• Title/Summary/Keyword: Control and Monitoring system

Search Result 2,947, Processing Time 0.032 seconds

Design and Implementation of DCS Terminal Remote Monitoring Board using Wire and Wireless Communication (유무선 통신을 이용한 DCS 터미널 원격 감시 보드 설계 및 구현)

  • KPark, Hae-Dong;Kang, Jeon-Wook;Kim, Jae-Hwan;Lee, Se-Hoon
    • KSCI Review
    • /
    • v.14 no.2
    • /
    • pp.117-122
    • /
    • 2006
  • In this paper, we designed and implemented the DCS(Distributed Control System) terminal remote monitoring board for build total unified management system based wireless communication on automatic control system fields. Also, it tested and evaluated for check an usability and performance. The board monitored relay and fuse status at power management room real-time. Therefore, we expected economic effects extend relay life-time that pre-detected errors and prevented relay fault.

  • PDF

A Study on an Implementation of Control Panel of Sun Trackers and Monitoring System for Photovoltaic Generation Plants (태양광발전의 태양추적기제어반 및 모니터링시스템 구현에 관한 연구)

  • Lho, Tae-Jung;Park, Min-Yong;Lee, Seung-Hyeon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.9
    • /
    • pp.3161-3167
    • /
    • 2010
  • Hall sensors of BLDC(brushless DC) motor are used to detect a position information for a control mechanism, which implements an algorithm for velocity and position control. Actual azimuth and altitude were measured to evaluate a control precision. The measurement revealed comparatively good accuracy that the measured values were $2.02^{\circ}$ and $1.01^{\circ}$ respectively, and the maximum error falls within $1.86^{\circ}$. The developed monitoring system of photovoltaic generation plants is a LCU(Local Control Unit) based on an integrated monitoring system which supports 1:N method for multiple simultaneous connections, remote control and real-time system state monitoring.

A Case Study on the Field Monitoring of the Deep Rock Excavation Site in Urban Area on Severe Unbalanced Pressure Condition (편토압이 심한 도심지 대심도 암반굴착공사에서의 계측사례)

  • Kim, Tae-Seob;Kim, Woong-Kyu;Jung, Chang-Won;Han, Chul-Hee
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.10a
    • /
    • pp.1259-1267
    • /
    • 2008
  • One of the most important item for insuring the stability of ground in urban deep excavation site near by major structure such as subway is displacement control of earth retaining wall. The field monitoring system is classified by two types as manual system and automatic system. The application case of latter type of field monitoring is increased because real time measurement is possible in automatic system and that is correspondent with the recent constructional trend. Though the automatic monitoring system is more useful and advanced than manual monitoring system, accuracy of the system is not verified sufficiently. It was examined that the reliance of automatic monitoring system in this paper through the comparison of monitoring result obtained one of deep urban excavation site in which the each type of monitoring system was executed concurrently. Result of the examination is that the two types of monitoring system is generally alike in view of monitoring result, so the engineering reliance of automatic system was confirmed in case site. This study was researched in restricted one case site, so it is expected more precise analysis from security of more data monitored and progressive study.

  • PDF

Implementation of Real-time Monitoring and Remote Control System Testbed based on Digital Twin (디지털 트윈을 활용한 실시간 모니터링 및 원격제어 시스템의 테스트베드 구현)

  • Yoon, Jung-Eun;Kim, Won-Suk
    • Journal of Korea Multimedia Society
    • /
    • v.25 no.2
    • /
    • pp.325-334
    • /
    • 2022
  • Digital twin has the advantages of quality improvement and cost reduction, so it is widely applied to various industries. In this paper, a method to implement the major technologies of digital twin easily and quickly is presented. These include data management and relay servers, real-time monitoring applications including remote control interfaces, and direct connection protocols for video streaming. In addition, an algorithm for controlling a two-wheeled vehicle with a 2D interface is also proposed. The implemented system performs near real-time synchronization between the real environment and the virtual space. The delay time that occurs in remote control of the vehicle in the real environment was compared with the results of applying the proposed delay time reduction method. In addition, in the case of 2D interface-based control, an algorithm that can guarantee the user experience was implemented and applied to the actual environment and verified through experiments.

Development of Long-Term Storage Technology for Chinese Cabbage - Physiological Characteristics of Postharvest Freshness in a Cooler with a Monitoring and Control Interface

  • Lim, Ki Taek;Kim, Jangho;Chung, Jong Hoon
    • Journal of Biosystems Engineering
    • /
    • v.39 no.3
    • /
    • pp.194-204
    • /
    • 2014
  • Purpose: The aim of this study was to develop long-term storage technology for Chinese cabbage in order to extend the period of availability of freshly harvested products. The scope of the paper deals with the use of a cooler with a remote monitoring and control interface in conjunction with use of packaging film. Methods: A cooler with a real time monitoring system was designed as a low-temperature storage facility to control temperature and relative humidity (RH). The effects of storage in high-density polyethylene (HDPE) plastic boxes, 3% chitosan dipping solution, polypropylene film (PEF) with perforations, and mesh packaging bags on physiological responses were investigated. The optimal storage temperature and humidity for 120 days were below $0.5^{\circ}C$ and 90%, respectively. Physiological and biochemical features of cabbage quality were also analyzed: weight loss, texture, and sugar salinity, chlorophyll, reducing sugar, and vitamin C contents. Results: The cooler with a remote monitoring and control interface could be operated by an HMI program. A $0.5^{\circ}C$ temperature and 90% humidity could be remotely controlled within the cooler for 120 days. Postharvest freshness of Chinese cabbages could be maintained up to 120 days depending on the packaging method and operation of the remote monitoring system. In particular, wrapping the cabbages in PEF with perforations resulted in a less than a 5% deterioration in quality. This study provides evidence for efficient performance of plastic films in minimizing post-harvest deterioration and maintaining overall quality of cabbages stored under precise low-temperature conditions with remote monitoring and a control interface. Conclusions: Packaging with a modified plastic film and storage in a precisely controlled cooler with a remote monitoring and control interface could slow down the physiological factors that cause adverse quality changes and thereby increase the shelf life of Chinese cabbage.

Implementation of Monitoring and Control System for Fire Engine Pump using the AJAX (AJAX를 이용한 소방엔진펌프의 모니터링과 제어 시스템 구현)

  • Yang, Oh;Lee, Heon-Guk
    • Journal of the Semiconductor & Display Technology
    • /
    • v.15 no.3
    • /
    • pp.40-45
    • /
    • 2016
  • In this paper, the fire engine pump is controlled and monitored by the AJAX (Asynchronous Javascript and Xml) in the web server. The embedded system with built-in system having a processor and a memory of high performance occurs many problems in transmitting the large amount of data in real time through the web server. The AJAX is different from HTML (Hyper Text Makeup Language) with java script technology and can make RIA (Rich Internet Application). It process the necessary data by using asynchronous and it take advantage of usefulness, accessibility, a fast response time. Using AJAX can build up web server with real time and monitoring that fire engine pump status, check processing pump memory in the event of fire, also remotely monitors can do. The web server system can control the fire engine pump as like the black box. The experimental results show the effectiveness and commercialize possibility.

Web-based Building Automation System using Embedded Linux (임베디드 리눅스를 이용한 웹 기반 빌딩자동화시스템)

  • 신은철;이수영;최병욱
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.10 no.4
    • /
    • pp.334-340
    • /
    • 2004
  • In this paper, a Web-based management system for the building network is described. A multi-protocol converter based on SoC and embedded Linux is designed. The open source licensing, reliability, and broad hardware support are key reasons for use of embedded Linux in embedded industry. The multi-protocol converter integrates control network of RS-485 and LonWorks devices through TCP/IP protocol for a client with Java applet. The system consists of three-tier architecture, such as a client, a server that is performed on a multi-protocol converter, and control devices. The developed system includes the inverter motor control system with modbus protocol for the RS-485 network. The experiment results show that the multi-protocol converter using embedded Linux is a flexible and effective way to builda Web -based monitoring and control system.

A study on the Internet control and monitoring system using a microprocessor embedded controller (마이크로프로세서를 이용한 인터넷 원격감시제어 시스템에 관한 연구)

  • 서인호;문복산;김경엽;김영일;천행춘;유영호
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.152-156
    • /
    • 2000
  • Many industrial equipments use RS-232C interface. But Ethernet using CSMA/CD was widly spread recently. This interface is not compatible with RS-232C and requires PC based system. So In this Paper, We decribe a Internet control and monitoring system that control and watch plants without PC. We developed IP controller consisted of microprocessor and NIC and monitoring system using VC++ and SQL database. The protocol used this system is UDP/IP because it is applicable for real time system.

  • PDF

Simulator for Monitoring the Operations of Range Extender Electric Vehicles

  • Chun, Tae-Won;Tran, Quang-Vinh;Lee, Hong-Hee;Kim, Heung-Geun;Nho, Eui-Cheol
    • Journal of Power Electronics
    • /
    • v.11 no.4
    • /
    • pp.424-429
    • /
    • 2011
  • In this paper, the simulator of an on-line monitoring system for the range extender electric vehicle has been developed. The messages from the four control modules, the air pressure and fuel level sensors data, and the on/off switching states of 31 indicator lamps can be received through the control area network (CAN), and displayed on the graphic panel. The simulator was designed using the four DSP boards, variable resistors, and toggle switches instead of the four control modules, sensors, and switching state of indicator lamps on an actual series hybrid electric vehicle (SHEV) bus, respectively. The performance of the monitoring technologies was verified with the simulator at the laboratory, and then it was tested on an actual SHEV bus. The simulator is very useful at the initial development of the monitoring system at the hybrid-type or electrical vehicles.

Web based control modules Using LonWorks/Ethernet Server for Control a large Scale Renewable Energy System in Building (빌딩용 신.재생에너지시스템 제어를 위한 LonWorks기반 원격 제어모듈 개발)

  • Hong, Wonl-Pyo
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1706-1711
    • /
    • 2008
  • This paper proposes a new Web based-control concept & design method and implementation of LonWorks network system for a large scale renewable energy energy control and monitoring system in building. The Experimental LonWorks network system using LonWorks/Ethernet(Web) server is designed and fabricated. This article addresses issues in architecture of LonWorks/Ethernet sever, embedded processors architecture for converting LonTalks protocol to Modbus protocol and software, and Internet technologies. It is also verified that the multi-induction motor control and monitoring system using LonWorks/Ethernet server have available, interoperable, reliable performance characteristics from the experimental results, Especially, The seamless integration of TCP/IP networks with control networks allows access to any control point from anywhere. Thus, the results provide a available technical data for remote distributed control system of industrial and buildings field.

  • PDF