• Title/Summary/Keyword: Control link

Search Result 2,427, Processing Time 0.031 seconds

Bluetooth Synchronous Connection Oriented Link Usage in Networked Control Systems (블루투스 Synchronous Connection Oriented Link를 사용한 네트워크 제어 시스템)

  • Umirov, Ulugbek;Park, Jung-Il
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.18 no.8
    • /
    • pp.731-737
    • /
    • 2012
  • In this paper the usage of Bluetooth in networked control systems is described. ACL links and commonly used serial port profile built on top of ACL links are analyzed and their problems such as unpredictable latency are discovered. SCO link packet scheduling, latency estimation and setup procedure are examined. SCO link is suggested as proper link for NCS, due to its low latency and low variance. Smith predictor use for latency compensation is described and its impact on control performance is estimated. A number of experiments on DC motor position control are performed and control performance of system utilizing SCO link with and without Smith predictor is proved to be higher than control performance of system utilizing ACL link.

A Digital Current Control using Single DC-Link Current Sensing of BLDC Actuation Systems (단일 DC-Link 전류 계측만을 이용한 BLDC 구동시스템의 디지털 전류 제어)

  • Hahn, Bongsu
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.22 no.1
    • /
    • pp.72-80
    • /
    • 2019
  • In this paper, we propose a digital DC-Link current control approach for BLDC actuation systems. The proposed approach consists of the following two components: first, DC-Link current measurement with sampling instances synchronized with PWM frequency, and second, current control using single DC-Link current rather than three phases current of a motor. The proposed method proved its performance through experiments and simulation. The results showed that the control performance are increased compared with the BLDC actuation system which does not use current control.

The Attitude Control of The Double Inverted Pendulum with Periodic Upper Disturbance (주기적인 상부 외란이 인가되는 2축 도립 진자의 자세 제어)

  • Nam, Row-Hyun;Yi, Keon-Young
    • Proceedings of the KIEE Conference
    • /
    • 1998.07g
    • /
    • pp.2309-2311
    • /
    • 1998
  • The attitude control of a double inverted pendulum with a periodical disturbance at link top is dealt in this paper. The proposed system is consisted of the double inverted pendulum and a disturbance link. The lower link is hinged on the plate to free for rotation in the vertical plane. The upper link is connected to the lower link through a DC motor. The DC motor is used to control the posture of the pendulum by adjusting the position of the upper link. The periodical disturbance can be generated by the additional link attached at the end of link 2 through another DC motor, which is the modeling of a posture for a biped supporting with one leg. The motor for the joint simulates the knee joint(or hip joint) and the disturbance for the legs moving in air. The algorithm for controlling a proposed inverted pendulum is consisted of a state feedback control and a fuzzy logic controller. The fuzzy controller keeps the center of gravity of the biped within the specified range through the nonlinear feedback compensator. The state feedback control takes over the role to maintain a desired posture regardless the disturbance at the link top. In these case, the change of the angle and COG of an upper link is compensated with on-line. Simulations with a mathematical model are conducted to show the validity of the proposed controller.

  • PDF

Design and Control Methods of Bidirectional DC-DC Converter for the Optimal DC-Link Voltage of PMSM Drive

  • Kim, Tae-Hoon;Lee, Jung-Hyo;Won, Chung-Yuen
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.6
    • /
    • pp.1944-1953
    • /
    • 2014
  • This paper shows the design and control methods of the bidirectional DC-DC converter to generate the proper DC-link voltage of a PMSM drive. Conventionally, because the controllable power of the PWM based voltage source inverter is limited by its DC-link voltage, the DC-DC converter is used for boosted DC-link voltage if the inverter source cannot generate enough operating voltage for the PMSM drive. In this paper, to obtain more utilization of this DC-DC converter, optimal DC-link voltage control for PMSM drive will be explained. First, the process and current path of the DC-DC converter will be illustrated, and a control method of this converter for variable DC-link voltage will then be explained. Finally, an improvement analysis of the optimal DC-link voltage control method, especially on the deadtime effect, will be explained. The DC-DC converter of the proposed control method is verified by the experiments by comparing with the conventional constant voltage control method.

Analysis of Output Characteristics for the Resonant DC Link Inverter Using PWM Inverter Modulation Methods (인버터 PWM 방식을 이용한 공진형 직류 링크 인버터의 출력 특성 해석)

  • 김윤호;윤병도;이병순
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.41 no.6
    • /
    • pp.615-624
    • /
    • 1992
  • For the operation of the resonant DC link inverters, only limited number of modulation techniques such as the delta modulation and instantaneous current control techniques have been suggested. However, these modulation techniques have some limitations in practical operation. In this paper, the application of conventional inverter modulation techniques is suggested for the control of the resonant DC link inverter. The harmonic analysis results are presented. The results show that these modulation techniques offer good output characteristics similar to conventional inverter PWM techniques for the operation of the resonant DC link inverter. This implies that not only the delta modulation technique and instantaneous current control techniques but also various other modulation techniques can be applied to the operation of the resonant DC link inverter. This also indicates that open loop control as well as closed loop control can be used for the operation of the resonant inverter. The resonant DC link inverter with various modulation strategies is implemented using V-40 microprocessors.

  • PDF

Control of Motor Drives Fed by PFC Circuits without DC-Link Electrolytic Capacitors

  • Kim, Kwang-Man;Kim, Eung-Ho;Choi, Jong-Woo
    • Journal of Power Electronics
    • /
    • v.18 no.4
    • /
    • pp.1067-1074
    • /
    • 2018
  • This paper presents a control method for variable-speed motor drives that do not use a DC-link electrolytic capacitor. The proposed circuit consists of a power factor correction converter for boosting the DC-link voltage, an inverter for driving the motor, and a small DC-link film capacitor. By employing a small DC-link capacitor, the proposed circuit that is small, and a low cost and weight are achieved. However, because the DC-link voltage varies periodically, the control of the circuit is more difficult than that of the conventional method. Using the proposed control method, an inverter can be controlled reliably even when the capacitance of the DC-link capacitor is very small. Experiments are performed using a 1.5-kW inverter with a $20-{\mu}F$ DC-link capacitor, and the experimental results are analyzed thoroughly.

Robust Position Control of a Single-Link Flexible Manipulator Using Sliding Mode and Piezofilm Actuator (슬라이딩모드와 압전필름 작동기를 이용한 단일링크 유연 머니퓰레이터의 강건위치제어)

  • 최승복
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.6
    • /
    • pp.1371-1381
    • /
    • 1995
  • A novel hybrid control scheme to actively control the endpoint position of a very flexible single-link manipulator is proposed. The control scheme consists of a motor mounted at the beam hub and a piezofilm actuator bonded to the surface of the flexible link. The control torque of the motor to produce a desired motion is firstly determined by employing the sliding mode control theory on the equation of motion of the rigid link having the same mass as that of the proposed flexible link. The torque is then applied to the flexible manipulator in order to activate the commanded motion. During the motion, undesirable oscillation is actively suppressed by applying a feedback control voltage to the piezofilm actuator. Consequently, the imposed desired position is accomplished. In order to demonstrate high control performances accrued from the proposed method, computer simulations are undertaken by treating both regulating and tracking control problems.

Data Link Control of TDX-1 ESS (TDX-1전전자 교환기의 데이터 링크 제어)

  • 유정주;최고봉;김영시
    • Proceedings of the Korean Institute of Communication Sciences Conference
    • /
    • 1987.04a
    • /
    • pp.93-97
    • /
    • 1987
  • In this paper the data link control procedures for the TDX-1 ESS had been designed and implemented in accordance with the CCITT recommandation X.25 LAPB After a general discussion on intermational standards of link montrol procedures the TDX-1 data link control procedures are described in detail.

  • PDF

Fuzzy Vibration Control of 3 DOF Robot Manipulator with Flexible Link (유연한 링크를 가진 3자유도 로봇조작기 진동의 펴지제어)

  • Kim, Jae-Won;Yang, Yang, Hyun-Seok;Park, Park, Young-Pil
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.20 no.12
    • /
    • pp.3883-3891
    • /
    • 1996
  • Performance and productivity of robot manipulator can be improved by increasing its working speed and extending its link length. But heavy weght of the commercial robot links, considered as "rigid body", limits its mazimum working speed and the weght of the links can be reduced for high speed operation. But this light-weight link or long link for special use cannot be consideredas "rigid" structure and vibration of the link due to its flexibility causes errors in end-effector position and orientation. Thus the elastic behaviro of the flexible link should be taken care of for increasing work speed and getting smaller error of end-effector position. In this paper, the fuzzy control theory is selected to design the controller which controlos the joint positions of the robot manipulator and suppress the vibration of flexible link. In the forst place, for the 1 DOF flexible link system, the fuzzy control theory is implemented. The contdroller for the 1 DOF flexible link system is designed. Experimental research is carried out to examine the controllability and the validity of the fuzzy control theory based controller. Next, using the extended desing schemes for the case of the 1 DOF flexible link system and usign the experimental phenomena of the 3 DOF flexible link system, the fuzzy controller for the 3 DOF flexible link system is desinged and experimented.ed and experimented.

A Performance Improvement Method of PMSM Torque Control Considering DC-link Voltage Variation (DC-link 전압변동을 고려한 PMSM 토크제어의 성능 향상 방법)

  • Lee, Jung-Hyo;Won, Chung-Yuen
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.11
    • /
    • pp.112-122
    • /
    • 2014
  • This paper proposes a PMSM torque control method considering DC-link voltage variation and friction torque. In general EV/HEV application, two dimensions look-up table(2D-LUT) is used for reference current generation due to its stable and robust torque control performance. Conventionally, this 2D-LUT is established by flux-torque table to overcome the DC-link voltage variation. However, the flux table establishment is more complex than the speed table establishment. Moreover, one flux data reflects several speed conditions in variable DC-link voltage, friction torque cannot be considered by using the flux table. In this paper, speed-torque 2D-LUT is used for current reference generation. With this table, PMSM torque control is well achieved regardless of DC-link voltage variation by the proposed control method. Simulation and experimental results validate improvement of torque control error through friction torque compensation.