• 제목/요약/키워드: Contrast transfer function

검색결과 58건 처리시간 0.027초

Hybrid Filter Based on Neural Networks for Removing Quantum Noise in Low-Dose Medical X-ray CT Images

  • Park, Keunho;Lee, Hee-Shin;Lee, Joonwhoan
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • 제15권2호
    • /
    • pp.102-110
    • /
    • 2015
  • The main source of noise in computed tomography (CT) images is a quantum noise, which results from statistical fluctuations of X-ray quanta reaching the detector. This paper proposes a neural network (NN) based hybrid filter for removing quantum noise. The proposed filter consists of bilateral filters (BFs), a single or multiple neural edge enhancer(s) (NEE), and a neural filter (NF) to combine them. The BFs take into account the difference in value from the neighbors, to preserve edges while smoothing. The NEE is used to clearly enhance the desired edges from noisy images. The NF acts like a fusion operator, and attempts to construct an enhanced output image. Several measurements are used to evaluate the image quality, like the root mean square error (RMSE), the improvement in signal to noise ratio (ISNR), the standard deviation ratio (MSR), and the contrast to noise ratio (CNR). Also, the modulation transfer function (MTF) is used as a means of determining how well the edge structure is preserved. In terms of all those measurements and means, the proposed filter shows better performance than the guided filter, and the nonlocal means (NLM) filter. In addition, there is no severe restriction to select the number of inputs for the fusion operator differently from the neuro-fuzzy system. Therefore, without concerning too much about the filter selection for fusion, one could apply the proposed hybrid filter to various images with different modalities, once the corresponding noise characteristics are explored.

다중 노출 영상을 이용한 영상의 화질 개선 알고리즘의 실시간 하드웨어 설계 (Real-Time Hardware Design of Image Quality Enhancement Algorithm using Multiple Exposure Images)

  • 이승민;강봉순
    • 한국정보통신학회논문지
    • /
    • 제22권11호
    • /
    • pp.1462-1467
    • /
    • 2018
  • 단일 노출 영상, 또는 다중 노출 영상을 사용하여 저조도 영상의 화질 개선 알고리즘이 수많이 연구되고 있다. 저조도 영상은 명암이 낮고, 잡음이 많아 피사체의 정보를 식별하기에 한계가 있다. 본 논문에서는 듀얼카메라로 촬영한 다중 노출 영상 2개를 이용하여 저조도 영상의 화질 개선하는 알고리즘의 하드웨어 설계를 제안한다. 제안하는 하드웨어 구조는 전달함수를 사용하여 프레임 메모리와 라인 메모리를 쓰지 않는 방식으로 실시간 처리로 설계되었다. 그리고 제안하는 하드웨어 설계는 Verilog로 설계했고, Modelsim을 사용하여 검증했다. 마지막으로 Xilinx사의 xc7z045-2ffg900을 목표 보드로 이용하여 FPGA를 구현했을 때 최대 동작 주파수 167.617MHz로 확인하였고, 영상 크기가 $1920{\times}1080$ 일 때, 소요된 총 클럭 사이클은 2,076,601이며 80.7fps로 실시간 처리가 가능하다.

해상도 타겟을 이용한 무인항공영상의 품질 평가 (Quality Evaluation of UAV Images Using Resolution Target)

  • 이재원;성상민
    • 한국지리정보학회지
    • /
    • 제22권1호
    • /
    • pp.103-113
    • /
    • 2019
  • 공간해상도는 영상품질을 평가하는 매우 중요한 파라미터들 중의 하나이다. 본 연구에서는 무인 항공영상의 품질평가 방안의 일환으로 bar target과 Siemens star 도형을 이용하여 공간해상도와 MTF(Modulation Transfer Function)를 평가하는 방안을 제시하였다. 이를 위하여 고정익 eBee(Canon IXUS)로는 비행고도 130m와 260m로 촬영하고, 회전익 GD-800(SONY NEX-5N)으로는 130m, Phantom 4 pro(FC 6310)는 90m 고도에서 각각 촬영하여 정사영상을 제작하여 공간해상도를 측정하였다. 실험결과 공간해상도는 Siemens star와 Bar target 모두에서 카메라에 관계없이 정확히 비행고도에 비례하여 낮아짐을 알 수 있었다. 즉, 서로 상이한 카메라가 탑재된 Canon IXUS(eBee)와 SONY NEX-5N(GD-800)으로 130m의 동일 고도에서 촬영한 영상의 공간해상도는 4.1cm로 동일하였으며, eBee 260m의 경우에는 공간해상도가 8.0cm이었다. 아울러 Siemens star로 측정한 해상도가 Bar target에 비하여 모든 고도에서 1~2cm 가량 낮았다. 영상의 해상도와 명암 정보를 동시에 나타내는 MTF의 ${\sigma}_{MTF}$ 측정에서도 비행고도에 비례하는 일반적인 경향을 알 수 있었다. 하지만 130m 동일고도에서 SONY NEX-5N(GD-800)의 ${\sigma}_{MTF}$ 는 0.36이고, Canon IXUS(eBee)는 0.59로 카메라 성능이 더 좋은 SONY NEX-5N(GD-800)이 우수함을 알 수 있었다. 본 연구의 결과는 무인항공영상의 공간해상도 분석과 품질의 신뢰도 향상에 기여할 것으로 기대한다.

Physical Modeling of Chemical Exchange Saturation Transfer Imaging

  • Jahng, Geon-Ho;Oh, Jang-Hoon
    • 한국의학물리학회지:의학물리
    • /
    • 제28권4호
    • /
    • pp.135-143
    • /
    • 2017
  • Chemical Exchange Saturation Transfer (CEST) imaging is a method to detect solutes based on the chemical exchange of mobile protons with water. The solute protons exchange with three different patterns, which are fast, slow, and intermediate rates. The CEST contrast can be obtained from the exchangeable protons, which are hydroxyl protons, amine protons, and amide protons. The CEST MR imaging is useful to evaluate tumors, strokes, and other diseases. The purpose of this study is to review the mathematical model for CEST imaging and for measurement of the chemical exchange rate, and to measure the chemical exchange rate using a 3T MRI system on several amino acids. We reviewed the mathematical models for the proton exchange. Several physical models are proposed to demonstrate a two-pool, three-pool, and four-pool models. The CEST signals are also evaluated by taking account of the exchange rate, pH and the saturation efficiency. Although researchers have used most commonly in the calculation of CEST asymmetry, a quantitative analysis is also developed by using Lorentzian fitting. The chemical exchange rate was measured in the phantoms made of asparagine (Asn), glutamate (Glu), ${\gamma}-aminobutyric$ acid (GABA), glycine (Gly), and myoinositol (MI). The experiment was performed at a 3T human MRI system with three different acidity conditions (pH 5.6, 6.2, and 7.4) at a concentration of 50 mM. To identify the chemical exchange rate, the "lsqcurvefit" built-in function in MATLAB was used to fit the pseudo-first exchange rate model. The pseudo-first exchange rate of Asn and Gly was increased with decreasing acidity. In the case of GABA, the largest result was observed at pH 6.2. For Glu, the results at pH 5.6 and 6.2 did not show a significant difference, and the results at pH 7.4 were almost zero. For MI, there was no significant difference at pH 5.6 or 7.4, however, the results at pH 6.2 were smaller than at the other pH values. For the experiment at 3T, we were only able to apply 1 s as the maximum saturation duration due to the limitations of the MRI system. The measurement of the chemical exchange rate was limited in a clinical 3T MRI system because of a hardware limitation.

직접 및 간접변환 방식의 디지털 유방 X선 촬영시스템의 영상화질 비교 연구 (Comparison Study of Image Quality of Direct and Indirect Conversion Digital Mammography System)

  • 박혜숙;오유나;조희정;김상태;최유나;김희중
    • 한국의학물리학회지:의학물리
    • /
    • 제21권3호
    • /
    • pp.239-245
    • /
    • 2010
  • 본 연구의 목적은 직 간접 변환방식 검출기를 사용한 디지털 유방 X선 촬영시스템의 영상 화질을 비교하고 평가함에 있다. 영상의 정량적인 분해능을 나타내는 변조전달함수(MTF), 노이즈 특성을 나타내는 정규화된 잡음력 스펙트럼(NNPS), 그리고 신호 대 잡음비 성능을 나타내는 양자검출효율(DQE)인자를 이용하여 영상 화질평가를 하였다. DQE는 IEC 62220-1-2 규약에 따라 edge 팬텀을 사용한 MTF 도출을 이용하여 계산되었다. 대조도 대 노이즈비(CNR) 측정은 한국의료영상품질관리원에서 제시한 가이드라인에 따라 측정되었다. 직접 변환방식 검출기가 간접 변환방식 검출기에 비해 공간주파수별로 MTF와 DQE 값이 높은 것으로 측정되었다. 동일한 평균유선선량(AGD)일 때 직접 변환방식의 검출기는 더 높은 CNR값을 보였다. 공간주파수별로 높은 DQE 값을 갖는 직접 변환방식 검출기는 디지털 유방 X선 촬영시스템에 있어서 향상된 영상 화질과 적은 환자선량을 제공할 것이다.

디지털 흉부영상에서 자동노출제어 및 감도변화를 이용한 영상품질의 정량적인 평가 (Quantitative Evaluation of Image Quality using Automatic Exposure Control & Sensitivity in the Digital Chest Image)

  • 이진수;고성진;강세식;김정훈;김동현;김창수
    • 한국콘텐츠학회논문지
    • /
    • 제13권8호
    • /
    • pp.275-283
    • /
    • 2013
  • 자동노출제어장치를 사용하는 흉부 후전 검사는 이온전리조의 선택에 따라 환자가 받는 피폭선량이 달라진다. 본 논문에서는 자동노출제어장치의 이온전리조의 선택에 따른 최적의 진단 영상을 획득하면서 피폭선량을 최소화하는 방안에 대해 연구하였다. 실험방법은 흉부 후전 검사와 동일한 조건으로 자동노출제어장치의 이온전리조 선택과 감도변화에 따라 실험하였다. 이온전리조의 상단 2개, 하단 1개의 센서를 on/off 선택에 따라 7가지의 경우로 나누어 각각 5회씩 측정하여 평균값을 구하고 피폭선량을 산출하였다. 영상평가는 변조전달함수, 최대신호 대 잡음비, 평균제곱근, 신호 대 잡음비, 대조도 대 잡음비, 평균대표준편차비를 각각 측정하여 평가를 시행하였다. 실험결과 피폭선량 평가에서 이온전리조 상단 2개를 선택한 경우가 다른 조합에 비해 가장 낮은 선량을 나타내었고, 해상력 평가결과로는 감도 625(High)에서 상단2개를 선택한 영상이 두 번째로 높은 공간주파수 1.343 lp/mm를 나타내었다. 상단 2개를 선택한 영상의 평균제곱근 결과값이 두 번째로 낮게 나타났으며, 신호 대 잡음비, 대조도 대 잡음비, 평균 대 표준편차비는 두 번째로 높은 결과값을 나타내었다. 그리고 감도가 증가함에 따라 피폭선량은 감소하였으며, 영상품질 측면에서도 보다 우수한 영상을 얻을 수 있었다. 따라서 피폭선량을 최소화하고, 최적의 의료 영상을 얻기 위해서는 감도 625(High)에서 이온전리조 상단 2개를 선택하는 것이 임상적으로 유용할 것으로 사료된다.

반복적 재구성 알고리즘과 관전류 자동 노출 조정 기법의 CT 영상 화질과 선량에 미치는 영향: 관상동맥 CT 조영 영상 프로토콜 기반의 팬텀 실험 (Effects of Iterative Reconstruction Algorithm, Automatic Exposure Control on Image Quality, and Radiation Dose: Phantom Experiments with Coronary CT Angiography Protocols)

  • 하성민;정성희;장혁재;박은아;심학준
    • 한국의학물리학회지:의학물리
    • /
    • 제26권1호
    • /
    • pp.28-35
    • /
    • 2015
  • 본 논문에서는 반복적 구성 기법과 관전류 노출자동조절 기법이 영상의 화질과 방사선량에 미치는 영향을 관상동맥 전산화단층촬영 혈관조영 영상(coronary computed tomography angiography, CCTA)을 대상으로 팬텀 실험에 기반하여 평가하고자 한다. 이를 위하여 미국 의학물리학회(American Association of Physics in Medicine) 표준의 성능 평가 팬텀을 320 다중검출열 CT로써 촬영하였다. 80 kVp, 100 kVp, 120 kVp의 관전압에 있어서, 관전류 노출자동조절 기법은 저선량 목표 표준편차(SD=44)와 고선량(목표 표준편차=33)의 두 가지 설정으로써 촬영하였다. 재구성 변수로서는 필터보정 역투영(FBP)와 반복적 재구성 방법을 설정하여, 전부 12개의 재구성 영상을 획득하였다(12=3 (80, 100, 120 kVp)${\times}2$ (저선량(목표SD=44), 고선량(목표SD=33))${\times}2$ (필터보정역투영, 반복적 재구성). 영상의 화질은 잡음의 세기(표준편차), 변조전달함수, 대조대잡음비(CNR)에 의하여 평가하였으며, 관전압과 관전류 노출자동조절 기법에서의 목표 선량과 대소 및 재구성 기법의 선택이 화질과 방사선량에 미치는 영향을 관찰하였다. 반복적 재구성 기법은 필터보정역투영 기법보다 영상 잡음을 대폭 감소시켰으며 이는 저선량의 경우 더욱 뚜렷하였다. 즉, 잡음의 세기는 관전류 노출자동조절의 설정이 고선량 (목표SD=33)과 저선량(목표SD=44)인 경우, 각각 평균 38%와 평균 46% 감소하였다. 반복적 재구성 기법에 의하여, 변조전달 함수에 의한 공간적 해상도의 평가에 있어서 미약한 감소를 보였으나, 이로써 잡음 저감과 대조대잡음비(CNR)에 있어서의 현저한 개선을 상쇄할 정도의 영향에는 미치지 못 하였다. 결과적으로, 관상동맥 전산화단층촬영 혈관조영 영상의 획득에서 있어서, 반복적 재구성 기법과 관전류 노출자동조정 기법을 동시에 사용하는 것은 영상의 화질을 개선하면서 공간적 해상도의 저하 등 그 부작용은 최소화함으로써, 합리적으로 획득 가능한 한 최소한의 선량 (ALARA)의 원칙에 충실한 실제 임상적 효과를 의미한다고 기대할 수 있다.

소아 SPECT/CT 검사를 위한 최저조건에서의 피폭선량측정 및 팬텀의 영상평가 (Abosrbed Dose Measurements and Phantom Image Ecaluation at Minimum CT Dose for Pediatric SPECT/CT Scan)

  • 박찬록;최진욱;조성욱;김진의
    • 핵의학기술
    • /
    • 제18권1호
    • /
    • pp.82-88
    • /
    • 2014
  • SPECT/CT로 소아 복부를 검사 하는데 있어 저선량 CT 조건에 따른 흡수선량을 측정하고 SPECT와 CT 영상의 질을 평가하고, 우수한 영상의 질을 유지하면서 최저의 흡수 선량을 받을 수 있는 tube voltage (kVp)와 tube current (mA)의 설정 방향을 알아보는데 목적을 두었다. 장비는 Discovery NM/CT 670을 사용하였다. PMMA phatom을 이용하여 80, 100 kVp 10, 15, 20, 25 mA의 조건을 설정하여 중심방향과 주변방향(3, 6, 9, 12시 방향의 평균) 의 흡수선량을 측정하였고, 그에 따른 image를 SNRD로 평가 하였다. CT QA performance phantom으로 CT image의 resolution을 MTF로 나타내었고, jaszczak phantom을 hot sphere와 배후방사의 비를 $^{99}mTc$을 1:8로 주입하여 4개의 sphere에 대한 SPECT image를 CNR로 평가하였다. 선량측정에서는 주변방향의 선량이 중심방향 선량보다 평균 7% 높게 측정되었으며, SNRD는 조건에 따라 유의한 차이가 없었으며 Resolution 평가에서는 0.385 lp/mm 기준으로 100 kVp가 80 kVp보다 평균 12% 재현성이 우수하였으며, jaszczak phantom을 이용해서 CT를 기반으로 한 attenuation correction 된 SPECT image를 CNR로 평가한 결과 CT조건의 변화와 무관하게 4개의 sphere 모두 유의한 차이를 보이지 않았다. 본 연구는 SPECT/CT 검사에서 최저의 흡수선량을 유지하고 우수한 영상의 질을 획득하는데 추가적인 연구가 필요할 것으로 사료된다.

  • PDF