• 제목/요약/키워드: Contrast Analysis

검색결과 3,295건 처리시간 0.035초

Added Value of Contrast Leakage Information over the CBV Value of DSC Perfusion MRI to Differentiate between Pseudoprogression and True Progression after Concurrent Chemoradiotherapy in Glioblastoma Patients

  • Pak, Elena;Choi, Seung Hong;Park, Chul-Kee;Kim, Tae Min;Park, Sung-Hye;Won, Jae-Kyung;Lee, Joo Ho;Lee, Soon-Tae;Hwang, Inpyeong;Yoo, Roh-Eul;Kang, Koung Mi;Yun, Tae Jin
    • Investigative Magnetic Resonance Imaging
    • /
    • 제26권1호
    • /
    • pp.10-19
    • /
    • 2022
  • Purpose: To evaluate whether the added value of contrast leakage information from dynamic susceptibility contrast magnetic resonance imaging (DSC MRI) is a better prognostic imaging biomarker than the cerebral blood volume (CBV) value in distinguishing true progression from pseudoprogression in glioblastoma patients. Materials and Methods: Forty-nine glioblastoma patients who had undergone MRI after concurrent chemoradiotherapy with temozolomide were enrolled in this retrospective study. Twenty features were extracted from the normalized relative CBV (nCBV) and extraction fraction (EF) map of the contrast-enhancing region in each patient. After univariable analysis, we used multivariable stepwise logistic regression analysis to identify significant predictors for differentiating between pseudoprogression and true progression. Receiver operating characteristic (ROC) analysis was employed to determine the best cutoff values for the nCBV and EF features. Finally, leave-one-out cross-validation was used to validate the best predictor in differentiating between true progression and pseudoprogression. Results: Multivariable stepwise logistic regression analysis showed that MGMT (O6-methylguanine-DNA methyltransferase) and EF max were independent differentiating variables (P = 0.004 and P = 0.02, respectively). ROC analysis yielded the best cutoff value of 95.75 for the EF max value for differentiating the two groups (sensitivity, 61%; specificity, 84.6%; AUC, 0.681 ± 0.08; 95% CI, 0.524-0.837; P = 0.03). In the leave-one-out cross-validation of the EF max value, the cross-validated values for predicting true progression and pseudoprogression accuracies were 69.4% and 71.4%, respectively. Conclusion: We demonstrated that contrast leakage information parameter from DSC MRI showed significance in differentiating true progression from pseudoprogression in glioblastoma patients.

The Risk Factors for Developing Contrast-induced Nephropathy after the Evaluation of Trauma Patients at a Regional Trauma Center in Korea

  • An, Yoo Mi;Park, Soon Chang;Kim, Hyung Bin;Cho, Young Mo;Lee, Dae Seop;Kim, Yong In;Han, Sang Kyun
    • Journal of Trauma and Injury
    • /
    • 제29권4호
    • /
    • pp.124-128
    • /
    • 2016
  • Purpose: Computed tomography (CT) with intravenous (IV) contrast is an important step in the evaluation of trauma patients; however, the risk factors for contrast-induced nephropathy (CIN) in these patients remain unclear. This study determined the rate of CIN in trauma patients at a regional trauma center in Korea and identified the risk factors for developing CIN. Methods: We retrospectively reviewed the medical records of 138 patients for the patient demographics, creatinine levels, and vital signs. CIN was defined as an increase in creatinine by 0.5 mg/dL from admission after undergoing CT with IV contrast. Results: Of the patients, 7.2% developed CIN during their admission after receiving IV contrast for CT. In the multivariate analysis, only the creatinine level at presentation (Adjusted odds ratio [aOR], 5.944; 95% confidence interval [CI], 1.486-23.733; p=0.012) and an injury severity score (ISS) greater than 22 (aOR, 1.096; 95% CI, 1.021-1.176; p=0.011) were independently associated with the risk of CIN. Conclusion: CIN is uncommon in trauma patients following CT with IV contrast. The creatinine level at presentation and ISS were independent risk factors for developing CIN in trauma patients.

조영제 자동주입기를 활용한 자기공명영상 동적검사 시 실린지 재사용의 문제 (Syringe Reuse Issues in Automated Contrast Injection System in Dynamic Magnetic Resonance Imaging)

  • 손순룡
    • 한국콘텐츠학회논문지
    • /
    • 제19권11호
    • /
    • pp.445-450
    • /
    • 2019
  • 본 연구는 자기공명영상 동적검사 시 자동주입기의 사용에 따라 조영제 역류로 인한 생리식염수의 오염 현상을 실험적으로 증명함으로써, 오염된 실린지 재사용 문제의 심각성을 인식시키고자 하였다. 연구방법은 조영제 주입 전 생리식염수와 주입 후 생리식염수를 각각 채취한 다음, T1 강조영상을 획득하여 신호강도를 측정하여 비교하였다. 생리식염수의 주입 후 신호강도가 주입 전에 비해 523.43% 통계적으로 높게 나타났다(p<0.05). 이는 조영제 주입에 따른 압력에 의해 조영제가 관을 통해 역류하여 압력이 낮은 반대쪽 생리식염수를 오염시킨 것으로 분석되었다. 결론적으로 조영제 주입 시 사용하는 실린지는 조영제 역류로 인해 교차오염이 발생하므로 정량적 분석을 위한 검사 시 동일한 환자의 검사라도 검사순서를 변경하거나 실린지를 교체하여 오류를 방지해야 한다.

뇌전이 환자의 조영 증강 후 지연 FLAIR 영상의 유용성 (Patients with brain metastases the usefulness of contrast-enhanced FLAIR images after delay)

  • 변재후;박명환;이진완
    • 대한디지털의료영상학회논문지
    • /
    • 제16권1호
    • /
    • pp.13-19
    • /
    • 2014
  • Purpose: FLAIR image is beneficial for the diagnosis of various bran diseases including ischemic CVS, brain tumors and infections. However the border between the legion of brain metastasis and surrounding edema may not be clear. Therefore, this study aims to investigate the practical benefits of delayed imaging by comparing the image from a patient with brain metastasis before a contrast enhancement and the image 10 minutes after a contrast enhancement. Materials and methods: Of the 92 people who underwent MRI brain metastases in suspected patients 13 people in three patients there is no video to target the 37 people confirmed cases, and motion artifacts brain metastases in our hospital June-December 2013, 18 people measurement position except for the three incorrect patient (male: 11 people, female: 7 people, average age: 60 years) in the target, test equipment, 3.0T MR System (ACHIEVA Release, Philips, I was 8ChannelSENSE Head Coil use Best, and the Netherlands). TR 11000 ms, TE 125 ms, TI2800 ms, Slice Thickness 5 mm, gap 5 mm, is a Slice number 21, the parameters of the 3D FFE, T2 FLAIR variable that was used to test, TR 8.1 ms, TE 3.7 ms, Slice number 240 I set to. The experiment was conducted by acquiring the FLAIR prior to contrast enhancement (heretofore referred to as Pre FLAIR), and acquiring the 3D FFE CE five minutes after the contrast enhancement, and recomposing the images in an axial plane of S/T 3mm, G 0mm (heretofore referred to as MPR TRA CE). Using the FLAIR 10 minutes after the contrast enhancement (heretofore referred to as Post FLAIR) and Pi-View, a retrospective study was conducted. Using MRIcro on the image of a patient confirmed for his diagnosis, the images before and after the contrast media, as well as the CNR and SNR of the MPR TRA CE images of the lesion and the site absent of lesion were compared and analyzed using a one-way analysis of variance. Results: CNR for Pre FLAIR and Post FLAIR were 34.35 and 60.13, respectively, with MPR TRA CE at 23.77 showing no significant difference (p<0.050). Post-experiment analysis shows a difference between Pre FLAIR and Post FLAIR in terms of CNR (p<0.050), but no difference in CNR between Post FLAIR and MPR TRA CE (p>0.050), indicating that the contrast media had an effect only on Pre FLAIR and Post FLAIR. The SNR for the normal site Pre FLAIR was 106.43, and for the lesion site 140.79. Post FLAIR for the normal site was 107.79, and for the lesion site 167.91. MPR TRA CE for the normal site was 140.23 and for the lesion site 183.19, showing significant difference (p<0.050), and post-experiment analysis shows that there was a difference in SNR only on the lesion sites for Pre FLAIR and Post FLAIR (p<0.050). There was no difference in SNR between the normal site and lesion site for Post FLAIR and MPR TRA CE, indicating no effect from the contrast media (p>0.050). Conclusions: This experiment shows that Post FLAIR has a higher contrast than Pre FLAIR, and a higher SNR for lesions, It was not not statistically significant and MPR TRA CE but CNR came out high. Inspection of post-contrast which is used in a high magnetic field is frequently used images of 3D T1 but, since the signal of the contrast medium and the blood flow is included, this method can be diagnostic accuracy is reduced, it is believed that when used in combination with Post FLAIR, and that can provide video information added to the diagnosis of brain metastases.

  • PDF

Cluster Analysis with Air Pollutants and Meteorological Factors in Seoul

  • Kim, Jae-Hee;Lim, Ji-Won
    • Journal of the Korean Data and Information Science Society
    • /
    • 제14권4호
    • /
    • pp.773-787
    • /
    • 2003
  • Principal component analysis, factor analysis and cluster analysis have been performed to analyze the relationship between air pollutants and meteorological variables measured in 1999 in Seoul. In principal analysis, the first principal has been shown the contrast effect between $O_3$ and the other pollutants, the second principal has been shown the contrast effect between CO, $SO_2$, $NO_2$ and $O_3$, PM10, TSP. In factor analysis, the first factor has been found as PM10, TSP, $NO_2$ concentrations which are related with suspended particulates. As a result of cluster analysis, three clusters respectively have represented different air pollution levels, seasonal characteristics of air pollutants and meteorological situations.

  • PDF

밝기, 명암도, 크기, 회전, 위치 변화에 강인한 얼굴 인식 (Face Recognition Robust to Brightness, Contrast, Scale, Rotation and Translation)

  • 이형지;정재호
    • 대한전자공학회논문지SP
    • /
    • 제40권6호
    • /
    • pp.149-156
    • /
    • 2003
  • 본 논문에서는 변형 Otsu 이진화 방법, Hu 모멘트 및 선형 판별 분석(linear discriminant analysis, LDA)를 기반으로 밝기, 명암도, 크기, 회전 위치 변화에 강인한 얼굴 인식 방법을 제안하고자 한다. 제안한 변형 Otsu 이진화를 사용하여 밝기 및 명암도에 불변한 이진 영상들을 만든다. 그런 후 생성된 얼굴 영상의 경계 영상 및 다단계 이진영상으로부터 총 17개의 Hu 모멘트를 계산한 다음 LDA 방법을 적용하여 최종 특징 벡터를 추출한다. 특히 제안하는 얼굴 인식 방법은 Hu 모멘트를 이용함으로써 크기, 회전 및 위치 변화에도 강인한 특성을 갖고 있다. Olivetti research laboratory (ORL) 데이터베이스와 AR 데이터베이스의 총 100명의 얼굴 영상에 대해 기존의 주요 성문 분석(Principal component analysis, PCA) 방법 및 PCA와 LDA를 결합한 얼굴 인식 방법과 비교 실험한 결과, 제안한 얼굴 인식 방법은 대체적으로 기존 방법보다 뛰어난 인식 성능을 보였다.

Prognostic Prediction Based on Dynamic Contrast-Enhanced MRI and Dynamic Susceptibility Contrast-Enhanced MRI Parameters from Non-Enhancing, T2-High-Signal-Intensity Lesions in Patients with Glioblastoma

  • Sang Won Jo;Seung Hong Choi;Eun Jung Lee;Roh-Eul Yoo;Koung Mi Kang;Tae Jin Yun;Ji-Hoon Kim;Chul-Ho Sohn
    • Korean Journal of Radiology
    • /
    • 제22권8호
    • /
    • pp.1369-1378
    • /
    • 2021
  • Objective: Few attempts have been made to investigate the prognostic value of dynamic contrast-enhanced (DCE) MRI or dynamic susceptibility contrast (DSC) MRI of non-enhancing, T2-high-signal-intensity (T2-HSI) lesions of glioblastoma multiforme (GBM) in newly diagnosed patients. This study aimed to investigate the prognostic values of DCE MRI and DSC MRI parameters from non-enhancing, T2-HSI lesions of GBM. Materials and Methods: A total of 76 patients with GBM who underwent preoperative DCE MRI and DSC MRI and standard treatment were retrospectively included. Six months after surgery, the patients were categorized into early progression (n = 15) and non-early progression (n = 61) groups. We extracted and analyzed the permeability and perfusion parameters of both modalities for the non-enhancing, T2-HSI lesions of the tumors. The optimal percentiles of the respective parameters obtained from cumulative histograms were determined using receiver operating characteristic (ROC) curve and univariable Cox regression analyses. The results were compared using multivariable Cox proportional hazards regression analysis of progression-free survival. Results: The 95th percentile value (PV) of Ktrans, mean Ktrans, and median Ve were significant predictors of early progression as identified by the ROC curve analysis (area under the ROC curve [AUC] = 0.704, p = 0.005; AUC = 0.684, p = 0.021; and AUC = 0.670, p = 0.0325, respectively). Univariable Cox regression analysis of the above three parametric values showed that the 95th PV of Ktrans and the mean Ktrans were significant predictors of early progression (hazard ratio [HR] = 1.06, p = 0.009; HR = 1.25, p = 0.017, respectively). Multivariable Cox regression analysis, which also incorporated clinical parameters, revealed that the 95th PV of Ktrans was the sole significant independent predictor of early progression (HR = 1.062, p < 0.009). Conclusion: The 95th PV of Ktrans from the non-enhancing, T2-HSI lesions of GBM is a potential prognostic marker for disease progression.

초음파 조영제의 합성 및 합성된 초음파 조영제의 특성 분석 (Synthesis of Ultrasound Contrast Agent: Characteristics and Size Distribution Analysis)

  • 이학종;윤태종;윤영일
    • Ultrasonography
    • /
    • 제32권1호
    • /
    • pp.59-65
    • /
    • 2013
  • 목적: 본 연구는 초음파 조영제를 직접 합성하고 그 크기 및 소멸 시간 등의 특성을 분석하며, 기존의 초음파 조영제와의 영상을 비교하여 앞으로 초음파 조영제를 매개로 한 영상 유도 하 약물 및 유전자 치료제의 전달 시스템 구축의 기본을 갖추고자 한다. 대상 및 방법: 초음파 조영제는 21마이크로 몰의 DPPC(1, 2-Dihexadecanoyl-sn-glycero-3-phosphocholine, $C_{40}H_{80}NO_8P$), 9 마이크로 몰의 콜레스테롤, 1.9 마이크로 몰의 DCP(Dihexadecylphosphate, $[CH_3(CH_2)_{15}O]_2P(O)OH$) 및 클로로포름 및 SF6 기체를 이용하여 합성하였다. 약 12-24시간의 동결건조 후에 초음파 조영제는 SF6 기체와 초음파 처리(sonication) 법을 이용하여 합성하였고 그 초음파 조영제의 크기는 압출기를 이용하여 일정한 크기로 조정하였다. 합성된 초음파 조영제는 동적 광산란 측정법(dynamic light scattering measurement)을 이용하여 그 크기를 분석하였다. 한편 합성한 초음파 조영제의 소멸 양상을 평가하기 위하여 광학 현미경을 이용하여 그 숫자를 합성 직후, 12시간, 24시간, 36시간, 48시간, 60시간, 72시간 및 84시간 후에 평가하였다. 초음파 조영제로서의 효과를 평가하기 위하여 모형을 만들어 현재 임상적으로 사용되고 있는 초음파 조영제와 그 에코를 비교 분석하였다. 결과: 초음파 조영제는 동결건조-초음파 처리 방법을 통하여 성공적으로 합성 할 수 있었다. 합성된 초음파 조영제는 154.2 nm의 정점 (peak)에서 가장 많이 분포하였으며 합성 후 24시간부터는 입자의 숫자들이 감소하는 양상을 보였다. 소노뷰와 합성된 초음파 조영제의 에코밝기는 유의한 차이를 보이지 않았으나 소노뷰와 생리식염수 및 합성된 초음파 조영제와 생리식염수의 에코 밝기는 통계적으로 유의한 차이를 보였다 (p < 0.01). 결론: 본 연구를 통하여 초음파 조영제를 직접 합성할 수 있는 방법을 습득할 수 있었고 그 크기 및 특성을 분석할 수 있었다.

Salient Object Detection Based on Regional Contrast and Relative Spatial Compactness

  • Xu, Dan;Tang, Zhenmin;Xu, Wei
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제7권11호
    • /
    • pp.2737-2753
    • /
    • 2013
  • In this study, we propose a novel salient object detection strategy based on regional contrast and relative spatial compactness. Our algorithm consists of four basic steps. First, we learn color names offline using the probabilistic latent semantic analysis (PLSA) model to find the mapping between basic color names and pixel values. The color names can be used for image segmentation and region description. Second, image pixels are assigned to special color names according to their values, forming different color clusters. The saliency measure for every cluster is evaluated by its spatial compactness relative to other clusters rather than by the intra variance of the cluster alone. Third, every cluster is divided into local regions that are described with color name descriptors. The regional contrast is evaluated by computing the color distance between different regions in the entire image. Last, the final saliency map is constructed by incorporating the color cluster's spatial compactness measure and the corresponding regional contrast. Experiments show that our algorithm outperforms several existing salient object detection methods with higher precision and better recall rates when evaluated using public datasets.

음소대조 검사방법을 이용한 마비말장애인의 말소리 명료도 특성 (The Speech Characteristics of Korean Dysarthria: An Experimental Study with the Use of a Phonetic Contrast Intelligibility Test)

  • Kim Soo Jin;Kim Young Tae;Kim Gi Na
    • The Journal of the Acoustical Society of Korea
    • /
    • 제24권1E호
    • /
    • pp.28-33
    • /
    • 2005
  • This study was designed to suggest an assessment tool for analyzing the characteristics of Korean phonetic contrast intelligibility among dysarthric individuals. The intelligibility deficit factors of phonetic contrast in Korean dysarthric patients were analyzed through stepwise regression analysis. The 19 acoustic-phonetic contrasts proposed by Kent et al. (1999) have been claimed to be useful for clinical assessment and research on dysarthria. However, the test cannot be directly applied to Korean patients due to linguistic differences between English and Korean. Thus, it is necessary to devise a Korean word intelligibility test that reflects the distinct characteristics of the Korean language. To identify the speech error characteristics of a Korean dysarthric group, a Korean word list was audio-recorded by 3 spastic, 4 flaccid, and 5 mixed type of dysarthric patients. The word list consisted of monosyllabic consonant-vowel-consonant (CVC) real word pairs. Stimulus words included 41 phonemic contrast pairs and six triplets. The results showed that the percentage of errors in final position contrast was higher than in any other position. Unlike the results of previous studies, the initial-position contrasts were crucial in predicting the overall intelligibility among Korean patients.