• Title/Summary/Keyword: Contralateral breast cancer

Search Result 45, Processing Time 0.035 seconds

Comparison of Virtual Wedge versus Physical Wedge Affecting on Dose Distribution of Treated Breast and Adjacent Normal Tissue for Tangential Breast Irradiation (유방암의 방사선치료에서 Virtual Wedge와 Physical Wedge사용에 따른 유방선량 및 주변조직선량의 차이)

  • Kim Yeon-Sil;Kim Sung-Whan;Yoon Sel-Chul;Lee Jung-Seok;Son Seok-Hyun;Choi Ihl-Bong
    • Radiation Oncology Journal
    • /
    • v.22 no.3
    • /
    • pp.225-233
    • /
    • 2004
  • Purpose: The Ideal breast irradiation method should provide an optimal dose distribution In the treated breast volume and a minimum scatter dose to the nearby normal tissue. Physical wedges have been used to Improve the dose distribution In the treated breast, but unfortunately Introduce an Increased scatter dose outside the treatment yield, pavllculariy to the contralateral breast. The typical physical wedge (FW) was compared with 4he virtual wedge (VW) to do)ermine the difference In the dose distribution affecting on the treated breast and the contralateral breast, lung, heart and surrounding perlpheral soft tissue. Methods and Materials: The data collected consisted of a measurement taken with solid water, a Humanoid Alderson Rando phantom and patients. The radiation doses at the ipsllateral breast and skin, contralateral breast and skin, surrounding peripheral soft tissue, and Ipsllateral lung and heart were compared using the physical wedge and virtual wedge and the radiation dose distribution and DVH of the treated breast were compared. The beam-on time of each treatment technique was also compared Furthermore, the doses at treated breast skin, contralateral breast skin and skin 1.5 cm away from 4he field margin were also measured using TLD in 7 patients of tangential breast Irradiation and compared the results with phantom measurements. Results: The virtual wedge showed a decreased peripheral dose than those of a typical physical wedge at 15$^{\circ}$, 30$^{\circ}$, 45$^{\circ}$, and 60$^{\circ}$. According to the TLD measurements with 15$^{\circ}$ and 30$^{\circ}$ virtual wedge, the Irradiation dose decreased by 1.35$\%$ and 2.55$\%$ In the contralateral breast and by 0.87$\%$ and 1.9$\%$ In the skin of the contralateral breast respectively. Furthermore, the Irradiation dose decreased by 2.7$\%$ and 6.0$\%$ in the Ipsllateral lung and by 0.96$\%$ and 2.5$\%$ in the heart. The VW fields had lower peripheral doses than those of the PW fields by 1.8$\%$ and 2.33$\%$. However the skin dose Increased by 2.4$\%$ and 4.58$\%$ In the Ipsliateral breast. VW fields, In general, use less monitor units than PW fields and shoriened beam-on time about half of PW. The DVH analysis showed that each delivery technique results In comparable dose distribution in treated breast. Conclusion: A modest dose reduction to the surrounding normal tissue and uniform target homogeneity were observed using the VW technique compare to the PW beam in tangential breast Irradiation The VW field is dosmetrically superlor to the PW beam and can be an efficient method for minimizing acute, late radiation morbidity and reduce 4he linear accelerator loading bV decreasing the radiation delivery time.

The Role Of Tumor Marker CA 15-3 in Detection of Breast Cancer Relapse After Curative Mastectomy (유방암 환자에서 근치적 유방 절제술 후 재발 발견에 대한 CA 15-3의 역할)

  • Hyun, In-Young;Kim, In-Ho;Lee, Moon-Hee;Kim, Chul-Soo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.4
    • /
    • pp.311-317
    • /
    • 2004
  • Purpose: The purpose of this study was to determine the utility of tumor marker CA 15-3 in the following: the diagnosis of breast cancer relapse after curative mastectomy, and the differentiation or the value of tumor marker by site of metastases. Materials and Methods: Two hundred two patients (median age 48 years) with breast cancer included in the follow-up after curative mastectomy. The tumor marker CA 15-3 was determined by IRMA (CIS BIO INTERNATIONAL, France). Test values > 30 U/ml were considered elevated (positive). Results: Among 202 patients, recurrent diseases were found in 16 patients. CA 15-3 was elevated in 5 of 16 patients with recurrences. There was no false-positive patient who had elevated CA 15-3. Sensitivity and specificity of CA 15-3 for detection of breast cancer recurrence were 31%, and 100%. CA 15-3 was elevated in all of the 4 patients with liver metastases. CA 15-3 was elevated in none of the patients who relapsed with metastasis to bone-only or contralateral breast-only. Conclusion: The tumor marker CA 15-3 in the detection of breast cancer relapse after curative mastectomy is specific, but not sensitive. However, it is useful to rule out liver metastases of breast cancer, which indicates bad prognosis.

Immediate Nipple Reconstruction in Breast Reconstruction with TRAM Free Flap (횡복직근 유리피판을 이용한 유방재건술에서의 즉시 유두재건)

  • Kim, Jeong Tae;Kim, Chang Yeon;Cha, Ji Hun;Hwang, Weon Jung
    • Archives of Plastic Surgery
    • /
    • v.32 no.1
    • /
    • pp.76-84
    • /
    • 2005
  • Immediate breast reconstruction in breast cancer patients is universalized and now with a wide variety of methods to choose from, we can select a breast reconstruction method according to the patient's condition. Among these methods, immediate breast reconstruction with TRAM free flap is the most commonly used. Nipple reconstruction is usually performed as a secondary procedure, reconstructed. Nipple is reconstructed with contralateral nipple composite graft or with local flap. Areola is reconstructed with skin graft and tattooing. Therefore, to reconstruct complete breast, two or more staged operations are needed and are troublesome to both the surgeon and the patient. If we could reconstruct breast mound and nipple at same time, we would reduce the operative stages and heighten the patient's satisfaction. The author performed delayed or immediate breast reconstruction with TRAM free flap and nipple reconstruction at the same time. If the TRAM flap was to situate in the whole of the breast or at the center of the breast mound, nipple was reconstructed with a local flap from the TRAM flap. If the TRAM flap was not situated in center of breast mound, nipple was reconstructed with a local flap from remnant breast skin. Immediate nipple reconstructions in breast reconstruction consisted total of 22 cases. Among these, delayed breast reconstruction were 5 cases and immediate breast reconstruction were 17 cases. According to patient's condition and mastectomy method, nipple reconstruction method was selected; nipple reconstruction with contralateral nipple composite graft(3 cases); nipple reconstruction with remnant breast skin(6 cases); nipple reconstruction from flap margin(10 cases); nipple reconstruction with prefabricated nipple on flap(3 cases). Malposition of the reconstructed nipple was the most common and serious complication(6 cases). The other complications were atrophy of the nipple(1 case), and necrosis(1 case). Reconstruction of the breast and nipple at the same time can reduce the need of a secondary operation and use remnant skin or redundant flap tissue maximally. On the other hand, it must be considered that position and shape of nipple could be deformed, because the nipple reconstruction is performed before the shape of reconstructed breast settles completely. Prudent attention is needed, because the danger of complication is higher than delayed nipple reconstruction.

Planning Aspects of Volumetric Modulated Arc Therapy and Intensity Modulated Radio therapy in Carcinoma Left Breast - A Comparative Study

  • Ekambaram, Varadharajan;Velayudham, Ramasubramanian;Swaminathan, Shiyama;Loganathan, Padmanabhan;Swaminathan, Vijaya
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.4
    • /
    • pp.1633-1636
    • /
    • 2015
  • Background: The advantages of Rapid Arc plans versus Intensity modulated radiotherapy plans for Carcinoma left breast were analyzed. Materials and Methods: In this study 20 Post mastectomy carcinoma left breast patients were analyzed. Both Intensity modulated Radiotherapy and Rapid Arc plans were generated for these patients. IMRT plans with 7 beams in an arc fashion and VMAT plans with two semi arcs were made to achieve 95% dose coverage to 100% volume. The plans were evaluated using Dose volume Histograms. Results: The mean Conformity and Homogeneity index in VMAT is found to be 1.05 and 0.065 respectively whereas in IMRT it was 1.07 and 0.069. The 20% volume of Heart received a mean dose of 960cGy in VMAT and 1300cGy in IMRT. The mean dose was 1236cGy in VMAT and 1870cGy in IMRT. The ipsilateral Lung received 3395cGy to 5% volume and 1840cGy to 20% volume on an average and the mean dose was 1205cGy in VMAT, while the same were found to be 3525cGy, 2012cGy and 1435cGy respectively in IMRT. The Contralateral Lung received a mean dose of 505cGy in VMAT and 553cGy in IMRT. The mean Monitor units in VMAT were 512MU and 1170MU in IMRT. The NTID in VMAT is $108.8{\times}10^5Gycm^3$ and $110.1{\times}10^5Gycm^3$ in IMRT. Conclusions: The target coverage, homogeneity and Conformity index were better in VMAT plans. The Ipsilateral Lung and heart dose were very less in VMAT plans. The Contralateral Lung dose and the Normal Tissue Integral Dose were also lesser in VMAT plans however the difference is not very appreciable. The MU in VMAT plans is almost 50% that of the IMRT plans which results in the reduction of treatment time. On the whole VMAT proves to be a better modality for treating Ca. Left Breast Patients.

Risk Reducing Surgery in Carriers with Double Heterozygosity for BRCA1 and BRCA2 Mutations

  • Hong, Woo-Sung;Kim, Ku-Sang;Jung, Yong-Sik;Kang, Seok-Yun;Kang, Doo-Kyoung;Kim, Tae-Hee;Yim, Hyunee;Chun, Mi-Son;Park, Myong-Chul;Chang, Suk-Joon
    • Journal of Genetic Medicine
    • /
    • v.9 no.1
    • /
    • pp.25-30
    • /
    • 2012
  • Among the treatment options for BRCA mutation carriers, risk reducing surgery is the most effective. However, this procedure has been rarely performed in Korea. Interestingly, our case showed double heterozygosity for BRCA1 and BRCA2 mutations. The patient was diagnosed with left renal cancer and left breast cancer at 45-years-of-age, 4 years before risk reducing surgery. The patient received left radical nephrectomy and left partial mastectomy with axillary lymph node dissection. After pretest counseling, the patient underwent genetic testing that identified BRCA1 and BRCA2 mutations. After post-test counseling, the patient decided on intensive surveillance. At 49-years-of-age, the patient was newly diagnosed with contralateral breast cancer. Treatment options were discussed once again. We performed bilateral total mastectomy with immediate reconstruction and prophylactic bilateral salpingo-oophorectomy after multidisciplinary discussion. The patient has been satisfied with the results of surgery. We think this procedure is a recommendable treatment option for BRCA mutation carriers.

Comparison of Dosimetrical and Radiobiological Parameters on Three VMAT Techniques for Left-Sided Breast Cancer

  • Kang, Seong-Hee;Chung, Jin-Beom;Kim, Kyung-Hyeon;Kang, Sang-Won;Eom, Keun-Yong;Song, Changhoon;Kim, In-Ah;Kim, Jae-Sung
    • Progress in Medical Physics
    • /
    • v.30 no.1
    • /
    • pp.7-13
    • /
    • 2019
  • Purpose: To compare the dosimetrical and radiobiological parameters among various volumetric modulated arc therapy (VMAT) techniques using restricted and continuous arc beams for left-sided breast cancer. Materials and Methods: Ten patients with left-sided breast cancer without regional nodes were retrospectively selected and prescribed the dose of 42.6 Gy in 16 fractions on the planning target volume (PTV). For each patient, three plans were generated using the $Eclipse^{TM}$ system (Varian Medical System, Palo Alto, CA) with one partial arc 1pVMAT, two partial arcs 2pVMAT, and two tangential arcs 2tVMAT. All plans were calculated through anisotropic analytic algorithm and photon optimizer with 6 MV photon beam of $VitalBEAM^{TM}$. The same dose objectives for each plan were used to achieve a fair comparison during optimization. Results: For PTV, dosimetrical parameters such as Homogeneity index, conformity index, and conformal number were superior in 2pVMAT than those in both techniques. $V_{95%}$, which indicates PTV coverage, was 91.86%, 96.60%, and 96.65% for 1pVMAT, 2pVMAT, and 2tVMAT, respectively. In most organs at risk (OARs), 2pVMAT significantly reduced the delivered doses compared with the other techniques, excluding the doses to contralateral lung. For the analysis of radiobiological parameters, a significant difference in normal tissue complication probability was observed in ipsilateral lung while no difference was observed in the other OARs. Conclusions: Our study showed that 2pVMAT had better plan quality and normal tissue sparing than 1pVMAT and 2tVMAT but not for all parameters. Therefore, 2pVMAT could be considered the priority choice for the treatment planning for left breast cancer.

Risk Factors for Recurrence after Conservative Treatment in Early Breast Cancer: Preliminary Report (조기유방암에서 유방보존술 후 재발에 영향을 주는 인자)

  • Suh Chang Ok;Chung Eun Ji;Lee Hy De;Lee Kyong Sik;Oh Ki Keun;Kim Gwi Eon
    • Radiation Oncology Journal
    • /
    • v.15 no.4
    • /
    • pp.331-337
    • /
    • 1997
  • Purpose : To evaluate our experience in the breast-conserving treatment for early breast cancer with special regard to recurrence Pattern and related risk factors. Materials and Method :Two hundred and sixteen patients with AJC stage 1and 11 breast cancer who received breast conserving treatment between January 1991 and December 1994 were evaluated A9e distribution ranged from 23-80 year old with a median a9e of 44. One hundred and seventeen Patients had 71 lesions and 99 Patients had 72 lesions. Axillary lymph nodes were involved in 73 patients. All patients received a breast conserving surgery (wide excision to quadrantectomy) and axillary node dissection followed by radiotherapy. Ninety six patients received chemotherapy before or after radiotherapy. Results : During the follow-up period (3-60 months, median 30 months), local recurrences were noted in six Patients (true: 3, elsewhere; 1, skin: 2). Sixteen patients developed distant metastases as the first sign of recurrence at 8-38 months (median 20 months) after surgery. Among them, three patients simultaneously developed local recurrence with distant metastases. Contralateral breast cancer developed in one Patient and non-mammary cancers developed in three patients. The actuarial 5 year survival rate was $88.4\%\;(stage\;I\;96.7\%,\;stage\;IIa\;95.2\%,\;stage\;IIb\;69.9\%)$. Age, I stage, number of involved axillary lymph nodes. and AJC stage were risk factors for distant metastases in univariate analysis. In the multivariate analysis, the number of involved axillary lymph nodes was the most significant risk factor for metastases. Conclusion : Local recurrence was not common in the early years after radiotherapy. Distant metastases occurred at a steady rate during the first three years and was more common in the Patients with larger tumors, higher number of involved axillary nodes, and younger age.

  • PDF

Breast Conservation Therapy Versus Mastectomy - Preliminary Results of Pattern of Failure and Survival Rate in Early Breast Cancer (조기유방암에서 유방보존치료와 유방전절제술의 치료결과 및 실패양상 비교)

  • Kim Yeon-Sil;Yoon Sei-Chul;Chung Su-Mi;Ryu Mi-Ryeong;Jung Sang-Sul;Choi Ihl-Bohng
    • Radiation Oncology Journal
    • /
    • v.22 no.2
    • /
    • pp.115-123
    • /
    • 2004
  • Purpose : This retrospective study was conducted to compare early preliminary results of breast conservation therapy (BCT) with mastectomy In early breast cancer. Materials and Methods : We evaluated 171 women with AJCC stage I and II breast cancer who had been treated at Kangnam St. Mary's Hospital from March 1989 to August 1996. Eighty-eight patients underwent mastectomy and 85 patients did conservative surgery with breast irradiation. in the BCT group, all patients received whole breast irradiation to a total dose of 45$\~$50 Gy/5$\~$6 wks, followed by a boost to the original tumor site at least 60 Gy. Chemotherapy was administered to 29 (34.1$\%$) patients in BCT and 40 (45.5$\%$) in mastectomy, with various sequencing of surgery and/or radiation. We compared survival rate, patterns of failure in each treatment group and the prognostic factors that had a significant effect on treatment failure. The median follow-up time was 63 months (19$\~$111 months). Log rank test was used to estimate the prognostic factors for treatment failure. Results : Overall survival, disease free survival, locoregional recurrence and distant metastasis rates were not significantly different between the two treatment groups. During the follow-up period, 11 patients (12.5$\%$)in the mastectomy group and 10 patients (11.8%$\%$ in the BCT group were failed. Six local recurrences occurred after mastectomy and 5 after BCT Five patients fatted at distant site in mastectomy and 4 in BCT. Of the local recurrence cases, five of 6 mastectomy patients and 3 of S BCT patients were alive with no evidence of disease after salvage surgery and/or chemoirradiation. Our results indicated that the major influence on survival was distant metastasis. Unfortunately, control of distant metastasisis was not frequently achieved. Even with salvage systemic therapy or radiotherapy, most of distant metastasis patients died or had uncontrolled disease in both treatment groups: only one of 4 BCT patients and none of mastectomy patients were alive without disease. There was no apparent difference in the incidence rate of contralateral breast cancer and non-breast 2$^{nd}$ primary tumor between the two treatment groups. Univariate Log-rank test identified the N stage and the involved axillary LN number as distinct prognostic factors that were highly predictive of treatment failure in both treatment groups. Additionally, marginal status in BCT and histologic nuclear grade In the mastectomy group were risk factors for treatment fallure (p < 0.05). Concousion : Although further careful follow-up is necessary to confirm the trends evident In this serles, it would appear that patterns of failure and survival rate following conservative surgery and radiotherapy in early breast cancer are similar to those following mastectomy. The great majority of patients with local recurrence had an exellent salvage rate in both treatment groups. Therefore, these preliminary short term results support BCT as an equally effective management for early breast cancer as an alternative to mastectomy.

Feasibility Study of Deep Inspiration Breath-Hold Based Volumetric Modulated Arc Therapy for Locally Advanced Left Sided Breast Cancer Patients

  • Swamy, Shanmugam Thirumalai;Radha, Chandrasekaran Anu;Kathirvel, Murugesan;Arun, Gandhi;Subramanian, Shanmuga
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.20
    • /
    • pp.9033-9038
    • /
    • 2014
  • Background: The purpose of this study was to assess the feasibility of deep inspiration breath-hold (DIBH) based volumetric modulated arc therapy (VMAT) for locally advanced left sided breast cancer patients undergoing radical mastectomy. DIBH immobilizes the tumor bed providing dosimetric benefits over free breathing (FB). Materials and Methods: Ten left sided post mastectomy patients were immobilized in a supine position with both the arms lifted above the head on a hemi-body vaclock. Two thermoplastic masks were prepared for each patient, one for normal free breathing and a second made with breath-hold to maintain reproducibility. DIBH CT scans were performed in the prospective mode of the Varian real time position management (RPM) system. The planning target volume (PTV) included the left chest wall and supraclavicular nodes and PTV prescription dose was 5000cGy in 25 fractions. DIBH-3DCRT planning was performed with the single iso-centre technique using a 6MV photon beam and the field-in-field technique. VMAT plans for FB and DIBH contained two partial arcs ($179^{\circ}-300^{\circ}CCW/CW$). Dose volume histograms of PTV and OAR's were analyzed for DIBH-VMAT, FB-VMAT and DIBH-3DCRT. In DIBH mode daily orthogonal ($0^{\circ}$ and $90^{\circ}$) KV images were taken to determine the setup variability and weekly twice CBCT to verify gating threshold level reproducibility. Results: DIBH-VMAT reduced the lung and heart dose compared to FB-VMAT, while maintaining similar PTV coverage. The mean heart $V_{30Gy}$ was $2.3%{\pm}2.7$, $5.1%{\pm}3.2$ and $3.3%{\pm}7.2$ and for left lung $V_{20Gy}$ was $18.57%{\pm}2.9$, $21.7%{\pm}3.9$ and $23.5%{\pm}5.1$ for DIBH-VMAT, FB-VMAT and DIBH-3DCRT respectively. Conclusions: DIBH-VMAT significantly reduced the heart and lung dose for left side chest wall patients compared to FB-VMAT. PTV conformity index, homogeneity index, ipsilateral lung dose and heart dose were better for DIBH-VMAT compared to DIBH-3DCRT. However, contralateral lung and breast volumes exposed to low doses were increased with DIBH-VMAT.

Diagnostic Performance of Combined Single Photon Emission Computed Tomographic Scintimammography and Ultrasonography Based on Computer-Aided Diagnosis for Breast Cancer (유방 SPECT 및 초음파 컴퓨터진단시스템 결합의 유방암 진단성능)

  • Hwang, Kyung-Hoon;Lee, Jun-Gu;Kim, Jong-Hyo;Lee, Hyung-Ji;Om, Kyong-Sik;Lee, Byeong-Il;Choi, Duck-Joo;Choe, Won-Sick
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.3
    • /
    • pp.201-208
    • /
    • 2007
  • Purpose: We investigated whether the diagnostic performance of SPECT scintimammography (SMM) can be improved by adding computer-aided diagnosis (CAD) of ultrasonography (US). Materials and methods: We reviewed breast SPECT SMM images and corresponding US images from 40 patients with breast masses (21 malignant and 19 benign tumors). The quantitative data of SPECT SMM were obtained as the uptake ratio of lesion to contralateral normal breast. The morphologic features of the breast lesions on US were extracted and quantitated using the automated CAD software program. The diagnostic performance of SPECT SMM and CAD of US alone was determined using receiver operating characteristic (ROC) curve analysis. The best discriminating parameter (D-value) combining SPECT SMM and the CAD of US was created. The sensitivity, specificity and accuracy of combined two diagnostic modalities were compared to those of a single one. Results: Both SPECT SMM and CAD of US showed a relatively good diagnostic performance (area under curve = 0.846 and 0.831, respectively). Combining the results of SPECT SMM and CAD of US resulted in improved diagnostic performance (area under curve =0.860), but there was no statistical differerence in sensitivity, specificity and accuracy between the combined method and a single modality. Conclusion: It seems that combining the results of SPECT SMM and CAD of breast US do not significantly improve the diagnostic performance for diagnosis of breast cancer, compared with that of SPECT SMM alone. However, SPECT SMM and CAD of US may complement each other in differential diagnosis of breast cancer.