• Title/Summary/Keyword: Controlled Index Terms

Search Result 50, Processing Time 0.027 seconds

Acupuncture for Facet Joint Syndrome: A Review of Clinical Study (후관절 증후군의 침 치료에 대한 문헌 연구 보고)

  • Ji-Hyang Gu
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.33 no.1
    • /
    • pp.13-29
    • /
    • 2023
  • Objectives To evaluate the evidence supporting the effectiveness of acupuncture for facet joint syndrome. Methods We conducted search across 9 electronic databases (PubMed, EMBASE, Cochrane CENTRAL (CENTRAL), KoreaMed, Kmbase, Koreanstudies Information Service System (KISS), ScienceOn, China National Knowledge Infrastructure (CNKI), and Wanfang) to find clinical trials that used acupuncture as treatment for facet joint syndrome. The methodological quality of randomized controlled clinical trials (RCTs) were assessed using the Cochrane Risk of Bias (RoB) tool, while non-randomized controlled clinical trials (nRCTs) were assessed using the Cochrane Risk of Bias Assessment tool for Non-randomized Study (RoBANS) tool. Results Nine RCTs and one nRCT met our inclusion criteria. Fire needle was more effective than medial branch block in terms of visual analogue scale (VAS) after 1 month (p=0.02). Also, Fire needle was more effective than Ibuprofen in terms of VAS and oswestry disability index (ODI) (p<0.05). However, in the rest of the study results, the intervention group did not show a statistically significant difference than the control group. Conclusions Although our review found encouraging but limited evidence of acupuncture for facet joint syndrome, most of the studies included in the analysis were evaluated as methodologically high risk of bias. From now on further well-designed RCTs should be encouraged.

A Review of the Study Trends on the Relationship between Primary Dysmenorrhea and Doppler Indicies of Uterine Artery (일차성 월경통과 자궁동맥의 혈류역학적 측정값의 관련성에 대한 최신 연구 동향)

  • Kim, Hyo-Jung;Hwang, Deok-Sang;Lee, Jin-Moo;Lee, Chang-Hoon;Jang, Jun-Bock
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.34 no.4
    • /
    • pp.97-110
    • /
    • 2021
  • Objectives: This study was performed to review the research trends in the relationship between primary dysmenorrhea and doppler indicies of uterine artery. Methods: The search for related papers used 'Pubmed', a reserch engine in the America National Library of Medicine and Korean studies Information Service System (KISS). Used searching terms were 'primary dysmenorrhea', 'menstrual pain' in all cases. And among these studies, we searched by using key word 'uterine artery', 'doppler indices', 'doppler parameters', 'pulsatile index', 'resistance index'. Results: Overall 49 studies, 8 studies were finally selected to this study. There were 6 controlled studies and 2 randomised-controlled studies. In all 8 studies, transvaginal ultrasound was used to measure the resistance of uterine blood vessels. All of these studies reported that in patients with primary dysmenorrhea, hemodynamic values of uterine arteries measured by Doppler ultrasound were significantly higher than in normal subjects. Conclusions: According to the results, it was found that there was a positive correlation between the pain level of primary dysmenorrhea and the pulsation index and resistance index of the uterine artery. Based on these results, it can be seen that the doppler indicies of uterine artery have the potential to be used as an evaluation scale for Korean traditional medicine for primary dysmenorrhea.

Innovative customized CAD/CAM nickel-titanium lingual retainer versus standard stainless-steel lingual retainer: A randomized controlled trial

  • Gelin, Emilie;Seidel, Laurence;Bruwier, Annick;Albert, Adelin;Charavet, Carole
    • The korean journal of orthodontics
    • /
    • v.50 no.6
    • /
    • pp.373-382
    • /
    • 2020
  • Objective: To compare computer-aided design and computer-aided manufacturing (CAD/CAM) customized nitinol retainers with standard stainless-steel fixed retainers over a 12-month study period. Methods: This randomized controlled trial (RCT) was conducted on 62 patients randomly allocated to a control group that received stainless-steel retainers or a test group that received customized CAD/CAM nickel-titanium retainers. Four time points were defined: retainer placement (T0) and 1-month (T1), 6-month (T2), and 12-month (T3) follow-up appointments. At each time point, Little's irregularity index (LII) (primary endpoint) and dental stability measurements such as intercanine width were recorded in addition to assessment of periodontal parameters. Radiological measurements such as the incisor mandibular plane angle (IMPA) were recorded at T0 and T3. Failure events (wire integrity or debonding) were assessed at each time point. Results: From T0 to T3, LII and other dental measurements showed no significant differences between the two groups. The data for periodontal parameters remained stable over the study period, except for the gingival index, which was slightly, but significantly, higher in the test group at T3 (p = 0.039). The IMPA angle showed no intergroup difference. The two groups showed no significant difference in debonding events. Conclusions: This RCT conducted over a 12-month period demonstrated no significant difference between customized CAD/CAM nickel-titanium lingual retainers and standard stainless-steel lingual retainers in terms of dental anterior stability and retainer survival. Both retainers eventually appeared to be equally effective in maintaining periodontal health.

Acupuncture and Electroacupuncture Treatment for Temporomandibular Joint Disorder Focused on Recent Randomized-Controlled Studies: A Systematic Review and Meta-Analysis

  • Jin-Sol Yoon;Joonyong Noh;Seonju Ahn;Yun-Gwon Seon;Hong-Wook Choi;Sun-Joong Kim;Jae-Uk Sul;Jae-Hong Kim
    • Journal of Acupuncture Research
    • /
    • v.40 no.3
    • /
    • pp.214-237
    • /
    • 2023
  • This study aimed to evaluate the clinical efficacy and safety of acupuncture and electroacupuncture for temporomandibular joint disorder (TMD). We searched 11 databases to find randomized-controlled trials (RCTs) published between January 2018 and January 2023 that used acupuncture and electroacupuncture to treat patients with TMD. We performed a meta-analysis of 18 RCTs involving 1,109 patients. Nine studies reported that the treatment and control groups showed improvement in the evaluation index post-treatment. The results of the meta-analysis showed that the treatment groups receiving acupuncture combined with manual therapy had significantly improved visual analog scale score and dysfunction index than the control groups receiving manual therapy. Moreover, the treatment groups receiving acupuncture combined with Western medicine had statistically improved maximum mouth opening than the control groups using Western medicine. In conclusion, acupuncture and electroacupuncture have clinical effects on TMD patients. Given that 11 studies were obtained from the Chinese database, a regional bias would be considered. Furthermore, the included studies had high a risk of bias in terms of randomization, concealment, and blinding. Further studies are required to correct these limitations.

Optimum control system for earthquake-excited building structures with minimal number of actuators and sensors

  • He, Jia;Xu, You-Lin;Zhang, Chao-Dong;Zhang, Xiao-Hua
    • Smart Structures and Systems
    • /
    • v.16 no.6
    • /
    • pp.981-1002
    • /
    • 2015
  • For vibration control of civil structures, especially large civil structures, one of the important issues is how to place a minimal number of actuators and sensors at their respective optimal locations to achieve the predetermined control performance. In this paper, a methodology is presented for the determination of the minimal number and optimal location of actuators and sensors for vibration control of building structures under earthquake excitation. In the proposed methodology, the number and location of the actuators are first determined in terms of the sequence of performance index increments and the predetermined control performance. A multi-scale response reconstruction method is then extended to the controlled building structure for the determination of the minimal number and optimal placement of sensors with the objective that the reconstructed structural responses can be used as feedbacks for the vibration control while the predetermined control performance can be maintained. The feasibility and accuracy of the proposed methodology are finally investigated numerically through a 20-story shear building structure under the El-Centro ground excitation and the Kobe ground excitation. The numerical results show that with the limited number of sensors and actuators at their optimal locations, the predetermined control performance of the building structure can be achieved.

Effectiveness of graded motor imagery in subjects with frozen shoulder: a pilot randomized controlled trial

  • Gurudut, Peeyoosha;Godse, Apurva Nitin
    • The Korean Journal of Pain
    • /
    • v.35 no.2
    • /
    • pp.152-159
    • /
    • 2022
  • Background: Subjects with frozen shoulder (FS) might not be comfortable with vigorous physical therapy. Clinical trials assessing the effect of graded motor imagery (GMI) in FS are lacking. The aim of this study was to determine the effect of GMI as an adjunct to conventional physiotherapy in individuals with painful FS. Methods: Twenty subjects aged 40-65 years having stage I and II of FS were randomly divided into two study groups. The conventional physiotherapy group (n = 10) received electrotherapy and exercises while the GMI group (n = 10) received GMI along with the conventional physiotherapy thrice a week for 3 weeks. Pre- (Session 1) and post- (Session 9) intervention analysis for flexion, abduction, and external rotation range of motion (ROM) using a universal goniometer, fear of movement using the fear avoidance belief questionnaire (FABQ), pain with the visual analogue scale, and functional disability using the shoulder pain and disability index (SPADI) was done by a blinded assessor. Results: Statistically significant difference was seen within both the groups for all the outcomes. In terms of increasing abduction ROM as well as reducing fear of movement, pain, and functional disability, the GMI group was significantly better than control group. However, both groups were equally effective for improving flexion and external rotation ROM. Conclusions: Addition of GMI to the conventional physiotherapy proved to be superior to conventional physiotherapy alone in terms of reducing pain, kinesiophobia, and improving shoulder function for stage I and II of FS.

Effects of Dissolved Oxygen on Fungal Morphology and Process Rheology During Fed-Batch Processing of Ganoderma lucidum

  • Fazenda, Mariana L.;Harvey, Linda M.;McNeil, Brian
    • Journal of Microbiology and Biotechnology
    • /
    • v.20 no.4
    • /
    • pp.844-851
    • /
    • 2010
  • Controlling the dissolved oxygen (DO) in the fed-batch culture of the medicinal mushroom Ganoderma lucidum led to a 2-fold increase of the maximum biomass productivity compared with uncontrolled DO conditions. By contrast, extracellular polysaccharide (EPS) production was two times higher under oxygen limitation (uncontrolled DO) than under increased oxygen availability (controlled DO). Morphologically, dispersed mycelium was predominant under controlled DO conditions, with highly branched hyphae, consistent with the enhanced culture growth noted under these conditions, whereas in the uncontrolled DO process mycelial clumps were the most common morphology throughout the culture. However, in both cultures, clamp connections were found. This is an exciting new finding, which widens the applicability of this basidiomycete in submerged fermentation. In rheological terms, broths demonstrated shear-thinning behavior with a yield stress under both DO conditions. The flow curves were best described by the Herschel-Bulkley model: flow index down to 0.6 and consistency coefficient up to 0.2 and 0.6 Pa $s^n$ in uncontrolled and controlled cultures DO, respectively. The pseudoplastic behavior was entirely due to the fungal biomass, and not to the presence of EPS (rheological analysis of the filtered broth showed Newtonian behavior). It is clear from this study that dissolved oxygen tension is a critical process parameter that distinctly influences G. lucidum morphology and rheology, affecting the overall performance of the process. This study contributes to an improved understanding of the process physiology of submerged fermentation of G. lucidum.

A Study on the Application of Design Indicators of the High School Facilities - Focused on High School in Gyeonggi-do - (고교시설 디자인 지표의 적용 분석 연구 - 경기도 고등학교를 중심으로 -)

  • Cho, Kyung-Sik;Belyalova, Aigerim
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.24 no.6
    • /
    • pp.45-53
    • /
    • 2017
  • The purpose of this study is to provide the fundamental data to improve a school building through comparing and analyzing facilities of high schools located in Gyeonggi - do Province on the basis of the Design Indicator for the Korean Educational Buildings. Two types of high schools were examined for this study. Some of them are high schools selected by Korean Ministry of Education as a school equipped with superior facilities and the others are high schools equipped with general facilities. 8 items such as safety, comfort, the function of education, utilization, the public, eco-friendliness, technology performance, economical efficiency were examined by 5 point Likert scale. Findings showed that all facilities of both types of high schools received high ratings in terms of safety, utilization, and technology performance. However, the evaluation index on 'various used outdoor space' and 'public buildings harmonized with surroundings' of the education function of both types of high schools was low, which implies that the facility related to the education function needs to be improved. It infers that facilities are simplified and harmony with surroundings disappears when altering the design of the school building due to the convenience of building and the problem of the budget. Therefore, these need to be primarily controlled. Additionally, in high schools with general facilities, the evaluation index on 'aesthetic interior and exterior design of comfort', 'the responsive space to the demand for teaching and learning of the function of education', and eco-friendless were so low that these factors need to be considered when designing the school building.

Clinical Efficacy and Safety of Controlled Distraction-Compression Technique Using Expandable Titanium Cage in Correction of Posttraumatic Kyphosis

  • Kang, Dongho;Lewis, Stephen J;Kim, Dong-Hwan
    • Journal of Korean Neurosurgical Society
    • /
    • v.65 no.1
    • /
    • pp.84-95
    • /
    • 2022
  • Objective : To investigate the clinical efficacy and safety of the controlled distraction-compression technique using an expandable titanium cage (ETC) in posttraumatic kyphosis (PTK). Methods : We retrospectively studied and collected data on 20 patients with PTK. From January 2014 to December 2017, the controlled distraction-compression technique using ETC was consecutively performed in 20 patients with PTK of the thoracolumbar zone (range, 36-82 years). Among them, nine were males and 11 were females and the mean age was 61.5 years. The patients were followed regularly at 1, 3, 6, and 12 months, and the last follow-up was more than 2 years after surgery. Results : The mean follow-up period was 27.3±7.3 months (range, 14-48). The average operation time was 286.8±33.1 minutes (range, 225-365). The preoperative regional kyphotic angle (RKA) ranged from 35.6° to 70.6° with an average of 47.5°±8.1°. The immediate postoperative mean RKA was 5.9°±3.8° (86.2% correction rate, p=0.000), and at the last follow-up more than 2 years later, the mean RKA was 9.2°±4.9° (80.2% correction rate, p=0.000). The preoperative mean thoracolumbar kyphosis was 49.1°±9.2° and was corrected to an average of 8.8°±5.3° immediately after surgery (p=0.000). At the last follow-up, a correction of 11.9°±6.3° was obtained (p=0.000). The preoperative mean back visual analog scale (VAS) score was 7.9±0.8 and at the last follow-up, the VAS score was improved to a mean of 2.3±1.0 with a 70.9% correction rate (p=0.000). The preoperative mean Oswestry disability index (ODI) score was 32.3±6.9 (64.6%) and the last follow-up ODI score was improved to a mean of 6.85±2.9 (3.7%) with a 78.8% correction rate (p=0.000). The overall complication was 15%, with two of distal junctional fractures and one of proximal junctional kyphosis and screw loosening. However, there were no complications directly related to the operation. Conclusion : Posterior vertebral column resection through the controlled distraction-compression technique using ETC showed safe and good results in terms of complications, and clinical and radiologic outcomes in PTK. However, to further evaluate the efficacy of this surgical procedure, more patients need long-term follow-up and there is a need to apply it to other diseases.

Outcomes of epidural steroids following percutaneous transforaminal endoscopic discectomy: a meta-analysis and systematic review

  • Song, Yinghao;Li, Changxi;Guan, Jingjing;Li, Cheng;Wu, Haisheng;Cheng, Xinzhi;Ling, Bingyu;Zhang, Jinglang
    • The Korean Journal of Pain
    • /
    • v.35 no.1
    • /
    • pp.97-105
    • /
    • 2022
  • Background: Percutaneous transforaminal endoscopic discectomy (PTED) has been widely used in the treatment of lumbar degenerative diseases. Epidural injection of steroids can reduce the incidence and duration of postoperative pain in a short period of time. Although steroids are widely believed to reduce the effect of surgical trauma, the observation indicators are not uniform, especially the long-term effects, so the problem remains controversial. Therefore, the purpose of this paper was to evaluate the efficacy of epidural steroids following PTED. Methods: We searched PubMed, Embase, and the Cochrane Database from 1980 to June 2021 to identify randomized and non-randomized controlled trials comparing epidural steroids and saline alone following PTED. The primary outcomes included postoperative pain at least 6 months as assessed using a visual analogue scale (VAS) and the Oswestry Disability Index (ODI). The secondary outcomes included length of hospital stay and the time of return to work. Results: A total of 451 patients were included in three randomized and two non-randomized controlled trials. The primary outcomes, including VAS and ODI scores, did not differ significantly between epidural steroids following PTED and saline alone. There were no significant intergroup differences in length of hospital stay. Epidural steroids were shown to be superior in terms of the time to return to work (P < 0.001). Conclusions: Intraoperative epidural steroids did not provide significant benefits, leg pain control, improvement in ODI scores, and length of stay in the hospital, but it can enable the patient to return to work faster.