• Title/Summary/Keyword: Control accuracy

Search Result 4,384, Processing Time 0.039 seconds

A Hybrid Forecasting Framework based on Case-based Reasoning and Artificial Neural Network (사례기반 추론기법과 인공신경망을 이용한 서비스 수요예측 프레임워크)

  • Hwang, Yousub
    • Journal of Intelligence and Information Systems
    • /
    • v.18 no.4
    • /
    • pp.43-57
    • /
    • 2012
  • To enhance the competitive advantage in a constantly changing business environment, an enterprise management must make the right decision in many business activities based on both internal and external information. Thus, providing accurate information plays a prominent role in management's decision making. Intuitively, historical data can provide a feasible estimate through the forecasting models. Therefore, if the service department can estimate the service quantity for the next period, the service department can then effectively control the inventory of service related resources such as human, parts, and other facilities. In addition, the production department can make load map for improving its product quality. Therefore, obtaining an accurate service forecast most likely appears to be critical to manufacturing companies. Numerous investigations addressing this problem have generally employed statistical methods, such as regression or autoregressive and moving average simulation. However, these methods are only efficient for data with are seasonal or cyclical. If the data are influenced by the special characteristics of product, they are not feasible. In our research, we propose a forecasting framework that predicts service demand of manufacturing organization by combining Case-based reasoning (CBR) and leveraging an unsupervised artificial neural network based clustering analysis (i.e., Self-Organizing Maps; SOM). We believe that this is one of the first attempts at applying unsupervised artificial neural network-based machine-learning techniques in the service forecasting domain. Our proposed approach has several appealing features : (1) We applied CBR and SOM in a new forecasting domain such as service demand forecasting. (2) We proposed our combined approach between CBR and SOM in order to overcome limitations of traditional statistical forecasting methods and We have developed a service forecasting tool based on the proposed approach using an unsupervised artificial neural network and Case-based reasoning. In this research, we conducted an empirical study on a real digital TV manufacturer (i.e., Company A). In addition, we have empirically evaluated the proposed approach and tool using real sales and service related data from digital TV manufacturer. In our empirical experiments, we intend to explore the performance of our proposed service forecasting framework when compared to the performances predicted by other two service forecasting methods; one is traditional CBR based forecasting model and the other is the existing service forecasting model used by Company A. We ran each service forecasting 144 times; each time, input data were randomly sampled for each service forecasting framework. To evaluate accuracy of forecasting results, we used Mean Absolute Percentage Error (MAPE) as primary performance measure in our experiments. We conducted one-way ANOVA test with the 144 measurements of MAPE for three different service forecasting approaches. For example, the F-ratio of MAPE for three different service forecasting approaches is 67.25 and the p-value is 0.000. This means that the difference between the MAPE of the three different service forecasting approaches is significant at the level of 0.000. Since there is a significant difference among the different service forecasting approaches, we conducted Tukey's HSD post hoc test to determine exactly which means of MAPE are significantly different from which other ones. In terms of MAPE, Tukey's HSD post hoc test grouped the three different service forecasting approaches into three different subsets in the following order: our proposed approach > traditional CBR-based service forecasting approach > the existing forecasting approach used by Company A. Consequently, our empirical experiments show that our proposed approach outperformed the traditional CBR based forecasting model and the existing service forecasting model used by Company A. The rest of this paper is organized as follows. Section 2 provides some research background information such as summary of CBR and SOM. Section 3 presents a hybrid service forecasting framework based on Case-based Reasoning and Self-Organizing Maps, while the empirical evaluation results are summarized in Section 4. Conclusion and future research directions are finally discussed in Section 5.

Simultaneous Determination of 8 Preservatives (6 Parabens, 2-Phenoxyethanol, and Chlorphenesin) in Cosmetics by $UPLC^{TM}$ ($UPLC^{TM}$를 이용한 화장품 중 보존제 8종(파라벤 6종, 페녹시에탄올, 클로페네신)의 동시분석)

  • Park, Jeong-Eun;Lee, So-Mi;Jeong, Hye-Jin;Chang, Ih-Seop
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.33 no.4
    • /
    • pp.263-267
    • /
    • 2007
  • Parabens are used in nearly all types of cosmetics and toiletries because they are formulated well and have broad spectrum of activity, interness, low costs and excellent chemical stability in relation to pH. 2-phenoxyethanol and chlorphenesin are common preservatives which are usually used in combination with parabens in cosmetics. Toxicity of parabens is generally low but application of parabens to damaged or broken skin has resulted in sensitization. Moreover, the possibility of their estrogenic potential, anesthetic effects and reproductive toxicity has been reported. Consequently there are some regulations in use of parabens. And the maximum permitted concentrations of chlorphenesin and 2-phenoxyethanol in cosmetic products are authorized by the same reasons. So it is important to control and estimate the amount of parabens in products. In this article, we proposed a valid method for the simultaneous determination of 8 preservatives including parabens in a short time using ultra performance liquid $chromatography^{TM}\;(UPLC^{TM})$. Separation of eight components was achieved in less than 10 min and resolutions were reasonable (USP resolution ${\geqq}\;2$). And limit of detection and quantification were evaluated. The method was suitably validated for specificity, linearity, precision (repeatability, intermediate precision) and accuracy for assay (recovery) based on International conference on harmonisation (ICH) guideline. The method was applicable to analysis of preservatives in cosmetic products.

Serum Beta-2 Microglobulin: a Possible Marker for Disease Progression in Egyptian Patients with Chronic HCV Related Liver Diseases

  • Ouda, SM;Khairy, AM;Sorour, Ashraf E;Mikhail, Mikhail Nasr
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.17
    • /
    • pp.7825-7829
    • /
    • 2015
  • Background: Egypt has the highest prevalence of HCV infection in the world (~14.7%). Around 10-15% of HCV-infected persons will advance to cirrhosis within the first 20 years. The incidence of HCC is expected to grow in the next two decades, largely due to HCV related cirrhosis, and detection of HCC at an early stage is critical for a favorable clinical outcome. No simple reliable non-invasive marker has been available till now. B2M, a non-glycosylated polypeptide composed of 99 amino acids, is one of the components of HLA class I molecules on the surfaces of all nucleated cells. It has been reported that the level of serum B2M is elevated in patients with chronic hepatitis C and HCV-related HCC when compared to HCV-negative patients or healthy donors. Determining the clinical utility of serum B2M as a marker for disease progression in Egyptian patients with HCV related chronic hepatitis, cirrhosis and hepatocellular carcinoma was the aim of the present study. Materials and Methods: In this analytical cross sectional study 92 participants were included in 4 equal groups: Group (1) non cirrhotic chronic HCV; Group (2) HCV related liver cirrhosis; Group (3) HCC on top of HCV,; and Group (4) healthy controls. History taking, clinical examination, routine labs and abdominal ultrasound were conducted for all patients, PCR and Metavir scores for group (1) patients, and triphasic CT abdomen and AFP for Group (3) patients. B2M levels were measured in serum with a fully-automated IMX system. Results: The mean serum B2M level of Group (1) was $4.25{\pm}1.48{\mu}g/ml$., Group (2) was $7.48{\pm}3.04$, Group (3) was $6.62{\pm}2.49$ and Group (4) was $1.62{\pm}0.63$. Serum B2M levels were significantly higher in diseased than control group (p<0.01) being significantly higher in cirrhosis ($7.48{\pm}3.04$) and HCC groups ($6.62{\pm}2.49$) than the HCV group ($4.25{\pm}1.48$) (p<0.01). There was a significant correlation between B2M Level and ALK, total and direct bilirubin and INR (p<0.05), and a significant inverse correlation between B2M level and albumin, total proteins, HB andWBCS values (p<0.05). There was no significant correlation between B2M level and viral load or Metavir score, largest tumour size or AFP (p>0.05). The best B2M cut-off for HCV diagnosis was 2.6 with a sensitivity of 100%, a specificity of 92%, a positive predictive value (PPV) of 97% and a negative predictive value (NPV) of 100%. The best B2M cut-off for HCC diagnosis was 4.55 which yielded sensitivity, specificity, positive predictive value, negative predictive values of 74%, 62%, 39.5, 87.8% respectively (p-value <0.01) while best cut-off for cirrhosis was 4.9, with sensitivity 74 % and specificity 74%.The sensitivity for HCC diagnosis increased upon B2M and AFP combined estimation to 91%, specificity to 79%, NPV to 95% and accuracy to 83%. Conclusions: Serum B2M level is elevated in HCV related chronic liver diseases and may be used as a marker for HCV disease progression towards cirrhosis and carcinoma.

Comparison of marginal and internal fit of zirconia abutments with titanium abutments in internal hexagonal implants (내부육각 연결형 임플란트에서 지르코니아 지대주와 티타늄 지대주의 변연 및 내면 적합도의 비교)

  • Kim, Young-Ho;Cho, Hye-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.2
    • /
    • pp.93-102
    • /
    • 2016
  • Purpose: The aim of this study was to evaluate the fit accuracy of two zirconia and titanium abutments in internal hexagonal implants. Materials and methods: One titanium abutment and two zirconia abutments were tested in internal hexagonal implants (TSV, Zimmer). Prefabricated zirconia abutments (ZirAce, Acucera) and customized zirconia abutments milled by the Zirkonzahn system (Zirkonzahn Max, Zirkonzahn) were selected and prefabricated titanium abutments (Hex-Lock, Zimmer) were used as a control. Eight abutments per group were connected to implants with 30 Ncm torque. The marginal gaps at abutment-implant interface, the internal gaps at internal hex, vertical and horizontal gaps between screws and screw seats in abutments were measured after sectioning the embedded specimens using a scanning electron microscope. Data analysis included one-way analysis of variance and the Scheffe test (n=16, ${\alpha}=0.05$). Results: The mean marginal gap of customized zirconia abutment was higher than those of two prefabricated zirconia and titanium abutments. The internal gaps at internal hex showed no significant differences between customized and prefabricated abutments and were higher than those of prefabricated titanium abutments. The mean vertical and horizontal gaps at screw in prefabricated zirconia abutment were higher than those of prefabricated titanium abutment. In the case of customized zirconia abutment, the mean horizontal gap at screw was higher than those of both the prefabricated zirconia and the titanium abutment but the mean vertical gap was not even measureable. The screw seats were clearly formed but did not match with abutment screws in prefabricated zirconia abutments. They were not, however, precisely formed in the case of customized zirconia abutments. Conclusion: Within the limitations of this study, the prefabricated titanium abutments showed better fit than the zirconia abutments, regardless of customized or prefabricated. Also, the customized zirconia abutments showed significantly higher marginal gaps and the fit was less accurate between screws and screw seats than the prefabricated abutments, titanium and zirconia.

Application of Modified Mupit for the Recurrent Vulva Cancer in Brachytherapy (재발한 Vulvar 종양의 근접치료 시 Modified Mupit Applicator의 적용)

  • Kim, Jong-Sik;Jung, Chun-Young;Oh, Dong-Gyoon;Song, Ki-Won;Park, Young-Hwan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.18 no.1
    • /
    • pp.13-19
    • /
    • 2006
  • Purpose: To evaluate whether modified MUPIT applicator can effectively eradicate recurrent tumor in uterine cervix cancer and reduce rectal complication after complete radiation treatment. Materials and Methods: Modified MUPIT applicator basically consists of an acrylic cylinder with flexible brain applicator, an acrylic template with a predrilled array of holes that serve as guides for interstitial needles and interstitial needles. CT scan was peformed to determine tumor volume and the position of interstitial needles. Modified MUPIT applicator was applied to patient in operation room and the accuracy for position of interstitial needles in tumor volume was confirmed by CTscan. Brachytherapy was delivered using modified MUPIT applicator and RALS(192-lr HDR) after calculated computer planning by orthogonal film. The daily dose was 600cGy and the total dose was delivered 3,000 cGy in tumor volume by BID. Rectal dose was measured by TLD at 5 points so that evaluated the risk of rectal complication. Results: The application of modified MUPIT applicator improved dramatically dose distributions in tumor volume and follow-up of 3 month for this patient was clinically partial response without normal tissue complication, Rectal dose was measured 34.1 cGy, 57.1 cGy, 103.8 cGy, 162.7 cGy, 165.7 cGy at each points, especially the rectal dose including previous EBRT and ICR was 34.1 cGy, 57.1 cGy. Conclusion: Patients with locally recurrent tumor in uterine cervix cancel treated with modified MUPIT applicator can expect reasonable rates of local control. The advantages of the system are the fixed geometry provided by the template and cylinders. and improved dose distributions in irregular tumor volume without rectal complication.

  • PDF

Simultaneous HPLC Determination of Marker Compounds for the Standardization of Hedyotis diffusa (백운풀의 지표성분 설정 및 품질표준화를 위한 정량 분석법)

  • Bang, Han-Yeol;Yang, Eun-Ju;Kim, Jeong-Ah;Song, Kyung-Sik
    • Journal of Life Science
    • /
    • v.23 no.8
    • /
    • pp.1025-1031
    • /
    • 2013
  • From a 95% ethanolic extract of H. diffusa, four marker compounds (HD1~HD4) were isolated, which were relatively unique and exist in comparably high contents. The structures of marker compounds were identified as digitolutein (1), 2-hydroxy-3-methylanthraquinone (2), (E/Z)-6-O-p-coumaroyl scandoside methyl ester (4:1 mixture) (3), and (E/Z)-6-O-p-methoxycinnamoyl scandoside methyl ester (4:1 mixture) (4), respectively, on the basis of $^{13}C$ and $^1H$-NMR analyses. The calibration curves of marker compounds showed high linearity, as their correlation coefficient ($R^2$) were in the range of 0.9991~0.9999. In addition, the limit of detection (LOD) and the limit of quantification (LOQ) were $0.03{\sim}0.07{\mu}g/ml$ and $0.099{\sim}0.231{\mu}g/ml$, respectively. The intra-day/inter-day precision and accuracy were 0.23~2.00%/0.25~1.16% and 94.60~108.44%/94.73-110.23%, respectively. The optimal HPLC conditions for the simultaneous quantification of HD1~HD4 were as follows: stationary phase; Merck Chromolith RP-18e ($100{\times}4.6mm$, $5{\mu}m$), column temp.; room temperature, UV detection at 280 nm, flow rate; 2.0 ml/min, injection volume; $10{\mu}l$, mobile phase; start with the mixture of 80% solvent A ($H_2O$ containing 0.5% acetic acid) and 20% solvent B (methanol containing 0.5% acetic acid) and gradually decrease solvent A to 40% in 9 min., then retain this condition to 18 min. Under the HPLC condition, the four marker compounds 1~4 were successfully separated without any interference of other constituents. The results obtained in this study are expected to be helpful for the development of nutraceutics and natural medicines and for the quality control of this plant.

Determination of Sulfur Requirement to Adjust pH of Alkaline Soil by Buffer Curve Method (알칼리성 토양 pH 교정시 완충곡선법을 이용한 황 시용량 결정)

  • Lee, In-Bog;Lim, Jae-Hyun;Yiem, Myoung-Soon
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.33 no.6
    • /
    • pp.405-415
    • /
    • 2000
  • To determine application rate of elemental sulfur to adjust pH of alkaline soil, buffer curve method was investigated. The elemental sulfur required to control pH 8.3 to pH 6.3 by buffer curve calculation was treated in two soils of silty loam and sandy loam, and the sulfur-mixed soils were moistened with 50% of water holding capacity during incubation of 6 weeks at $30^{\circ}C$. Soil pH was lowered with incubation and reached to target point after 4 weeks of incubation, and elemental sulfur was oxidised entirely to sulfate. This means that buffer curve has the accuracy to determine sulfur application rate in alkaline soil. However it is estimated that application rate of sulfur should be carefully determined in the field scale. Excess application of elemental sulfur resulted in extremely low soil pH and caused the hinderance of lettuce growth by nutritional imbalance and ion toxicity. To simplify the determination procedure of sulfur requirement, buffer curve method by addition of 0.1N-HCl solution as unit of mL was developed, it was compared with theroutine methods which diluted $H_2SO_4$ solution and $Ca(OH)_2$ are added as cmolc per kg soil to adjust each pH step. Buffer capacities, cmolc kg $soil^{-1}$ $pH^{-1}$, calculated from two buffer curves were not significantly different. The result indicates that buffer curve method by 0.1N-HCl can be used to adjust high pH of alkaline soil.

  • PDF

Development of a Small Gamma Camera Using NaI(T1)-Position Sensitive Photomultiplier Tube for Breast Imaging (NaI (T1) 섬광결정과 위치민감형 광전자증배관을 이용한 유방암 진단용 소형 감마카메라 개발)

  • Kim, Jong-Ho;Choi, Yong;Kwon, Hong-Seong;Kim, Hee-Joung;Kim, Sang-Eun;Choe, Yearn-Seong;Lee, Kyung-Han;Kim, Moon-Hae;Joo, Koan-Sik;Kim, Byuug-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.4
    • /
    • pp.365-373
    • /
    • 1998
  • Purpose: The conventional gamma camera is not ideal for scintimammography because of its large detector size (${\sim}500mm$ in width) causing high cost and low image quality. We are developing a small gamma camera dedicated for breast imaging. Materials and Methods: The small gamma camera system consists of a NaI (T1) crystal ($60 mm{\times}60 mm{\times}6 mm$) coupled with a Hamamatsu R3941 Position Sensitive Photomultiplier Tube (PSPMT), a resister chain circuit, preamplifiers, nuclear instrument modules, an analog to digital converter and a personal computer for control and display. The PSPMT was read out using a standard resistive charge division which multiplexes the 34 cross wire anode channels into 4 signals ($X^+,\;X^-,\;Y^+,\;Y^-$). Those signals were individually amplified by four preamplifiers and then, shaped and amplified by amplifiers. The signals were discriminated ana digitized via triggering signal and used to localize the position of an event by applying the Anger logic. Results: The intrinsic sensitivity of the system was approximately 8,000 counts/sec/${\mu}Ci$. High quality flood and hole mask images were obtained. Breast phantom containing $2{\sim}7 mm$ diameter spheres was successfully imaged with a parallel hole collimator The image displayed accurate size and activity distribution over the imaging field of view Conclusion: We have succesfully developed a small gamma camera using NaI(T1)-PSPMT and nuclear Instrument modules. The small gamma camera developed in this study might improve the diagnostic accuracy of scintimammography by optimally imaging the breast.

  • PDF

Is $^{99m}Tc$-MDP Mammoscintigraphy Useful in Patients with Breast Mass Lesions? ($^{99m}Tc$-MDP 유방 스캔은 유방 종괴의 감별진단에 임상적인 유용성이 있는가?)

  • Park, Seok-Gun;Lee, Yeon-Hee;Rhyu, Jin-Woo;You, Sun-Mee
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.2
    • /
    • pp.151-160
    • /
    • 1998
  • Purpose: Piccolo et al. advocated the usefulness of $^{99m}Tc$-MDP breast scan in differential diagnosis of breast mass with high accuracy. But there are little or no follow-up studies about it as we know. We studied $^{99m}Tc$-MDP uptake pattern and lesion/background ratio in patients complaining palpable breast lesions to evaluate the clinical usefulness of $^{99m}Tc$-MDP scan. Materials and Methods: Total 34 patients were studied with physical examination, mammo-gram and $^{99m}Tc$-MDP scan prospectively. Anteroposterior and both lateral view of breast were obtained 5 minutes after iv injection of 740 MBq $^{99m}Tc$-MDP. Breast uptake pattern of $^{99m}Tc$-MDP was analyzed by a grade system: 0=no uptake, grade 1=bilateral diffuse uptake, grade 2=asymmetric faint uptake, grade 3=focal hot uptake. 20 cases were pathologically confirmed by excision biopsy or aspiration biopsy. 14 cases were normal in physical examination and mammogram. Results: Pathologic results showed 7 carcinomas, 6 benign solid tumors, and 7 fibrocystic changes. Grade 3 pattern of $^{99m}Tc$-MDP uptake was noted in 4/7 carcinomas, 3/6 benign solid tumors, and 1/7 fibrocystic changes. Grade 2 pattern was 217, 0/7, 3/7 respectively. The average L/B ratio was 1.66 in carcinomas, 1.68 in benign solid masses, 1.20 in fibrocystic diseases, 1.05 in normal patients. L/B ratio was higher in carcinoma and benign mass groups than in fibrocystic change and normal control groups(p=0.005). But there was no statistical difference between L/B ratio of malignant mass group and benign mass group. Conclusion: $^{99m}Tc$-MDP scan is not suitable to routine clinical use for breast mass diagnosis. It might be used in limited conditions when whole body bone scan is planned.

  • PDF

Analysis and Prediction of Sewage Components of Urban Wastewater Treatment Plant Using Neural Network (대도시 하수종말처리장 유입 하수의 성상 평가와 인공신경망을 이용한 구성성분 농도 예측)

  • Jeong, Hyeong-Seok;Lee, Sang-Hyung;Shin, Hang-Sik;Song, Eui-Yeol
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.3
    • /
    • pp.308-315
    • /
    • 2006
  • Since sewage characteristics are the most important factors that can affect the biological reactions in wastewater treatment plants, a detailed understanding on the characteristics and on-line measurement techniques of the influent sewage would play an important role in determining the appropriate control strategies. In this study, samples were taken at two hour intervals during 51 days from $1^{st}$ October to $21^{st}$ November 2005 from the influent gate of sewage treatment plant. Then the characteristics of sewage were investigated. It was found that the daily values of flow rate and concentrations of sewage components showed a defined profile. The highest and lowest peak values were observed during $11:00{\sim}13:00$ hours and $05:00{\sim}07:00$ hours, respectively. Also, it was shown that the concentrations of sewage components were strongly correlated with the absorbance measured at 300 nm of UV. Therefore, the objective of the paper is to develop on-line estimation technique of the concentration of each component in the sewage using accumulated profiles of sewage, absorbance, and flow rate which can be measured in real time. As a first step, regression analysis was performed using the absorbance and component concentration data. Then a neural network trained with the input of influent flow rate, absorbance, and inflow duration was used. Both methods showed remarkable accuracy in predicting the resulting concentrations of the individual components of the sewage. In case of using the neural network, the predicted value md of the measurement were 19.3 and 14.4 for TSS, 26.7 and 25.1 for TCOD, 5.4 and 4.1 for TN, and for TP, 0.45 to 0.39, respectively.