• Title/Summary/Keyword: Control efficiency

Search Result 9,302, Processing Time 0.038 seconds

Efficiency Optimization Control of IPMSM Drive using HIC (HIC를 이용한 IPMSM 드라이브의 효율 최적화 제어)

  • Baek, Jung-Woo;Ko, Jae-Sub;Choi, Jung-Sik;Kang, Sung-Joon;Jang, Mi-Geum;Chung, Dong-Hwa
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.780_781
    • /
    • 2009
  • This paper proposes efficiency optimization control of IPMSM drive using hybrid intelligent controller(HIC). The design of the speed controller based on fuzzy-neural network that is implemented using fuzzy control and neural network. The design of the current based on adaptive fuzzy control using model reference and the estimation of the speed based on neural network using ANN controller. In order to maximize the efficiency in such applications, this paper proposes the optimal control method of the armature current. The optimal current can be decided according to the operating speed and the load conditions. This paper proposes speed control of IPMSM using ALM-FNN, current control of model reference adaptive fuzzy control(MTC) and estimation of speed using ANN controller. The proposed control algorithm is applied to IPMSM drive system controlled HIC, the operating characteristics controlled by efficiency optimization control are examined in detail.

  • PDF

Efficiency Optimization Control of IPMSM Drive using SPI Controller (SPI 제어기를 이용한 IPMSM 드라이브의 효율최적화 제어)

  • Ko, Jae-Sub;Chung, Dong-Hwa
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.7
    • /
    • pp.15-25
    • /
    • 2011
  • This proposes an online loss minimization algorithm for series PI(SPI) based interior permanent magnet synchronous motor(IPMSM) drive to yield high efficiency and high dynamic performance over wide speed range. The loss minimization algorithm is developed based on the motor model. In order to minimize the controllable electrical losses of the motor and thereby maximize the operating efficiency, the d-axis armature current is controlled optimally according to the operating speed and load conditions. For vector control purpose, a SPI is used as a speed controller which enables the utilization of the reluctance torque to achieve high dynamic performance as well as to operate the motor over a wide speed range. Also, this paper proposes current control of model reference adaptive fuzzy controller(MFC), and estimation of speed using artificial neural network(ANN) controller. The proposed efficiency optimization control, SPI, MFC, ANN in this paper is applied to IPMSM drive system, the validity of this paper is proved by analyzing response characteristics in variety operating conditions.

A Study on the Fault Tolerance and High Efficiency Control of 4 Leg DC/DC Converter for Battery Energy Storage System in Standalone DC Micro-grid (독립형 DC마이크로그리드 내 BESS용 4 LEG DC/DC 컨버터의 고장허용 및 고효율 제어에 관한 연구)

  • Choi, Jung-Sik;Oh, Seung-Yeol;Cha, Dae-Seak;Chung, Dong-Hwa
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.9
    • /
    • pp.1239-1248
    • /
    • 2018
  • This paper proposes a fault tolerant and high efficiency operation algorithm for a 4 LEG DC/DC converter for a battery energy storage system(BESS) forming a main power source in a standalone DC micro grid. The BESS for the main power supply in the stand-alone DC micro-grid is required to operate at high speed according to fault tolerant control and load by operating at all times. Fault-tolerance control changes the short-circuit fault to an open-circuit fault by using a fuse in case of leg fault in 4 legs, and operates stably through phase shift control. In addition, considering the loss of the power semiconductor, the number of LEG operation is adjusted to operate at high efficiency in the full load region. In this paper, fault tolerant control and high efficiency operation algorithm of DC/DC converter for BESS in standalone DC micro grid is presented and it is proved through simulation and experiment.

High Efficiency Operation of the IPT converter with Full and Half bridge Control for Electric Vehicles (전기자동차용 IPT 컨버터의 풀브릿지-하프브릿지 제어를 통한 고효율 운전 방법)

  • Ann, Sang-Joon;Joo, Dong-Myoung;Kim, Min-Kook;Lee, Byoung-Kuk
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.22 no.5
    • /
    • pp.423-430
    • /
    • 2017
  • This paper proposes a control methodology for a high efficiency operation of an inductive power transfer (IPT) converter by combining full bridge (FB) and half bridge (HB) controls. To apply the proposed control to the IPT converter, the characteristics of each control method are analyzed. By examining the output voltages of the IPT converter and a theoretical loss analysis, the control shifting points between FB and HB controls are evaluated in accordance with the coupling coefficients and the load. Based on the control shifting points, the FB-HB control algorithm is implemented. By applying FB-HB control, high efficiency operation at the light load condition can be achieved.

DITC of SRM using 4-Level Converter (4-레벨 컨버터 구동 방식에 의한 SRM DITC 제어)

  • Liang, Jianing;Lee, Zhen-Guo;Lee, Dong-Hee;Ahn, Jin-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2006.04b
    • /
    • pp.99-102
    • /
    • 2006
  • This paper proposes a DITC(Direct Instantaneous Torque Control of SRM (Switched Reluctance Motor) using a novel 4-level converter for smooth torque control and high efficiency. DITC of SRM is very useful for smooth torque control, but the driving efficiency is low due to advanced current that does not produce torque. For the high efficiency control of SRM, fast excitation and demagnetization of phase current are required. A novel 4-level converter and a new control scheme are present to improve the driving efficiency. The proposed DITC of SRM using 4-level converter is verified by computer simulation.

  • PDF

Optimal Efficiency Control for Induction Motor Drives

  • Kim Sang-uk;Choi Jin-ho;Kim Bo-youl;Kim Young-seok
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.428-433
    • /
    • 2001
  • This paper presents the control algorithm for maximum efficiency drives of an induction motor system with the high dynamic performance. This system uses a simple model of the induction motor that includes equations of iron losses. The model, which only requires the parameters of induction motor, is referred to a field-oriented frame. The minimum point of the input power can be obtained at the steady state condition. The reference torque and flux currents for the vector control of induction motors are calculated by the optimal efficiency control algorithm. The drive system with the proposed efficiency optimization controller has been implemented by a 32 bit floating point TMS320C32 DSP chip. The results show the effectiveness of the control strategy proposed for the induction motor drive.

  • PDF

Simulation Efficiency for Estimation of System Parameters in Computer Simulation (컴퓨터 시뮬레이션을 통한 시스템 파라미터 추정의 효율성)

  • Kwon, Chi-Myung
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.19 no.1
    • /
    • pp.61-71
    • /
    • 1993
  • We focus on a way of combining the Monte Calro methods of antithetic variates and control variates to reduce the variance of the estimator of the mean response in a simulation experiment. Combined Method applies antithetic variates (partially) for driving approiate stochastic model components to reduce the vaiance of estimator and utilizes the correlations between the response and control variates. We obtain the variance of the estimator for the response analytically and compare Combined Method with control variates method. We explore the efficiency of this method in reducing the variance of the estimator through the port operations model. Combined Method shows a better performance in reducing the variance of estimator than methods of antithetic variates and control variates in the range from 6% to 8%. The marginal efficiency gain of this method is modest for the example considered. When the effective set of control variates is small, the marginal efficiency gain may increase. Though these results are from the limited experiments, Combined Method could profitably be applied to large-scale simulation models.

  • PDF

Improved Maximum Efficiency Control of a Stator Flux-Oriented Induction Motor Drive (유도전동기 고정자자속기준제어의 개선된 최대효율제어)

  • Shin, Myoung-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.5
    • /
    • pp.58-63
    • /
    • 2008
  • A fast maximum efficiency control scheme of a stator flux-oriented control of an induction motor is proposed. Three inputs of given three magnetic fluxes are calculated. Then magnetic flux for minimum input is calculated by quadratic interpolation method and maximum efficiency control is fulfilled with the calculated magnetic flux for minimum input. Simulation results verify the effectiveness of the scheme.

A Study on Fuzzy Logic Based Intelligent Control of Robot System to Improve the Work Efficiency for Smart Factory

  • Kim, Hee-Jin;Kim, Dong-Ho;Han, Sung-Hyun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.24 no.6_1
    • /
    • pp.645-658
    • /
    • 2021
  • In this paper, we propose a new approach to intelligent control based on fuzzy logic for work efficiency improvement of smart factory by the applicaion of ariticulated robot. The intelligent control that is applied to the working process by the joint of robotic manipulator is the main focus to improve a work efficiency for implimentation of smart factory in general manufacturing process. In this study, we propose a new method of a fuzzy model and then develop a nonlinear relationship between interaction forces and manipulator position using a fuzzy model. The reliability of the proposed control method is illustrated by simulation and experiments.

A Study on the Sector Division for Effective Vessel Traffic Service : Focused on Daesan, Pyeongtaek and Inchon Harbour

  • Yang, Hyoung-Seon
    • Journal of Navigation and Port Research
    • /
    • v.34 no.4
    • /
    • pp.265-270
    • /
    • 2010
  • The national VTS was launched in 1993, and has adopted a harbour-oriented control method which is unable to consider enough characteristics of its work. However, for the past 17 years, the characteristics has changed due to increased amount of vessels. Up to now the domestic Vessel Traffic Service has adopted harbour-oriented control method which is unable to consider enough characteristics of its work. However, developed countries have carried out waters-oriented control method, according to the using areas of ships, to be well considered the characteristics of control for increasing efficiency of it. Especially, VTS of Daesan, Pyeongtaek and Inchon harbour can have confusions of control because of overlapped service areas of it. Therefore, in this paper suggested a new Sector Division that the relevants waters is divided into 3 operational Regions and these are divided into nine sectors again, for the purpose of improving the efficiency and the concentration of VTS.