• Title/Summary/Keyword: Control device

Search Result 5,509, Processing Time 0.042 seconds

Extra Dose Measurement of Differential Slice Thickness of MVCT Image with Helical Tomotherapy (토모테라피 치료 시 MVCT Image의 Slice Thickness 차이에 따른 선량 비교)

  • Lee, Byungkoo;Kang, Suman
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.2
    • /
    • pp.145-149
    • /
    • 2013
  • Helical Tomotherapy is an innovative means of delivering intensity modulated radiation therapy (IMRT) using a device that merges features of a linear accelerator and helical computed tomography (CT) scanner. Hereat, during helical tomotherapy process, megavoltage computed tomography (MVCT) image are usually used for guiding the precise set-up of patient before/after treatment delivery. But which would certainly increase the total dose for patients, this study was to investigate the imaging dose of MVCT using the cylindrical "Cheese" phantom on a tomotherapy machine. A set of cylindrical "Cheese" phantom was adopted for scanning with respectively pitch value (1, 2, 3 mm) with same number slice (10 slice), same length (approximately 9 cm) and phantom set-ups on the couch of tomotherapy system. The average MVCT imaging dose were measured using A1SL ion chamber inserted in the phantom with preset geometry. The MVCT scanning average dose for the cylindrical "Cheese" phantom was 2.24 cGy, 1.02 cGy, 0.81 cGy during respectively pitch value (pitch 1, 2, 3 mm) with same number slice (10 slice), and same length's average dose was 2.47 cGy, 1.28 cGy, 0.88 cGy respectively (pitch 1, 2, 3 mm). Two major parameters, the assigned pitch numbers and scanning length, where the most important impacts to the dose variation. The MVCT dose was inversely proportional to the CT pitch value. The results may provide a reliable guidance for proper planning design of the scanning region, which is valuable to help minimize the extra dose to patient. Questionnaires were distributed to Radiology departments at hospitals with 300 sickbeds throughout the Pohang region of North Gyeongsang Province concerning awareness and performance levels of infection control. The investigation included measurements of the pollution levels of imaging equipment and assistive apparatuses in order to prepare a plan for the activation of prevention and management of hospital infections. The survey was designed to question respondents in regards to personal data, infection management prevention education, and infection management guidelines.

Improvement of Rice Quality Using Grain Color Sorter During Early Transplanting Cultivation in the Southern Plain of Korea (색채선별기 이용한 남부평야지 조기재배 해담쌀의 품질향상)

  • Lee, Jong-Hee;Lee, Ji-Yoon;Lee, Somyeong;Shin, Dongjin;Cha, Jinkyeong;Cho, Jun-Hyeon;Kwon, Young-Ho;Jo, Su-min;Park, Dong-Soo
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.65 no.2
    • /
    • pp.79-83
    • /
    • 2020
  • A photoelectric grain color sorter is commonly used in postharvest technology to detect and separate grains considered to be of good quality from those of poor quality based on color. In this study, the milled rice of Haedamssal cultivated under early transplanting conditions was evaluated using the color sorting device. Rice was classified according to standard grades of 64% for grade A, 18% for grade B, and 17.2% for grade C. By head rice ratio analysis, the milled rice of Haedamssal was recorded a grade A of 72.9%, representing a 24.5% improvement compared to the 48.4% of original grains. However, the grades B and C of Haedamssal rice were lower than those of original rice. In addition, grade A whiteness of Haedamssal rice was 45.3, which was lower than that of original grains. The color affinity redness was significantly lower in Haedamssal rice than in the screening control. No significant difference was found in the amylose and protein contents of rice before and after selection by the grain color sorter. In contrast, grain viscosity analysis revealed an increase in peak and final viscosities, while the consistence viscosity increased in low grade levels. Our results suggest that the photoelectric grain color sorter could improve the head rice ratio and palatability of early transplanted Hadamssal rice.

Interaction Between TCP and MAC-layer to Improve TCP Flow Performance over WLANs (유무선랜 환경에서 TCP Flow의 성능향상을 위한 MAC 계층과 TCP 계층의 연동기법)

  • Kim, Jae-Hoon;Chung, Kwang-Sue
    • Journal of KIISE:Information Networking
    • /
    • v.35 no.2
    • /
    • pp.99-111
    • /
    • 2008
  • In recent years, the needs for WLANs(Wireless Local Area Networks) technology which can access to Internet anywhere have been dramatically increased particularly in SOHO(Small Office Home Office) and Hot Spot. However, unlike wired networks, there are some unique characteristics of wireless networks. These characteristics include the burst packet losses due to unreliable wireless channel. Note that burst packet losses, which occur when the distance between the wireless station and the AP(Access Point) increase or when obstacles move temporarily between the station and AP, are very frequent in 802.11 networks. Conversely, due to burst packet losses, the performance of 802.11 networks are not always as sufficient as the current application require, particularly when they use TCP at the transport layer. The high packet loss rate over wireless links can trigger unnecessary execution of TCP congestion control algorithm, resulting in performance degradation. In order to overcome the limitations of WLANs environment, MAC-layer LDA(Loss Differentiation Algorithm)has been proposed. MAC-layer LDA prevents TCP's timeout by increasing CRD(Consecutive Retry Duration) higher than burst packet loss duration. However, in the wireless channel with high packet loss rate, MAC-layer LDA does not work well because of two reason: (a) If the CRD is lower than burst packet loss duration due to the limited increase of retry limit, end-to-end performance is degraded. (b) energy of mobile device and bandwidth utilization in the wireless link are wasted unnecessarily by Reducing the drainage speed of the network buffer due to the increase of CRD. In this paper, we propose a new retransmission module based on Cross-layer approach, called BLD(Burst Loss Detection) module, to solve the limitation of previous link layer retransmission schemes. BLD module's algorithm is retransmission mechanism at IEEE 802.11 networks and performs retransmission based on the interaction between retransmission mechanisms of the MAC layer and TCP. From the simulation by using ns-2(Network Simulator), we could see more improved TCP throughput and energy efficiency with the proposed scheme than previous mechanisms.

The Study on the Medical and Nursing Service Needs of the Terminal Cancer Patients and Their Caregivers (말기암 환자와 가족의 의료 및 간호 서비스 요구)

  • 이소우;이은옥;허대석;노국희;김현숙;김선례;김성자;김정희;이경옥
    • Journal of Korean Academy of Nursing
    • /
    • v.28 no.4
    • /
    • pp.958-969
    • /
    • 1998
  • In this study, we attempted to investigate the needs and problems of the terminal cancer patients and their family caregivers to provide them with nursing information to improve their quality of life and prepare for a peaceful death. Data was collected from August 1, 1995 to July 31, 1996 at the internal medicine unit of S hospital in Seoul area with the two groups of participants who were family members of terminal cancer patients seventy four of them were in-patients and 34 were out-patients who were discharged from the same hospital for home care. The research tool used in this study has been developed by selecting the questionnaires from various references, modifying them for our purpose and refining them based on the results of preliminary study. While general background information about the patients was obtained by reviewing their medical records, all other information was collected by interviewing the primary family caregivers of the patients using the questionnaire. The data collected were analyzed with the SPSS PC/sup +/ program. The results of this study are summarized as follows ; 1) Most frequently complained symptoms of the terminal cancer patients were in the order of pain(87%), weakness(86.1%), anorexia(83.3%) and fatigue (80.6%). 2) Main therapies for the terminal cancer patients were pain control (58.3%), hyperalimentation(47.2%) and antibiotics(21.3%). 3) Special medical devices that terminal cancer patients used most were oxygen device (11.1%), and feeding tube(5.6%). Other devices were used by less than 5% of the patients. 4) The mobility of 70.4% of the patients was worse than ECOG 3 level, they had to stay in bed more than 50% of a day. 5) Patients wanted their medical staffs to help relieve pain(45.4%), various physical symptoms(29.6%), and problems associated with their emotion(11.1%). 6) 16.7% of the family caregivers hoped for full recovery of the patients, refusing to admit the status of the patients. Also, 37% wished for the extension of the patient's life at least for 6 months. 7) Only 38.9% of the family members was preparing for the patient's funeral. 8) 45.4% of family caregivers prefer hospital as the place for the patient's death, 39.8% their own home, and 14.8% undetermined. 9) Caregivers of the patients were mostly close family members, i.e., spouse(62%), and sons and daughters or daughter-in-laws(21.3%). 10) 43.5% of the family caregivers were aware of hospice care. 46.8% of them learned about the hospice care from the mass media, 27.7% from health professionals, and the rest from books and other sources. 11) Caregivers were asked about the most difficult problems they encounter in home care, 41 of them pointed out the lack of health professionals they can contact, counsel and get help from in case of emergency, 17 identified the difficulty of finding appropriate transportation to hospital, and 13 stated the difficulty of admission in hospital as needed. 12) 93.6% of family caregivers demanded 24-hour hot line, 80% the visiting nurses and doctors, and 69.4% the volunteer's help. The above results indicate that terminal patients and their family caregivers demand help from qualified health professionals whenever necessary. Hospice care system led by well-trained medical and nursing staffs is one of the viable answers for such demands.

  • PDF

Evaluation of the Clinical Usefulness of the Xeniss Rapid TB kit for the Diagnosis of Tuberculosis (결핵진단에서 Xeniss Rapid TB kit의 임상적 유용성)

  • Park, Seung-Kyu;Lee, Woo-Chul;Hwang, Soo-Hee;Kwon, Eun-Si;Lee, Hung-Soon;Lee, Duk-Hyoung
    • Tuberculosis and Respiratory Diseases
    • /
    • v.53 no.4
    • /
    • pp.389-400
    • /
    • 2002
  • Background : The rapid diagnostic tests for tuberculosis are needed to facilitate early treatment of tuberculosis and prevention of Mycobacterium tuberculosis transmission. The Xeniss Rapid TB kit is a rapid, card-based immunochromatographic test for the detection of antibodies directed against M. tuberculosis antigens including antigen 5(38-kDa antigen). The objective of this study was to evaluate the performance of the Xeniss Rapid TB kit for the diagnosis of active tuberculosis with serums from patients, asymptomatic healthy and close contact controls. Methods : 188 patients with active tuberculosis were tested; 177 with pulmonary tuberculosis(18 with combined pleurisy), and 11 with extrapulmonary tuberculosis. The control groups were composed of 82 close contacts and 57 healthy adults. Study subject were drawn from one national tuberculosis hospital for patients and close contacts, and another private hospital for healthy adults in Masan city, Korea. The Xeniss Rapid TB kit(Xeniss Life Science Co., Ltd., Seoul, Korea) was evaluated by using serum samples according to the instructions of the manufacturer by an investigator masked to the clinical and microbiological status of the study subjects. Results : The diagnostic sensitivity of the Xeniss Rapid TB kit was 73.9% in patients and specificities were 73.2% and 93.0% in close contact and healthy adults respectively. The positive predictive value in patients was 84.2% and the negative predictive value in controls was 85.8%. Conclusion : This study shows that the Xeniss Rapid TB test is a simple and fast method to diagnose active TB. The results of the sensitivity and specificites suggest that serodiagnosis using this point of care testing(POCT) device would be valuable and advantageous for screening tuberculosis in the clinical field.

The Usefulness of Serologic Diagnosis for Tuberculosis with Two Rapid Immunochromatographic Assay Devices (혈청학적 방법을 이용한 결핵 진단 방법의 효용성)

  • Kim, Deog-Kyeom;Kwon, Sung-Youn;Lee, Suk-Young;Park, Gye-Young;Jung, Kyung-Hae;Lee, Chun-Taek;Yoo, Churl-Gyoo;Kim, Young-Whan;Han, Sung-Koo;Shim, Yong-Soo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.47 no.5
    • /
    • pp.586-597
    • /
    • 1999
  • Background: Many diagnostic tests have developed to diagnose tuberculosis and other mycobacterial diseases but the diagnosis of tuberculosis relies largely on radiological findings and acid-fast staining of sputum and/or culture. Recently, new serologic diagnostic methods, which are safe and easy to use have been introduced into Korea. In this study, the usefulness of serologic diagnosis for tuberculosis and the disease pattern induced variation of the test were evaluated. Methods: Serological assay was performed upon 108 patients with two test kits, the ICT tuberculosis and the BioSign$^{TM}$TB, which are based upon a rapid immunochromatographic assay technique, capable of being interpreted within 15 minutes. The case groups consisted of 61 patients with active pulmonary tuberculosis(36 patients), extrapulmonary tuberculosis(3 patients), or both(22 patients). Control groups consisted of 47 patients with inactive old pulmonary tuberculosis(17 patients), nontuberculous pulmonary disease(16 patients) and nonpulmonary cardiac disease(14 patients). Results : The diagnostic sensitivity, specificity, positive predictive value(PPV) and negative predictive value(NPV) of the ICT tuberculosis were 64.3%, 91.5%, 90.0% and 68.3% respectively. The diagnostic sensitivity, specificity, PPV and NPV of the BioSign$^{TM}$TB were 76.5%, 95.3%, 94.1 % and 78.8% respectively. Differences in sensitivity were not significant between patients with previous history of tuberculosis or patients without prior history of tuberculosis. The ICT tuberculosis test showed higher sensitivity in pulmonary tuberculosis patients(76.5%) than extrapulmonary tuberculosis patients(33.3%). There was no difference in sensitivity between patients with or without cavitary lesion by chest X-ray. Conclusion: Considering high specificity and PPV, serologic diagnosis using a rapid immunochromatographic assay device is another helpful diagnostic method in the diagnosis of tuberculosis, when combined with previous diagnostic methods such as chest X-ray, microbiologic study but it has limitation in terms of confirming the diagnosis for tuberculosis as the only diagnostic method because of relatively low sensitivity and NPV.

  • PDF

Comparison for Glomerular Filtration Rate in Gamma Camera Systems Using Dynamic Renal Phantom System (동적신장팬텀시스템 개발에 따른 장비별 사구체여과율의 비교)

  • Kang, Chun Goo;Park, Hoon-Hee;Oh, Shin Hyun;Lee, Han Wool;Kim, Jung Yul;Oh, Joo Yung;Lee, Ju Young;Kim, Jae Sam;Lee, Chang Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.3-9
    • /
    • 2013
  • Purpose: Currently commercially available phantom can reproduce and evaluate only a static situation, the study is incomplete research on phantom and system which is can confirmed functional situation in the kidney by time through dynamic phantom and blood flow velocity, various difference according to the amount of radioactive. Therefore, through this study, it has produced the dynamic kidney phantom to reproduce images through the dynamic flow of the kidney, it desire to evaluate the usefulness of nuclear medicine imaging. Materials and Methods: The production of the kidney phantom was fabricated based on the normal adult kidney, in order to reproduce the dynamic situation based on the fabricated kidney phantom, in this study it was applied the volume pump that can adjust the speed of blood flow, so it can be integrated continuously radioactive isotopes in the kidney by using $^{99m}Tc-pertechnate$. Used the radioactive isotope was supplied through the two pump. It was confirmed the changes according to the infusion rate, radioactive isotopes and the different injection speeds on the left and right, analysis of the acquired images was done by drawn ten times ROI in order to check the reproducibility of each on the front and rear of the kidney and bladder. Results: Under the same conditions infusion rate 40 mL/min fixed to adjust the pressure of the pump when the radiopharmaceuticals between 2-3 minutes in the most integrated in the kidney phantom was excreted inthe bladder. Glomerular filtration rate (GFR), respectively, by each device SYMBIA 1,091 mL/min, FORTE 1,232 mL/min, ARGUS 1,264 mL/min, INFINIA 1,302 mL/min in that there isno statistically significant difference was found, Tmax values and T1/2 values stars from all equipment with no statistically significant difference was found. CV values of the coefficient of variation less than 5% was found to be repeatable, and to 2.67% of the lowest SYMBIA appeared, INFINIA was the highest in the 4.86%. Conclusion: Through this study, the results showed that the dynamic kidney phantom system is able to similarly reproduce renogram in the actual clinical. Especially, the depicted over time for the flow to be excreted through the kidney into the bladder was adequately reproduce, it is expected to be utilized as basic data to check the quality of the dynamic images. In addition, it is considered to help in the field of functional imaging and quality control.

  • PDF

A Study on Teaching-Learning and Evaluation Methods of Environmental Studies in the Middle School (중학교 "환경" 교과의 교수.학습 및 평가 방법 연구)

  • 남상준
    • Hwankyungkyoyuk
    • /
    • v.7 no.1
    • /
    • pp.1-17
    • /
    • 1994
  • This study was performed to determine appropriate teaching-learning and evaluation methods for Environmental Studies. To promote the relevance of our study to the needs of the schools and concerned educational communities of environmental education, we reviewed related literature, conducted questionnaire surveys, interviewed related teachers and administrator, held meetings with experts, and field-tested our findings. For selecting and developing teaching-learning methods of Environmental Studies, findings of educational research in general are considered. moreover, principles of environmental education, general aim of environmental education, orientations of environmental education, and developmental stages of middle school students in educational psychology were attended. In addition, relevance to the purpose of the Environmental Studies curriculum, appropriateness for value inquiry as well as knowledge inquiry, small group centered class organization, social interaction centered teaching-learning process, regional environmental situation, significance of personal environment, evaluation methods of Environmental Studies, multi- and inter-disciplinary contents of the Environmental Studies textbook, suitability to the evaluation methods of Environmental Studies, and emphasis on the social interaction in teaching-learning process were regarded. It was learned the Environmental Studies can be taught most effectively in via of holding discussion sessions, conducting actual investigation, doing experiment-practice, doing games and plate, role-playing and carrying out simulation activities, and doing inquiry. These teaching-learning methods were field-tested and proved appropriate methods for the subject. For selecting and developing evaluation method of Environmental Studies, such principles and characteristics of Environmental Studies as objective domains stated in the Environmental Studies curriculum, diversity of teaching-learning organization, were appreciated. We categorized nine evaluation methods: the teacher may conduct questionnaire surveys, testings, interviews, non-participatory observations; they may evaluate student's experiment-practice performances, reports preparation ability, ability to establish a research project, the teacher may ask the students to conduct a self-evaluation, or reciprocal evaluation. To maximize the effect of these methods, we further developed an application system. It considered three variables, that is, evaluates, evaluation objectives domains, and evaluation agent, and showed how to choose the most appropriate methods and, when necessary, how to combine uses of different methods depending on these variables. A sample evaluation instrument made on the basis of this application system was developed and tested in the classes. The system proved effective. Pilot applications of the teaching-learning methods and evaluation method were made simultaneously; and the results and their implications are as follows. Discussion program was applied in a lesson dealing with the problems of waste disposal, in which students showed active participation and creative thinking. The evaluation method used in this lesson was a multiple-choice written test for knowledge and skills. It was shown that this evaluation method and device are effective in helping students' revision of the lesson and in stimulating their creative interpretations and responces. Pupils showed great interests in the actual investigation program, and this programme was proved to be effective in enhancing students' participation. However, it was also turned out that there must be pre-arranged plans for the objects, contents and procedures of survey if this program is to effective. In this lesson, non-participatory observation methods were used with a focus on the attitudes of students. A scaled reported in general description rather than in grade. Experiment-practice programme was adopted in a lesson for purifying contaminated water and in this lesson, instruction objectives were properly established, the teaching-learning process was clearly specified and students were highly motivated. On the other hand, however, it was difficult to control the class when some groups of students require more times to complete their experiment, and sometimes different results. As regards to evaluation, performance observation test were used for assessing skills and attitudes. If teachers use well-prepared Likert scale, evaluation of all groups within a reasonablely short period of time will be possible. The most effective and successful programme in therms of students' participation and enjoyment, was the 'ah-nah-bah-dah-market' program, which is kind of game of the flea market. For better organized program of this kind, however, are essential, In this program, students appraise their own attitudes and behavior by responding to a written questionnaire. In addition, students were asked to record any anecdotes relating to self-appraisal of changes on one's own attitudes and behaviours. Even after the lesson, students keep recording those changes on letters to herself. Role-playing and simulation game programme was applied to a case of 'NIMBY', in which students should decide where to located a refuse dumping ground. For this kind of programme to e successful, concepts and words used in the script should be appropriate for students' intellectual levels, and students should by adequately introduced into the objective and the procedures of the lessons. Written questionnaire was used to assess individual students' attitudes after the lesson, but in order to acquire information on the changes of students' attitudes and skills, pre-test may have to be made. Doing inquiry programme, in which advantages in which students actually investigated the environmental influence of the areas where school os located, had advantages in developing students' ability to study the environmental problems and to present the results of their studies. For this programme to be more efficient, areas of investigation should be clearly divided and alloted to each group so that repetition or overlap in areas of study and presentation be avoided, and complementary wok between groups bee enhanced. In this programme, teacher assessed students' knowledge and attitudes on the basis of reports prepared by each group. However, there were found some difficults in assessing students' attitudes and behaviours solely on the grounds of written report. Perhaps, using a scaled checklist assessing students' attitudes while their presentation could help to relieve the difficulties.

  • PDF

Trend and future prospect on the development of technology for electronic security system (기계경비시스템의 기술 변화추세와 개발전망)

  • Chung, Tae-Hwang;So, Sung-Young
    • Korean Security Journal
    • /
    • no.19
    • /
    • pp.225-244
    • /
    • 2009
  • Electronic security system is composed mainly of electronic-information-communication device, so system technology, configuration and management of the electronic security system could be affected by the change of information-communication environment. This study is to propose the future prospect on the development of technique for electronic security system through the analysis of the trend and the actual condition on the development of technique. This study is based on literature study and interview with user and provider of electronic security system, also survey was carried out by system provider and members of security integration company to come up with more practical result. Hybrid DVR technology that has multi-function such as motion detection, target tracking and image identification is expected to be developed. And 'Embedded IP camera' technology that internet server and image identification software are built in. Those technologies could change the configuration and management of CCTV system. Fingerprint identification technology and face identification technology are continually developed to get more reliability, but continual development of surveillance and three-dimension identification technology for more efficient face identification system is needed. As radio identification and tracking function of RFID is appreciated as very useful for access control system, hardware and software of RFID technology is expected to be developed, but government's support for market revitalization is necessary. Behavior pattern identification sensor technology is expected to be developed and could replace passive infrared sensor that cause system error, giving security guard firm confidence for response. The principle of behavior pattern identification is similar to image identification, so those two technology could be integrated with tracking technology and radio identification technology of RFID for total monitoring system. For more efficient electronic security system, middle-ware's role is very important to integrate the technology of electronic security system, this could make possible of installing the integrated security system.

  • PDF

Evaluation of Temperature and Humidity of a Thermo-Hygrostat of PET/CT Equipment using a Temperature and Humidity Sensor(BME 280) (온·습도센서(BME 280 센서)를 이용한 PET/CT 장비의 항온 항습기 온·습도 평가)

  • Ryu, Chan-Ju;Kim, Jeong-A;Kim, Jun-Su;Yun, Geun-Yeong;Heo, Seung-Hui;Hong, Seong-Jong
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.1
    • /
    • pp.15-22
    • /
    • 2020
  • PET(Positron Emission Tomography) devices are used as PET/CT or PET/MRI devices fused with the devices of CT or MRI for obtaining anatomical information. Therefore, the devices are constructed in circular ring-type structure whose length of gantry(the main part of filming) becomes wider and the interior depth becomes longer in comparison to other common medical equipments. scintillator, one of the components in PET devices, is inside the gantry, and as it is consisted of crystal which is sensitive to the change of temperature and humidity, large temperature change can cause the scintillator to be damaged. Though scintillator located inside the gantry maintains temperature and humidity with a thermo-hygrostat, changes in temperature and humidity are expected due to structural reasons. The output value was measured by dividing the inside of the gantry of the PET/CT device into six zones, each of which an Adafruit BME 280 temperature and humidity sensor was placed at. A thermo-hygrostat keeps the temperature and humidity constant in the PET/CT room. As the measured value of temperature and humidity of the sensor was obtained, the measured value of temperature and humidity appeared in the thermohygrostat was taken at the same time. Comparing the average measured values of temperature and humidity measured at each six zones with the average values of the thermo-hygrostat results in a difference of 2.71℃ in temperature and 21.5% in humidity. The measured temperature and humidity of PET Gantry is out of domestic quality control range. According to the results of the study, if there is continuous change in temperature and humidity in the future, the aging of the scintillator mounted in the PET Gantry is expected to be aging, so it is necessary to find a way to properly maintain the temperature and humidity inside the Gantry structure.