• Title/Summary/Keyword: Controllable load

Search Result 83, Processing Time 0.02 seconds

The Characteristic of the Hydraulic Control System with Bleed-off Center Type of a Compact Excavator (소형 굴삭기용 브리드 오프 센터형 유압 제어 시스템의 특성)

  • Kim, Jun-Sik;Lee, Seung-Hyun;Lee, Jae-Won
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.32 no.2
    • /
    • pp.119-126
    • /
    • 2008
  • In this study, the characteristics of the hydraulic control system with bleed-off center type of a compact excavator were analyzed using developed analysis program. From the parametric analysis, the effects of each factor were revealed. Through the simulation with varying parameters, the system parameter effects on the controllable region and the pump pressure and load pressure variations were studied. The results were compared with the experimental ones. The results and discussions of the present paper could aid in the performance improvement of a hydraulic control system of a compact excavator.

Effect of Elastic Modulus Mismatch on the Contact Crack Initiation in Hard Ceramic Coating Layer

  • Lee, Kee-Sung
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.12
    • /
    • pp.1928-1937
    • /
    • 2003
  • Effect of elastic modulus mismatch on the contact crack initiation is investigated to find major parameters in designing desirable surface-coated system. Silicon nitride coated soft materials with various elastic modulus mismatch, E$\_$c//E$\_$s/=1.06∼356 are prepared for the analysis. Hertzian contact test is conducted for producing contact cracks and the acoustic emission detecting technique for measuring the critical load of crack initiation. The implication is that coating thickness and material strength are controllable parameters to prevent the initiation of contact cracks resulted from the elastic modulus mismatch in the hard ceramic coating layer on the soft materials.

Performance Analysis of Smart Impact Damper (지능형 완충기의 특성 해석)

  • ;;Y.T. Choi
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.323-327
    • /
    • 2001
  • Electrorheological(ER) and magnetorheological(MR) fluids have a unique ability to increase the dynamic yield stress of the fluid substantially when electric or magnetic field is applied. Controllable fluids such as ER and MR fluids have received considerable attention as several components of engineering devices. One of them is a smart impact damper using ER/MR fluids. Impact damper system can be used in the joint mechanism of railroad vehicle, protection equipment of elevator's drop, and launch equipment of aircraft. This paper presents the results of an analytical study of the performance of a smart impact damper to suppress vibration during impact excitation. The damping capabilities of MR impact damper for variable applied current are analyzed using Bingham model under sudden impact load.

  • PDF

Dual Address Electrodes for Fast Addressing Method of ac-PDP with High Xe% Working Gas

  • Lee, D.K.;Choi, J.H.;Choi, W.S.;Ok, J.W.;Kwon, B.S.;Lee, H.J.;Lee, H.J.;Kim, D.H.;Park, C.H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07a
    • /
    • pp.247-250
    • /
    • 2005
  • In this paper, new address electrode having separated dual electrodes is suggested to reduce addressing time in ac PDP. It had been found that both the formative and jitter width of the suggested electrode are improved by $10{\sim}20$ % compared with the conventional one on IMID 04'. So we experiment other several kinds of the separated electrodes, and the change in discharge characteristics is analyzed by using a two-dimensional fluid simulation. The key feature of the suggested structure is that the distribution of Xe and Ne ion is controllable during the address periods without significant increases in the capacitive load of the address electrodes.

  • PDF

Controllable Load Management In A Competitive Electricity Market (경쟁적 전력시장의 부하관리 시스템에 관한 연구)

  • Kim, Jin-Ho;Han, Tae-Kyung;Nam, Young-Woo;Park, Jong-Bae;Kim, Bal-Ho H.;Park, Jong-Keun;Seo, Jang-Chul;Lee, Jin-Ho;Choi, Jong-Woong
    • Proceedings of the KIEE Conference
    • /
    • 2001.11b
    • /
    • pp.41-43
    • /
    • 2001
  • 경쟁적 전력시장의 도입으로 시장의 모든 참여자들은 자신의 효용이나 수익을 극대화하게 된다. 이에 따라 수용가들은 효용극대화 및 비용최소화를 위한 적극적인 전력소비전략을 필요로 하게 되며, 이를 위해 경쟁적 시장의 부하관리 시스템에 대한 관심이 증가하고 있다. 본 논문에서는 경쟁적 전력시장의 에너지비용절감을 위한 부하관리시스템의 국내외 연구 동향 및 사례들을 조사 분석하였으며 이를 바탕으로 국내 적용 가능성 등을 연구하였다.

  • PDF

Efficiency Optimization Control for Energy Saving of IPMSM Drive (IPMSM 구동의 에너지 절감을 위한 효율 최적화 제어)

  • 정동화;이정철;이홍균
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.12
    • /
    • pp.697-703
    • /
    • 2002
  • Interior permanent magnet synchronous motor(IPMSM) is widely used in many applications such as an electric vehicle, compressor drives of air conditioner and machine tool spindle drives. In order to maximize the efficiency in such applications, this paper is proposed the optimal control method of the armature current. The controllable electrical loss which consists of the copper loss and the iron loss can be minimized by the optimal control of the armature current. The minimization of loss is possible to realize efficiency optimization control for the proposed IPMSM The optimal current can be decided according to the operating speed and the load conditions. The proposed control algorithm is applied to IPMSM drive system, the operating characteristics controlled by efficiency optimization control are examined in detail by simulation.

Energy Demand Management Algoritm for Buildings and Application Procedure (건물군 에너지 수요관리 알고리즘 및 적용 절차)

  • Kim, Jeong-Uk
    • Journal of Energy Engineering
    • /
    • v.25 no.2
    • /
    • pp.79-85
    • /
    • 2016
  • This paper presents an advanced energy demand management for buildings. It is important to aggregate a various demand side resource which is controllable on demand response environment. Previous demand side algorithm for building is mostly restricted on single building. In this paper, we suggest energy demand management algorithm for many buildings. And, this paper shows the procedure to apply suggested demand management algorithm.

A Study on Static Var Compensator Using Multi Voltage Source Inverter (다중화 전압원 인버어터를 이용한 무효전력 보상장치(SVC)에 관한 연구)

  • Mo, Chang-Oh;Kim, Hong-Gyu;Khang, Seog-Gu;Kim, Young-Min;Park, Hyun-Chul;Yu, Chul-Ro
    • Proceedings of the KIEE Conference
    • /
    • 1995.07a
    • /
    • pp.403-406
    • /
    • 1995
  • In general, the reactive power is controlled by amplitude of the output voltage. This paper propose that the multiple voltage source inverter have controllable power factor made by load vary at receive-stage as lagging and leakage control.

  • PDF

Effect of Time-Related Parameters on Rockwell Hardness Measurement (시험시간 관련인자가 로크웰 경도측정에 미치는 영향)

  • Bahng Gun Woong;Tak Nae-Myung
    • Polymer(Korea)
    • /
    • v.29 no.6
    • /
    • pp.536-542
    • /
    • 2005
  • The effect of lime-related parameters such as loading velocity, load application time, gauge reading time on Rockwell hardness measurement was investigated for PE, PP PVC, and PMMA. It was found that keeping the specific requirements in the same condition is very important to obtain reliable and repeatable darn in polymer hardness measurement. The optimum condition for hardness measurement was 4 sec for load application time,15 sec for test load application net time, and 15 sec for gauge reading time after unloading. Using thess conditions, round robin test was carried out for 6 laboratories and it was shown that the testing machine should be one in which time-related variables are controllable. Indirect verification of hardness tester using brass reference block was not enough to guarantee the test results for polymer.

Development of Novel 3-Phase Line-interactive UPS System using 4-leg PWM Converter/Inverter and AC Reactor (4-레그 PWM 컨버터/인버터와 AC 리액터를 사용한 새로운 3상 라인 인터렉터브 무정전전원장치의 개발)

  • Ji Jun-Keun;Kim Hyo-sung;Sul Seung-Ki;Kim Kyung-Hwan
    • Proceedings of the KIPE Conference
    • /
    • 2004.07a
    • /
    • pp.77-81
    • /
    • 2004
  • In this paper a novel line interactive UPS (Uninterruptible Power Supply) using the two 4-leg VSCs and AC line reactor is proposed. The 4-leg Voltage Source Converter(VSC) can use the DC link voltage effectively by the 3-D SVPWM method. Hence the DC battery voltage can be reduced by $15\%$ in comparison to that of the conventional line-interactive UPS system. One VSC is in parallel with the AC line reactor of the power source side, and the other is in series with the load. The parallel 4-leg voltage source inverter controls three-phase line voltage independently in order to control the line reactor current indirectly. It eliminates the neutral line current and the active ripple power of the source side using the pqr theory so that unity power factor and the sinusoidal source current can be achieved even though both the source and the load voltages have zero sequence components. The series 4-leg voltage source inverter compensates the line voltage and allows the load voltage to be balanced and harmonic-free. Both of parallel and series 4-leg voltage source inverters always act as independently controllable voltage sources, so that three-phase output voltage shows a seamless transition to the backup mode. The feasibility of the proposed UPS system has been investigated and verified through computer simulation results.

  • PDF