• Title/Summary/Keyword: Control Parameter

Search Result 4,554, Processing Time 0.033 seconds

Implementation of Wireless PGN Analyzer for ISOBUS network

  • Tumenjargal, Enkhbaatar;Badarch, Luubaatar;Lee, Kangsan;Ham, Woonchul;Doopalam, Enkhzul;Togooch, Amartuvshin
    • Smart Media Journal
    • /
    • v.4 no.2
    • /
    • pp.46-54
    • /
    • 2015
  • Communication between ECUs (Electronic Control Units) in agricultural machineries tends to use IS011783 widely, that is PGN (Parameter Group Number) based communication protocol lays on CAN protocol by altering its identifier part. Messages in line are transferred and received between ECUs according to ISO11783 standard. This paper discusses about design of wireless monitoring system. We used an ARM Cortex-M3 microcontroller embedded development board and marvel8686 wireless module. The wireless ISOBUS monitoring system, attached to communication line, reads messages, interpret them, and display them on the screen in easily comprehendible form. It can be used to generate messages and monitor the traffic on physical bus systems. The monitoring system connected to ECUs, monitor and simulate real traffic of communication and functionality of the ECUs. In order to support our work, we have implemented the monitoring tool. The development consists of two parts: GUI of the application and firmware level programming. Hence the monitoring system is attached to the communication line and equipped by Wi-Fi module; farmer/dispatcher in a farm monitors all messages in communication line on personal computer and smart device.

A Hybrid K-anonymity Data Relocation Technique for Privacy Preserved Data Mining in Cloud Computing

  • S.Aldeen, Yousra Abdul Alsahib;Salleh, Mazleena
    • Journal of Internet Computing and Services
    • /
    • v.17 no.5
    • /
    • pp.51-58
    • /
    • 2016
  • The unprecedented power of cloud computing (CC) that enables free sharing of confidential data records for further analysis and mining has prompted various security threats. Thus, supreme cyberspace security and mitigation against adversaries attack during data mining became inevitable. So, privacy preserving data mining is emerged as a precise and efficient solution, where various algorithms are developed to anonymize the data to be mined. Despite the wide use of generalized K-anonymizing approach its protection and truthfulness potency remains limited to tiny output space with unacceptable utility loss. By combining L-diversity and (${\alpha}$,k)-anonymity, we proposed a hybrid K-anonymity data relocation algorithm to surmount such limitation. The data relocation being a tradeoff between trustfulness and utility acted as a control input parameter. The performance of each K-anonymity's iteration is measured for data relocation. Data rows are changed into small groups of indistinguishable tuples to create anonymizations of finer granularity with assured privacy standard. Experimental results demonstrated considerable utility enhancement for relatively small number of group relocations.

Improvement of Current Limiting and Recovery Characteristics of Flux-Lock Type SFCL with Series Connection of Two Coils Using Its Third Coil

  • Ko, Seok-Cheol;Kim, Young-Pil;Lim, Sung-Hun
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.1
    • /
    • pp.472-477
    • /
    • 2017
  • In this work, the current limiting and recovery characteristics of a flux-lock type superconducting fault current limiter (SFCL) with series connection of two coils were effectively improved by adding a third winding into the conventional flux-lock type SFCL with series connection of two coils. To confirm the contribution of the third winding to the current limiting and recovery characteristics of this type of the SFCL, short-circuit testing was carried out with consideration of the third winding, and the effect of the third winding on the current limiting and recovery characteristics was examined by comparative analysis of the amplitude of the limited fault current and the power burden of the high-TC superconducting (HTSC) element comprising the SFCL. Through the analysis of both the limiting impedance and the operational current as the main design parameter of the SFCL, the improved current limiting and recovery characteristics of the flux-lock type SFCL using the third winding could be verified.

A Parameter Study on the Frequency Characteristics Control of Implantable Bone Conduction Transducer Using FEA (FEA를 이용한 이식형 골전도 진동체의 주파수 특성 제어에 관한 파라미터 연구)

  • Shin, Dong Ho;Kim, Myoung Nam
    • Journal of Korea Multimedia Society
    • /
    • v.23 no.8
    • /
    • pp.1040-1048
    • /
    • 2020
  • In this study, in order to improve the implantable bone conduction transducer of the prototype proposed by Shin et al., the effect of the element parameters of the transducer on the frequency characteristics was analyzed using electromagnetic and mechanical vibration analysis. Electromagnetic analysis was performed on the size of the permanent magnet and the distance between the metal plate and the coil to derive an optimal structure that generates the maximum Lorentz force. In addition, mechanical vibration analysis was performed on the cantilever structure of the vibrational membrane in order to minimize the distortion of the transducer and to have a frequency characteristic suitable for conductive hearing loss compensation. The frequency characteristics of the transducer of the optimal structure derived through finite element method were compared with the simulation results of the previous transducer. As a result, the output magnitude (displacement) of the transducer designed with the optimal structure generated an average 8.8 times higher than the previous transducer, and the resonance frequency was generated at 0.9 kHz.

Implementation and estimation of the urophonography measurement system for diagnosis of Lower urinary tract symptom (하부요로계 폐색 진단용 요류음 계측 시스템의 구현 및 평가)

  • Jeong, Do-Un;Cho, Seong-Taek;Jeon, Gye-Rok
    • Journal of Sensor Science and Technology
    • /
    • v.14 no.1
    • /
    • pp.7-15
    • /
    • 2005
  • A sensor and measuring system were implemented to measure both uroflow and urophonography signal during urination for diagnose the lower urinary tract symptom. The implemented system was composed of the uroflow sensor using the load-cell, the urophonography measurement sensor so as stethoscope type, pre-processing part for sensors signal detection, amplifier and filter, system control parts and PC measurement program. A simulator of the lower urinary system that is experimental equipment implemented for evaluate the developed system. The two signals were measured using implemented system and analyzed these signal by means of time domain and frequency domain for extraction of the characteristic parameter which can most effectively reflected by the occlusion of the lower urinary system. Furthermore two signals were measured and analyzed with the subject of 5 healthy adult for clinical application possibility of the implemented system. As a result, the most influence bandwidth of effect according to occlusion of the lower urinary system is $253{\sim}282$ Hz of the urophonography signal.

Conformation of single polymer molecule in a slot coating flow

  • Lee, Jeong-Yong;Ryu, Bo-Kyung;Lee, Joo-Sung;Jung, Hyun-Wook;Hyun, Jae-Chun
    • Korea-Australia Rheology Journal
    • /
    • v.20 no.2
    • /
    • pp.89-94
    • /
    • 2008
  • To satisfy good mechanical and optical properties of polymer-coated film products, it will be indispensable to elucidate the molecular orientation of polymer chains within coating liquids in coating flows. Using hybridized numerical method between computational fluid dynamics (CFD) and Brownian dynamics (BD) simulations can provide the useful information for the better quality control of coated films. Flexible polymer chains, e.g., ${\lambda}$-DNA molecules here, change their conformation according to the flow strength and the flow type. The molecular conformation within the coated film on the web or substrate is quite different, because the polymer chains experience the complicated flow strength and flow types in flow field. Especially in the slot coating flow, these chains are more extended by the extension-like flow field generated in the free surface curvature just beyond the downstream die region. Also, the polymer chain extension beneath the free surface can be affected by the die geometry, e.g., the coating gap, changing flow field.

An Optimal Design of a Vertical Guide Bearing for Vibration Reduction (축계 진동 저감을 위한 수직형 안내 베어링의 최적 설계)

  • Ha, Hyun-Cheon;Park, Chul-Hyun;Kim, Hyung-Ja
    • Journal of Power System Engineering
    • /
    • v.5 no.3
    • /
    • pp.64-72
    • /
    • 2001
  • This paper describes an optimal design technology in a segment type vertical guide bearing for vertical rotating machinery. Segment type vertical guide bearings have widely used for vertical rotating machinery, however bearing problems, such as excessive vibration and temperature rise, frequently take place in the actual machine. Such excessive vibration magnitude and/or abnormal bearing metal temperature rise result in serious damage and economic losses. Thus the segment type vertical guide bearing should be designed to get optimal characteristics in order to maintain stable operation without bearing failure due to abnormal vibration and/or abnormal bearing metal temperature. The preload ratio is the most important parameter in designing the segment type vertical guide bearing. Because adjustment of the bearing preload by changing the bearing clearance could easily control both the bearing stiffness and the cooling effect. In the paper, the influence of the preload effects on the bearing metal temperature and the bearing stiffness has been investigated both theoretically and experimentally in order to find out an optimum preload ratio. Results show that the segment type vertical guide bearing has an optimum preload ratio at which the bearing stiffness reaches a masimum value while the bearing metal temperature is minimized.

  • PDF

An Auto-tuning of PID Controller using Fuzzy Performance Measure and Neural Network for Equipment System (전력설비시스템을 위한 퍼지 평가함수와 신경회로망을 사용한 PID제어기의 자동동조)

  • 이수흠;박현태;이내일
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.2
    • /
    • pp.63-70
    • /
    • 1999
  • This paper is proposed a new method to deal with the optimized auto-tuning for the Pill controller which is used to the process-control in various fields. First of all, in this method, 1st order delay system with dead time which is modelled from the unit step response of the system is Pade-approximated, then initial values are determined by the Ziegler-Nichols method. So we can find the parameters of Pill controller so as to minimize the fuzzy criterion function which includes the maximum overshoot, damping ratio, rising time and settling time. Finally, after studying the parameters of Pill controller by Backpropagation of Neural-Network, when we give new K, L, T values to Neural-Network, the optimized parameter of Pill controller is found by Neural-Network Program.rogram.

  • PDF

THE EFFECTS OF CHLORHEXIDINE USING PATTERN WITH PERIODONTAL PACK ON CLINICAL AND MICROBIOLOGIC PARAMETER AFTER PERIODONTAL SURGERY (치주포대에 클로르헥시딘 이용형태가 치주수술후 임상과 미생물학적 변수에 미치는 영향)

  • Lee, Kang-Hyun;Kim, Sung-Ho;Shin, Hyung-Shik
    • Journal of Periodontal and Implant Science
    • /
    • v.24 no.2
    • /
    • pp.376-389
    • /
    • 1994
  • A study was conducted to compare the effects of chlorhexidine mouthrinse and chlorhexidine acetate powder with periodontal pack during 4 weeks following periodontal surgery. Twelve patients were treated with Modified Widman flap procedures and devided into three groups of four patients each; control group, chlorhexidine mouthrinse group, chlorhexidine acetate powder group. Each group wasn't significant difference in clinical and microbiologic parameters at preoperation. Examination regarding plaque index, gingival index, pocket depth, change of gingival color postsurgically, pain index were performed by each methods and observed bacteria in gingiva by phase contrast microscope. Evaluations were made at 7, 14 and 28 days postsurgically. The results were as follows: l. In comparison of results revealed no significant differences in Plaque Index, Gingival Index, pocket depth and change of gingival color postsurgically. 2. The pocket depth of three experimental groups were significant reduced at 4 weeks. 3. Chlorhexidine mouthrinse group and chlorhexidine acetate powder group with periodontal pack were significant differences in pain index at 3, 4 days postsurgically. 4. Cocci and Non-motile rods were increased at 1, 2 weeks. But, motile rod and spirochete were increased at 4 weeks.

  • PDF

Dynamic Stability Flight Test for Small Aircraft using Modified Maximum Likelihood Estimation (최대공산 추정법을 이용한 항공기 동안정성 비행시험)

  • Lee, Sang-Jong;Park, Jeong-Ho;Chang, Jae-Won;Park, Il-Kyung;Kim, Keun-Taek;Seong, Kie-Jeong
    • Aerospace Engineering and Technology
    • /
    • v.9 no.2
    • /
    • pp.105-115
    • /
    • 2010
  • This technical paper describes and summarizes the flight test results for the longitudinal and lateal-directional dynamic stability characteristics. The target aircraft is the 4-seat carnard type aircraft, FireFly, which has been developed by KARI. Airborne sensors and real-time telemetry system are constructed to obtain the flight test data. The dynamic stability characteristics should be analyzed and tested by estimaitng the aerodynamic parameters in the dymaic equations of motion. The maximum likelihood estimation technique has been applied to the flight data from chirp, 3211, and doublet control inputs.