• Title/Summary/Keyword: Contrast-enhanced computed tomography

Search Result 130, Processing Time 0.024 seconds

Incidence and Risk Factors of Nausea and Vomiting after Exposure to Low-Osmolality Iodinated Contrast Media in Children: A Focus on Preparative Fasting

  • Ji Young Ha;Young Hun Choi;Yeon Jin Cho;Seunghyun Lee;Seul Bi Lee;Gayoung Choi;Jung-Eun Cheon;Woo Sun Kim
    • Korean Journal of Radiology
    • /
    • v.21 no.10
    • /
    • pp.1178-1186
    • /
    • 2020
  • Objective: To evaluate the incidence and risk factors of emetic complications associated with the intravenous administration of low-osmolality iodinated contrast media (ICM) in children undergoing computed tomography (CT). Materials and Methods: All children who underwent contrast-enhanced CT between April 2017 and July 2019 were included. Pediatric patients were instructed on the preparative dietary protocol at our institution. Experienced nurses in the radiology department monitored the children during the CT scans and recorded any emetic complications in their electronic medical records. These data were used to calculate the incidence of emetic complications. Various patient factors and technical factors, including fasting duration, the type and volume of ICM, and ongoing chemotherapy, were evaluated to identify risk factors for emetic complications using univariate and multivariate logistic regression analyses. Results: Among the 864 children (mean age, 8.4 ± 5.7 years) evaluated, 18 (2.1%) experienced emetic complications (6 experienced nausea only and 12 experienced nausea and vomiting). None of the children developed aspiration pneumonia. The mean fasting duration of patients with emesis was 7.9 ± 5.7 hours (range, 3-21 hours), whereas that of patients without nausea was 8.7 ± 5.7 hours (range, 0-24 hours). Fasting duration was not associated with the development of nausea and vomiting (p = 0.634). Multivariate logistic regression analysis revealed that ongoing chemotherapy (odds ratio [OR] = 4.323; 95% confidence interval [CI] = 1.430-13.064; p = 0.009), iomeprol use (OR = 7.219; 95% CI = 1.442-36.146; p = 0.016), and iohexol use (OR = 5.241; 95% CI = 1.350-20.346; p = 0.017) were independent risk factors for emetic complications. Conclusion: Only a small proportion (2.1%) of children experienced nausea or vomiting after exposure to low-osmolality ICM. Many children underwent excessive fasting; however, fasting duration was not associated with nausea and vomiting. Moreover, ongoing chemotherapy and the use of iomeprol or iohexol were identified as potential risk factors for emetic complications in children.

Subcutaneous Injection Contrast Media Extravasation: 3D CT Appearance (전산화단층검사에서 조영제의 피하 정맥 혈관외유출 환자의 3D영상)

  • Kweon Dae Cheol;Kim Tae Hyung;Yang Sung Hwan;Yoo Beong Gyu;Kim Myeong Goo;Park Peom
    • Progress in Medical Physics
    • /
    • v.16 no.1
    • /
    • pp.47-51
    • /
    • 2005
  • We report a case of an accidental extravasation of contrast material. A large-volume extravasation occurred in an adult during spiral contrast-enhanced CT. The amount of contrast material extravasated was 47 ml. The patient had a swelling of the dorsum right hand. The extravasation injury site was determined by CT scanning. The extavasation case was examined using five separate display techniques: axial, multi planar reformation (MPR), maximum intensity projection (MIP), volume rendering, and shaded-surfaced display (SSD). This paper introduces extravasation with the CT and the three-dimensional appearance.

  • PDF

Acute Type A Aortic Dissection in a Patient with Situs Inversus Totalis

  • Kim, Dong Kyu;Lee, Ji Min;Heo, Seon Yeong;Jung, Jong Pil;Park, Chang Ryul;Lee, Yong Jik;Lee, Sang Cjeol;Hwang, Su Kyung;Kim, Gwan Sic
    • Journal of Chest Surgery
    • /
    • v.53 no.5
    • /
    • pp.321-323
    • /
    • 2020
  • We describe the occurrence of acute type A aortic dissection in a patient with situs inversus totalis. A 37-year-old man presented to the emergency department with acute chest pain. Initial chest X-ray findings showed a right-sided heart and a left-sided liver. Contrast-enhanced computed tomography revealed a Stanford type A acute aortic dissection, aortic root dilatation, and situs inversus totalis. All of the thoracic structures were mirror-image reversed and an abnormal coronary artery was observed. The Bentall operation was performed. This report demonstrates that computed tomography and echocardiography were useful for understanding the anatomy and the presence or absence of concurrent anomalies in a patient with situs inversus totalis. The patient's postoperative course was uneventful.

Anisotropic Total Variation Denoising Technique for Low-Dose Cone-Beam Computed Tomography Imaging

  • Lee, Ho;Yoon, Jeongmin;Lee, Eungman
    • Progress in Medical Physics
    • /
    • v.29 no.4
    • /
    • pp.150-156
    • /
    • 2018
  • This study aims to develop an improved Feldkamp-Davis-Kress (FDK) reconstruction algorithm using anisotropic total variation (ATV) minimization to enhance the image quality of low-dose cone-beam computed tomography (CBCT). The algorithm first applies a filter that integrates the Shepp-Logan filter into a cosine window function on all projections for impulse noise removal. A total variation objective function with anisotropic penalty is then minimized to enhance the difference between the real structure and noise using the steepest gradient descent optimization with adaptive step sizes. The preserving parameter to adjust the separation between the noise-free and noisy areas is determined by calculating the cumulative distribution function of the gradient magnitude of the filtered image obtained by the application of the filtering operation on each projection. With these minimized ATV projections, voxel-driven backprojection is finally performed to generate the reconstructed images. The performance of the proposed algorithm was evaluated with the catphan503 phantom dataset acquired with the use of a low-dose protocol. Qualitative and quantitative analyses showed that the proposed ATV minimization provides enhanced CBCT reconstruction images compared with those generated by the conventional FDK algorithm, with a higher contrast-to-noise ratio (CNR), lower root-mean-square-error, and higher correlation. The proposed algorithm not only leads to a potential imaging dose reduction in repeated CBCT scans via lower mA levels, but also elicits high CNR values by removing noisy corrupted areas and by avoiding the heavy penalization of striking features.

Unusual Manifestation of Immunoglobulin G4-Related Disease Involving the Retroperitoneum: A Case Report (후복막강에 발생한 Immunoglobulin G4 연관 질환의 비전형적 발현: 증례 보고)

  • Byungsoo Kim;Jung Wook Seo
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.2
    • /
    • pp.487-492
    • /
    • 2021
  • Immunoglobulin G4 (IgG4)-related disease is a systemic disease characterized by dense lymphoplasmacytic infiltrates with abundant IgG4-positive plasma cells and fibroblast proliferation. The retroperitoneal involvement of IgG4-related disease usually appears as a soft-tissue mass covering the abdominal aorta or entrapping the ureters, resulting in hydronephrosis. Here, we present a case of IgG4-related disease with retroperitoneal involvement in a 75-yearold woman with an unusual manifestation. A preoperative computed tomography (CT) scan revealed an irregular infiltrative retroperitoneal mass invading the normal anatomic barriers, raising the suspicion of malignancy or inflammation. Contrast-enhanced CT revealed a homogeneous progressive enhancement of the mass.

Primary Malignant Peripheral Nerve Sheath Tumor of the Pulmonary Vein: A Case Report (폐정맥의 원발성 악성 말초신경초종: 증례 보고)

  • Hyun Woo;Hyeyoung Kwon;Jin Hwan Kim;Song Soo Kim;Hyung Kyu Park;Younju Rhee;Jae-Hyeong Park
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.6
    • /
    • pp.1384-1390
    • /
    • 2023
  • Primary masses rarely originate from the heart and great vessels, and a malignant peripheral nerve sheath tumor (MPNST) is extremely rare. A 76-year-old male with pleural effusion underwent contrast-enhanced computed tomography, which revealed a hypoattenuating mass involving the right pulmonary vein and left atrium. Ultrasonography showed that the mass originated from the right pulmonary vein. Surgical resection confirmed an MPNST that originated from the pulmonary vein. We report the first Korean case of a primary MPNST originating from the pulmonary vein. We have also described the radiologic findings suggestive of a pulmonary vein mass.

Imaging Assessment of Visceral Pleural Surface Invasion by Lung Cancer: Comparison of CT and Contrast-Enhanced Radial T1-Weighted Gradient Echo 3-Tesla MRI

  • Yu Zhang;Woocheol Kwon;Ho Yun Lee;Sung Min Ko;Sang-Ha Kim;Won-Yeon Lee;Suk Joong Yong;Soon-Hee Jung;Chun Sung Byun;JunHyeok Lee;Honglei Yang;Junhee Han;Jeanne B. Ackman
    • Korean Journal of Radiology
    • /
    • v.22 no.5
    • /
    • pp.829-839
    • /
    • 2021
  • Objective: To compare the diagnostic performance of contrast-enhanced radial T1-weighted gradient-echo 3-tesla (3T) magnetic resonance imaging (MRI) and computed tomography (CT) for the detection of visceral pleural surface invasion (VPSI). Visceral pleural invasion by non-small-cell lung cancer (NSCLC) can be classified into two types: PL1 (without VPSI), invasion of the elastic layer of the visceral pleura without reaching the visceral pleural surface, and PL2 (with VPSI), full invasion of the visceral pleura. Materials and Methods: Thirty-three patients with pathologically confirmed VPSI by NSCLC were retrospectively reviewed. Multidetector CT and contrast-enhanced 3T MRI with a free-breathing radial three-dimensional fat-suppressed volumetric interpolated breath-hold examination (VIBE) pulse sequence were compared in terms of the length of contact, angle of mass margin, and arch distance-to-maximum tumor diameter ratio. Supplemental evaluation of the tumor-pleura interface (smooth versus irregular) could only be performed with MRI (not discernible on CT). Results: At the tumor-pleura interface, radial VIBE MRI revealed a smooth margin in 20 of 21 patients without VPSI and an irregular margin in 10 of 12 patients with VPSI, yielding an accuracy, sensitivity, specificity, positive predictive value, negative predictive value, and F-score for VPSI detection of 91%, 83%, 95%, 91%, 91%, and 87%, respectively. The McNemar test and receiver operating characteristics curve analysis revealed no significant differences between the diagnostic accuracies of CT and MRI for evaluating the contact length, angle of mass margin, or arch distance-to-maximum tumor diameter ratio as predictors of VPSI. Conclusion: The diagnostic performance of contrast-enhanced radial T1-weighted gradient-echo 3T MRI and CT were equal in terms of the contact length, angle of mass margin, and arch distance-to-maximum tumor diameter ratio. The advantage of MRI is its clear depiction of the tumor-pleura interface margin, facilitating VPSI detection.

Renal Safety of Repeated Intravascular Administrations of Iodinated or Gadolinium-Based Contrast Media within a Short Interval

  • Chiheon Kwon;Koung Mi Kang;Young Hun Choi;Roh-Eul Yoo;Chul-Ho Sohn;Seung Seok Han;Soon Ho Yoon
    • Korean Journal of Radiology
    • /
    • v.22 no.9
    • /
    • pp.1547-1554
    • /
    • 2021
  • Objective: We aimed to investigate whether repeated intravascular administration of iodinated contrast media (ICM) or gadolinium-based contrast agents (GBCAs) within a short interval was associated with an increased risk of post-contrast acute kidney injury (PC-AKI). Materials and Methods: This retrospective study included 300 patients (mean age ± standard deviation, 68.5 ± 8.1 years; 131 male and 169 female) who had undergone at least one ICM-enhanced perfusion brain CT scan, had their baseline and follow-up serum creatinine levels available, and had not undergone additional contrast-enhanced examinations 72 hours before and after a time window of interest were included. The study population was divided into three groups: single-dose group and groups of patients who had received multiple contrast administrations in the time window of interest with the minimum contrast repeat interval either within 4 hours (0-4-hour group) or between 4 to 48 hours (4-48-hour group). Multivariable logistic regression analysis was conducted to evaluate the association between AKI and repeated ICM administrations. A similar supplementary analysis was performed including both ICM and GBCA. Results: When ICM was only considered ignoring GBCA, among 300 patients, 207 patients received a single dose of ICM, 58 had repeated doses within 4 hours (0-4-hour group), and 35 patients had repeated doses between 4 to 48 hours (4-48-hour group). Most patients (> 95%) had a baseline estimated glomerular filtration rate (eGFR) of ≥ 30 mL/min/1.73 m2. AKI occurred in 7.2%, 13.8%, and 8.6% of patients in the single-dose, 0-4-hour, and 4-48-hour groups, respectively. In the 0-4-hour and 4-48-hour groups, additional exposure to ICM was not associated with AKI after adjusting for comorbidities and nephrotoxic drugs (all p values > 0.05). Conclusion: Repeated intravascular administrations of ICM within a short interval did not increase the risk of AKI in our study patients suspected of acute stroke with a baseline eGFR of ≥ 30 mL/min/1.73 m2.

Incidence of Venous Thromboembolism in Pelvic and Acetabular Fractures in the Korean Population (한국인의 골반과 비구 골절에서 정맥 혈전색전증의 발병률)

  • Lee, Sang Ki;Lee, Jae Won;Hwang, Jung Joo
    • Journal of Trauma and Injury
    • /
    • v.26 no.3
    • /
    • pp.74-80
    • /
    • 2013
  • Purpose: There are no detailed reports on the incidence of venous thromboembolism (VTE) in pelvic and acetabular fractures in the Asian population. The purpose of this study was to investigate the incidence of VTE in pelvic and acetabular fractures in the Korean population. Methods: The cases of 67 Korean patients with pelvic and acetabular fractures treated at our hospital from January 2009 to February 2012 were analyzed retrospectively. Until May 2010, VTE screening was performed by contrast-enhanced computed tomography (CT) or ultrasonography (US) when the D-dimer value did not decline predictably, still exceeded $20{\mu}g/ml$ at 5 days after trauma and surgery, or increased to greater than $20{\mu}g/ml$ after a period of decline. After May 2010, contrast-enhanced CT and US were performed routinely irrespective of the D-dimer value. Physical prophylaxis was performed on all patients. The effects of the presence of a pelvic and/or acetabular fracture, and the effects of fracture type, accompanying injuries, and screening strategies on the incidences of VTE were investigated. Results: Overall, 26 patients(38.8%) were diagnosed with VTE and PTE in 14(20.9%). All were asymptomatic. Significantly higher incidences of VTE and PTE were observed in trauma patients with pelvic and acetabular fractures than in trauma patients without pelvic and acetabula fractures treated during the same period. No significant differences were observed in the incidences of VTE and PTE between patients with pelvic fractures, and patients with acetabular fractures or between patients with and without accompanying injuries. Compared with the previous screening strategy, the detection rates for VTE and PTE were higher for the newer screening strategy; however, the difference did not reach statistical significance. Conclusion: In the Korean population, we should be vigilant for a high incidence of VTE, especially PTE, in patients with pelvic and acetabular fractures.

A Case of Pulmonary Artery Sarcoma Presented as Cavitary Pulmonary Lesions

  • Min, Daniel;Lee, Ji-Hyun;Jeong, Hye-Cheol;Kim, Jung-Hyun;Shin, Suk-Pyo;Kim, Hong-Min;Han, Kyu Hyun;Jeong, Hye Yun;Kim, Eun-Kyung
    • Tuberculosis and Respiratory Diseases
    • /
    • v.76 no.3
    • /
    • pp.136-140
    • /
    • 2014
  • Pulmonary artery sarcoma (PAS) is a rare, poorly differentiated malignancy arising from the intimal layer of the pulmonary artery. Contrast-enhanced chest computed tomography (CT) is a good diagnostic modality that shows a low-attenuation filling defect of the pulmonary artery in PAS patients. An 18-year-old man was referred to our hospital for the evaluation and management of cavitary pulmonary lesions that did not respond to treatment. A contrast-enhanced CT of the chest was performed, which showed a filling defect within the right interlobar pulmonary artery. The patient underwent a curative right pneumonectomy after confirmation of PAS. Although lung parenchymal lesions of PAS are generally nonspecific, it can be presented as cavities indicate pulmonary infarcts. Clinicians must consider the possibility of PAS as well as pulmonary thromboembolism in patients with pulmonary infarcts. So, we report the case with PAS that was diagnosed during the evaluation of cavitary pulmonary lesions and reviewed the literatures.