• Title/Summary/Keyword: Control scheme

Search Result 7,029, Processing Time 0.034 seconds

Improved Nonlinear Speed Control of PM Synchronous Motor Using Time Delay Control

  • Baik, In-Cheol
    • Journal of Power Electronics
    • /
    • v.3 no.3
    • /
    • pp.197-204
    • /
    • 2003
  • An improved nonlinear speed control of a permanent magnet synchronous motor (PMSM) is presented A quasi-linearized and decoupled model including the influence of parameter variations and speed measurement error on the nonlinear speed control of a PMSM is derived Using this model, to overcome the drawbacks of conventional nonlinear control scheme, the improved nonlinear control scheme which employs time delay control (TDC) scheme is proposed. To show the validity of the proposed control scheme, simulation studies are carried out and compared with the conventional control scheme.

Robust control of robot manipulators using a decentralized control sheme (분산화 제어 기법을 이용한 로봇 매니퓰레이터의 강인 제어)

  • 최현철;한상완;홍석교
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.581-584
    • /
    • 1996
  • This paper presents the robust control of robot manipulators using a decentralized control scheme. The control scheme decouples the coupling dynamics between the joints and compensates the joint variable errors without any computation of the dynamics. The performance of the control scheme is compared with that of other control schemes such as the computed torque scheme and the adaptive control scheme by simulation.

  • PDF

Direct Power Control Scheme of Improved Command Tracking Capability for PMSG MV Wind turbines

  • Kwon, Gookmin;Suh, Yongsug
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.361-362
    • /
    • 2015
  • This paper proposes a Direct Power Control (DPC) scheme of improved command tracking capability for Permanent Magnet Synchronous Generator (PMSG) Medium Voltage (MV) Wind Turbines. Benchmarking is performed based on a neutral point clamped three-level back-to-back type voltage source converter. It is introduced to design the DPC modeling and propose DPC scheme of a three-level NPC (3L-NPC) converter. During the fault condition in wind farms, the proposed control scheme directly controls the generated output power to the command value from the hierarchical wind farm controller. The proposed control scheme is compared with conventional control scheme as respect to loss and thermal analysis. The DPC scheme of improved command tracking capability is confirmed through PLECS simulations. Simulation result shows that proposed control scheme achieves a much shorter transient time in a step response of generated output power. The proposed control scheme makes it possible to provide a good dynamic performance for PMSG MV wind turbine to generate a high quality output power under grid fault condition.

  • PDF

Study on Satellite Vibration Control using Adaptive Control Scheme

  • Oh, Se-Boung;Oh, Choong-Seok;Bang, Hyo-Choong
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.6 no.2
    • /
    • pp.1-16
    • /
    • 2005
  • Adaptive control methods are studied for the Satellite to isolate vibration in spite of the nonlinear system dynamics and parameter uncertainties of disturbance. First, a centralized control scheme is developed based on the particle swarm optimization(PSO) algorithm and feedback theory to automatically tune controller gains. A simulation study of a 3 degree-of-freedom device was conducted to evaluate the performance of the proposed control scheme. Next, since a centralized control scheme is hard to construct model dynamics and not goad at performance when controller and systems environment are easily changed, a decentralized control scheme is presented to avoid these defects of the centralized control scheme from the point of view of production and maintenance. It is based on the adaptive control methodologies to find PID controller parameters. Experiment studies were conducted to apply the adaptive control scheme and evaluate the performance of the proposed control scheme with those of the conventional control schemes.

A New Hybird Control Scheme Using Active-Clamped Class-E Inverter with Induction Heating Jar for High Power Applications

  • Lee, Dong-Yun;Hyun, Dong-Seok
    • Journal of Power Electronics
    • /
    • v.2 no.2
    • /
    • pp.104-111
    • /
    • 2002
  • This paper presents a new hybrid control scheme using Active-Clamped Class-E(ACCE) inverter for the Induction Heating (IH) jar. The proposed hybrid control scheme has characteristics, which acts as class-E inverter at lower switch voltage and ACCE inverter at higher switch voltage than reference voltage of the main switch by feeding back voltage of the switch. The proposedv hybrid control scheme also has advantage of conventional ACCE inverter such as Zero-Voltage-Switch(ZVS) of the main switch and the reduced switch voltage due to clamping cricuit. Moreover, the proposed hybrid control method using ACCE inverter has higher output power than convenional control scheme since ACCE inverter operates like class-E inverter at low input voltage condition. The principles of the proposed control are explained in detail and the validity of the proposed control scheme is verifed through the several interesting simulated and experimental results.

A.C. current control scheme for R-L load (R-L 부하에 대한 교류전류 제어방식)

  • 박민호;최규하
    • 전기의세계
    • /
    • v.29 no.12
    • /
    • pp.791-797
    • /
    • 1980
  • This paper is concerned with the study of improving the faults of phase control scheme and suggesting a new approach to the control of load circuit with AC source. AC current control can restrict the magnitude of current within the given upper and lower current and make current continuous during every cycle. Also the harmonic contents of current can be greatly reduced using this control scheme. Analog computer and digital computer simulations reveal that the current control scheme is superior to the phase control scheme in controlling the power supply to the load R-L. Experimintal results demonstrate the feasibility and verify the operation of current controlled system.

  • PDF

A VSR $\bar{X}$ Chart with Multi-state VSS and 2-state VSI Scheme

  • Lee, Jae-Heon;Park, Chang-Soon
    • Journal of Korean Society for Quality Management
    • /
    • v.32 no.4
    • /
    • pp.252-264
    • /
    • 2004
  • Variable sampling Interval (VSI) control charts vary the sampling interval according to value of the control statistic while the sample size is fixed. It is known that control charts with 2-state VSI scheme, which uses only two sampling intervals, give good statistical properties. Variable sample size (VSS) control charts vary the sample size according to value of the control statistic while the sampling interval is fixed. In the VSS scheme no optimal results are known for the number of sample sizes. It is also known that the variable sampling rate (VSR) $\bar{X}$ control chart with 2-state VSS and 2-state VSI scheme leads to large improvements In performance over the fixed sampling rate (FSR) $\bar{X}$ chart, but the optimal number of states for sample size Is not known. In this paper, the VSR Χ charts with multi-state VSS and 2-state VSI scheme are designed and compared to 2-state VSS and 2-state VSI scheme. The multi-state VSS scheme is considered to, achieve an additional improvement by switching from the 2-state VSS scheme. On the other hand, the multi-state VSI scheme is not considered because the 2-state scheme is known to be optimal. The 3-state VSS scheme improves substantially the sensitivity of the $\bar{X}$ chart especially for small and moderate mean shifts.

Traffic Signal Control Scheme for Traffic Detection System based on Wireless Sensor Network (무선 센서 네트워크 기반의 차량 검지 시스템을 위한 교통신호제어 기법)

  • Hong, Won-Kee;Shim, Woo-Seok
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.18 no.8
    • /
    • pp.719-724
    • /
    • 2012
  • A traffic detection system is a device that collects traffic information around an intersection. Most existing traffic detection systems provide very limited traffic information for signal control due to the restriction of vehicle detection area. A signal control scheme determines the transition among signal phases and the time that a phase lasts for. However, the existing signal control scheme do not resolve the traffic congestion effectively since they use restricted traffic information. In this paper, a new traffic detection system with a zone division signal control scheme is proposed to provide correct and detail traffic information and decrease the vehicle's waiting time at the intersection. The traffic detection system obtains traffic information in a way of vehicle-to-roadside communication between vehicles and sensor network. A new signal control scheme is built to exploit the sufficient traffic information provided by the proposed traffic detection system efficiently. Simulation results show that the proposed signal control scheme has 121 % and 56 % lower waiting time and delay time of vehicles at an intersection than other fuzzy signal control scheme.

A New Sensorless Control Scheme Using Simple Duty Feedback Technique in DC-DC Converters (DC-DC 컨버터에서 Duty Feedback 을 이용한 새로운 센서리스 제어 기법)

  • Noh Hyeong-Ju;Lee Dong-Yun;Hyun Dong-Seok
    • Proceedings of the KIPE Conference
    • /
    • 2001.12a
    • /
    • pp.115-118
    • /
    • 2001
  • This paper presents a new sensorless control scheme using simple duty signal feedback technique in DC-DC converters. The proposed sensorless control scheme (DFC) has the characteristics that they show the same as operation performance of current mode control by using duty feedback technique without current sensor as well as present better dynamic response performance than conventional sensorless current mode control (SCM) in case that input source is perturbed by step change or DC input source includes the . harmonics. Also, the proposed control scheme has good noise immunity and simple control circuits since they have one feedback loop, and can be applied to all DC-DC converters. The concept and control principles of the proposed control scheme are explained in detail and the validity of the proposed control scheme is verified through several interesting simulated results.

  • PDF

An Adaptive Checkpointing Scheme for Fault Tolerance of Real-Time Control Systems (실시간 제어 시스템의 결함 허용성을 위한 적응형 체크포인팅 기법)

  • Ryu, Sang-Moon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.15 no.6
    • /
    • pp.598-603
    • /
    • 2009
  • The checkpointing scheme is a well-known technique to cope with transient faults in digital systems. This paper proposes an adaptive checkpointing scheme for the reliability improvement of real-time control systems. The proposed adaptive checkpointing scheme is based on the previous work about the reliability problem of an equidistant checkpointing scheme. For the derivation of the adaptive scheme, some conditions are introduced which are to be satisfied for the reliability improvement by exploiting an equidistant checkpointing scheme. Numerical data show the proposed adaptive scheme outperforms the equidistant scheme from a reliability point of view.