• Title/Summary/Keyword: Control Strategies

Search Result 2,474, Processing Time 0.034 seconds

Effects of Infection Control Strategies for Vancomycin Resistant Enterococci in Intensive Care Units (중환자실에서 적용한 반코마이신(Vancomycin) 내성 장구균의 감염관리 전략 효과)

  • Choi, Kyung-Ok;Kim, Nam-Cho
    • Korean Journal of Adult Nursing
    • /
    • v.21 no.4
    • /
    • pp.435-445
    • /
    • 2009
  • Purpose: This study was to examine whether VRE infection control strategies have an effect on the decrease in incidence rates for VRE acquisition and VRE nosocomial infection in ICU. Methods: All the patients were examined for VRE carriers on ICU admission. Among them, patients hospitalized for over 48 hours were investigated for VRE acquisition rates and VRE nosocomial infection rate using VRE infection control strategies in ICU for the experimental group from September 2007 to April 2008. Before that, incidence of VRE acquisition and VRE nosocomial infection for the control group without Intervention were investigated from May to August 2007 retrospectively. Results: VRE acquisition rate in clinical specimens was 0.6% in the experimental group, that was significantly lower when compared to the control group. VRE carrier rate at admission to ICU was 15.4%. Out of 182 VRE carriers, 180 patients were identified by the active surveillance culture. Conclusion: These results suggested that active surveillance culture at admission was considered to be an essential measure for detection of VRE carrier. But without strict isolation and adherence rating after each intervention, hand washing and contact isolation alone did not significantly decrease VRE nosocomial infection, although it did significantly decrease incidence of VRE acquired from clinical specimen.

  • PDF

Experimental Study on Optimal Operation Strategies for Energy Saving in Building Central Cooling System (건물 중앙냉방시스템의 에너지절감을 위한 최적운전 방안에 관한 실험적 연구)

  • Hwang, Jin-Won;Ahn, Byung-Cheon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.9
    • /
    • pp.4610-4615
    • /
    • 2013
  • In this study, optimal operation strategies to save the electric energy and power price in the building central cooling system is researched by experiments. The optimal strategies of demand response control and outdoor temperature reset control algorithms are applied by consideration the electric energy and power price according to the energy consumption characteristics. The suggested optimal control method shows better responses in the power price and energy consumption in comparison with the conventional one and saves energy consumption by 9.5% and electronic price by 15.7%, respectively.

Preventive and Emergency Control of Power System for Transient Stability Enhancement

  • Siddiqui, Shahbaz A.;Verma, Kusum;Niazi, K.R.;Fozdar, Manoj
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.1
    • /
    • pp.83-91
    • /
    • 2015
  • This paper presents preventive and emergency control measures for on line transient stability (security) enhancement. For insecure operating state, generation rescheduling based on a real power generation shift factor (RPGSF) is proposed as a preventive control measure to bring the system back to secure operating state. For emergency operating state, two emergency control strategies namely generator shedding and load shedding have been developed. The proposed emergency control strategies are based on voltage magnitudes and rotor trajectories data available through Phasor Measurement Units (PMUs) installed in the systems. The effectiveness of the proposed approach has been investigated on IEEE-39 bus test system under different contingency and fault conditions and application results are presented.

Optimal Internet Worm Treatment Strategy Based on the Two-Factor Model

  • Yan, Xiefei;Zou, Yun
    • ETRI Journal
    • /
    • v.30 no.1
    • /
    • pp.81-88
    • /
    • 2008
  • The security threat posed by worms has steadily increased in recent years. This paper discusses the application of the optimal and sub-optimal Internet worm control via Pontryagin's maximum principle. To this end, a control variable representing the optimal treatment strategy for infectious hosts is introduced into the two-factor worm model. The numerical optimal control laws are implemented by the multiple shooting method and the sub-optimal solution is computed using genetic algorithms. Simulation results demonstrate the effectiveness of the proposed optimal and sub-optimal strategies. It also provides a theoretical interpretation of the practical experience that the maximum implementation of treatment in the early stage is critically important in controlling outbreaks of Internet worms. Furthermore, our results show that the proposed sub-optimal control can lead to performance close to the optimal control, but with much simpler strategies for long periods of time in practical use.

  • PDF

A Combined Process Control Procedure by Monitoring and Repeated Adjustment

  • Park, Changsoon
    • Communications for Statistical Applications and Methods
    • /
    • v.7 no.3
    • /
    • pp.773-788
    • /
    • 2000
  • Statistical process control (SPC) and engineering process control (EPC) are based on different strategies for processes quality improvement. SPC reduces process variability by detecting and eliminating special causes of process variation. while EPC reduces process variability by adjusting compensatory variables to keep the quality variable close to target. Recently there has been needs for a process control proceduce which combines the tow strategies. This paper considers a combined scheme which simultaneously applies SPC and EPC techniques to reduce the variation of a process. The process model under consideration is an integrated moving average(IMA) process with a step shift. The EPC part of the scheme adjusts the process back to target at every fixed monitoring intervals, which is referred to a repeated adjustment scheme. The SPC part of the scheme uses an exponentially weighted moving average(EWMA) of observed deviation from target to detect special causes. A Markov chain model is developed to relate the scheme's expected cost per unit time to the design parameters of he combined control scheme. The expected cost per unit time is composed of off-target cost, adjustment cost, monitoring cost, and false alarm cost.

  • PDF

Trends and Control Technologies of Volatile Organic Compound (국내의 휘발성유기화합물(VOC) 현황 및 관리기술)

  • Kim, Jo-Chun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.6
    • /
    • pp.743-757
    • /
    • 2006
  • Volatile organic compound (VOC) has been well-known to Korea since the end of 1990's however, it has not been well documented until now. In this study, present ambient VOC levels, VOC emission sources, and VOC control technologies were reviewed and discussed. In addition, VOC management strategies to cut down ozone concentrations were suggested based on the present VOC database. For anthropogenic VOC reduction, VOC emitted from painting processes and automobiles should be controlled in the first place in large cities such as Seoul, Daegu, and Incheon. For natural VOC management, low emission trees need to be planted in those cities. It is also very significant to keep updating present and future VOC emission inventories for efficient VOC control strategies. As a conclusion, more systematic VOC control road-map based on BACT (best available control technology) needs to be made up. and more economical and efficient VOC control techniques have to be developed under strong national support in order to lower toxic VOC and photochemical oxidant levels.

Evaluation of AGC Characteristics and a Novel AGC Control Strategy for Independent Power Systems (단독계통의 주파수 제어를 위한 자동발전제어(AGC) 특성 분석 및 새로운 제어전략)

  • Choi, Seung-Ho;Hwang, Kyo-Ik;Chun, Yeonghan
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.54 no.11
    • /
    • pp.540-547
    • /
    • 2005
  • One of the roles of AGC is to regulate the frequency of power systems. AGC is also used to control the frequency of Korean Power System. AGC control strategies depend on system characteristics and the requirements of the systems to which those are applied. Korean Power System consists of one control area and does not have tie-lines. In this research, an AGC control strategy is suggested to avoid conflict with governor dynamics and to enhance frequency recovery It shows good performance for regulation and frequency recovery. This control strategy is expected to be applied to New EMS in KPX to get reasonable AGC regulation and frequency recovery performance.

Demand Control Application Strategies for Saving Electric Power Price of Central Cooling System (중앙 냉방시스템의 전력량 요금절감을 위한 디맨드제어 적용방안 연구)

  • Hwang, Jin-Won;Song, Jae-Yeob;Ahn, Byung-Cheon
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.8 no.4
    • /
    • pp.1-7
    • /
    • 2012
  • In this study, computer simulation for demand control strategies to save the electric energy and power price in the building central cooling system is done. The demand control and outdoor reset control algorithms are applied by consideration the electric energy and power price according to the energy consumption characteristics. The suggested control methods show better responses in the power price and energy consumption in comparison with the conventional one.

Configuration assessment of MR dampers for structural control using performance-based passive control strategies

  • Wani, Zubair R.;Tantray, Manzoor A.;Iqbal, Javed;Farsangi, Ehsan Noroozinejad
    • Structural Monitoring and Maintenance
    • /
    • v.8 no.4
    • /
    • pp.329-344
    • /
    • 2021
  • The use of structural control devices to minimize structural response to seismic/dynamic excitations has attracted increased attention in recent years. The use of magnetorheological (MR) dampers as a control device have captured the attention of researchers in this field due to its flexibility, adaptability, easy control, and low power requirement compared to other control devices. However, little attention has been paid to the effect of configuration and number of dampers installed in a structure on responses reduction. This study assesses the control of a five-story structure using one and two MR dampers at different stories to determine the optimal damper positions and configurations based on performance indices. This paper also addresses the fail-safe current value to be applied to the MR damper at each floor in the event of feedback or control failure. The model is mathematically simulated in SIMULINK/MATLAB environment. Linear control strategies for current at 0 A, 0.5 A, 1 A, 1.5 A, 2 A, and 2.5 A are implemented for MR dampers, and the response of the structure to these control strategies for different configurations of dampers is compared with the uncontrolled structure. Based on the performance indices, it was concluded that the dampers should be positioned starting from the ground floor, then the 2nd floor followed by 1st and rest of the floors sequentially. The failsafe value of current for MR dampers located in lower floors (G+1) should be kept at a higher value compared to dampers at top floors for effective passive control of multi-story structures.

A Comparative Study on the Output Voltage Control Strategies of Three Phase Inverter with LC Filter for UPS (UPS 용 3상 인버터의 LC필터단 출력전압 제어 방식 비교연구)

  • Na, Woon-Ky;Kim, Tae-Wan;Jeong, Seung-Gi
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.312-317
    • /
    • 1996
  • This paper compares the output voltage control strategies of three-phase PWM inverter for uninterruptible power supply. The feedforward control, feedforward/feedback control, and decoupled feedback control in both the synchronous reference frame and the stationary reference frame are examined. In particular, it is shown that the response of the decoupled feedback controller in the synchronous reference frame can be improved by pole-zero cancellation method. It is also shown that the pole-zero cancellation method reduces to the deadbeat control, when it is implemented with digital controller.

  • PDF