• 제목/요약/키워드: Convection Heat Transfer

검색결과 971건 처리시간 0.022초

튜브의 열전도도와 튜브 외면에서의 대류열전달이 보텍스튜브의 에너지 분리에 미치는 영향 (The Effect of the Thermal Conductivity of a Tube and the Convective Heat Transfer on the Outer Surface of a Tube on the Energy Separation in Vortex Tubes)

  • 유갑중;이병화;최병철
    • 설비공학논문집
    • /
    • 제13권9호
    • /
    • pp.845-852
    • /
    • 2001
  • The phenomena of energy separation in vortex tubes was investigated experimentally to see the effects of the conductivity of a tube and convective heat transfer on the outer surface of a tube. The experiment was carried out with different conductivity (pyrex, stainless steel and copper) of a tube and three kinds of convective heat transfer modes (adiabatic condition, natural convection (air) and forced convection (water) on the outer surface of a tube. the results were obtained that hot exit fluid temperature was highly affected by a change of conductivity of a tube when the outer surface was cooled by the forced convection of water. However, the cold exit temperature was little affected by heat transfer modes on the outer surface in vortex tubes.

  • PDF

열원이 있는 삼각형 풀의 높은 Ra수 자연대류 (HIGH Ra NUMBER NATURAL CONVECTION IN A TRIANGULAR POOL WITH A HEAT GENERATION)

  • 김종태;박래준;김환열;홍성완;송진호;김상백
    • 한국전산유체공학회지
    • /
    • 제16권3호
    • /
    • pp.66-74
    • /
    • 2011
  • A fluid in an enclosure can be heated by electric heating, chemical reaction, or fission heat. In order to remove the volumetric heat of the fluid, the walls surrounding the enclosure must be cooled. In this case, a natural convection occurs in the pool of the fluid, and it has a dominant role in heat transfer to the surrounding walls. It can augment the heat transfer rates tens to hundreds times larger than conductive heat transfer. The heat transfer by a natural convection in a regular shape such as a square cavity or semi-circular pool has been studied experimentally and numerically for many years. A pool of an inverted triangular shape with 10 degree inclined bottom walls has a good cooling performance because of enhanced boiling critical heat flux (CHF) compared to horizontal downward surface. The coolability of the pool is determined by comparing the thermal load from the pool and the maximum heat flux removable by cooling mechanism such as radiative or boiling heat transfer on the pool boundaries. In order to evaluate the pool coolability, it is important to correctly expect the thermal load by a natural convection heat transfer of the pool. In this study, turbulence models with modifications for buoyancy effect were validated for unsteady natural convections by volumetric heating. And natural convection in the triangular pool was evaluated by using the models.

돌출 열원을 갖는 3차원 밀폐 공간내에서의 자연대류-복사 복합 열전달에 대한 실험적 및 수치적 연구 (An experimental and numerical study on natural convection-radiation conjugate heat transfer in a three-dimensional enclosure having a protruding heat source)

  • 백창인;이관수;김우승
    • 대한기계학회논문집B
    • /
    • 제20권10호
    • /
    • pp.3344-3354
    • /
    • 1996
  • An experimental and numerical study on the three-dimensional natural convection-radiation conjugate heat transfer in the enclosure with heat generating chip has been performed. A 3-dimensional simulation model is developed by considering heat transfer phenomena by conduction-convection and radiation. Radiative transfer was analyzed with the discrete ordinates method. Experiments are conducted in order to validate the numerical model. Comparisons with the experimental data show that good agreement is obtained when the radiation effect is considered. The effects of the thermal conductivity of the substrate and power level on heat transfer are investigated. It is shown that radiation is the dominant heat transfer mode and the conductivity of the substrate has important effects on the heat transfer in the enclosure.

양생조건·외기온도·비등효과를 고려한 콘크리트 외기대류계수의 결정 (Determination of Convection Heat Transfer Coefficient Considering Curing Condition, Ambient Temperature and Boiling Effect)

  • 최명성;김윤용;우상균;김진근
    • 콘크리트학회논문집
    • /
    • 제17권4호
    • /
    • pp.551-558
    • /
    • 2005
  • 이 연구에서는 외기와의 열전달을 나타내는 외기대류계수에 관한 실험을 실시하였다. 외기대류계수에 관한 기존의 모델에서 나타났던 문제점을 해결하기 위해 실험 변수로 풍속외에 양생 조건의 종류(양생포, 양생포+비닐), 외기온도, 비등효과를 선정하였다. 실험 결과를 이용하여 외기대류계수를 산정하고자 열평형 방정식을 이용한 수치해법을 사용하였으며, 이론적인 고찰을 통해 각 양생 조건별로 풍속에 따른 외기대류계수의 변화를 예측할 수 있는 모델식을 제안하였다. 열평형 방정식을 이용한 수치해법에서 초기에 외기대류계수가 과잉평가되는 문제점을 해결하기 위해 비등효과에 의한 증발량을 고려하여 수정 열평형 방정식을 제안하였다. 양생 조건을 고려한 제안된 모델식에 의하면, 모든 경우에 풍속에 따라 외기대류계수가 증가하는 경향을 보였으나 양생 재료의 사용여부나 양생 조건에 따라 다른 양상을 보이는 것을 알 수 있었다. 이러한 양상의 차이는 양생 재료의 열 특성에 의해 결정되는 것으로 외기대류계수는 양생 재료가 없는 경우, 양생포를 사용한 경우, 양생포+비닐을 사용한 경우의 순으로 풍속의 영향을 받는 것으로 나타났다. 제안된 모델식을 이용하면 수화열에 의한 콘크리트 구조물의 온도해석시 보다 정확한 결과를 얻을 수 있을 것으로 사료되며, 향후 이러한 열특성계수에 대한 연구가 필요할 것으로 판단된다.

강제 공냉 평판형 핀 방열판에 대한 실험적 고찰 (Experimental Investigation of Forced Air Cooled Plate Fin Heat Sinks)

  • 김태엽
    • 전력전자학회논문지
    • /
    • 제24권6호
    • /
    • pp.428-437
    • /
    • 2019
  • Analytical thermal models based on average convection heat transfer are frequently used for the design and selection of forced air-cooled plate fin heat sinks. In this paper, a convection heat transfer model within a ±10% margin of error was presented through experimental investigation. Five types of heat sinks with inlet widths of 1.7-6.8 mm were tested at 50-160 W heat sources to derive and verify the model. Causes of error between the experiment and analytical thermal model were analyzed and listed to design the heat sink. Using proposed method and the lists to be considered in the paper, a quick and accurate heat sink design of the power-conversion system is expected.

대류를 고려한 열전달 시스템의 민감도 해석 및 위상 최적 설계 (Design Sensitivity Analysis and Topology Optimization of Thermal Systems Considering Convection Heat Transfer)

  • 문희곤;왕세명;심호경
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1053-1057
    • /
    • 2004
  • This paper presents the adjoint variable design sensitivity analysis for thermal systems considering both conduction and convection heat transfer. Both nodal temperature and total heat flow are considered to be objective functions and design sensitivity formulas are derived for each case. For the case of convection heat transfer, the adjoint analysis is carefully proceeded to obtain a precise result. A topology optimization example is examined for a simple planar square plate in order to design a heat exchanger as verification.

  • PDF

두 등온 수평 평판 사이의 상변화 열전달 (Heat Transfer with Phase Change between Two Isothermal Horizontal Plates)

  • 서용권
    • 설비공학논문집
    • /
    • 제4권4호
    • /
    • pp.323-331
    • /
    • 1992
  • A two-dimensional Benard-convection system with a phase-change material inside has been analysed. The main purpose of the present study is to clarify the basic reason of the hysteresis found by the previous investigators. The interface between the solid and the liquid is assumed to be planar. The analysis was performed with heat transfer rates under the steady state on the interface. It was found that the hysteresis occurs due to the abrupt increase in the heat transfer rate at the onset of natural convection in the classical Benard-convection system. The spectral method was applied to obtain the steady solution of the natural convection for the specific material and to confirm the hysteresis phenomenon.

  • PDF

삼각형 형상의 풀 내에서 열원에 의한 자연대류 수치해석 (NATURAL CONVECTION IN A TRIANGULAR POOL WITH VOLUMETRIC HEAT GENERATION)

  • 김종태;박래준;김환열;송진호
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2011년 춘계학술대회논문집
    • /
    • pp.302-310
    • /
    • 2011
  • A fluid in an enclosure can be heated by electric heating, chemical reaction, or fission heat. In order to remove the volumetric heat of the fluid, the walls surrounding the enclosure must be cooled. In this case, a natural convection occurs in the pool of the fluid, and it has a dominant role in heat transfer to the surrounding walls. It can augment the heat transfer rates tens to hundreds times larger than conductive heat transfer. The heat transfer by a natural convection in a regular shape such as a square cavity or semi-circular pool has been studied experimentally and numerically for many years. A pool of an inverted triangular shape with 10 degree inclined bottom walls has a good cooling performance because of enhanced boiling critical heat flux (CHF) compared to horizontal downward surface. The coolability of the pool is determined by comparing the thermal load from the pool and the maximum heat flux removable by cooling mechanism such as radiative or boiling heat transfer on the pool boundaries. In order to evaluate the pool coolability, it is important to correctly expect the thermal load by a natural convection heat transfer of the pool. In this study, turbulence models with modifications for buoyancy effect were validated for unsteady natural convections by volumetric heating. And natural convection in the triangular pool was evaluated by using the models.

  • PDF

다양한 형상의 Heat Sink 열저항 특성에 관한 실험적 연구 (An Experimental Study on the Thermal Resistance Characteristics for Various Types of Heat Sinks)

  • 김종하;윤재호;이창식
    • 설비공학논문집
    • /
    • 제14권8호
    • /
    • pp.676-682
    • /
    • 2002
  • This paper has been made to investigate the thermal performance characteristics for the several types of heat sinks such as extruded heat sink, aluminum foam heat sink, layered heat sink. The various types heat sinks are prepared and tested for natural convection as well as forced convection. The experimental results for natural convection are compared to those for three types of heat sink so that the appropriate heat sink can be designed or chosen according to the heating conditions. The overall heat transfer performances for layered heat sink, extruded heat sink and aluminum foam heat sink are almost comparable to those under natural convection and forced convection. The forced convection of layered heat sink become 1.2 times as high as those of extruded heat sink, and the forced convection of extruded heat sink become 1.2 times as high as those of aluminum foam heat sink. This study shows that bar height, bar distance and number of bar for layered heat sink are important parameters, which have a serious influence on thermal performance for layered heat sinks.

열전달을 이용한 엔진오일 열화 감지 방법 (A Method for Detecting Engine Oil Deterioration using Heat Transfer)

  • 김형표
    • 센서학회지
    • /
    • 제13권2호
    • /
    • pp.139-143
    • /
    • 2004
  • This paper presents a method that the engine oil condition is detected using a natural convection heat transfer in a engine oil. A sensor circuit maintains a constant temperature difference between a heat plate and engine oil for detecting a natural convection heat transfer rate on the constant temperature. The natural convection heat transfer rate is measured by a current through the heat plate of the sensor circuit. The sensor is tested by a fresh oil. 6,000 km and 10,000 km driven oil in the oil temperature range from $20^{\circ}C$ to $100^{\circ}C$. In the experimental result, when the current through the heat plate is altered by variation of a engine oil temperature and flows driven oil more than fresh oil, the sensor could inform a engine oil deterioration to a car driver.