• Title/Summary/Keyword: Contrast examination

Search Result 456, Processing Time 0.026 seconds

The Study on the Contents and Satisfaction of Oriental Medicine Examination Program (한방건강검진 프로그램의 내용과 참가자들의 만족도에 관한 연구)

  • Lee Eun-Kyoung;Jahng Doo-Sub;Song Yung-Sun;Lee Ki-Nam
    • Journal of Society of Preventive Korean Medicine
    • /
    • v.6 no.1
    • /
    • pp.51-95
    • /
    • 2002
  • 1. As a point at issue of occidental medicine examination, followings have been indicated, 1) Occidental medical examination is performed by mainly test and instrument and therefore, role of doctors could be excluded and it could be diagnosed only for target disease and 2) in Korea, it could not be conducted in public medical system and therefore improvement effect of public health promotion could not be made due to increase of total medical expenses and infirmity of post management. These points are substantial limit of paradigm resided in occidental medicine and also problem caused by unique characteristics of medical system of Korea. In Korea, result of occidental medical examination show increased health risk from aged thirties and major diagnosed diseases are circulatory disease or chronic disease such as hepatic, hyperlipemic, hypertensional disease and diabetes, etc. Accounting that those chronic disease make a role as major public health risk, it is difficult that medical examination by only occidental medicine make effect on public health promotion. 2. Characteristics of oriental medicine examination could be summarized as diagnosis (information acquisition based on the facts) and demonstration (speculation based on acquired information) and in addition, quadruple diagnosis, as a medical examination method, include test as well as basic examination. Accounting on oriental medical examination, principally it is performed by independent herbalist and therefore, herbalist could acquire systemic result during first medical examination. Based on the theory of inner-outer examination, oriental medical examination has a principle of universe theory, systemic analysis of quadruple diagnosis, demonstration & reasoning. In addition, root of oriental medical examination could be found in pre-disease theory, a principal theory of oriental medicine. Pre-disease service could prove the advantage of oriental medicine in medical examination activities and therefore, it is needed that content of oriental medical examination should be actualized in current medical system. 3. In this study, oriental medical examination program, comprised of pulse-diagnosis, contrast muscular taking and medical consultation of herbalist is progressed communally with occidental medical examination. As pre-examination, questionary was given of general characteristics, health promoting life style, physical constitution and subjective symptom of musculoskeletal system. In addition, post-examination notification was given to subjects about health promoting control, physical constitution regimen and management of musculoskeletal system. During this study program, verification was conducted for input of acquired information and difference of each information after analysis and in addition, performed was analysis of factor influencing health promoting life style and musculoskeletal subjective symptom and evaluation of relationship of physical constitution and health promoting life study. In addition, it was verified of difference between musculoskeletal subjective symptom and result of muscle contrast picture evaluation. 4. Evaluation of oriental medical examination model is divided into 2 categories of oriental medical examination-consultation and result evaluation -post management. Oriental medical examination-consultation demands establishment of examination system, standardization of examination and establishment of examination form and in addition, it should be admitted as enlarged examination assists systemic quadruple diagnosis of herbalist not a key of oriental medical examination. In addition, information acquisition for research purpose should be performed according to the systemic research plan based on the separation of questionary for examination purpose and research purpose. For evaluation of the result, it was concluded that needed are result evaluation meets oriental medical system and post-notification system, informing health management information, based on examination result. 5. Accounting on satisfaction for oriental medical examination model, affirmative reply was much higher (66%) than negative (8.64%). Satisfaction of each area was in order of consultation of herbalist, systemic muscle contrast taking, pulse examination, post-notification and questionary fill-up and dissatisfaction was in order of post-notification, questionary fill-up, consultation of herbalist, systemic muscle contrast taking and pulse measurement. Satisfaction for collaborative examination of occidental and oriental medicine was over 60% and over 75% hope oriental examination would be included in later medical examination program. Based on this result, collaborative examination including occidental and oriental medicine could increase satisfaction of subjects for medical examination program.

  • PDF

Usefulness of Audio-visual Methods that is used to Customer to Help Smooth Public Prosecutor at CT Examination (CT Scan Positioning시 고객의 검사진행의 이해를 돕기 위한 시청각 자료의 유용성)

  • Ahn, Hyeong-Taek;Jeon, Jung-Keun
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.10 no.2
    • /
    • pp.17-22
    • /
    • 2008
  • It is to improve customer satisfaction measurement and CT Scan process without delay of examination time when is using Scan positioning time(Planning time) that time is happened always between research reactor CT examination to increase fear and examination satisfaction by the customer's comprehension tribe which get the latest contrast enhancement CT examination. Needs and interests that customer wants to compose visual and auditory Contents to be played to Scan positioning time did questionnaire about curiosity later before CT examination to 600 people for October - November 2 months of 2006 to customer whole that get CT examination on source. Data getting through questionnaire investigated examination comprehension and satisfaction through questionnaire after experiment Scan Positioning to 500 coming to help customers to be source CT examination for 3 months February December - 2007 year in 2006 manufacturing Voice and Visual announce media for reference. To customer who interest degree appeared, and answers preparatory audit from preparatory audit about curiosity of CT examination customer to order of examination time required(43%), contrast media side effect(26%), examination region(20%), breath(10%), etc..(1.5%) audio-visual materials in questionnaire that attain after do reclamation among examination age, sex, reception type of irrelatively in 91% of target increase of hailing degree and examination satisfaction appear. Searched that customer hailing and satisfaction are increased greatly when use of audio-visual materials in satisfaction result that use CT Positioning delay time. In experiment process, It took lacking part by method that use hearing in case of do not use sight as is unavoidable in subject position or old age. Through this, audio-visual materials could analogize that it is more useful method that use sight and hearing at the same time.

  • PDF

Studies of the side effects on using the contrast media: It's characteristic and management (조영제를 사용하는 환자의 부작용: 특성과 관리에 관한 연구)

  • Seon, Jong-Ryoul;Yoo, Se-Jong
    • Journal of the Korea Safety Management & Science
    • /
    • v.16 no.4
    • /
    • pp.427-431
    • /
    • 2014
  • The purpose of this study is to monitor the current adverse reactions in administering CT contrast agents at general hospitals and also to suggest the practical guidelines to minimize the risk and to show the successful patient management. At four Dajeon city general hospitals, the contrast agents were administered in 646,828 cases and the overall prevalence of adverse reactions was 4,110 cases from January 2010 to December 2013. However, we excluded the two hospitals' 3,658 cases because the patients' data was inadequate. Consequently, the case surveys on the rest of 452 cases have been studied and submitted. After comparing the patients with a control group, we evaluated that the key factors of the adverse reactions were the gender and age difference of the patients, the examination period, the examination method, the quantity and administrating speed of the contrast agents. Even though the four general hospitals have their own management systems on adverse reactions, but their systems were not satisfying. To improve the quality of the management systems and to investigate further cases, some hospital administration procedures on the subject should be systemized and general hospitals should follow the recommended procedures. Moreover, the existing three-year-term evaluation should not only judge the adverse reaction management but also conclude some details on the sub criteria of the evaluation. The details on the sub criteria include the contrast agent characters, the quantity and administrating speed of the drug, the incidents' occurred time, an anamnesis; a case history, the medical history of the patients and the reaction occurring body parts, and the examination title. The details of the medical examiners are also added to the sub criteria.

Analysis on the Entrance Surface Dose and Contrast Medium Dose at Computed Tomography and Angiography in Cardiovascular Examination (심장혈관검사에서 전산화단층검사와 혈관조영검사의 입사표면선량 및 조영제 사용량에 관한 분석)

  • Seo, Young-Hyun;Han, Jae-Bok;Choi, Nam-Gil;Song, Jong-Nam
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.535-541
    • /
    • 2016
  • This study aimed to identify dose reduction measures by retrospectively analyzing the entrance surface dose at computed tomography and angiography in cardiovascular examination and to contribute the patients with renal impairmend and a high probability of side effects to determine the inspection's direction by measuring the contrast usages actually to active actions for the dose by actually measuring the contrast medium dose. The CTDIvol value and air kerma value, which are the entrance surface doses of the two examinations, and the contrast medium dose depending on the number of slides were compared and analyzed. This study was conducted in 21 subjects (11 males; 10 females) who underwent Cardiac Computed Tomographic Angiography (CCTA) and Coronary Angiography (CAG) in this hospital during the period from May 2014 to May 2016. The subject's age was 48~85 years old (mean $65{\pm}10$ years old), and the weight was 37.6~83.3 kg (mean $63{\pm}6kg$). Dose reduction could be expected in the cardiovascular examination using CCTA rather than in the examination using CAG. In terms of contrast medium dose, CAG used a smaller dose than CCTA. In particular, as the number of slides increases at CAG, the contrast medium dose increases. Therefore, in order to reduce the contrast medium dose, the number of slides suitable for the scan range must be selected.

Evaluation of Image Quality and Radiation Dose for Filtered Back-Projection and Iterative Reconstruction Algorithm in Abdominal Computed Tomography Protocol (복부 CT 프로토콜에서 필터 보정 역투영법과 반복적 재구성기법에 따른 화질 및 선량에 관한 연구)

  • Oh, Jeong-Min;Seo, Hyeon-Ji;Kim, Yung-Kyoon;Han, Dong-Kyoon
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.7
    • /
    • pp.1065-1072
    • /
    • 2021
  • In Computed Tomography, abdominal examination showed the highest proportion of use, and effort of reducing the radiation dose is required. Recently introduced Iterative Reconstruction(IR) is repetitive reconstruction technique of Computed Tomography. SIEMENS' IR, ADMIRE and GE's IR, ASIR-V, were used in this examination. Noise, % Contrast, and High contrast resolution were measured by using ACR phantom for image quality evaluation. In addition, CTDIvol and DLP displayed in the CT device were used for dose evaluation. When FBP and IR were compared, stage 2 to stage 5 of ADMIRE and 10, 30, 50, 70, and 90% of ASIR-V were applied, noise could be reduced from a minimum of 0.46 to a maximum of 2.38 in ADMIRE compared to FBP, and noise from a minimum of 0.51 to a maximum of 2.5 in ASIR-V compared to FBP. Also, % Contrast and High contrast resolution of FBP and IR were no statistical difference. When IR was used for abdominal CT examination, the radiation dose of ADMIRE is reduced by 25.39% compared to the radiation dose of FBP. Also, the radiation dose of ASIR-V is reduced by 16.61% compared to the radiation dose of FBP. In conclusion, it is believed that if IR is applied during abdominal CT examination, the radiation dose can be reduced without deteriorating the image quality.

Usefulness of DECT Application for Compensation of Image Contrast Difference According to CT Contrast Agent Density (CT 조영제 농도에 따른 영상 대조도 차 보상을 위한 DECT 적용의 유용성)

  • Hyeon-Ju Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.3
    • /
    • pp.417-422
    • /
    • 2023
  • In this study, normal saline was diluted with the contrast medium at a certain ratio for the purpose of reducing the image quality poor and side effects caused by the contrast medium during CT examination. At this time, by finding the energy level of DECT that can compensate for the decrease in contrast of the image according to the degree of dilution, the usefulness of applying DECT for compensating the difference in image contrast was investigated through comparative analysis by applying SNR, CNR, and SSIM. As a result, when a dilution ratio of 4 (contrast medium): 6 (normal saline) and the energy level of DECT of 65 keV were applied, the contrast difference was the most similar to that when using the undiluted contrast medium. At this time, SNR was 813.71 ± 37.6, CNR was the highest at 921.87 ± 17.1, and SSIM index was measured at 0.851, which is the most similar to 1. The results of this study are meaningful in providing basic information for finding the appropriate dilution rate and energy level for each examination site through future clinical studies. It is believed that it can be reduced.

The Effect of Contrast Agent on the Change of Hepatic Uptake of 99mTc-Mebrofenin in Patients with Liver Transplantation

  • Seung-Hun Yeom;Sang-Hyeong Kil;Yeong-Hyeon Lim;Gwang-Yeol Park;Gyeong-Nam Cho;Seong-Muk Cho;Ji-Ho Seong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.28 no.1
    • /
    • pp.23-29
    • /
    • 2024
  • Purpose: 99mTc-mebrofenin hepatobiliary scintigraphy (HBS) is an important and clinically useful diagnostic imaging study for detecting complications after liver transplantation. CT contrast agents due to their high atomic numbers, lead to a decrease in gamma ray count rates. This study investigated the impact of CT contrast agents on the uptake of 99mTc-mebrofenin in the liver. Materials and Methods: The quantitative HBS was performed on sixty-two liver transplantation patients (male:female=36:26), with a mean age of 59.4±6.4 years. Statistical comparison of hepatic uptake reduction ratio (HURR%) before and after the injection of CT contrast agents was performed using a paired t-test. Results: Hepatic uptake of the reduction ratio was 94.47±3.65% for the pre-CT contrast agents and 92.17±4.00% for the post-CT contrast agents. HURR% after CT contrast agent injection showed a statistically significant difference compared to before the injection (t=11.09, P<0.001). Conclusion: It will be necessary to pay attention when examining the HBS of patients with liver transplantation after the injection of CT contrast medium. It is advisable to schedule the examination on a different day to prevent residual contrast medium in the body from interfering with the quantitative evaluation of the nuclear medicine examination.

Digital contrast subtraction radiography for proximal caries diagnosis (인접면 치아우식 진단을 위한 디지털 방사선 조영 공제술)

  • Kang Byung-Cheol;Yoon Suk-Ja
    • Imaging Science in Dentistry
    • /
    • v.32 no.3
    • /
    • pp.123-127
    • /
    • 2002
  • Purpose : To determine whether subtraction images utilizing contrast media can improve the diagnostic performance of proximal caries diagnosis compared to conventional periapical radiographic images. Materials and Methods: Thirty-six teeth with 57 proximal surfaces were radiographied using a size #2 RVG-ui sensor (Trophy Radiology, Marne-la-Vallee, France). The teeth immersed in water-soluble contrast media and subtraction images were taken. Each tooth was then sectioned for histologic examination. The digital radiographic images and subtraction images were examined and interpreted by three dentists for proximal caries. The results of the proximal caries diagnosis were then verified with the results of the histologic examination. Results: The proximal caries sensitivity using digital subtraction radiography was significantly higher than simply examining a single digital radiograph. The sensitivity of the proximal dentinal carious lesion when analyzed with the subtraction radiograph and the radiograph together was higher than with the subtraction radiograph or the radiograph alone. Conclusion: The use of subtraction radiography with contrast media may be useful for detecting proximal dentinal carious lesions.

  • PDF

Congenital Peritoneopericardial Diaphragmatic Hernia in a Dog (개에서의 선천성 복막-심낭 횡경막허니아 1예)

  • Jeong, Seong-Mok
    • Korean Journal of Veterinary Research
    • /
    • v.42 no.3
    • /
    • pp.393-396
    • /
    • 2002
  • A 5 kg, seven-month-old, female Pekingese dog was presented to Seoul National University Veterinary Medical Teaching Hospital with the history of anorexia and exercise intolerance. Muffled cardiac sound and mild abdominal pain were detected in the physical examination. In positive contrast peritoneography, contrast medium was observed in enlarged pericardial sac through the diaphragm. According to the history taking, physical examination and contrast radiographic study, the dog was diagnaosed congenital peritoneopericardial diaphragmatic hernia. Following midline celiotomy, herniated falciform ligament and greater omentum were repositioned to abdrminal cavity. The diaphragmatic defect was closed with absorbable suture. Clinical signs related to peritoneopericardial hernia disappeared immediately after surgical treatment. There had been no evidence of recurrence of the peritoneopericardial hernia for 1 year.

Estimation of Appropriate Number of Radiologic Technologist Based on Analysis of Time Required for Computed Tomography (전산화단층촬영의 소요시간 분석에 기반한 방사선사의 적정인력 산정에 관한 연구)

  • Lee, Ki-Baek;Kim, Yung-Kyoon;Kim, Eun-Hye;Kim, Yon-Min
    • Journal of radiological science and technology
    • /
    • v.45 no.3
    • /
    • pp.213-223
    • /
    • 2022
  • Although the number of computed tomography(CT) is increasing every year, it is insufficient to establish appropriate workload calculation standards of radiologic technologist to provide optimal medical services to patients, such as patient safety management and infection management. The purpose of this study is to present guidelines for calculating the appropriate workload of radiologic technologist by analyzing the work flow of CT procedures and the time required for CT examination in major hospitals. As for the study subjects and methods, the appropriate process for each step of CT examination was investigated to systematically present the process and time required for the actual examination, and the CT procedure time of 104,105 adult patients and 465 pediatric patients under the age of 6 were analyzed. For the time required, data according to the use of contrast medium, procedure type, and adult/child were collected and compared. The test time of CT examination using contrast medium took about 13 minutes when one radiologic technologist worked and about 9 minutes when two radiologic technologists worked. The time required for the procedures were statistically significant depending on the presence or absence of contrast medium, multi-phase procedure, and patient age (considering pediatric patients). As a result, in order to thoroughly perform patient safety and infection management, the appropriate workload increased by about 40% when there were two radiologic technologists. The limit workload was an average of 32 people per day with one radiologic technologist per 15 minutes, and 48 people per day with two radiologic technologist per 10 minutes. This is a marginal workload, and in the case of procedures that require more time to acquire radiographic images, the interval between reservations should be widened.