• 제목/요약/키워드: Control Strategy

검색결과 4,559건 처리시간 0.038초

멀티-스팬 연속 공정 시스템의 실시간 장력 제어 (Real-Time Tension Control in a Multi-Span Continuous Process System)

  • 신기현
    • 한국정밀공학회지
    • /
    • 제12권5호
    • /
    • pp.108-116
    • /
    • 1995
  • A tension control strategy for a multi-span web transport system is proposed. This strategy is developed by using the tension transfer phenomena in multi-span systems. The performance of this control strategy is compared with that of an existing control strategy through a computer simulation. A real-time software is designed based on the proposed tension control stration of master speed drive in tension control is demonstrated.

  • PDF

전자 제어 CVT 차량의 변속제어전략 (Shift Control Strategy for Electric Controlled CVT Vehicle)

  • 김동우;김현수
    • 한국자동차공학회논문집
    • /
    • 제8권3호
    • /
    • pp.85-97
    • /
    • 2000
  • In this paper, static and dynamic shift control stategies of CVT speed ratio are suggested. For the static shift control, in order to operate engine on the optimal operating region, a fuzzy control logic is used. In the fuzzy logic, S- factor that is defined as a degree of sportiness is introduced. Simulation results show that the static shift control strategy based on the fuzzy logic selects the optimal operating point automatically between the economy and the sporty mode corresponding to the driver's desire and the driving condition. For the dynamic shift control strategy, a shift speed map is suggested which determines the shift sped as fast or slow based on Δi, the difference between the desired speed ratio id and the actual speed ratio i, and throttle opening. It is seen from the simulation results that the CVT shift speed is determined by the dynamic shift control strategy to provide appropriate performance and comfort for the driver's demand and driving condition. Additionally, experiments are performed to investigate the dynamic performance of the shift speed for the lift foot up. From the experimental results, it is found that improved shift feeling can be obtained by the dynamic shift control strategy when lift foot up occurs.

  • PDF

Static Synchronous Series Compensator(SSSC) 댐핑 제어 및 해석모형 (Damping Control Strategy and Analysis Model of Static Synchronous Series Compensator(SSSC))

  • 김학만;전영환;오태규
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제49권10호
    • /
    • pp.509-515
    • /
    • 2000
  • This paper addresses a damping control strategy of Static Synchronous Series Compensator(SSSC) and analysis model for stability study. The effect of injected voltage source generated by SSSC is modelled as equivalent load. This model is thought to be reasonable for the stability study because the dynamics of SSSC is very fast compared with that of power system. Damping controller of SSSC is based on Transient Energy Function method. The proposed control strategy is insensitive to the operating conditions like power flow level because control law depends on the phase angles. The proposed analysis model and control strategy was confirmed by WSCC 9 bus system and two area system. Especially, the robustness of proposed control strategy is demonstrated with respect to multiple operating conditions in two area system.

  • PDF

Adaptive Sliding Mode Control with Enhanced Optimal Reaching Law for Boost Converter Based Hybrid Power Sources in Electric Vehicles

  • Wang, Bin;Wang, Chaohui;Hu, Qiao;Ma, Guangliang;Zhou, Jiahui
    • Journal of Power Electronics
    • /
    • 제19권2호
    • /
    • pp.549-559
    • /
    • 2019
  • This paper proposes an adaptive sliding mode control (ASMC) strategy with an enhanced optimal reaching law (EORL) for the robust current tracking control of the boost converter based hybrid power source (HPS) in an electric vehicle (EV). A conventional ASMC strategy based on state observers and the hysteresis control method is used to realize the current tracking control for the boost converter based HPS. Then a novel enhanced exponential reaching law is proposed to improve the ASMC. Moreover, an enhanced exponential reaching law is optimized by particle swarm optimization. Finally, the adaptive control factor is redesigned based on the EORL. Simulations and experiments are established to validate the ASMC strategy with the EORL. Results show that the ASMC strategy with the EORL has an excellent current tracking control effect for the boost converter based HPS. When compared with the conventional ASMC strategy, the convergence time of the ASMC strategy with the EORL can be effectively improved. In EV applications, the ASMC strategy with the EORL can achieve robust current tracking control of the boost converter based HPS. It can guarantee the active and stable power distribution for boost converter based HPS.

청소년의 정서성과 정서조절전략 및 자기통제력 (Relationships of Positive and Negative Emotion to Cognitive Reappraisal and Expressive Suppression Emotional Regulation Strategies and Self-Control in Adolescence)

  • 한선화;현온강
    • 아동학회지
    • /
    • 제27권6호
    • /
    • pp.1-11
    • /
    • 2006
  • Analysis of the data concerning 525 middle and high school students showed that positive affect correlated positively with cognitive reappraisal strategy and with self-control but correlated negatively with expressive suppression strategy. Negative affect correlated positively with expressive suppression strategy and negatively with self-control. The group of higher positive and higher negative affect was higher than the group of lower positive and lower negative affect in cognitive reappraisal strategy. The group of higher positive and higher negative affect was higher than the group of higher positive and lower negative affect in expressive suppression strategy. The group of higher positive and lower negative affect was higher than the group of higher positive and higher negative affect in self-control.

  • PDF

유압식 이족 휴머노이드 로봇의 경사면 보행 연구 (Biped Walking of Hydraulic Humanoid Robot on Inclined Floors)

  • 김정엽
    • 제어로봇시스템학회논문지
    • /
    • 제18권3호
    • /
    • pp.258-266
    • /
    • 2012
  • This paper describes a biped walking algorithm for a hydraulic humanoid robot on inclined floors. To realize stable and robust biped walking, the walking algorithm was divided into five control strategies. The first is a joint position control strategy. This strategy is for tracking desired joint position trajectories with a gain switching. The second is a multi-model based ZMP (Zero Moment Point) control strategy for dynamic balance. The third is a walking pattern flow control strategy for smooth transition from step to step. The fourth is an ankle compliance control, which increases the dynamic stability at the moment of floor contact. The last is an upright pose control strategy for robust walking on an inclined floor. All strategies are based on simple pendulum models and include practical sensory feedback in order to implement the strategies on a physical robot. Finally, the performance of the control strategies are evaluated and verified through dynamic simulations of a hydraulic humanoid on level and inclined floors.

FUZZY TORQUE CONTROL STRATEGY FOR PARALLEL HYBRID ELECTRIC VEHICLES

  • PU J.-H.;YIN C.-L.;ZHANG J.-W.
    • International Journal of Automotive Technology
    • /
    • 제6권5호
    • /
    • pp.529-536
    • /
    • 2005
  • This paper presents a novel design of a fuzzy control strategy (FCS) based on torque distribution for parallel hybrid electric vehicles (HEVs). An empirical load-regulating vehicle operation strategy is developed on the basis of analysis of the components efficiency map data and the overall energy conversion efficiency. The aim of the strategy is to optimize the fuel economy and balance the battery state-of-charge (SOC), while satisfying the vehicle performance and drivability requirements. In order to accomplish this strategy, a fuzzy inference engine with a rule-base extracted from the empirical strategy is designed, which works as the kernel of a fuzzy torque distribution controller to determine the optimal distribution of the driver torque request between the engine and the motor. Simulation results reveal that compared with the conventional strategy which uses precise threshold parameters the proposed FCS improves fuel economy as well as maintains better battery SOC within its operation range.

전력 계통내에서 순간 전압 강하에 빠른 응답 특성을 가진 DVR의 제어 (Synchronous PI control scheme for DVR against a voltage sag in the power system)

  • 김명복;이승훈;문건우;윤명중
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(2)
    • /
    • pp.554-559
    • /
    • 2003
  • A new control strategy for dynamic voltage restorer (DVR) is proposed. It is based on synchronous PI control strategy which features fast response. Therefore, the proposed control strategy takes faster action against a voltage sag. Experimental results, executed by DSP, are shown to validate the proposed control strategy.

  • PDF

Estimating Stability of MTDC Systems with Different Control Strategy

  • Nguyen, Thai-Thanh;Son, Ho-Ik;Kim, Hak-Man
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권2호
    • /
    • pp.443-451
    • /
    • 2015
  • The stability of a multi-terminal direct current (MTDC) system is often influenced by its control strategy. To improve the stability of the MTDC system, the control strategy of the MTDC system must be appropriately adopted. This paper deals with estimating stability of a MTDC system based on the line-commutated converter based high voltage direct current (LCC HVDC) system with an inverter with constant extinction angle (CEA) control or a rectifier with constant ignition angle (CIA) control. In order to evaluate effects of two control strategies on stability, a MTDC system is tested on two conditions: initialization and changing DC power transfer. In order to compare the stability effects of the MTDC system according to each control strategy, a mathematical MTDC model is analyzed in frequency domain and time domain. In addition, Bode stability criterion and transient response are carried out to estimate its stability.

과포화교통상태에서의 SPLIT COORDINATION신호제어전략 (Green-Split Coordination Strategy in Oversaturated Signal System)

  • 이광훈
    • 대한교통학회지
    • /
    • 제11권1호
    • /
    • pp.87-103
    • /
    • 1993
  • The subject this paper is the signal control strategy under oversaturated conditions. The nature of traffic control for oversaturation is essentially different from the standard control modes. While under non-saturated situation traffic control is needed for the sake of safety and efficiency, the throughput is essential under oversaturated conditions. Therefore berth objective and strategies differ. For an oversaturated stream the cycle time and the signal offset are thought to be of rather secondary importance. For this case the green split may well be the most important control variable to serve the excessive demand. Up to now, however, most efforts have concentrated on the strategy with the concept which lies just on the extension of Webster's. "Green-split Coordination Strategy for Over-Saturated Networks", presents newly contrived three types of strategies named Forward-coordination, Backward-coordination and Network-coordination respectively and describes the algorithms with the evaluations. The forward coordination strategy treats the forward wave of flow between two signals. The aim is to prevent the outbreak of queue due to the accumulation of temporary excess of demand in near-saturation or saturation flow. The backward coordination strategy treats the backward rave of flow between two signals. The goal is to prevent the waste of green time caused by the exit block at the upstream signal. for this purpose a feedback regulation is provided of the upstream green-split so that the inflow-outflow balance is kept zero. The resultant surplus of green time is alloted to other signal stages. Also here the examination is made of the appropriate value of the feedback control parameter. The network coordination strategy is operated to maximize the network throughput in a specific direction applying a bang-bang control at the bottleneck intersection. This is a type of intervenient control for policy reasons. For this strategy the green-split coordinations, particuarly the backward coordination, are essential as the tactical elements. In order to evaluate the preposed strategies those are compared with the latest existing strategy called saturation-degree-ratio control by the simulation experiments in an assumed 4$\times$4 grid network. The results are satisfactory showing a 10-15% reduction in delays and a 15% increase in network capacity.

  • PDF