44 and Reynolds number ranging from 1000 to 10,000. The results showed that heat transfer coefficients decreased with the increase of aspect ratio. From the calculated results a correlation of Colburn j factor for the considered aspect ratio in the compact heat exchanger system is suggested. The predicted results in this study can be applied to the optimal design of air conditioning system.

튜브배열 방향과 수직한 유동에 의한 관외 대류 열전달 (The Convective Heat Transfer for the Flow Perpendicular to the Tube Array)

  • 전용한;김종윤;김남진;김종보
    • 설비공학논문집
    • /
    • 제18권8호
    • /
    • pp.656-663
    • /
    • 2006
  • The convective heat transfer on the outer surface of tube arrays perpendicular to the flow direction was experimentally investigated. The test sections which include the aligned and staggered arrangements were made and the local heat transfer coefficients on the outer surface of the tube were measured after the flow has been fully developed. The results showed that the local heat transfer coefficients of the staggered arrangement, which has transverse pitch of 0.075 m and longitudinal pitch of 0.08 m, were about 15% greater than that of the aligned arrangement. Also, the overall mean Nusselt number of the former was greater than that of the latter. It is verified that the results obtained by using the simulation show the same tendency with those of experiment.

온실 스크린의 대류열전달계수 측정 (Measurement of Convective Heat Transfer Coefficients of Horizontal Thermal Screens under Natural Conditions)

  • 라피크아딜;나욱호;라쉬드아드난;김현태;이현우
    • 생물환경조절학회지
    • /
    • 제29권1호
    • /
    • pp.9-19
    • /
    • 2020
  • 대류열전달은 겨울철 온실 열손실의 중요한 원인이 되며, 일반적으로 복사열에 의한 손실보다 더 크다. 스크린의 대류열전달계수를 자연상태에서 측정한 연구가 수행된 바는 있지만 상하면의 재질이 동일하고 공극이 없는 스크린에 대해서는 적용을 할 수 없는 방법이다. 이러한 재질의 스크린은 한국에서 많이 사용되고 있으나 대류열전달 특성을 파악하는데 많은 어려움이 있는 실정이다. 본 연구에서는 공극이 없는 3가지 종류의 스크린에 대해 대류열전달계수를 구하였으며, 계수를 산정하기 위하여 복사열수지 이론에 근거하여 산정방법을 개발하였다. 실험장치에 스크린을 설치하고 일사량, 장파복사량, 대기온도, 스크린 및 흑색천의 표면온도, 풍속 등을 측정하였다. 스크린의 표면온도와 주변온도의 차이에 따른 대류열전달계수를 산정하였다. 풍속이 거의 없는 상태에서 온도의 차이가 증가함에 따라 계수는 감소하는 것으로 나타났다.

유한요소해석을 이용한 탄소강의 담금질 공정에 대한 상변태 및 기계적 성질 예측 (Prediction of Phase Transformation and Mechanical Property of Carbon Steel in Quenching based on Finite Element Analysis)

  • 김동규;정경환;강성훈;임용택
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2009년도 추계학술대회 논문집
    • /
    • pp.173-176
    • /
    • 2009
  • A great emphasis has been placed on the design of heat treatment process to achieve desired microstructure and mechanical property of final product. In this study, finite element analysis was carried out to predict temperature, microstructure and hardness of eutectoid steel after water quenching. Convective heat transfer coefficients were determined by inverse analysis using surface temperatures measured with three different installation methods of thermocouples. Finally, the effect of convective heat transfer coefficients on the prediction of temperature history and hardness was analyzed by comparing experimental and simulation results.

  • PDF

벽면에 충돌하는 슬롯형 제트와 원형 제트의 열전달 효과 비교 (Heat Transfer Characteristics of a Slot Jet and Circular Jets Impinging on a Flat Surface)

  • 김희현;김대성;윤순현
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.540-545
    • /
    • 2001
  • An experimental study was conducted to compare the heat transfer characteristics of an impinging slot jet and three kinds of impinging circular jets. Thermochromic liquid crystal with an image processing system was employed to measure the temperature of impinging wall where constant heat flux condition was applied. The distribution of convective heat transfer coefficients were then evaluated for eight nozzle-to-surface distance settings for each jet cases. The cooling effect was linearly proportional to the number of nozzles for circular jet cases at the same nozzle exit speed. However, the heat transfer under constant volume flow rate was the most at single circular jet. It was concluded that the overall convective heat transfer was better at the circular jets than the slot jet.

  • PDF

등온으로 유지되는 가는 열선주위를 흐르는 나노유체의 대류열전달계수 측정실험 (Measuring Convective Heat Transfer Coefficients of Nanofluids over a Circular Fine Wire Maintaining a Constant Temperature)

  • 이신표
    • 대한기계학회논문집B
    • /
    • 제36권1호
    • /
    • pp.9-16
    • /
    • 2012
  • 본 논문은 열전달 유체로서 나노유체의 유용성을 평가하기 위한 장치를 설명한 것이다. 열선센서를 이용한 나노유체 대류성능 평가장치는 몇 가지가 제안되었으나 센서의 작동조건이 불명확한 단점이 있었다. 본 연구에서는 일정한 온도로 유지되는 가는 열선 주위를 흐르는 대류열전달계수를 측정하여 나노유체의 유용성을 평가하였다. 제시된 장치의 동작원리와 실험방법을 자세히 설명하였으며 먼저 순수유체에 대한 실험을 통하여 장치의 타당성을 검증하였다. 그래파이트 나노오일을 이용하여 대류열전달계수에 미치는 농도와 속도 그리고 온도의 영향을 종합적으로 고찰하였다.

이중 충돌 제트를 갖는 내부 유로의 열전달 계수 측정 (Measurement of Heat Transfer Coefficient in a Duct with Double Imingement Jets)

  • 곽재수
    • 한국항공운항학회지
    • /
    • 제14권1호
    • /
    • pp.9-14
    • /
    • 2006
  • Averaged heat transfer coefficients in the trailing edge model of a turbine blade with double impingements were measured using transient liquid crystals technique and conventional copper plate-thermocouple technique. The detailed distributions of heat transfer coefficients by transient liquid crystals technique were also presented. Results showed that increased heat transfer coefficient due to the inpingements and the averaged heat transfer coefficients increased as Reynolds number increased. Results by transient liquid crystals technique showed that the heat transfer coefficient strongly depended on the main stream temperature used in heat transfer coefficient calculation. The averaged heat transfer coefficients measured by different methods showed similar trend as Reynolds number changed, but the value varied up to 40% depending on the measurement technique.

  • PDF