• 제목/요약/키워드: Contraction Angle

검색결과 168건 처리시간 0.028초

운동 전 적용된 지속초음파와 맥동초음파가 운동 유발성 근육 손상의 최대등척성근력과 관절가동범위에 미치는 효과 (The effects of pulsed ultrasound and continued ultrasound intervention before an exercise on maximal voluntary isometric contraction and range of motion of exercise-induced muscle damage)

  • 김하늘;전재근;신성필
    • 대한물리치료과학회지
    • /
    • 제28권2호
    • /
    • pp.19-29
    • /
    • 2021
  • Background: The purpose of this study was to investigate the effects of pulsed-ultrasound intervention and continued-ultrasound on the MVIC (maximal voluntary isometric contraction) and active ROM (range of motion) recovery of before EIMD (exercise-induced muscle damage). Design: Randomized controlled trial. Methods: Thirty subjects who are student in their 20s at a university participated in this study, these subjects were assigned into three groups, a control group (n=10), experiment group I (n=10) and experiment group II (n=10). The subjects in experimental group were intervened by pulsed-ultrasound and continued-ultrasound, while ones on control group weren't by any intervention after induced EIMD. Results: First, In comparison of the MVIC, in the among group comparison, the MVIC of continued-ultrasound group was significantly larger than those of other groups (p<.005). Second, In the among group comparison, the active extension angle of continued-ultrasound group was significantly smaller than those of other groups (p<.005). Third, In the among group comparison, the active flexion angle of continued-ultrasound group was significantly lager than those of other groups (p<.05). Conclusion: The above results revealed that the continued-ultrasound intervention before an exercise had a significantly improve of muscle function after EIMD. Therefore we can consider the continued ultrasound as a considerable intervention method to prevent or reduce an exercise injury.

Effect of 4 Weeks of Pilates Exercise in Women using Light LED EMG Feedback System on Posture and Balance; Randomized Controlled Trial

  • Jeong Eun Youn;Dae-Sung Park
    • Physical Therapy Rehabilitation Science
    • /
    • 제12권3호
    • /
    • pp.214-221
    • /
    • 2023
  • Objective: This study aimed to assess the impact of using the LED light electromyographyfeedback system (EMG-light) during Pilates exercises in women to maintain consistent muscle contraction in the abdominal external oblique muscles and reduce muscle contraction in the upper trapezius muscles. This study compared Pilates training using the EMG-light with Pilates training only in healthy women for 4 weeks. Design: This study was conducted as a cross-sectional study. Methods: A total of 17 healthy women were divided into an experimental group (n=9) and a control group (n=8). Both groups performed Pilates exercises as assigned, twice per week for four weeks, with each session lasting fifty minutes. The experimental group were used the EMG-light feedback system during pilates exercise while the control group did not use EMG-light. We used cervical vertebral angle (CVA), shoulder tilt angle to evaluate neck posture and standing balance with closed eye for 30s before and after exercise. Results: The control group exhibited a significant change in CVA (p<0.05). Both groups showed significant changes in shoulder tilt, center of pressure (COP) path-length, and COP velocity during eyes-closed conditions (p<0.05). However, there were significant differences between the experimental and control groups in terms of CVA, shoulder tilt, COP path-length, and COP velocity. Conclusions: This study demonstrated that Pilates exercises had positive effects on shoulder posture and balance. The use of EMG-light provided real-time visual feedback on muscle contraction during Pilates exercise. However, the experimental group did not show significant improvements compared to the control group, which performed Pilates exercises without feedback.

근 길이에 따른 근 섬유 동원률의 차이 (The Effect of the Muscle Firing Rate on Muscle Length)

  • 송영희;정이정;조상현
    • 한국전문물리치료학회지
    • /
    • 제11권3호
    • /
    • pp.85-90
    • /
    • 2004
  • The purpose of this study was to find the difference in muscle firing rate between each muscle according to the knee angle with the quadriceps femoris which is a representative action muscle of the lower extremity. Seven normal healthy subjects were recruited. The median frequency (MDF) of muscle contraction was recorded from vastus lateralis, vastus medialis, and rectus femoris muscles using the surface EMG, in 5 seconds, during maximal isometric knee extension. The data were analyzed by the two-way repeated ANOVA. The results of the study were as follows: 1) median frequency of muscle contraction was significantly higher at the vastus lateralis, vastus medialis, and rectus femoris in descending order. 2) median frequency of muscle contraction was significantly higher at the $30^{\circ}$, $60^{\circ}$, and $90^{\circ}$ in descending order. Consequently, muscle recruitment at the knee decreases the EMG activity of the lengthened muscle. This study suggests that the change in EMG activity at different muscle lengths resulted in affecting the muscle firing rate during the knee extension.

  • PDF

Movement and evolution of macromolecules in a grooved micro-channel

  • Zhou, L.W.;Liu, M.B.;Chang, J.Z.
    • Interaction and multiscale mechanics
    • /
    • 제6권2호
    • /
    • pp.157-172
    • /
    • 2013
  • This paper presented an investigation of macromolecular suspension in a grooved channel by using the dissipative particle dynamics (DPD) with finitely extensible non-linear elastic (FENE) bead spring chains model. Before studying the movement and evolution of macromolecules, the DPD method was first validated by modeling the simple fluid flow in the grooved channel. For both simple fluid flow and macromolecular suspension, the flow fields were analyzed in detail. It is found that the structure of the grooved channel with sudden contraction and expansion strongly affects the velocity distribution. As the width of the channel reduces, the horizontal velocity increases simultaneously. Vortices can also be found at the top and bottom corners behind the contraction section. For macromolecular suspension, the macromolecular chains influence velocity and density distribution rather than the temperature and pressure. Macromolecules tend to drag simple fluid particles, reducing the velocity with density and velocity fluctuations. Particle trajectories and evolution of macromolecular conformation were investigated. The structure of the grooved channel with sudden contraction and expansion significantly influence the evolution of macromolecular conformation, while macromolecules display adaptivity to adjust their own conformation and angle to suit the structure so as to pass the channel smoothly.

Effect of Fascial Distortion Model on the Cobb's Angle in Adolescents with Idiopathic Scoliosis

  • Lee, Woo-Jin
    • The Journal of Korean Physical Therapy
    • /
    • 제31권1호
    • /
    • pp.31-34
    • /
    • 2019
  • Purpose: This study examined the effects of the fascial distortion model (FDM) method on Cobb's angle. Methods: Fourteen subjects participated in this study. The idiopathic scoliosis group performed FDM treatments eight times in four weeks. A Shapiro-Wilks test was used to verify the normality of a group of idiopathic scoliosis patients. A paired t-test was performed to determine the satisfaction with the normality. Results: The difference in Cobb's angle was reduced significantly (p<0.05) by an average of $5.72^{\circ}{\pm}2.24$ from $15.51^{\circ}{\pm}1.81$ before the experiment. Conclusion: This study found that the use of the FDM method was effective in improving the Cobb's angle. The application of a FDM treatment appears to stabilize the fascia with decreased ability to adapt physiologically. The application of the CD and TB method of FDM treatment improved the asymmetry spine by dispersing moisture in fascia and improving the contraction and relaxation ability. The results suggest that the Cobb's angle is reduced when FDM is applied, thereby preventing the progression of curvature and avoiding psychological and physical problems that can arise from improving patients with scoliosis.

충돌형 노즐의 분무특성에 관한 실험적 연구 (An Experimental Study on the Spray Characteristics of Deflector Nozzle)

  • 김경훈;최영하;윤석주
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.291-294
    • /
    • 2002
  • This study describes the external spray characteristics of deflector nozzle such as the breakup procedures of liquid sheet, spray angle, discharge coefficient and bubble behaviors of spray and SMD at deflector nozzle. In order to visualize the spray behaviors shadow graphy technique were used. According to the increase of injection pressure, development of the spray passes through the dribbling, distoted jet, closed bubble due to the contraction by surface tension forces, the bubble opens into hollow tulip shape, and the curved surface straightened to form a conical sheet like as the simplex swirl atomizer. Spray cone angle was nearly 90 deg. Variations of SMD were examined in order to describe the dependency of SMD on the injection pressure and orifice diameter. The shape of deflector and oriffice diameter had an effect on the discharge coefficient.

  • PDF

충돌형 노즐의 분무형상 연구 (External Spray Characteristics of Deflector Nozzle)

  • 김경훈;최영하;윤석주
    • 한국분무공학회지
    • /
    • 제7권1호
    • /
    • pp.29-35
    • /
    • 2002
  • This study describes the external spray characteristics of deflector nozzle such as the breakup procedures of liquid sheet, spray angle, breakup length and bubble behaviors of spray at deflector nozzle. In order to visualize the spray behaviors shadow graphy technique were used. According to the increase injection pressure, deveopment of the spray passes through the dribbling, distoted jet, closed bubble due to the contraction by form a conical sheet like as the simplex swirl atomizer. As trying the analysis of the ratio of bubble length and width it was found that the ratios is comparable. Spray cone angle was nearly $90^{\circ}$.

  • PDF

Numerical Analysis on the Discharge Characteristics of a Liquid Rocket Engine Injector Orifice

  • Cho, Won-Kook;Kim, Young-Mog
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제3권1호
    • /
    • pp.1-8
    • /
    • 2002
  • A numerical analysis was performed on the fluid flow in injector orifice of a liquid rocket engine. The present computational code was verified against the published data for turbulent flow in a pipe with a sudden expansion-contraction. Considered were the parameters for the flow analysis in an injector orifice: Reynolds number, ratio of mass flow rate of the injector orifice and inlet flow rate, and slant angle of the injector orifice. The discharge coefficient increased slightly as the Reynolds number increased. The slant angle of the injector changed critically the discharge coefficient. The discharge coefficient increased by 7% when the slant angle changed from $-30^{\circ}$ to $30^{\circ}$ The ratio of mass flow rate had relatively little impact on the discharge coefficient.

Fluidic Muscle 실린더의 특성 해석 및 실험 (An Experiments and Characteristics Analysis of the Fluidic Muscle Cylinder)

  • 허신;김동수;김완두;배상규
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.974-979
    • /
    • 2004
  • The fluidic muscle cylinder consist of an air bellows tube, flanges and lock nuts. It's features are softness of material and motion, simplicity of structure, low production cost and high power efficiency. In this study, we carried out the finite element modelling and analysis about the main design variables such as contraction ration and force, diameter increment of fluidic muscle cylinder. On the basis of finite element analysis, the prototype of fluidic muscle cylinder was manufactured and tested. Finally, we compared the results between the test and the finite element analysis.

  • PDF

경량 의수용 SMA 구동식 생체모방 손가락 모듈 (SMA-driven Biomimetic Finger Module for Lightweight Hand Prosthesis)

  • 정성윤;문인혁
    • 제어로봇시스템학회논문지
    • /
    • 제18권2호
    • /
    • pp.69-75
    • /
    • 2012
  • This paper proposes a biomimetic finger module to be used in a lightweight hand prosthesis. The finger module consists of finger skeleton and an actuator module driven by SMA (Shape Memory Alloy). The prototype finger module can perform flexion and extension motions; finger flexion is driven by a contraction force of SMA, but it is extended by an elastic force of an extension spring inserted into the finger skeleton. The finger motions are controlled by feedback of electric resistance of SMA because the finger module has no sensors to measure length and angle. Total weight of a prototype finger module is 30g. In experiments the finger motions and finger grip force are tested and compared with simulation results when a constant contraction force of SMA is given. The experimental results show that the proposed SMA-driven finger module is feasible to the lightweight hand prosthesis.