• 제목/요약/키워드: Convection coefficient

검색결과 254건 처리시간 0.027초

열 등가회로를 이용한 SPMSM 전동기의 온도 예측 (Prediction of temperature using equivalent thermal network in SPMSM)

  • 김도진;권순오;정재우;홍정표
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.792-793
    • /
    • 2008
  • This paper deals with the temperature calculation using equivalent thermal network for surface mounted permanent magnet synchronous motor(SPMSM) under the steady-state condition. In the equivalent thermal network, heat sources are generated from copper loss and iron loss. Heat transfer consists of conduction, convection and radiation. However, radiation is neglected in this paper because its effect is much smaller than others. Although the heat transfer coefficient in conduction use material property, heat transfer coefficient in convection is difficult to measure due to the atmosphere and ambient condition. Temperatures of each region in SPMSM are measured by thermocouple in operating condition and the thermal resistances of convection are calculated by kirchhoff's current law(KCL) and experimental result. In order to verify the validation and reliability of the proposed equivalent thermal network, temperature which is calculated other load condition is compared with experimental results. Accordingly, temperatures of each region in other SPMSMs will be easily predicted by the proposed equivalent thermal network.

  • PDF

강제대류시 계절에 따른 KURT 내 열전달계수 결정에 관한 연구 (A Study on the Determination of the Seasonal Heat Transfer Coefficient in KURT Under Forced Convection)

  • 윤찬훈;권상기;황인필;김진
    • 방사성폐기물학회지
    • /
    • 제8권3호
    • /
    • pp.189-199
    • /
    • 2010
  • 고준위 방사성 폐기물 처분장의 경우 폐기물의 방사성 붕괴에 의해 열이 발생되며, 암반을 통한 열전달에 의해 처분장 주변 환경이 변화됨으로써 처분장의 안전성에 영향을 미칠 수 있다. 그러므로 지하 처분장 대기의 열전달계수를 결정하는 것은 매우 중요하다. 이에 본 연구에서는 Korea Atomic Energy Research Institute Underground Research Tunnel (KURT)에서 내부 환경 인자들의 측정을 통해 강제대류시 열전달계수를 산정하였다. 실험을 위해 KURT 내 히터구간의 막장 벽면에는 길이 2 m, 용량 5 kw의 히터를 삽입하여 암반 내부를 $90^{\circ}C$로 가열하였고, 외부와 연결된 급기용 팬에 의해 신선한 공기를 공급하였다. 연구결과, 외부공기 공급 후 히터구간 대기의 기류속도는 평균 0.81 m/s로 측정되었고 레이놀즈수는 약 310,000~340,000의 값을 나타냈다. 그리고 강제대류조건에서 히터구간 내 계절별 열전달계수는 각각 여름철 $7.68\;W/m^2{\cdot}K$와 겨울철 $7.24\;W/m^2{\cdot}K$의 수치를 나타냈다.

고속전철 와전류 제동장치의 온도 특성해석 및 실험 (Thermal Analysis and Test of Eddy-Current Braker for High-Speed Train)

  • 정수진;강도현;구대현;김동희;방덕제
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제52권5호
    • /
    • pp.197-202
    • /
    • 2003
  • When a high-speed train reduces its operating velocity while decelerating from a maximum of 350 to 50 [km/h], the train applies eddy-current brakes, which results in a deceleration time of approximately 3minutes. Therefore, a high current is utilized in order to obtain a large braking force. Consequently, the temperature of the electromagnet and rail increases significantly. In this paper, The thermal characteristics on a single magnet pole with convection heat transfer coefficient are simulated by using 2D-FEM. To verify the analysis results, the computed temperatures are compared with the experimentally measured temperature at stationary state. Furthermore, transient-state thermal analysis is performed to predict the magnet temperatures as the train is decelerating.

유한 요소 해석을 활용한 공작기계 이송축 열적 특성 평가 (Evaluation of Thermal Characteristics for a Feeding Axis of Machine Tools Using Finite Element Analysis)

  • 이창훈;최진우
    • 한국생산제조학회지
    • /
    • 제22권3호
    • /
    • pp.380-387
    • /
    • 2013
  • In this study, two finite element (FE) models were developed to evaluate the thermal characteristics of a feeding axis of a CNC lathe. One was used for analysis of heat transfer to identify the temperature distribution of the feeding axis and then, the other was used for analysis of thermal deformation to evaluate its structural behavior based on the temperature distribution. The FE models were based on the test standard for the axial thermal displacement. The feeding velocity was composed of three steps: the ascending, constant, and descending velocities. Therefore, the heat generation and convection coefficient were calculated for each velocity and applied to the thermal FE model. The convection coefficient for the ball screw rotation was based on an experimental equation. The result of the analytical thermal displacement was compared with that of the experimental displacement to verify the finite element models.

용접코팅된 연속주조 몰드의 열해석 (Thermal Analysis of Continuous Casting Welding-Coated Mold)

  • 이종선;김세환
    • 한국산학기술학회논문지
    • /
    • 제2권1호
    • /
    • pp.7-12
    • /
    • 2001
  • 본 연구에서는 제철소에서 활발히 사용되고 있는 연속주조 몰드에 대하여 용접코팅을 실시한 후 주조시 열적거동을 규명하는 열해석을 수행하였다. 열해석을 수행하기 위하여 상용 유한요소해석 코드인 ANSYS를 활용하였으며 주조속도, 냉각조건, 막 열전도계수, 대류열복사, 하중조건 등을 고려하여 몰드 표면의 온도분포를 구하였다.

  • PDF

초기재령 콘크리트의 외기대류계수에 관한 연구 (A Study on the Convection Heat Transfer Coefficient in Concrete at Early Ages)

  • 김진근;전상은;양은익;송영철;방기성
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1997년도 가을 학술발표회 논문집
    • /
    • pp.151-156
    • /
    • 1997
  • The setting and hardening of concrete is accompanied by nonlinear temperature distribution caused by developing heat of cement hydration. expecially at early ages, nonlinear temperature distribution has a large influence n the crack evaluation. So the need to predict the exact temperature history in concrete has led to the examination thermal properties. In this study, the convection heat transfer coefficient is experimentally investigated which is one of the thermal properties in concrete. Furthermore, the result of the experiment is compared with those of analysis by the program which is developed in KAIST. As a result of comparison, the analytical results are in good approximation with experimental data.

  • PDF

이중확산 대류계에서의 부력효과에 관한 연구(II) - 이론적 연구 - (A Study on Buoyancy Effects in Double-Diffusive Convecting System(II) - Theoretical Study -)

  • 홍남호;김민찬;현명택
    • 한국해양공학회지
    • /
    • 제13권2호통권32호
    • /
    • pp.129-137
    • /
    • 1999
  • The time of the onset of double-diffusive convection in time-dependent, nonlinear concentration fields is investigated theoretically. The initially quiescent horizontal fluid layer with a uniform temperature gradient experiences a sudden concentration change from below, but its stable thermal stratification affects concentration effects in such way to invoke convective motion. The related stability analysis, including Soret effect, is conducted on the basis of the propagation theory. Under the linear stability theory the concentration penetration depth is used as a length scaling factor, and the similarity transform for the linearized perturbation equations. The newlly obtained stability equations are solved numerically. The resulting critical time to mark the onset of regular cells are obtained as a function of the thermal Rayleigh number, the solute Rayleigh number, and the Soret effect coefficient. For a certain value of the Soret effect coefficient, the stable thermal gradient promote double-diffusive convective motion.

  • PDF

투과계수를 고려한 의복과 인체 사이의 공기층에서 자연대류 특성 (Natural Convection for Air-Layer between Body Skin and Clothing with Considering Coefficient of Permeability)

  • 지명국;배강렬;정효민;정한식;추미선
    • 설비공학논문집
    • /
    • 제13권12호
    • /
    • pp.1282-1287
    • /
    • 2001
  • This study presents the numerical analysis of natural convection of a micro- environments with air permeability in the clothing air-layer. As a numerical model the clothing air layer of shoulder and arm were adopted. Finite volume method for two-dimensional laminar flow was used for the analysis of flow and thermal characteristics of velocity, temperature and concentration in the air layer between body and clothing. As temperature boundary conditions, a body skin has a high temperature with $34^{\circ}C$ and the environmental temperatures are 5, 15 and $25^{\circ}C$ for various permeability coefficients. The distributions of concentration, temperature and velocity are shown that two large cells form at horizontal and vertical air layer, respectively. As the temperature difference between body skin and environment decreases, the heat transfer is decreased rapidly.

  • PDF

2차원각주의 비정상 공력특성(SOLA스킴의 재평가) (Aerodynamic Characteristics of 2-D, Unsteady Flow Past a Square Cylinder (Revaluation of SOLA Scheme))

  • 이영호
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제14권2호
    • /
    • pp.48-65
    • /
    • 1990
  • Numerical solutions of the Navier-Stokes equations, governing 2-dimensional, time-dependent, viscous, incompressible fluid flow past a square cylinde in an infinite region, are presented for Reynolds numbers $10^2$, $10^3$and $10^4$. Finite-difference scheme, based on SOLA-VOF is adopted and a discretization of the convection term for irregular grid is newly suggested by altering the original nonconservation form into conservation one. Distribution of finer grids around the body reveals fairly reasonable consistency with the experimental variables : drag coefficient, lift coefficient, Strouhal number, fluctuating pressure coefficient, etc.

  • PDF