• Title/Summary/Keyword: Control-Display

Search Result 1,842, Processing Time 0.034 seconds

Development of Narrow Viewing Angle Mode TFT LCD and Application of Advanced Gray Compensation(GC) Algorithm

  • Kim, S.H.;Lee, K.J.;Jung, Y.C.;Lee, D.G.;Baek, J.S.;Ahn, B.C.;Choi, H.C.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.1383-1385
    • /
    • 2008
  • In the viewing-angle image control (VIC) technology, one pixel is made up of a quad pixel structure which is consisting of R, G, B, and electrically control briefringence (ECB) sub-pixels. Two types of test stimuli were used; text & complex image respectively. The limitations of those methods were found from the experiment. From the results the advanced GC technology was proposed.

  • PDF

The Control of Electrostatic Characteristics in Toner Type Paper-like Display

  • Lee, Sung-Guk;Kwon, Soon-Hyung;Cho, Won-Ki;Song, Moon-Bong;Kim, Young-Woon
    • Journal of Information Display
    • /
    • v.8 no.1
    • /
    • pp.14-17
    • /
    • 2007
  • The toner type paper-like display (PLD) has been developed with two polymer particles having opposite polarity composed of polymer, colorant and external additives (nano-sized silica). Nano-sized silica with triboelectric charge was used for the charge control agent (CCA) and influenced on the electrostatic properties of the silica-coated polymer particles. The surface morphology and the cohesiveness of silica-coated polymer particles were changed with the silica coating time. From these results, it was verified that the PLD cell using silica-coated particles (200 seconds) shows a good white appearance and low driving voltage.

The Evaluation Method for Viewing Angle Image Control (VIC) Technology

  • Kwon, Jung-Bum;Park, Seung-Chul;Le, Don-Gyou;Lee, Lim-Soo;Ahn, Byung-Chul
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.700-702
    • /
    • 2008
  • A new evaluation method which named 'Security Viewing Angle Factor (SVAF)' was suggested for VIC (Viewing-angle Image Control) technology to quantify a visual hiding performance of LCD. Currently, Contrast Ration (CR) is the general method to evaluate VIC technology. However, CR shows a significant difference when compared with the result of human visual system. Furthermore, a perceptional evaluation method and its conditions were established.

  • PDF

Low Power Consumption Technology for Mobile Display

  • Lee, Joo-Hyung
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.402-403
    • /
    • 2009
  • A variety of power reduction technologies is introduced and the benefits of the technologies are discussed. PenTile$^{(R)}$ DBLC (Dynamic Brightness LED Control) combined with SABC (Sensor-Based Adaptive Brightness Control) enables to achieve the average LED power consumption to one third. The panel power reduction of 25% can be achieved with low power driving technology, ALS (Active Level Shifter). MIP (Memory In Pixel) is expected to be useful in transflective display because the whole display area can be utilized in reflective mode with power consumption of 1mW.

  • PDF

Ergonomic Considerations for the Design of a CRT-based Process Control System (CRT 방식 생산공정 제어용 계장시스템 설비의 인간공학적 고찰)

  • Chung, Min-Keun;Choi, Jae-Hyun;Jung, Eui-Seung
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.16 no.2
    • /
    • pp.11-21
    • /
    • 1990
  • With a general trend toward larger and more complex systems with centralized control, an operator's role of supervisory decision making in the control room becomes more important. Identification of potential man-machine interface (MMI) problems with CRT-based process control systems was attempted using a structured questionnaire survey. Based on the survey results, a laboratory experiment was carried out to investigate the performance of alarm detection on a process control CRT display. The user performance was measured in terms of reaction time from the onset of an alarm sound until the completion of predefined response procedures. The results revealed that for a highly complex tasks, mean reaction time ($\bar{RT}$) with a color consistent display was 10.5% faster than that with the original display, and $\bar{RT}$ with a grouped display was reduced by 8.2% in comparison with the color consistent display.

  • PDF

Organization of Control/Display on Visual Display Units (제품 조작 부위의 Control/Display 배열 관계에 대한 고찰)

  • 박현철
    • Proceedings of the Korea Society of Design Studies Conference
    • /
    • 1999.10a
    • /
    • pp.34-35
    • /
    • 1999
  • 컴퓨터 기술을 활용한 하이테크 제품의 도래는 생활에 많은 편리함을 안겨 주었지만, 제품을 조작하는 사용자들에게 '사용의 어려움'이라는 새로운 문제를 초래하게 되었다. 과거의 많은 사용자들은 제품의 구성들을 단지 봄으로써 그것이 어떻게 작동할 것이라는 것을 인지할 수 있었지만, 현재에 많은 하이테크 제품의 작동 부분들은 그 기능들이 제품 내부의 마이크로칩 속에 내장됨으로서 형태만으로 그 기능들의 용도를 이해하기란 매우 어려운 문제가 되었다.(중략)

  • PDF

Ecological Interface Design for Air Traffic Control Display (항공기 관제 디스플레이의 생태학적 인터페이스 디자인에 관한 연구)

  • Ko, Seung-Moon;Myung, Ro-Hae
    • Journal of the Ergonomics Society of Korea
    • /
    • v.25 no.4
    • /
    • pp.103-113
    • /
    • 2006
  • The purpose of this study was to evaluate an effect of the new air traffic control display designed by Ecological Interface Design [EID]. The methodology of EID has not been applied to the development of the air traffic control display so far. To design a new air traffic control display by EID, We implemented Work Domain Analysis about the air traffic control domain and made the Work Domain Model that consisted of the five levels of the Abstraction Hierarchy. We extracted the Information Requirement from the completed Work Domain Model and the extracted information requirements from the model were used to design the new air traffic control display. We evaluated an effect of the new air traffic control display designed by EID. Participants for evaluating consisted of 14 active military air traffic controller of the Republic of Korea Air Force. Experiment was designed two factors within subject. Factors manipulated in the experiment included displays type to compare the existing type with the new ecological interface type and included complexity to compare the effect of the high complex situation with the effect of the low complex situation. Response time about questions with relation to air traffic collision situation, accuracy, and subjective work load were measured. The results reveled that EID type's display has a significant effect on response time, accuracy, and subjective work load and verified that EID could be applied to the air traffic control domain that is more complex and dynamic.

Tactile Transfer and Display Method using Data Glove and Vibration Motors Module (데이터 글로브와 진동모터를 이용한 촉각전달 및 제시 방법)

  • Kang, Hyung-Gu;Choi, Youngjin
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.19 no.12
    • /
    • pp.1138-1144
    • /
    • 2013
  • This paper proposes a tactile transfer and display method between a data glove and vibration motors module. The data glove is developed to capture the hand postures and to measure the grip forces. The measured data are simplified with the proposed 5-bit transfer and display algorithm, and the vibration motors module is developed to display the measured hand posture and grip force to the operator. The proposed 5-bit algorithm contains both an 8-step hand posture and 4-step grip force level information for tactile transfer to the vibration motors module. Also, the effectiveness of the proposed method is shown through several experiments.

Improvement of Railway Signaling System for KTX and Conventional Trains Operated on a Five-Display Signal System Under a Four-Display Signaling System (4현시 철도신호체계에서 KTX 및 일반열차의 5현시 신호체계 운행을 위한 시스템 개선방안)

  • Lee, See-bin;Lyou, Joon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.22 no.2
    • /
    • pp.162-169
    • /
    • 2016
  • Gyeong-bu railway line in Korea between Seoul and Cheon-an was built as two double tracks. A four-display signaling system, only for the metro line, was installed on the second double track so KTX and conventional trains can only operate on the first double track. This study suggests a method to allow KTX and conventional trains operated on the five-display signaling system to respond to accidents and track defects on the second double-track under the four-display signal system by means of problem analysis, calculation of breaking distances for KTX and conventional trains at each break mode, and improvement of the ATS system.

Object Control System Based on LED for Table Top Display (테이블 탑 디스플레이용 LED기반 객체 컨트롤 시스템 -증강현실을 위한 테이블 탑 디스플레이용 입력장치)

  • Oh, Jin-Sik;Jeong, Jong-Mun;Kim, Jeong-Sik;Yang, Hyung-Jeong;Lee, Chil-Woo
    • 한국HCI학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.224-229
    • /
    • 2008
  • In this paper, we propose an object control system on table top display to support augmented reality in which objects in real-world control computer-generated data. We developed LED-based object control system over table top display so that it is capable of controlling networked table top display. The LED-based object control system supports more natural interactive interface. In this paper, infrared LED is used to implement the object control device to be recognised by table top display. We applied LED-based object control system in air hockey game where a team has a point if their puck goes to opponent's net on a table. Since users can control objects in cyber world with the proposed object control device, it is realized augmented reality.

  • PDF