• 제목/요약/키워드: Control Zone

검색결과 1,511건 처리시간 0.025초

이중 바닥 온돌 시스템의 응용에 관한 이론적 분석 (Theoretical Analysis on the Applications of the Double-Floor Ondol System)

  • 최원기;이강영;이현근;서승직
    • 설비공학논문집
    • /
    • 제19권5호
    • /
    • pp.355-363
    • /
    • 2007
  • The Korean traditional 'Ondol' system has been a target for innovation to meet the requirements of sustainable domestic building and low carbon emission energy utilization. Simulation techniques provide designers and researchers with powerful tools to predict heating load and thermal behaviour of Ondol systems installed in various contexts. However, there are few studies on Ondol models, especially associated with multi-stories buildings of which type covers about 50% of Korean housing stock. In this study, we analyzed the double floor Ondol system on the multi-stories buildings using the ESP-r program. On the basis of the double floor Ondol system, we suggested the new modelling method that is composed of the Vent zone and Ondol zone. Using the this model, sensitivity analysis was carried out to refine the applicability of the model taking account of control conditions, constructions, air change and air flow network method and CFD analysis using the FLUENT. The air layer has enough temperature to use in heating zone. It is suggested that the simplicity of the model will allow building designers and mechanical engineers easily to implement scenario-based assessments of design options as well as control strategies. Later, we will simulate the real buildings and analyze the air distributions using the Fluent according to the various conditions.

제연구역 출입문의 차압 및 개방력 측정기준의 실효성 분석에 관한 연구 (Study on the Analysis of Differential Pressure of the Access Door for a Smoke Control Zone and the Effectiveness of the Measurement Criteria of its Opening Force)

  • 이재오;최충석
    • 한국화재소방학회논문지
    • /
    • 제26권4호
    • /
    • pp.24-30
    • /
    • 2012
  • 본 연구에서는 화재실과 인접부 제연구역의 차압 및 방화문의 개방력을 측정할 때의 문제점을 분석하고, 객관적인 방법에 의해 측정된 실측값을 제시하는데 있다. NFSC 501A의 제연설비 가동 시 출입문의 개방에 필요한 힘은 110 N 이하로 규정하고 있다. 제연설비가 설치된 공간에서 제연설비가 작동하지 않을 때는 KS F 2805의 시험방법에 의해서 개방력의 측정이 가능하지만 제연설비가 작동되었을 때는 화재실과 제연실의 차압에 의해 발생되는 추가적인 힘이 필요하므로 기준에서 제시하는 시험방법은 신뢰성이 부족함을 알 수 있다. 제연설비 가동 전 완전히 폐쇄된 상태의 개방력은 아날로그측정기($F_a$) 27.8 N, 디지털측정기($F_d$) 27.4 N을 각각 나타냈다. 그리고 문이 $5^{\circ}$ 개방된 상태의 개방력 $F_a$는 33 N, $F_d$는 33.6 N을 나타냈다. 제연설비가 작동되고 완전히 폐쇄된 상태의 개방력 $F_a$는 45.3 N, $F_d$는 46.9 N을 나타냈고, 문이 $5^{\circ}$ 개방된 상태의 개방력 $F_a$는 77.6 N, $F_d$는 76.0 N 등으로 확인되었다. 따라서 현재의 KS F 2805에서 제시하고 있는 기준과 상이하므로 적절한 기준의 검토가 요구된다.

작업면 현휘 방지와 주광 및 일사 유입 최대화를 위한 제어 종료 영역에서의 최적 블라인드 제어 (Optimum Blind Control at the End of Operation Time Zone for Preventing Glare on Work-plane and Maximizing Daylight and Solar Heat Gain)

  • 성윤복;여명석;구소영;김광우
    • 한국주거학회논문집
    • /
    • 제23권1호
    • /
    • pp.27-41
    • /
    • 2012
  • The objective of this study is to develop the blind control strategy and method which reduce negative effect of incoming daylight on visual comfort of occupants, minimize psychological anxieties caused by frequent motions of a blind, and maximize positive effect of incoming daylight and solar irradiation by opening/closing of a blind. As previous researches on blind controls have limited outdoor environmental conditions to those in specific regions, orientations and dates, these resulted in problems at various conditions for general-purpose application. Major problem is that the time interval and amount of blind movement do not meet the control objective at the end of control zone and discontinuous curve. To overcome these limitations revealed in the previous researches, following tasks were performed in this study. 1) To establish the control objective to accomplish the goal of this study. 2) To develop the control methods and algorithms which prevent glare on the work-plane at any time and which control the time interval and amount of blind movement to follow the control objective at various profile angle curves. 3) To validate the general-purpose applicability and performance of the developed control methods and algorithms by simulation and its data analysis at various conditions. It was found that the proposed methods and algorithms can prevent the direct glare on the work-plane at all the time and also increase the incoming daylight and solar irradiation.

고속철도 열차 증속에 따른 접속부 거동특성 분석 (Transition Zone Behavioral Characteristics with Increase the Speed of High Speed railroad)

  • 박효성;김낙석;강윤석
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.1583-1593
    • /
    • 2011
  • As we see the continuation of the increase in the speed of the High Speed railroad worldwide, there is a concern for a possible problem in the connecting transition zone in the railway infrastructure. Honam High Speed railroad's transition zone in the hub for the rotation structures and other supporting structures such as approach slab, sub slab, approach block, etc. Due to its increase in speed of the design speed, and its important role on the driving stability and credibility of the bearing ground performance, we must seek and fine a prevention plan for a cause of differential settlement, as well as the cause of the derailment. In this dissertation, domestic, as well as international design manuals and the applicability of the control standards are studied. Also through the study target, Honam High Speed railroad zone 4-1, we evaluated the connecting componant of the Yeon-Jeong bridge through the eigenvalue and weight transfer of the train when operated at 300km/h, 350km/h, 400km/h, 450km/h, and were able to achieve detailed assessment by checking track behaviors, looking at various components such as the rotation acceleration according to the inversion of the distance length, displace length, displacement and stress distribution. Through these studied, possibility of operating at 400km/h was evaluated based on the condition of the current design basis.

  • PDF

Distribution Patterns of Calanoid Copepods along the Seomjin River Estuary in Southern Korea during Summer

  • Park, Eun-Ok;Rahman, Muhammad Shafiqur;Seo, Min Ho;Kim, Jong Jyu;Soh, Ho Young
    • 환경생물
    • /
    • 제31권2호
    • /
    • pp.165-171
    • /
    • 2013
  • The distribution patterns of estuarine copepods were investigated in the Seomjin River estuary of southern Korea after heavy rains in August 2006. Tidal influence extended 16 km from the estuary mouth. Each estuary zone (Oligohaline salinity <5, mesohaline salinity 5~18, polyhaline salinity >18) changed within a range of about 5~6 km between low and high tides. A total of ten species were recorded, of which Pseudodiaptomus koreanus, Sinocalanus tenellus, and Tortanus dextrilobatus were predominant in the oligohaline zone; Acartia ohtsukai and Acartia forticrusa in the mesohaline zone; and A. erythraea, Calanus sinicus, Centropages dorsispinatus, Labidocera rotunda and Paracalanus parvus s. l. in the polyhaline zone. Their density was fastly reduced in the other zones. In particular, the oligohaline species migrated and aggregated into deeper water during ebb tides in order to retain their populations, while the same tendency was weaker for polyhaline species, suggesting that evolutionary traits primarily control population retention behaviors in estuarine environments.

Designation and Management of Water Source Protection Areas for Indirect Intakes

  • Choi, Ji-Yong;Hwang, Dae-Ho
    • Environmental Engineering Research
    • /
    • 제15권4호
    • /
    • pp.231-237
    • /
    • 2010
  • With increased chemical and economic development activities in upstream areas, the amounts of pollutants released have increased, and as such, so has the need for positive management of water supply source areas. Although more than 90% of the water supply sources in Korea depend on direct intake from surface water, the interest in indirect intake, such as riverbank filtration water, has recently risen, with some local governments currently undertaking indirect intake. Even in cases of indirect intake, water supply source protection zones need to be assigned for the comprehensive control of pollutants. To establish water quality protection zones for indirect intake, the scope of the protection zones needed to reflect the hydrological features of the water-bearing deposits of each site. Water source protection areas were estimated and presented as the 1st (within a 100 m radius from an intake well) and 2nd (within a 2 km radius from an intake well) zones. The 1st zone was more sensitive; hence, the installation of various facilities should be prohibited, and the area should be regarded as off-limits. For the 2nd zone, appropriate management should prohibit and restrict activities already present in the water source protection zone.

싱글모드 파이버 레이저를 이용한 SUS304와 Ti 이종재료의 용접속도에 따른 용접특성 (Weldability of SUS304 and Ti Dissimilar Welds with Various Welding Speed using Single Mode Fiber Laser)

  • 이수진;카타야먀 세이지;김종도
    • Journal of Welding and Joining
    • /
    • 제31권5호
    • /
    • pp.64-70
    • /
    • 2013
  • The joining of Ti and SUS304 dissimilar metals is one of the effective measures to save rare metal. But Ti and SUS304 have differences in materials properties, and Ti and Fe intermetallic compounds such as TiFe and $TiFe_2$ are easily formed in weld fusion zone between Ti and SUS304. Nevertheless, in this study, full penetration lap dissimilar welding of Ti and SUS304 using single-mode fiber laser with ultra-high welding speed was tried, and it was found out that ultra-high welding speed could control the generation of intermetallic compound. To recognize the formation of intermetallic phase in the weld fusion zone and the compound zone of interface weld area were observed and analyzed using energy dispersive X-ray spectroscopy (EDX). And it was confirmed that the ultra-high welding speed could reduce amount of intermetallic compounds, but the intermetallic compounds were existed in the weld fusion zone under the all conditions.

데드 존 스위칭 영역을 갖는 정현파형 브러시리스 직류전동기의 가변구조 속도제어기 설계 (Design of a Variable Structure Speed Controller having a Dead Zone Switching layer for the Sinusoidal type Brushless DC Motor)

  • 김세일;최중경;박승엽
    • 한국정보통신학회논문지
    • /
    • 제3권3호
    • /
    • pp.639-650
    • /
    • 1999
  • 본 논문에서는 정현파형 브러시리스 직류 전동기의 속도제어를 위해 두 개의 스위칭 라인에 의해 구성된 채터링 둔감영역을 갖는 가변구조 속도제어기를 설계한다. 슬라이딩 모드 과정 중 과도상태에서 발생하는 고주파 채터링을 저주파로 한정시키기 위해 데드 존(Dead Zone) 함수의 도입을 제안하고, 정상상태에서의 채터링 및 정상상태 오차를 제거하기 위해서는 제어입력에 시변이득을 적용한다. 제안된 데드 존 함수는 두개의 스위칭 함수로 구성된 슬라이딩 영역을 표시하며 이 영역에 시스템의 상태가 존재 시제어 구조를 PI제어기로 변경하여 채터링이 발생하지 않으며 이 영역의 이탈 시만 가변구조제어를 적용하므로 채터링이 발생하게 되어 과도상태의 고주파 채터링을 저주파로 감소시킬 수 있다. 설계된 속도 제어기에 대해 컴퓨터 시뮬레이션과 실험을 통하여 그 성능을 보인다.

  • PDF

기립상태에서 발바닥에 인가한 진동자극의 주파수에 따른 자세균형 응답 (Effects of Plantar sole Vibration using Various Frequencies on Postural Response During Standing)

  • 유미;박용군;김동욱;김남균
    • 대한의용생체공학회:의공학회지
    • /
    • 제30권3호
    • /
    • pp.247-254
    • /
    • 2009
  • We studied the postural response induced by plantar sole vibration with various frequencies(20, 60, 100Hz) and vibration zone(the anterior and posterior foot zone) of both soles during standing. Eight healthy young adults were exposed to 15s periods of plantar sole vibration while blindfolded. Body sway(COM, center of mass), the angle of neck, trunk, hip, knee, ankle and EMG of four lower limb muscles(tibialis anterior, lateral and medial gastrocnemial, soleus muscle) were recorded during 15s plantar sole vibration using 3D motion analysis system. Simulating each zone separately resulted in spatially oriented body tilts; oppositely directed backward and forward, respectively, the amplitude of which was proportional to the vibration frequency. EMG activity of lower limb muscles also varied according to the direction of the vibration zone and linearly according to the frequency. These findings led us to consider the plantar sole vibration as useful method of postural balance control and adjustment.

이더넷 통신기반의 자율적 고장 판단 및 복구 방법론 연구 (The Self-Fault Determination and Restoration Methodology based on the Ethernet Communication)

  • 고윤석;이서한;최현철;신재현
    • 전기학회논문지
    • /
    • 제58권9호
    • /
    • pp.1674-1680
    • /
    • 2009
  • This paper proposes an autonomous fault determination, fault zone isolation and fault restoration strategy based on the ethernet communication as a new attempt to solve the problem the of the existing central control method. In proposed method, The FRTU(Feeder Remote Terminal Unit)s on the feeder determines autonomously where the faulted zone is by exchanging the voltage and current information with neighbor FRTUs based on the network communication, and then separates the faulted zone in an nil-voltage status to make the protective device to reclose successively. In particular, the minimization of outage time and relational load balancing is archived by each interconnection switch which determines autonomously the load zone to be allocated among those zones after the sound outage zones was separated individually. Finally, to show effectiveness of the proposed fault restoration strategy, the several fault cases are simulated for the test distribution system, and the load balancing index of the proposed solution is compared with all of feasible solutions.